Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Nitrogen diffusion in silicate minerals, with implications for nitrogen transport and cycling in the lithosphere

Diffusion laws for nitrogen in orthoclase, quartz, olivine and clinopyroxene were determined using a combination of experimental strategies that included: in-diffusion from C-H-O-N vapor; in-diffusion from molten NH 4 Cl; and ion implantation followed by heating to mobilize N. Most experiments were conducted at pressures near 1 bar, but seven experiments were also run in a piston-cylinder device at P total = 1 GPa. The C-H-O-N-source experiments were “wet” (H 2 O present); those on ion-implanted samples were dry. All N sources were highly enriched in 15 N to avoid spurious 14 N signals resulting from surface contamination. Use of 15 N also enabled depth profiling by nuclear reaction analysis (NRA) using the 15 N(p,αγ) 12 C reaction, which has a detection limit of ~10 ppm. Nitrogen profiles in three samples were characterized by both NRA and SIMS, with similar results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting displacement damage for ion irradiation: Origin of the overestimation of vacancy production in SRIM full-cascade calculations

Ion irradiation and implantation have wide applications that demand accurate determination of displacement damage profile and distribution of implanted ion concentration. The prediction of vacancies is especially important to determine displacements per atom (dpa), the standard parameter of primary radiation damage in materials. However, significant discrepancies exist in estimations of vacancies between full-cascade (F-C) and quick calculation (Q-C) options in the popular computer code SRIM. This study inspected the SRIM code and a relatively new code called Iradina, which uses a similar methodology, to develop an understanding of the origin of vacancy overestimation in the F-C options for SRIM and Iradina. Here, we found that the default values of thresholds (namely final energy in SRIM and replacement energy in Iradina) in displacement production calculations results in excessively large number of calculated vacancies and very few replacements. After conducting multiple calculations using SRIM, Iradina, and MARLOWE (all based on the binary collision approximation), a comparison of the results indicates that there is a shortcoming in the SRIM and Iradina F-C methodology for treating near-threshold collisions. This issue is responsible for the deficiency of replacements and excess of calculated vacancies in the SRIM and Iradina F-C results. Drawing on the principles of collision physics, we propose recommendations for modifying the source codes to address these issues.

36 MATERIALS SCIENCE↗

Multicenter Evaluation of Biochemical Relapse–Free Survival Outcomes for Intraoperatively Planned Prostate Brachytherapy Using an Automated Delivery System

Purpose: To report biochemical recurrence in prostate cancer treated with intraoperatively planned low-dose-rate prostate brachytherapy using an automated delivery system (IO-LDRB). Methods and Materials: Between 2003 and 2013, 2608 patients from 3 centers were treated with IO-LDRB as single-modality treatment for low or low-tier intermediate-risk prostate cancer. Databases from the 3 centers have been analyzed. These independent databases were collected prospectively. Patient, tumor, and treatment characteristics were then compared, Kaplan-Meier survival estimates of biochemical relapse–free survival (bRFS) were generated, and the Cox proportional hazards model was used to determine factors predicting for relapse. Results: A total of 2608 patients with a median follow-up of 4.7 (interquartile range, 3.1-6.9) years were analyzed. Median age was 64 (range, 42-84) years. In these patients, median initial prostate-specific antigen was 5.5 ng/mL, 74% were T1, and 26% were T2; 73% were Gleason 6, and 25% Gleason 7. Median percentage of biopsy cores positive was 33%, and median gland volume was 34.2 cm{sup 3}. Eleven percent of patients received hormones for a median of 3.0 months before implantation. Median seed activity was 0.437 mCi, D90 (dose covering 90% of the prostate volume) was 186.7 Gy, and V100 was 99.37%. Biochemical relapse was observed in 124 patients (4.8%), and median time to failure was 4.0 years. Predicted bRFS was 93% at 7 years. On Cox regression bRFS was dependent only on D90 at the time of implantation and prostate-specific antigen density. Conclusions: This study demonstrates that IO-LDRB is an effective treatment option for patients with low and low-tier intermediate-risk prostate cancer. Rates of biochemical relapse remain low several years after treatment. These results compared favorably to published manual preplan technique results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced biomechanical performance of additively manufactured Ti-6Al-4V bone plates

