Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Fresnel diffraction imaging of surface nanostructure using coherent resonant x-ray scattering

We investigated surface nanostructures on an antiferromagnet MnBi 2 Te 4 using a novel imaging technique, direct (real)-space and real time coherent x-ray imaging (direct-CXI). This technique has provided new insights into antiferromagnetic textures, including the formation of anti-phase antiferromagnetic (AFM) domains and thermal dynamics of AFM domains and domain walls. While this method produces real-space images of AFM textures without requiring a complex imaging retrieval process, its underlying imaging mechanism has not been fully understood, limiting a deep understanding of AFM textures and the information they contain. By investigating the well-defined structural characteristics of the nanostructures fabricated on MnBi 2 Te 4 ⁠, we elucidate the imaging principle of this novel technique. We find that the observed images can be well explained by the Fresnel diffraction integral. Using a simple model from classical optics, our calculations successfully reproduce the experimentally observed images of the nanostructures. This demonstrates that direct-CXI not only provides straightforward real-space imaging but also contains phase information through its Fresnel diffraction integral.

36 MATERIALS SCIENCE↗

DeepSZ: identification of Sunyaev–Zel’dovich galaxy clusters using deep learning

Galaxy clusters identified via the Sunyaev–Zel’dovich (SZ) effect are a key ingredient in multiwavelength cluster cosmology. In this paper, we present and compare three methods of cluster identification: the standard matched filter (MF) method in SZ cluster finding, a convolutional neural networks (CNN), and a ‘combined’ identifier. We apply the methods to simulated millimeter maps for several observing frequencies for a survey similar to SPT-3G, the third-generation camera for the South Pole Telescope. The MF requires image pre-processing to remove point sources and a model for the noise, while the CNN requires very little pre-processing of images. Additionally, the CNN requires tuning of hyperparameters in the model and takes cut-out images of the sky as input, identifying the cut-out as cluster-containing or not. We compare differences in purity and completeness. The MF signal-to-noise ratio depends on both mass and redshift. Our CNN, trained for a given mass threshold, captures a different set of clusters than the MF, some with signal-to-noise-ratio below the MF detection threshold. However, the CNN tends to mis-classify cut-out whose clusters are located near the edge of the cut-out, which can be mitigated with staggered cut-out. We leverage the complementarity of the two methods, combining the scores from each method for identification. The purity and completeness are both 0.61 for MF, and 0.59 and 0.61 for CNN. The combined method yields 0.60 and 0.77, a significant increase for completeness with a modest decrease in purity. We advocate for combined methods that increase the confidence of many low signal-to-noise clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of UTE-MRI-based patient setup for brain cancer radiation therapy

Purpose: Radiation therapy simulations solely based on MRI have advantages compared to CT-based approaches. One feature readily available from computed tomography (CT) that would need to be reproduced with MR is the ability to compute digitally reconstructed radiographs (DRRs) for comparison against on-board radiographs commonly used for patient positioning. In this study, the authors generate MR-based bone images using a single ultrashort echo time (UTE) pulse sequence and quantify their 3D and 2D image registration accuracy to CT and radiographic images for treatments in the cranium. Methods: Seven brain cancer patients were scanned at 1.5 T using a radial UTE sequence. The sequence acquired two images at two different echo times. The two images were processed using an in-house software to generate the UTE bone images. The resultant bone images were rigidly registered to simulation CT data and the registration error was determined using manually annotated landmarks as references. DRRs were created based on UTE-MRI and registered to simulated on-board images (OBIs) and actual clinical 2D oblique images from ExacTrac™. Results: UTE-MRI resulted in well visualized cranial, facial, and vertebral bones that quantitatively matched the bones in the CT images with geometric measurement errors of less than 1 mm. The registration error between DRRs generated from 3D UTE-MRI and the simulated 2D OBIs or the clinical oblique x-ray images was also less than 1 mm for all patients. Conclusions: UTE-MRI-based DRRs appear to be promising for daily patient setup of brain cancer radiotherapy with kV on-board imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data from: "Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range"

