Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

In situ biaxial rotation at low-temperatures in high magnetic fields

We report the design, construction, and characterization of a biaxial sample rotation stage for use in a cryogenic system for orientation-dependent studies of anisotropic electronic transport phenomena at low temperatures and high magnetic fields. Our apparatus allows for continuous rotation of a sample about two axes, both independently and simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructural evolution of rapidly solidified hypoeutectic Al 10Cu alloy during non-isothermal annealing transients induced by nano-second laser pulses

The evolution of characteristic nonequilibrium features presenting in morphologically distinct regions of rapid solidification (RS) microstructures in a hypoeutectic Al—10Cu (atomic %) in response to non-isothermal annealing transients has been studied by transmission electron microscopy (TEM). The capabilities of the Movie-Mode Dynamic TEM (MM-DTEM) instrument were used to expose select regions of the RS microstructure to sequences of rapid heating and cooling transients induced by nanosecond laser pulses while permitting in-situ observation. Partial melting, microstructural scale coarsening, morphological changes of the nonequilibrium features in the multi-phase RS microstructure, and solid-state phase transformation were observed. Heterogeneous nucleation of nanoscale θ-Al 2 Cu phase involved metastable supersaturated α-Al and the θ'-Al 2 Cu phases, establishing different sets of orientation relationships for the stable θ-Al 2 Cu and α-Al phases. Replacement of banded morphology grains that formed under conditions driven farthest from equilibrium by an equiaxed nanocrystalline structure comprised of α-Al phase, the primary solidification product, and an intergranular network of Al 2 Cu crystals has been attributed to local remelting. Here the experimental approach explored, permitted discovery of mechanistic details of location-specific transformation pathways activated in the multi-phase RS microstructure of hypoeutectic Al—Cu during subsequent nonisothermal transients.

36 MATERIALS SCIENCE↗

A Hybrid HTS/LTS Superconductor Design for High-Field Accelerator Magnets (Final Report)

This paper presents the design, construction, and test results of a hybrid dipole magnet. The inner coils were of second generation (2G) high-temperature superconductor (HTS) ReBCO tape and the outer coils were of low-temperature superconductor (LTS) Nb 3 Sn Rutherford cable. The HTS and LTS coils were independently powered and protected using different power supplies. The HTS coils were quenched many times with no degradation in performance observed. The hybrid field reached ~8.6 T, which is believed to be a record for a hybrid dipole. The maximum field was limited by the stable operation of the leads in the LTS coil at 8000 A. The HTS coils were independently ramped to 800 A, and the LTS coils to 10,000 A. With improved leads and instrumentation, this hybrid dipole is expected to produce over 13 T when the ReBCO tape in the HTS coil is aligned nearly parallel to the field. One major purpose of this program was to perform magnetization studies in the coils made with the HTS tape. Magnetization-induced field errors are expected to be small when the field is nearly parallel to the wide face of the tape. The magnetization measurements were performed at 77 K with the two racetrack coils in two orientations, with field predominantly either parallel or perpendicular to the wide face of the HTS tape. In addition, measurements were also performed at 4 K in different background fields provided by the outer Nb3Sn coils. This paper will summarize the magnetization measurements and present the quenching experience of the HTS coils in this hybrid magnet system.

99 GENERAL AND MISCELLANEOUS↗

Optical phase measuring sensors for automated rendezvous and capture

A technique is described for sensing relative spatial orientations of approach and target vehicles, using optical phase mensuration (in the interferometric sense, as opposed to LIDAR), in place of the more conventional intensity, image, or transit time measurements. This approach permits the parameters to be measured with great accuracy with relatively simple, small sensors having no moving components. A suite of sensors operating on this principle can produce all desired data using either active detection on the target or passive retroreflection to the detectors on the approach vehicle. These optical phase measurements can be applied to determine bearing angle (location of the target vehicle in the approach vehicle coordinates), range, and attitude (orientation of the target vehicle with respect to the line-of-sight). The first two quantities require the approach vehicle to project a modulated interference pattern into space. The bearing angle is determined for a selected point on the target by measuring the phase of the interference pattern at that point using either a detector on the target or a retroreflector on the target and a detector at the transmitter. The range is found by measuring differential bearing angles to predetermined relative instrumentation sites. Two interferometers, a coarse and a fine ranger are required to resolve the 2pi ambiguity.