As the global trauma fixation devices market expands rapidly, it is imperative to improve the production of fixation devices through enhanced design accuracy and fit for best performance and maximum patient comfort. Selective laser melting (SLM) is one of the mature additive manufacturing methods, which provides a viable route for the rapid production of such devices. In this work, the ability of SLM to produce near-net-shape parts, as desired for medical implants, was utilized for the fabrication of bone plates from Ti-6Al-4V alloy powder. Martensitic microstructure obtained after the printing of alloy resulted in poor ductility, limiting its application in the field of orthopedics. A specially designed repeated cyclic heating and cooling close to but below the β-transus was used to transform from acicular to a bimodal microstructure without the need for plastic deformation prior to heat treatment for improving the ductility. Bone plates subjected to this heat treatment were mechanically tested by means of tensile and 3-point bend tests and demonstrated large improvement in ductility, and the values were comparable to those similar plates prepared from wrought alloy. Other important properties required for implants were assessed, such as corrosion resistance in simulated body fluid and cytocompatibility in vitro using MC3T3-E1 cells. These results for the bone plate after heat treatment were excellent and similar to those of the additively manufactured and wrought plates. Taken together, the performance of the additively manufactured bone plates after subjecting to heat treatment was similar to those of bone plate manufactured using wrought alloy. These results have important implications for the fabrication of patient-specific metallic orthopedic devices using SLM without compromising their biomechanical performance by subjecting them to a tailored heat treatment.

36 MATERIALS SCIENCE↗

Expanding the capability of reaction-diffusion codes using pseudo traps and temperature partitioning: Applied to hydrogen uptake and release from tungsten

Simulating the implantation and thermal desorption evolution in a reaction-diffusion model requires solving a set of coupled differential equations that describe the trapping and release of atomic species in Plasma Facing Materials (PFMs). These fundamental equations are well outlined by the Tritium Migration Analysis Program (TMAP) which can model systems with no more than three active traps per atomic species. To overcome this limitation, we have developed a Pseudo Trap and Temperature Partition (PTTP) scheme allowing us to lump multiple inactive traps into one pseudo trap, simplifying the system of equations to be solved. For all temperatures, we show the trapping of atoms from solute is exactly accounted for when using a pseudo trap. However, a single effective pseudo trap energy can not well replicate the release from multiple traps, each with its own detrapping energy. However, atoms held in a high energy trap will remain trapped at relatively low temperatures, and thus there is a temperature range in which release from high energy traps is effectively inactive. By partitioning the temperature range into segments, a pseudo trap can be defined for each segment to account for multiple high energy traps that are actively trapping but are effectively not releasing atoms. With increasing temperature, as in controlled thermal desorption, the lowest energy trap is nearly emptied and can be removed from the set of coupled equations, while the next higher energy trap becomes an actively releasing trap. Each segment is thus calculated sequentially, with the last time step of a given segment solution being used as an initial input for the next segment as only the pseudo and actively releasing traps are modeled. This PTTP scheme is then applied to experimental thermal desorption data for tungsten (W) samples damaged with heavy ions, which display six distinct release peaks during thermal desorption. Without modifying the TMAP7 source code the PTTP scheme is shown to successfully model the D retention in all six traps. In conclusion, we demonstrate the full reconstruction from the plasma implantation phase through the controlled thermal desorption phase with detrapping energies near 0.9, 1.1, 1.4, 1.7, 1.9 and 2.1 eV for a W sample damaged at room temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium causing disappearance of a/2<111> dislocation loops in binary Fe-Cr ferritic alloys