This data package contains data that were used for analysis in “Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range”, by Moyes et al. 2013. All data collection and field research were completed on Niwot Ridge, Colorado, USA.This data package contains nine comma-separated-values (.csv) files, one text (.txt) file, and two zipped seedling folders that were used for leaf area analysis. One zipped folder contains 468 .jpg photographs of seedlings, and the second contains 468 corresponding Image J-processed .jpg images that include silhouette leaf area values. .csv and .txt files can be opened using any compatible simple text-editor software such as TextEdit (Mac) and Notepad (Windows); .csv’s can also be opened using R and Microsoft Excel. Image files can be opened using Preview (Mac) and Photos (Windows). In addition, there are a total of 31 Microsoft Excel files: three .xlsx files, and 28 raw Li-Cor output .xls files. This data user’s guide is available in .pdf format, and can be opened using Adobe Acrobat Reader, or any other compatible file viewing software. Geospatial data showing field site locations are also included in the archive for use and reference. There are two geospatial formats in this archive: ESRI shapefiles (.shp) and keyhole markup-language (.kml) files. Both file types contain bounding box information, with the former being polygons, and the latter containing corner coordinates for each site. ESRI shapefiles can be opened using any geospatial software compatible with the file type (such as ESRI’s ArcGIS suite and QGIS), and .kml files are compatible with Google Earth and Google Maps.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Continued changes in climate are projected to alter the geographic distributions of plant species, in part by affecting where individuals can establish from seed. We tested the hypothesis that warming promotes uphill redistribution of subalpine tree populations by reducing cold limitation at high elevation and enhancing drought stress at low elevation. We seeded limber pine (Pinus flexilis) into plots with combinations of infrared heating and water addition treatments, at sites positioned in lower subalpine forest, the treeline ecotone, and alpine tundra. In 2010, first-year seedlings were assessed for physiological performance and survival over the snow-free growing season. Seedlings emerged in midsummer, about 5–8 weeks after snowmelt. Low temperature was not observed to limit seedling photosynthesis or respiration between emergence and October, and thus experimental warming did not appear to reduce cold limitation at high elevation. Instead, gas exchange and water potential from all sites indicated a prevailing effect of summer moisture stress on photosynthesis and carbon balance. Infrared heaters raised soil growing degree days (base 5 °C, p < 0.001) and August–September mean soil temperature (p < 0.001). Despite marked differences in vegetation cover and meteorological conditions across sites, volumetric soil moisture content (θ) at 5–10 cm below 0.16 and 0.08 m^3 m^(−3) consistently corresponded with moderate and severe indications of drought stress in midday stem water potential, stomatal conductance, photosynthesis, and respiration. Seedling survival was greater in watered plots than in heated plots (p = 0.01), and negatively related to soil growing degree days and duration of exposure to θ < 0.08 m^3 m^(−3) in a stepwise linear regression model (p < 0.0001). We concluded that seasonal moisture stress and high soil surface temperature imposed a strong limitation to limber pine seedling establishment across a broad elevation gradient, including at treeline, and that these limitations are likely to be enhanced by further climate warming.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Maintenance log:Amended file name error in Data User's Guide May 19 2022

54 ENVIRONMENTAL SCIENCES↗

Area Values from Image Dimensions (AVID) v. 3

This code processes the images collected during high throughput tensile tests to measure the area of each specimen. First, the code identifies the reference images and primary sample images from list of images collected. Then, the size of the reference in the reference images is used to determine a scale (um/pixel) value which can be used to determine the size of each sample in an image. The subsequent sample images are processed to automatically detect the sample present and then identify the size in pixels. The measurements from two different views of the sample are then combined to determine the sample area (um2).

DeJong, StephanieA.↗

Air-to-air background oriented schlieren technique

An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.

