Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Detection of special nuclear materials with the associate particle technique

In the frame of the French trans-governmental R and D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive assay of mechanical components using gamma-rays and thermal neutrons

This work presents the results obtained in the inspection of several mechanical components through neutron and gamma-ray transmission radiography. The 4.46 Multiplication-Sign 10{sup 5} n.cm{sup -2}.s{sup -1} thermal neutron flux available at the main port of the Argonauta research reactor in Instituto de Engenharia Nuclear has been used as source for the neutron radiographic imaging. The 412 keV {gamma}-ray emitted by {sup 198}Au, also produced in that reactor, has been used as interrogation agent for the gamma radiography. Imaging Plates - IP specifically designed to operate with thermal neutrons or with X-rays have been employed as detectors and storage devices for each of these radiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrical conductivity in oxygen-deficient phases of tantalum pentoxide from first-principles calculations

We apply first-principles density-functional theory (DFT) calculations, ab-initio molecular dynamics, and the Kubo-Greenwood formula to predict electrical conductivity in Ta{sub 2}O{sub x} (0 ≤ x ≤ 5) as a function of composition, phase, and temperature, where additional focus is given to various oxidation states of the O monovacancy (V{sub O}{sup n}; n = 0,1+,2+). In the crystalline phase, our DFT calculations suggest that V{sub O}{sup 0} prefers equatorial O sites, while V{sub O}{sup 1+} and V{sub O}{sup 2+} are energetically preferred in the O cap sites of TaO{sub 7} polyhedra. Our calculations of DC conductivity at 300 K agree well with experimental measurements taken on Ta{sub 2}O{sub x} thin films (0.18 ≤ x ≤ 4.72) and bulk Ta{sub 2}O{sub 5} powder-sintered pellets, although simulation accuracy can be improved for the most insulating, stoichiometric compositions. Our conductivity calculations and further interrogation of the O-deficient Ta{sub 2}O{sub 5} electronic structure provide further theoretical basis to substantiate V{sub O}{sup 0} as a donor dopant in Ta{sub 2}O{sub 5}. Furthermore, this dopant-like behavior is specific to the neutral case and not observed in either the 1+ or 2+ oxidation states, which suggests that reduction and oxidation reactions may effectively act as donor activation and deactivation mechanisms, respectively, for V{sub O}{sup n} in Ta{sub 2}O{sub 5}.

36 MATERIALS SCIENCE↗

Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

Miniature (<few cm{sup 3}) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm{sup 3} as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm{sup 3} volume) test setup based on the M{sub z} magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nondestructive millimeter wave imaging and spectroscopy using dielectric focusing probes

A tool for interrogating objects over a wide band of frequencies with subwavelength resolution at small standoff distances (near field region) in the transmission mode using a single source and detector measurement setup in the millimeter wave band is presented. The design utilizes optics like principles for guiding electromagnetic millimeter waves from large cross-sectional areas to considerably smaller sub-wavelength areas. While plano-convex lenses can be used to focus waves to a fine resolution, they usually require a large stand-off distance thus resulting in alignment and spacing issues. The design procedure and simulation analysis of the focusing probes are presented in this study along with experimental verification of performance and imaging and spectroscopy examples. Nondestructive evaluation will find benefit from such an apparatus including biological tissue imaging, electronic package integrity testing, composite dielectric structure evaluation for defects and microfluidic sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal history sensors for non-destructive temperature measurements in harsh environments

The operating temperature is a critical physical parameter in many engineering applications, however, can be very challenging to measure in certain environments, particularly when access is limited or on rotating components. A new quantitative non-destructive temperature measurement technique has been proposed which relies on thermally induced permanent changes in ceramic phosphors. This technique has several distinct advantages over current methods for many different applications. The robust ceramic material stores the temperature information allowing long term thermal exposures in harsh environment to be measured at a convenient time. Additionally, rare earth dopants make the ceramic phosphorescent so that the temperature information can be interpreted by automated interrogation of the phosphorescent light. This technique has been demonstrated by application of YAG doped with dysprosium and europium as coatings through the air-plasma spray process. Either material can be used to measure temperature over a wide range, namely between 300°C and 900°C. Furthermore, results show that the material records the peak exposure temperature and prolonged exposure at lower temperatures would have no effect on the temperature measurement. This indicates that these materials could be used to measure peak operating temperatures in long-term testing.