In this work, single and dual-beam self-ion irradiations were performed at 500°C on ultra-high purity Fe14%Cr alloy to ~0.33 displacements-per-atom (dpa), and 0 or 3030 atomic-parts-per-million (appm) helium/dpa, respectively. Using transmission electron microscopy, we reveal that helium can drastically modify the dislocation loop Burgers vector in Fe-Cr alloys. Helium co-implantation caused complete disappearance of a/2<111> type dislocation loops, and the microstructure consisted of only a<100> loops. Conversely, a/2<111> type loops were predominant without He co-implantation. The total loop density remained largely unaffected. The results strikingly contrast literature asserting that helium stabilizes a/2<111> type loops in bcc Fe alloys, based on low temperature irradiations. Collectively analyzing the results with literature suggest that the small positive interaction between helium and self-interstitial atoms (SIA) in Fe predicted by atomistic simulations maybe insufficient to holistically explain the dislocation loop microstructure development in presence of helium. Helium-SIA positive binding inadvertently implies elevated a/2<111> loop fraction and higher loop densities that the present results contradict. Helium induced high cavity density causing a preferential loss of highly glissile <111> clusters, leaving the matrix saturated with <100> type clusters is proposed as a potential mechanism. Further, the in-situ irradiations combined with Burgers vector analysis strengthened the evidence of Cr-induced dislocation loop mobility reduction that appears to stabilize the a/2<111> type loops and causes higher loop densities in Fe-Cr alloys.

36 MATERIALS SCIENCE↗

Influence of surface pattern on the biological properties of Ti grade 2

Highlights: • Laser modification causes changes in chemical composition of the surface. • Laser treatment creates roughness in a range from nano- to micrometers. • The surface modification presented results in a multimodal topography. • A hierarchical topography promotes protein adsorption. - Abstract: This paper presents a detailed characterization of Ti surface geometries as produced by non-contact laser functionalization and its impact on the process of protein adsorption. The proposed surface modification is designed for the local treatment of implantable devices with original roughness. In this work, titanium plates were initially modified by the two most common mechano-chemical treatments, shot peening and acid etching. The material under study was next functionalized DLIL (Direct Laser Interference Lithography) in order to obtained two different surface patterns: grooves and islands. The modified surfaces were characterized in terms of their shape, roughness, wettability, surface energy and chemical composition. For this purpose, the following methods were used: scanning electron microscopy, optical profilometry, atomic force microscopy, contact angle measurements, and X-ray photoelectron spectroscopy. Protein adsorption tests were conducted to consider the potential of the proposed methodology in biomedical applications and to compare the influence of the two different surface patterns on the initial state of ossointegration. To this end, XPS and FTIR studies were conducted. The systematic analysis presented will be useful when selecting an appropriate surface geometry for the local surface functionalization of implantable devices.

36 MATERIALS SCIENCE↗

Radiation-induced swelling and radiation-induced segregation & precipitation in dual beam irradiated Ferritic/Martensitic HT9 steel

Highlights: • The depth-dependence of radiation-induced cavities was characterized in self-ion irradiated HT9 co-implanted with He. • The injected interstitial effect was revealed to suppress cavity swelling in the vicinity of the damage peak. • ChemiSTEM elemental maps revealed the segregation of Ni at cavity surfaces and its possible synergistic influence on swelling was discussed. - Abstract: Ferritic/Martensitic HT9 steel was irradiated at 432 °C to 16.6 displacements per atom (dpa) (at the depth of 600 nm) using a defocused beam of 5 MeV Fe{sup ++} ions, while co-implanted with 3.22 appm He at the same depth. The helium concentration profile was designed so to follow the damage curve with a 0.22 appm He/dpa ratio at the depth from 300 to 1000 nm in the material. The depth-dependence of the cavity size and number density were characterized by both transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) imaging methods. A comparison between the two techniques was done showing good agreement. Cavity number density and the resulting swelling were found to be suppressed by the injected interstitial effect in the vicinity of the ion induced damage peak. The region between 300 and 750 nm depth which excludes the injected interstitial effect was thus proposed for improved cavity swelling analysis. The swelling ratio in this region was found to be ~(0.86–1.02) × 10{sup − 2}%/dpa. In addition, ChemiSTEM characterization revealed radiation-induced segregation occurring throughout the irradiated region and precipitation of G-phase particles. Segregation of Ni to cavity surfaces was also observed and its possible synergistic influence on swelling was discussed.

