Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Performance of Pulsed Thermal Tomography Imaging with Machine Learning-Based Classification of Defects in Additively Manufactured Structures

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermal Tomography Imaging (PTT) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTT capabilities in detecting and visualizing microscopic defects in metallic specimens. The thermal tomography (TT) algorithm obtains depth reconstructions of spatial effusivity from the data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring of images with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images. CNN is trained on a database of TT images created for a set of simulated metallic structures with elliptical subsurface voids. Test of CNN performance demonstrate the ability to classify radii and angular orientation of subsurface defects in TT images. In addition, we have shown that CNN trained on elliptical defects is capable of classifying irregular-shaped defects obtained from scanning electron microscopy (SEM) of stainless steel sections printed with LPBF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components. Third Annual Progress Report

Additive manufacturing (AM) of high-strength corrosion resistance alloys for nuclear energy applications, such as stainless steel and Inconel, is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Probability of crack initiation at the pore depends on size, shape, and orientation of the defect. Pulsed Infrared Thermography Imaging (PIT) provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PIT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PIT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PIT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PIT capabilities in detecting microscopic subsurface defects in metals, and classifying shapes and orientation of pores in thermal images. For detection of microscopic defects in PIT imaging data, we have developed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) image processing algorithm. We show that flat bottom hole (FBH) defects as small as 200µm in SS316 and IN718 specimens, can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature. For classification of defects shapes, we have previously developed thermal tomography (TT) algorithm to obtain depth reconstructions of material defects from data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vegetation Warming Experiment: Landscape-scale digital camera imagery for vegetation phenology, Utqiagvik (Barrow), Alaska, 2018

Images captured using a StarDot NetCam SC phenocamera looking east from the top of the Barrow Environmental Observatory (BEO) Sled Shed, Utqiagvik, Alaska. The camera was installed to remotely monitor plant phenology and operation of the BNL TEST group's ZPW (Zero Power Warming) chambers during the growing season of 2018. Images were captured from early spring (13 April) through to mid fall (18 October). Snowmelt, vegetation growth and senescence, and snow accumulation were captured. Images were uploaded to the BNL FTP server every hour until 16 June, and then every 10 minutes. Files were renamed with the date and time of the image. jpg images have been compressed in *.tar.gz format (7.9 GB). Different fields of view (northeasterly) were also captured using 3 Wingscapes TimelapseCam cameras mounted on a mast on the sled shed. Images were recorded from 21 June to 24 September, 2018, at 30 minute intervals, from 11:00 - 14:30, Alaska daylight time (AKDT, UTC-8). Movie files (.mp4) of each Wingscapes camera dataset. Additional metadata included in *.pdf and *.csv files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

KINEMATICS OF THE ORION TRAPEZIUM BASED ON DIFFRACTO-ASTROMETRY AND HISTORICAL DATA

Using the novel Diffracto-Astrometry technique, we analyze 44 Hubble Space Telescope Wide Field Planetary Camera 2 images of the Orion Trapezium (OT) taken over a span of 12 yr (1995-2007). We measure the relative positions of the six brighter OT components (A-F) and supplement these results with measurements of the relative separations and position angles taken from the literature, thus extending our analysis time base to ∼200 yr. For every pair of components we find the relative rate of separation as well as the temporal rate of change of their position angles, which enable us to determine the relative kinematics of the system. Component E shows a velocity larger than the OT's escape velocity, thus confirming that it is escaping from the gravitational pull of this system.

79 ASTRONOMY AND ASTROPHYSICS↗

Extending the depth of field through unbalanced optical path difference

We describe a simple method to extend the depth of field of a conventional camera by inserting a transparent annular ring in front of the pupil of the lens. The insertion of the ring creates an unbalanced optical path difference across the lens aperture, which partitions the pupil and leads to an extended depth of field. This system is analyzed by diffraction and random process theory. Experiments are reported that are in good agreement with the theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Z{sub eff} profile measurement system with an optimized Czerny-Turner visible spectrometer in large helical device

Z{sub eff} measurement system using a visible spectrometer has been newly designed and constructed instead of an old interference filter system to eliminate line emissions from the signal and to measure the Z{sub eff} value in low-density plasmas. The system consists of the Czerny-Turner-type spectrometer with a charge-coupled device camera and 44 optical fibers vertical array. The spectrometer is equipped with an additional toroidal mirror for further reduction in the astigmatism in addition to a flat and two spherical mirrors and three gratings (110, 120, and 1200 grooves/mm) with 30 cm focal length. The images from 44 optical fibers can be detected without astigmatism in a wavelength range of 200-900 nm. Combination of the optical fiber (core diameter: 100 {mu}m) with the lens (focal length: 30 mm) provides spatial resolution of 30 mm at the plasma center. Results clearly indicate a very good focus image of the fiber and suggest the absence of the cross-talk between adjacent fiber images. Absolute intensity calibration has been done using a standard tungsten lamp to analyze the Z{sub eff} value. The bremsstrahlung profile and resultant Z{sub eff} profile have been obtained after Abel inversion of the signals observed in large helical device plasmas with elliptical poloidal cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vegetation Warming Experiment: Chamber and ambient plot digital camera imagery for vegetation phenology, Utqiagvik (Barrow), Alaska, 2017