36 MATERIALS SCIENCE↗

Improving the reliability of automated non-destructive inspection

In automated NDE a region of an inspected component is often interrogated several times, be it within a single data channel, across multiple channels or over the course of repeated inspections. The systematic combination of these diverse readings is recognized to provide a means to improve the reliability of the inspection, for example by enabling noise suppression. Specifically, such data fusion makes it possible to declare regions of the component defect-free to a very high probability whilst readily identifying indications. Registration, aligning input datasets to a common coordinate system, is a critical pre-computation before meaningful data fusion takes place. A novel scheme based on a multiobjective optimization is described. The developed data fusion framework, that is able to identify and rate possible indications in the dataset probabilistically, based on local data statistics, is outlined. The process is demonstrated on large data sets from the industrial ultrasonic testing of aerospace turbine disks, with major improvements in the probability of detection and probability of false call being obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A loss-based, magnetic field sensor implemented in a ferrofluid infiltrated microstructured polymer optical fiber

We report an in-fiber magnetic field sensor based on magneto-driven optical loss effects, while being implemented in a ferrofluid infiltrated microstructured polymer optical fiber. We demonstrate that magnetic field flux changes up to 2000 gauss can be detected when the magnetic field is applied perpendicular to the fiber axis. In addition, the sensor exhibits high polarization sensitivity for the interrogated wavelengths, providing the possibility of both field flux and direction measurements. The underlying physical and guidance mechanisms of this sensing transduction are further investigated using spectrophotometric, light scattering measurements, and numerical simulations, suggesting photonic Hall effect as the dominant physical, transducing mechanism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The role of group index engineering in series-connected photonic crystal microcavities for high density sensor microarrays

We experimentally demonstrate an efficient and robust method for series connection of photonic crystal microcavities that are coupled to photonic crystal waveguides in the slow light transmission regime. We demonstrate that group index taper engineering provides excellent optical impedance matching between the input and output strip waveguides and the photonic crystal waveguide, a nearly flat transmission over the entire guided mode spectrum and clear multi-resonance peaks corresponding to individual microcavities that are connected in series. Series connected photonic crystal microcavities are further multiplexed in parallel using cascaded multimode interference power splitters to generate a high density silicon nanophotonic microarray comprising 64 photonic crystal microcavity sensors, all of which are interrogated simultaneously at the same instant of time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New insights on boundary plasma turbulence and the quasi-coherent mode in Alcator C-Mod using a Mirror Langmuir Probe

A new “Mirror Langmuir Probe” diagnostic, combined with a double-coil scanning magnetic probe, is used to interrogate Alcator C-Mod's quasi-coherent mode (QCM) with unprecedented detail. In ohmic EDA H-modes, the QCM is found to reside in a region of positive radial electric field, with a radial width (∼3 mm) that spans open and closed field line regions. Large amplitude, in-phase sinusoidal bursts (∼100 kHz) in density, electron temperature, and plasma potential are observed, with potential lagging density by ∼16°, producing an outward radial transport velocity of ∼10 m/s. Mode propagation corresponds to the sum of local E × B and electron diamagnetic drift velocities. Poloidal magnetic field fluctuations project to current filaments carrying peak current densities of ∼25 A/cm{sup 2}. An evaluation of parallel electron force balance (Ohm's law) over a fluctuation cycle indicates a significant electromotive component. Interchange drive is also a contributor in the current continuity (vorticity) equation. Thus, the QCM is primarily a separatrix-spanning electron drift-wave with interchange and electromagnetic contributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactive ion etching-assisted surface-enhanced Raman scattering measurements on the single nanoparticle level

Single-nanoparticle surface-enhanced Raman scattering (SERS) measurement is of essential importance for both fundamental research and practical applications. In this work, we develop a class of single-particle SERS approaches, i.e., reactive ion etching (RIE)-assisted SERS measurements correlated with scanning electron microscopy (SEM) strategy (RIE/SERS/SEM), enabling precise and high-resolution identification of single gold nanoparticle (AuNP) in facile and reliable manners. By using AuNP-coated silicon wafer and quartz glass slide as models, we further employ the developed RIE/SERS/SEM method for interrogating the relationship between SERS substrates and enhancement factor (EF) on the single particle level. Together with theoretical calculation using an established finite-difference-time-domain (FDTD) method, we demonstrate silicon wafer as superior SERS substrates, facilitating improvement of EF values.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A compact micro-wave synthesizer for transportable cold-atom interferometers