36 MATERIALS SCIENCE↗

Microstructural analysis of undoped and moderately Sc-doped TiO2 anatase nanoparticles using Scherrer equation and Debye function analysis

Highlights: • UV light sensitive undoped and moderate Sc-doped anatase nanocrystallites were prepared without post-synthesis annealing. • Elongated nanocrystallites were found by Scherrer equation and Debye Function Analysis applied to XRD data and also HRTEM. • 4 at.% Sc doping reduced the amount of Ti vacancies by half. • Doping showed ~0.3% growth of lattice parameters. - Abstract: UV light sensitive undoped and moderate (4 at.%) Sc-doped anatase nanocrystallites were prepared by an efficient and environmentally benign method based on homogeneous hydrolysis of TiOSO{sub 4} and Sc{sub 2}(C{sub 2}O{sub 4}){sub 3.5}H{sub 2}O aqueous solutions using urea as a precipitation agent, without post-synthesis calcination or annealing. X-ray diffraction study of the obtained powders revealed single phase anatase in both samples. Two different methods were applied to estimate the anatase crystallite size and shape from the X-ray diffraction data. The first one is based on the more conventional Scherrer equation (as implanted in GSAS-II program) while the second one is based on Debye function analysis (as implanted in DUBUSSY suite version 2.2), which is considered to be more adequate for nanocrystallites. Although each program has its own shape models, both methods indicated similar results of elongated nanocrystallite geometry for Sc-doped TiO{sub 2}: (i) GSAS-II confirmed ellipsoid shape with equatorial size of 5.1(0) nm and axial size of 6.8(0), (ii) DEBUSSY suite 2.2 showed cylinder shape with diameter of equivalent circle in the ab-plane, D{sub ab} = 4.9(1.0) nm and crystallite length along the c-axis, L{sub c} = 5.4(3.2) nm. For the undoped TiO{sub 2} sample, equatorial size of 5.5(0) nm and axial size of 7.3(0) nm for the ellipsoid shape was determined according to GSAS-II, while D{sub ab} = 5.5(1.3) nm and L{sub c} = 6.0(2.2) nm for the cylinder shape was determined by DEBUSSY suite 2.2. These outcomes were found to corroborate with HRTEM analysis. Doping with 4 at.% Sc caused ~0.3% growth of lattice parameters from a = 3.7979 [4] Å, c = 9.4995 [9] Å for the undoped sample to a = 3.8110 [7] Å, c = 9.5274 [16] Å for the moderately Sc doped sample, while reduction in the Ti vacancies by half was confirmed by both methods. The introducing of Sc as electronically active secondary species into the crystal lattice of TiO{sub 2} can greatly alter its optical absorption. The incorporation of Sc into the crystal lattice of TiO{sub 2} favors the substitution of Ti, as both have approximately the same ionic size, and generates surface oxygen vacancies which can act as trapping center for the photogenerated electrons and reduce the recombination of electron–hole pairs. We can expect Sc doped TiO{sub 2} nanomaterials to have applications as effective photocatalysts for selective photocatalytic oxidation of various environmental organic pollutants.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