Heineck, James Thomas↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Energy Survey Year 1 Results: Photometric Data Set for Cosmology

Here, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zeropoints, object catalogs, and ancillary data products -e.g., maps of survey depth and observing conditions, star-galaxy classification, and photometric redshift estimates|that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists of 137 million objects detected in coadded images covering 1800 deg 2 in the DES grizY filters. The 10 limiting magnitude for galaxies is g = 23.4, r = 23.2, i = 22.5, z = 21.8, and Y = 20.1. We also performed photometric calibration of Y1A1 GOLD by combining nightly zeropoint solutions with stellar-locus regression, and the absolute calibration accuracy is better than 2% over the survey area. DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic information extraction from neutron radiography imaging to estimate axial fuel expansion in $\mathrm{EBR-II}$

Approximately 130,000 metal fuel pins were irradiated in the Experimental Breeder Reactor II (EBR-II) during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed to characterize fuel behavior, like fuel swelling. However, due to the lack of technology or resources, many of the images have not been processed or were processed manually through visual examination. This paper represents first-attempt to develop an image processing algorithm capable of automatically extracting information regarding the degree of fuel swelling from neutron radiography imaging. The algorithm was applied to 120 images of three different metallic fuel pin compositions—U-10Zr, U-8Pu-10Zr, and U-19Pu-10Zr. The algorithm performs operations of image intensity adjustment, image binarization, region finding, and labeling to extract information about fuel swelling. The average growth for U-10Zr was found to be 8.49% with 95% Confidence Interval (CI) [8.33 –8.66%], for U-8Pu-10Zr — 7.50% with 95% CI [7.23 – 7.78%], and for U-19Pu-10Zr — 3.15%, with 95% CI [2.40 – 3.91%]. The results obtained by applying this automatic image processing algorithm are consistent with previously reported studies of the same types of fuels. The automatic image processing algorithm will be expanded to include thousands of available neutron radiography images and different types of fuels to investigate empirical dependencies of fuel swelling, which can be subsequently applied to advanced fuel modeling. Results from this study can later be compared to BISON simulations to further benchmark modeling efforts and develop assessment cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-P-48: The Quantitative Evaluation and Comparison of Image Distortion and Loss of X-Ray Images Between Anti-Scattered Grid and Moire Compensation Processing in Digital Radiography

Purpose: To quantitatively analyze the influence image processing for Moire elimination has in digital radiography by comparing the image acquired from optimized anti-scattered grid only and the image acquired from software processing paired with misaligned low-frequency grid. Methods: Special phantom, which does not create scattered radiation, was used to acquire non-grid reference images and they were acquired without any grids. A set of images was acquired with optimized grid, aligned to pixel of a detector and other set of images was acquired with misaligned low-frequency grid paired with Moire elimination processing algorithm. X-ray technique used was based on consideration to Bucky factor derived from non-grid reference images. For evaluation, we analyze by comparing pixel intensity of acquired images with grids to that of reference images. Results: When compared to image acquired with optimized grid, images acquired with Moire elimination processing algorithm showed 10 to 50% lower mean contrast value of ROI. Severe distortion of images was found with when the object’s thickness was measured at 7 or less pixels. In this case, contrast value measured from images acquired with Moire elimination processing algorithm was under 30% of that taken from reference image. Conclusion: This study shows the potential risk of Moire compensation images in diagnosis. Images acquired with misaligned low-frequency grid results in Moire noise and Moire compensation processing algorithm used to remove this Moire noise actually caused an image distortion. As a result, fractures and/or calcifications which are presented in few pixels only may not be diagnosed properly. In future work, we plan to evaluate the images acquired without grid but based on 100% image processing and the potential risks it possesses.