Metheny, Wayne↗

Tetrahedron Formation Control

Spacecraft flying in tetrahedron formations are excellent instrument platforms for electromagnetic and plasma studies. A minimum of four spacecraft - to establish a volume - is required to study some of the key regions of a planetary magnetic field. The usefulness of the measurements recorded is strongly affected by the tetrahedron orbital evolution. This paper considers the preliminary development of a general optimization procedure for tetrahedron formation control. The maneuvers are assumed to be impulsive and a multi-stage optimization method is employed. The stages include targeting to a fixed tetrahedron orientation, rotating and translating the tetrahedron and/or varying the initial and final times. The number of impulsive maneuvers citn also be varied. As the impulse locations and times change, new arcs are computed using a differential corrections scheme that varies the impulse magnitudes and directions. The result is a continuous trajectory with velocity discontinuities. The velocity discontinuities are then used to formulate the cost function. Direct optimization techniques are employed. The procedure is applied to the Magnetospheric Multiscale Mission (MMS) to compute preliminary formation control fuel requirements.

Guzman, Jose J.↗

Enhancing Radiative Transfer Models for Optimized Assimilation of Microwave and Radar Observations

Radiative transfer models are extensively used for the assimilation of satellite observations into NWP models as well as retrieving geophysical products from satellite measurements. The Community Radiative Transfer Model (CRTM) is a community model developed by NOAA JCSDA and widely used for different purposes requiring RT calculations. CRTM requires bulk optical properties of hydrometeors in the form of lookup tables in order to perform all-sky RT calculations. However, the current cloud scattering lookup tables in CRTM assume spherical shapes for all frozen hydrometeors, whereas actual clouds contain frozen particles with diverse shapes. The first part of this talk presents the implementation and validation of a comprehensive Discrete Dipole Approximation (DDA) cloud scattering database into CRTM, specifically targeting microwave frequencies. The DDA technique proves effective in simulating the optical properties of non-spherical hydrometeors in the microwave region. The original DDA database assumes total random orientation in calculating single scattering properties. To generate the required mass scattering parameters for CRTM, the single scattering properties and water content dependent particle size distributions are used. The evaluation of results involved a collocated dataset comprising short-term forecasts from the Integrated Forecast System of the European Center for Medium-Range Weather Forecasts and satellite microwave data. The findings demonstrate that the DDA lookup tables significantly reduce discrepancies between simulated and observed values when compared to the Mie tables. Passive instruments lack the ability to provide vertically resolved measurements of clouds and precipitation, which can be obtained by active radar instruments. However, incorporating these active measurements into data assimilation systems presents challenges due to the absence of fast forward radiative transfer models and difficulties in error modeling. The second part of the talk focuses on the development, evaluation, and sensitivity analysis of a forward radar model integrated into CRTM. The forward radar model utilizes scattering properties obtained from hydrometeor lookup tables generated using the discrete dipole approximation. By utilizing CRTM instrument-specific coefficients, the model can calculate both reflectivity and attenuated reflectivity for any given radar instrument and zenith angles. Evaluation using CloudSat measurements demonstrates a strong agreement between simulations and observations when the input profiles of hydrometeors align with the measured reflectivity profiles.

Isaac Moradi↗

Optimizing Assimilation of Microwave and Radar Observations in the NWP Models

Radiative transfer models are extensively used for the assimilation of satellite observations into NWP models as well as retrieving geophysical products from satellite measurements. The Community Radiative Transfer Model (CRTM) is a community model developed by NOAA JCSDA and widely used for different purposes requiring RT calculations. CRTM requires bulk optical properties of hydrometeors in the form of lookup tables in order to perform all-sky RT calculations. However, the current cloud scattering lookup tables in CRTM assume spherical shapes for all frozen hydrometeors, whereas actual clouds contain frozen particles with diverse shapes. The first part of this talk presents the implementation and validation of a comprehensive Discrete Dipole Approximation (DDA) cloud scattering database into CRTM, specifically targeting microwave frequencies. The DDA technique proves effective in simulating the optical properties of non-spherical hydrometeors in the microwave region. The original DDA database assumes total random orientation in calculating single scattering properties. To generate the required mass scattering parameters for CRTM, the single scattering properties and water content dependent particle size distributions are used. The evaluation of results involved a collocated dataset comprising short-term forecasts from the Integrated Forecast System of the European Center for Medium-Range Weather Forecasts and satellite microwave data. The findings demonstrate that the DDA lookup tables significantly reduce discrepancies between simulated and observed values when compared to the Mie tables. Passive instruments lack the ability to provide vertically resolved measurements of clouds and precipitation, which can be obtained by active radar instruments. However, incorporating these active measurements into data assimilation systems presents challenges due to the absence of fast forward radiative transfer models and difficulties in error modeling. The second part of the talk focuses on the development, evaluation, and sensitivity analysis of a forward radar model integrated into CRTM. The forward radar model utilizes scattering properties obtained from hydrometeor lookup tables generated using the discrete dipole approximation. By utilizing CRTM instrument-specific coefficients, the model can calculate both reflectivity and attenuated reflectivity for any given radar instrument and zenith angles. Evaluation using CloudSat measurements demonstrates a strong agreement between simulations and observations when the input profiles of hydrometeors align with the measured reflectivity profiles.