Interplay of strain and phase evolution of laser powder bed fusion Ti–6Al–4V

While additive manufacturing (AM) provides a method of producing geometrically complex and highly detailed structures, the generation of residual strain in AM processes like laser powder bed fusion (L-PBF) can negatively impact performance-enabling properties. In applications such as orthopedic implants, specific performance windows require optimized microstructures in order to obtain desirable properties from multi-phase alloys like Ti–6Al–4V. This research aims to quantify the microscale origins of strain in L-PBF manufactured Ti–6Al–4V by understanding how strain is distributed at the grain and sub-grain scale, the interplay between phase evolution and strain, and examining post-processing strain relief strategies to control these features. Model spinal cage implants were manufactured from Ti–6Al–4V powder via L-PBF and then subjected to strain relieving heat treatment cycles above and below the Ti–6Al–4V β transus as a function of time and cooling rate. Residual strain was then studied via high resolution electron backscatter diffraction (HR-EBSD), and 2D strain maps with sub-micron resolution were generated for each post-processing state. It was found that macroscale thermal strains decreased with heat treatment time, but additional contributions from phase stabilizing residual strains retained primarily in the α' grains as lattice distortive strain remained. Additionally, the retention of β phase significantly changed the strain and dislocation distribution while reducing overall residual strain. In conclusion, these results were validated and reinforced with 3D mesoscopic micromechanical modeling of strain behavior across simulated microstructures, confirming that the local lattice dilation of α’ martensite is a primary contributor of microscale strain generation and retention in L-PBF Ti–6Al–4V.

36 MATERIALS SCIENCE↗

Processes controlling helium bubble dynamics at varying temperatures in simulated radioactive materials

Alpha-radiation damage is known to degrade materials exposed to harsh radiation environments via swelling and embrittlement by nano-scale helium bubbles. How these bubbles grow under varying temperature is essential to understanding and predicting material failure and optimization. Using in situ X-ray scattering, we probed ≈1012 bubbles before, during and after annealing at different temperatures in He-implanted aluminum to reveal a critical growth activation temperature that depends strongly on the helium implantation conditions. An analysis of the data aided by our molecular dynamics simulations identifies multiple temperature-dependent bubble growth mechanisms above and below the critical growth activation temperature. Moreover, the irreversible bubble growth that occurs after annealing for ≈4 h was evaluated using dislocation dynamics and found to negligibly affect the yield strength but may affect subsequent bubble growth at temperature. These in situ results provide valuable insight into bubble growth never observed before and reveal, for the first time, bubble shrinkage after cooling.

36 MATERIALS SCIENCE↗

Superlattice-enhanced silicon soft X-ray and charged particle detectors with nanosecond time response

Here, silicon detectors are an essential measurement tool for Inertial Confinement Fusion and High-Energy-Density Physics Applications, where temporal response of the order of nanoseconds is essential. Soft X-rays (<1 keV), Ultraviolet light, and low-energy electrons (<10 keV) can provide essential information in diagnosing rapidly changing plasma conditions, but reducing the detector dead layer is essential to improving detector response for these shallowly absorbed particles. This paper details a study of silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2D superlattice, to produce fast detectors that are highly sensitive to shallowly absorbed radiation. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2-layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of high energy deuteron ion beam irradiation on the tensile behavior of HT-9

Ion beam implantations are widely performed to understand the effects of irradiation-induced displacement damage on nuclear structural materials. However, the volume of material that can be investigated is often limited by the maximum energies of accelerator facilitates, leading to a limitation in the thickness of samples whose mechanical properties can be evaluated. The Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron offers a wide range of ions and energies, allowing for material ion implantations at larger scales than typical. Four HT-9 SS-J-geometry tensile specimens were polished and then irradiated with deuterons at the 88-Inch Cyclotron to doses of approximately 0.2 dpa prior to small scale tensile testing. Here, the results from this study show irradiation hardening characterized by the tensile test results and black dot irradiation defects. Additionally, a comprehensive look at low temperature irradiations of high-Cr F/M steels is presented and our results show agreement with the available data.

36 MATERIALS SCIENCE↗

Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

Environmental Molecular Sciences Laboratory↗