We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of {sup 87}Rb at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references developed at Laboratoire national de métrologie et d'essais−Systémes de référence temps espace (LNE-SYRTE). In free-running mode, it features a residual phase noise level of −65 dB rad{sup 2} Hz{sup −1} at 10 Hz offset frequency and a white phase noise level in the order of −120 dB rad{sup 2} Hz{sup −1} for Fourier frequencies above 10 kHz. The phase noise effect on the sensitivity of the atomic interferometer is evaluated for diverse values of cycling time, interrogation time, and Raman pulse duration. To our knowledge, the resulting contribution is well below the sensitivity of any demonstrated cold atom inertial sensors based on stimulated Raman transitions. The drastic improvement in terms of size, simplicity, and power consumption paves the way towards field and mobile operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamics of the reaction of C{sub 3}(a{sup 3}Π{sub u}) radicals with C{sub 2}H{sub 2}: A new source for the formation of C{sub 5}H

The reaction C{sub 3}(a{sup 3}Π{sub u}) + C{sub 2}H{sub 2} → C{sub 5}H + H was investigated at collision energy 10.9 kcal mol{sup −1} that is less than the enthalpy of ground-state reaction C{sub 3}(X{sup 1}Σ{sub g}{sup +}) + C{sub 2}H{sub 2} → C{sub 5}H + H. C{sub 3}(a{sup 3}Π{sub u}) radicals were synthesized from 1% C{sub 4}F{sub 6}/He by pulsed high-voltage discharge. The title reaction was conducted in a crossed molecular-beam apparatus equipped with a quadrupole-mass filter. Product C{sub 5}H was interrogated with time-of-flight spectroscopy and synchrotron vacuum-ultraviolet ionization. Reactant C{sub 3}(a{sup 3}Π{sub u}) and product C{sub 5}H were identified using photoionization spectroscopy. The ionization thresholds of C{sub 3}(X{sup 1}Σ{sub g}{sup +}) and C{sub 3}(a{sup 3}Π{sub u}) are determined as 11.6 ± 0.2 eV and 10.0 ± 0.2 eV, respectively. The C{sub 5}H product is identified as linear pentynylidyne that has an ionization energy 8.4 ± 0.2 eV. The title reaction releases translational energy 10.6 kcal mol{sup −1} in average and has an isotropic product angular distribution. The quantum-chemical calculation indicates that the C{sub 3}(a{sup 3}Π{sub u}) radical attacks one of the carbon atoms of C{sub 2}H{sub 2} and subsequently a hydrogen atom is ejected to form C{sub 5}H + H, in good agreement with the experimental observation. As far as we are aware, the C{sub 3}(a{sup 3}Π{sub u}) + C{sub 2}H{sub 2} reaction is investigated for the first time. This work gives an implication for the formation of C{sub 5}H from the C{sub 3}(a{sup 3}Π{sub u}) + C{sub 2}H{sub 2} reaction occurring in a combustion or discharge process of C{sub 2}H{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact deuterium-tritium neutron generator using a novel field ionization source

Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active investigation of material damage under load using micro-CT

Due the growth of composite materials across multiple industries such as Aviation, Wind there is an increasing need to not just standardize and improve manufacturing processes but also to design these materials for the specific applications. One of the things that this translates to is understanding how failure initiates and grows in these materials and at what loads, especially around internal flaws such as voids or features such as ply drops. Traditional methods of investigating internal damage such as CT lack the resolution to resolve ply level damage in composites. Interrupted testing with layer removal can be used to investigate internal damage using microscopy; however this is a destructive method. Advanced techniques such as such as DIC are useful for in-situ damage detection, however are limited to surface information and would not enable interrogating the volume. Computed tomography has become a state of the art technique for metrology and complete volumetric investigation especially for metallic components. However, its application to the composite world is still nascent. This paper demonstrates micro-CT’s capability as a gauge to quantitatively estimate the extent of damage and understand the propagation of damage in PMC composites while the component is under stress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An analytical and numerical study of the nonlinear reflection at a stress-free surface

Implementation of the ultrasonic second harmonic generation has typically been restricted to simple setups such as through-transmission or Rayleigh surface waves. Recent research has evaluated the second harmonic waves generation in P- and SV- waves reflected from a stress-free surface to enable the single-sided interrogation of a specimen. This research considers the second harmonic generation in an aluminum specimen, which is analytically evaluated using an approach based on a perturbation method. Here, the model is chosen to mimic an experimental setup where the longitudinal wave is generated at oblique angle using a wedge transducer. Due to the mode conversion at the interface of the wedge and the specimen, it is necessary to evaluate longitudinal and shear waves, determining all second harmonic waves generated in the bulk and at the stress-free boundary. The theoretically developed model is then implemented in a commercial finite element code, COMSOL, using increasing fundamental wave amplitudes for different values of third order elastic constants. The results of this computational model verify the analytical approach and the proposed measurement setup, taking into account assumptions and approximations of the solution procedure. Furthermore, the computational model is used to draw important conclusions relevant to the experimental setup, including the need to avoid interaction with diffracted waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