Isaac Moradi↗

Assimilation of Spaceborne Microwave and Radar Observations

Radiative transfer models are extensively used for the assimilation of satellite observations into NWP models as well as retrieving geophysical products from satellite measurements. The Community Radiative Transfer Model (CRTM) is a community model developed by NOAA JCSDA and widely used for different purposes requiring RT calculations. CRTM requires bulk optical properties of hydrometeors in the form of lookup tables in order to perform all-sky RT calculations. However, the current cloud scattering lookup tables in CRTM assume spherical shapes for all frozen hydrometeors, whereas actual clouds contain frozen particles with diverse shapes. The first part of this talk presents the implementation and validation of a comprehensive Discrete Dipole Approximation (DDA) cloud scattering database into CRTM, specifically targeting microwave frequencies. The DDA technique proves effective in simulating the optical properties of non-spherical hydrometeors in the microwave region. The original DDA database assumes total random orientation in calculating single scattering properties. To generate the required mass scattering parameters for CRTM, the single scattering properties and water content dependent particle size distributions are used. The evaluation of results involved a collocated dataset comprising short-term forecasts from the Integrated Forecast System of the European Center for Medium-Range Weather Forecasts and satellite microwave data. The findings demonstrate that the DDA lookup tables significantly reduce discrepancies between simulated and observed values when compared to the Mie tables. Passive instruments lack the ability to provide vertically resolved measurements of clouds and precipitation, which can be obtained by active radar instruments. However, incorporating these active measurements into data assimilation systems presents challenges due to the absence of fast forward radiative transfer models and difficulties in error modeling. The second part of the talk focuses on the development, evaluation, and sensitivity analysis of a forward radar model integrated into CRTM. The forward radar model utilizes scattering properties obtained from hydrometeor lookup tables generated using the discrete dipole approximation. By utilizing CRTM instrument-specific coefficients, the model can calculate both reflectivity and attenuated reflectivity for any given radar instrument and zenith angles. Evaluation using CloudSat measurements demonstrates a strong agreement between simulations and observations when the input profiles of hydrometeors align with the measured reflectivity profiles.

Isaac Moradi↗

Physician Evaluation of Internet Health Information on Proton Therapy for Prostate Cancer

Purpose: Many patients considering prostate cancer (PCa) treatment options report seeking proton beam therapy (PBT) based in part on information readily available on the Internet. There is, however, potential for considerable variation in Internet health information (IHI). We thus evaluated the characteristics, quality, and accuracy of IHI on PBT for PCa. Methods and Materials: We undertook a qualitative research study using snowball-purposive sampling in which we evaluated the top 50 Google search results for “proton prostate cancer.” Quality was evaluated on a 5-point scale using the validated 15-question DISCERN instrument. Accuracy was evaluated by comparing IHI with the best available evidence. Results: Thirty-seven IHI websites were included in the final sample. These websites most frequently were patient information/support resources (46%), were focused exclusively on PBT (51%), and had a commercial affiliation (38%). There was a significant difference in quality according to the type of IHI. Substantial inaccuracies were noted in the study sample compared with best available or contextual evidence. Conclusions: There are shortcomings in quality and accuracy in consumer-oriented IHI on PBT for PCa. Providers must be prepared to educate patients how to critically evaluate IHI related to PBT for PCa to best inform their treatment decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ray-wave approximation for calculating laser radiation scattering by a transparent dielectric spheroidal particle