60 APPLIED LIFE SCIENCES↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Full-Depth Coadds of the WISE and First-Year NEOWISE-Reactivation Images

The Near Earth Object Wide-field Infrared Survey Explorer (NEOWISE) Reactivation mission released data from its first full year of observations in 2015. This data set includes ~2.5 million exposures in each of W1 and W2, effectively doubling the amount of WISE imaging available at 3.4 μm and 4.6 μm relative to the AllWISE release. In this paper, we have created the first ever full-sky set of coadds combining all publicly available W1 and W2 exposures from both the AllWISE and NEOWISE-Reactivation (NEOWISER) mission phases. We employ an adaptation of the unWISE image coaddition framework, which preserves the native WISE angular resolution and is optimized for forced photometry. By incorporating two additional scans of the entire sky, we not only improve the W1/W2 depths, but also largely eliminate time-dependent artifacts such as off-axis scattered moonlight. We anticipate that our new coadds will have a broad range of applications, including target selection for upcoming spectroscopic cosmology surveys, identification of distant/massive galaxy clusters, and discovery of high-redshift quasars. In particular, our full-depth AllWISE+NEOWISER coadds will be an important input for the Dark Energy Spectroscopic Instrument selection of luminous red galaxy and quasar targets. Our full-depth W1/W2 coadds are already in use within the DECam Legacy Survey (DECaLS) and Mayall z-band Legacy Survey (MzLS) reduction pipelines. Finally, much more work still remains in order to fully leverage NEOWISER imaging for astrophysical applications beyond the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

A DARK ENERGY CAMERA SEARCH FOR AN OPTICAL COUNTERPART TO THE FIRST ADVANCED LIGO GRAVITATIONAL WAVE EVENT GW150914

We report the results of a deep search for an optical counterpart to the gravitational wave (GW) event GW150914, the first trigger from the Advanced LIGO GW detectors. We used the Dark Energy Camera (DECam) to image a 102 deg{sup 2} area, corresponding to 38% of the initial trigger high-probability sky region and to 11% of the revised high-probability region. We observed in the i and z bands at 4–5, 7, and 24 days after the trigger. The median 5 σ point-source limiting magnitudes of our search images are i = 22.5 and z = 21.8 mag. We processed the images through a difference-imaging pipeline using templates from pre-existing Dark Energy Survey data and publicly available DECam data. Due to missing template observations and other losses, our effective search area subtends 40 deg{sup 2}, corresponding to a 12% total probability in the initial map and 3% in the final map. In this area, we search for objects that decline significantly between days 4–5 and day 7, and are undetectable by day 24, finding none to typical magnitude limits of i = 21.5, 21.1, 20.1 for object colors ( i − z ) = 1, 0, −1, respectively. Our search demonstrates the feasibility of a dedicated search program with DECam and bodes well for future research in this emerging field.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-R-20: Image Texture Features Correlate with Time to Local Failure in Lung SBRT Patients

Purpose: To explore possible correlation between CT image-based texture and histogram features and time-to-local-failure in early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT).Methods and Materials: From an IRB-approved lung SBRT registry for patients treated between 2009–2013 we selected 48 (20 male, 28 female) patients with local failure. Median patient age was 72.3±10.3 years. Mean time to local failure was 15 ± 7.1 months. Physician-contoured gross tumor volumes (GTV) on the planning CT images were processed and 3D gray-level co-occurrence matrix (GLCM) based texture and histogram features were calculated in Matlab. Data were exported to R and a multiple linear regression model was used to examine the relationship between texture features and time-to-local-failure. Results: Multiple linear regression revealed that entropy (p=0.0233, multiple R2=0.60) from GLCM-based texture analysis and the standard deviation (p=0.0194, multiple R2=0.60) from the histogram-based features were statistically significantly correlated with the time-to-local-failure. Conclusion: Image-based texture analysis can be used to predict certain aspects of treatment outcomes of NSCLC patients treated with SBRT. We found entropy and standard deviation calculated for the GTV on the CT images displayed a statistically significant correlation with and time-to-local-failure in lung SBRT patients.

60 APPLIED LIFE SCIENCES↗