A theoretical model is developed and an algorithm is proposed for calculating far-field light scattering by a transparent dielectric particle significantly larger than a wavelength. The accuracy of this algorithm is close to that of the discrete dipole approximation. The calculation time for this algorithm in the case of particles with the size parameter higher than 50 is much lower than that for the discrete dipole approximation. Scattering diagrams for spheroidal particles of different sizes, orientations and refractive indices are calculated. The proposed algorithm has a great potential for quick calculations of parameters of light scattering by large biological particles such as erythrocytes and their aggregates, bacteria, etc. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Torsional force microscopy of van der Waals moirés and atomic lattices

In a stack of atomically thin van der Waals layers, introducing interlayer twist creates a moiré superlattice whose period is a function of twist angle. Changes in that twist angle of even hundredths of a degree can dramatically transform the system’s electronic properties. Setting a precise and uniform twist angle for a stack remains difficult; hence, determining that twist angle and mapping its spatial variation is very important. Techniques have emerged to do this by imaging the moiré, but most of these require sophisticated infrastructure, time-consuming sample preparation beyond stack synthesis, or both. In this work, we show that torsional force microscopy (TFM), a scanning probe technique sensitive to dynamic friction, can reveal surface and shallow subsurface structure of van der Waals stacks on multiple length scales: the moirés formed between bi-layers of graphene and between graphene and hexagonal boron nitride (hBN) and also the atomic crystal lattices of graphene and hBN. In TFM, torsional motion of an Atomic Force Microscope (AFM) cantilever is monitored as it is actively driven at a torsional resonance while a feedback loop maintains contact at a set force with the sample surface. TFM works at room temperature in air, with no need for an electrical bias between the tip and the sample, making it applicable to a wide array of samples. It should enable determination of precise structural information including twist angles and strain in moiré superlattices and crystallographic orientation of van der Waals flakes to support predictable moiré heterostructure fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, August 2004

Topics covered include: Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications; Software and Algorithms for Biomedical Image Data Processing and Visualization; Rapid Chemometric Filtering of Spectral Data; Prioritizing Scientific Data for Transmission; Determining Sizes of Particles in a Flow from DPIV Data; Faster Processing for Inverting GPS Occultation Data; FPGA-Based, Self-Checking, Fault-Tolerant Computers; Ultralow-Power Digital Correlator for Microwave Polarimetry; Grounding Headphones for Protection Against ESD; Lightweight Stacks of Direct Methanol Fuel Cells; Highly Efficient Vector-Inversion Pulse Generators; Estimating Basic Preliminary Design Performances of Aerospace Vehicles; Framework for Development of Object-Oriented Software; Analyzing Spacecraft Telecommunication Systems; Collaborative Planning of Robotic Exploration; Tools for Administration of a UNIX-Based Network; Preparing and Analyzing Iced Airfoils; Evaluating Performance of Components; Fuels Containing Methane of Natural Gas in Solution; Direct Electrolytic Deposition of Mats of MnxOy Nanowires; Bubble Eliminator Based on Centrifugal Flow; Inflatable Emergency Atmospheric-Entry Vehicles; Lightweight Deployable Mirrors with Tensegrity Supports; Centrifugal Adsorption Cartridge System; Ultrasonic Apparatus for Pulverizing Brittle Material; Transplanting Retinal Cells using Bucky Paper for Support; Using an Ultrasonic Instrument to Size Extravascular Bubbles; Coronagraphic Notch Filter for Raman Spectroscopy; On-the-Fly Mapping for Calibrating Directional Antennas; Working Fluids for Increasing Capacities of Heat Pipes; Computationally-Efficient Minimum-Time Aircraft Routes in the Presence of Winds; Liquid-Metal-Fed Pulsed Plasma Thrusters; Personal Radiation Protection System; and Attitude Control for a Solar-Sail Spacecraft.

Source record↗

In-Orbit Instrument-Pointing Calibration Using the Moon as a Target

A method was developed for in-orbit measurement of the relative pointing of spectrometer channels, and the relationship between the spectrometer channels and the spacecraft coordinate system. In this innovation, individual scans of the Moon, from the three channels, were used to determine the position of the center of the Moon, with respect to channel-specific coordinates. Comparing the coordinates of the center of the Moon, obtained from individual channels, yields the relative pointing between the channels. Comparing the coordinates of the center of the Moon in one of the channels with the Moon ephemerides and with the spacecraft coordinate measurement, using the onboard star tracker, yields the relative orientation of the channel optical axes with respect to the spacecraft coordinates.

Abramovici, Alex↗

Overview of SIM external calibration

Like all astrometric instruments, the Space Interferometry Mission (SIM) suffers from field-dependent errors requiring calibration. Diffraction effects in the delay line, polarization rotations on comer cubes, and beam walk across imperfect optics, all contribute to field-distortion that is significantly larger than is acceptable. The bulk of the systematic error is linear across the field - that is, it results in a magnification error. We show that the linear terms are inconsequential to the performance of SIM because they are inseparable from baseline length and orientation errors. One approach to calibrating the higher-order terms is to perform external' calibration; that is, SIM periodically makes differential measurements of a field of bright stars whose positions are not precisely known. We describe the requirements and constraints on the external calibration process and lay the groundwork for a specific procedure detailed in accompanying papers.

Space↗

HERRO: A Science-Oriented Strategy for Crewed Missions Beyond LEO

This paper presents an exploration strategy for human missions beyond Low Earth Orbit (LEO) and the Moon that combines the best features of human and robotic spaceflight. This "Human Exploration using Real-time Robotic Operations" (HERRO) strategy refrains from placing humans on the surfaces of the Moon and Mars in the near-term. Rather, it focuses on sending piloted spacecraft and crews into orbit around exploration targets of interest, such as Mars, and conducting astronaut exploration of the surfaces using telerobots and remotely controlled systems. By eliminating the significant communications delay with Earth due to the speed of light limit, teleoperation provides scientists real-time control of rovers and other sophisticated instruments, in effect giving them a "virtual presence" on planetary surfaces, and thus expanding the scientific return at these destinations. It also eliminates development of the numerous man-rated landers, ascent vehicles and surface systems that are required to land humans on planetary surfaces. The propulsive requirements to travel from LEO to many destinations with shallow gravity-wells in the inner solar system are quite similar. Thus, a single spacecraft design could perform a variety of missions, including orbit-based surface exploration of the Moon, Mars and Venus, and rendezvous with Near Earth Asteroids (NEAs), as well as Phobos and Deimos. Although HERRO bypasses many of the initial steps that have been historically associated with human space exploration, it opens the door to many new destinations that are candidates for future resource utilization and settlement. HERRO is a first step that takes humans to exciting destinations beyond LEO, while expanding the ability to conduct science within the inner solar system.

Schmidt, George R.↗

A design and implementation methodology for diagnostic systems

A methodology for design and implementation of diagnostic systems is presented. Also discussed are the advantages of embedding a diagnostic system in a host system environment. The methodology utilizes an architecture for diagnostic system development that is hierarchical and makes use of object-oriented representation techniques. Additionally, qualitative models are used to describe the host system components and their behavior. The methodology architecture includes a diagnostic engine that utilizes a combination of heuristic knowledge to control the sequence of diagnostic reasoning. The methodology provides an integrated approach to development of diagnostic system requirements that is more rigorous than standard systems engineering techniques. The advantages of using this methodology during various life cycle phases of the host systems (e.g., National Aerospace Plane (NASP)) include: the capability to analyze diagnostic instrumentation requirements during the host system design phase, a ready software architecture for implementation of diagnostics in the host system, and the opportunity to analyze instrumentation for failure coverage in safety critical host system operations.

Williams, Linda J. F.↗

Summary: Experimental validation of real-time fault-tolerant systems

Testing and validation of real-time systems is always difficult to perform since neither the error generation process nor the fault propagation problem is easy to comprehend. There is no better substitute to results based on actual measurements and experimentation. Such results are essential for developing a rational basis for evaluation and validation of real-time systems. However, with physical experimentation, controllability and observability are limited to external instrumentation that can be hooked-up to the system under test. And this process is quite a difficult, if not impossible, task for a complex system. Also, to set up such experiments for measurements, physical hardware must exist. On the other hand, a simulation approach allows flexibility that is unequaled by any other existing method for system evaluation. A simulation methodology for system evaluation was successfully developed and implemented and the environment was demonstrated using existing real-time avionic systems. The research was oriented toward evaluating the impact of permanent and transient faults in aircraft control computers. Results were obtained for the Bendix BDX 930 system and Hamilton Standard EEC131 jet engine controller. The studies showed that simulated fault injection is valuable, in the design stage, to evaluate the susceptibility of computing sytems to different types of failures.

Iyer, R. K.↗

Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

Nowak, Maria↗