Time lapse photography (*.jpg) of experimental plots within five warming chambers (ZPWs) and paired control plots located on the Barrow Environmental Observatory (BEO), Barrow (now Utqiagvik), Alaska. Images were recorded from 21 June to 18 September, 2017 to capture vegetation dynamics during the growing season. Vegetation phenology, including green up and senescence were captured. Images were recorded daily at 30 minute intervals, from 11:00-14:30 Alaska daylight time (AKDT, UTC-8), using Wingscapes TimelapseCam cameras. The target species was Petasites frigidus. Also included multiple metadata files including reporting formats as *.pdf and *.csv files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Handheld multi-sensor biometric imaging device and processing pipeline

A handheld biometric imaging device having an array of cameras configured to simultaneously capture face, iris and fingerprint biometrics of a subject. The device includes a plurality of visible-light cameras and a plurality of infrared-light cameras capable of being triggered simultaneously to obtain a plurality of images from which a 3D image of the light field can be constructed. The device includes a plurality of visible-light illuminators and a plurality of infrared-light illuminators that allow images of a subject to be captured under different lighting profiles. The device may include an onboard control system that is capable of reconstructing a face region, an iris region and a fingerprint region from the 3D light-field image, and then extract a corresponding face template, an iris template, and a fingerprint template from the respective reconstructed regions. The extracted face, iris, and fingerprint templates may be used for enrollment and/or comparison against a biometric-template database associated with one or more watchlists.

Bolme, David S.↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

A two-dimensional deformable phantom for quantitatively verifying deformation algorithms

Purpose: The incorporation of deformable image registration into the treatment planning process is rapidly advancing. For this reason, the methods used to verify the underlying deformation algorithms must evolve equally fast. This manuscript proposes a two-dimensional deformable phantom, which can objectively verify the accuracy of deformation algorithms, as the next step for improving these techniques. Methods: The phantom represents a single plane of the anatomy for a head and neck patient. Inflation of a balloon catheter inside the phantom simulates tumor growth. CT and camera images of the phantom are acquired before and after its deformation. Nonradiopaque markers reside on the surface of the deformable anatomy and are visible through an acrylic plate, which enables an optical camera to measure their positions; thus, establishing the ground-truth deformation. This measured deformation is directly compared to the predictions of deformation algorithms, using several similarity metrics. The ratio of the number of points with more than a 3 mm deformation error over the number that are deformed by more than 3 mm is used for an error metric to evaluate algorithm accuracy. Results: An optical method of characterizing deformation has been successfully demonstrated. For the tests of this method, the balloon catheter deforms 32 out of the 54 surface markers by more than 3 mm. Different deformation errors result from the different similarity metrics. The most accurate deformation predictions had an error of 75%. Conclusions: The results presented here demonstrate the utility of the phantom for objectively verifying deformation algorithms and determining which is the most accurate. They also indicate that the phantom would benefit from more electron density heterogeneity. The reduction of the deformable anatomy to a two-dimensional system allows for the use of nonradiopaque markers, which do not influence deformation algorithms. This is the fundamental advantage of this verification technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

An Assessment of Homogeneous Mixture Method Cavitation Models in Predicting Cavitation in Nozzle Flow

The homogeneous mixture method (HMM) is a popular class of models used in the computational prediction of cavitation. Several cavitation models have been developed for use with HMM to govern the development and destruction of vapor in a fluid system. Two models credited to Kunz and Schnerr–Sauer are studied in this paper. The goal of this work is to provide an assessment of the two cavitation submodels in their ability to predict cavitation in nozzle flow. Validation data were obtained via experiments which employ both passive cavitation detection, (PCD) via acoustic sensing and optical cavitation detection (OCD) via camera imaging. The experiments provide quantitative information on cavitation inception and qualitative information on the vapor in the nozzle. The results show that initial vapor formation is not predicted precisely but within reason. A sensitivity analysis of the models to input parameters shows that the Schnerr–Sauer method does not depend upon the estimation of nuclei size and number density. Small changes in the vapor formation rate but not the total vapor volume can be seen when weighting parameters are modified. In contrast, changes to the input parameters for the Kunz model greatly change the final total vapor volume prediction. The assessment also highlights the influence of vapor convection within the method. Finally, the analysis shows that if the fluid and nozzle walls do not support nuclei larger than 40 μm, the methods would still predict cavitation when indeed there would be none in practice.

Engineering↗

PROPER MOTION OF THE LEO II DWARF GALAXY BASED ON HUBBLE SPACE TELESCOPE IMAGING

This article reports a measurement of the proper motion of Leo II, a dwarf galaxy that is a likely satellite of the Milky Way, based on imaging with the Hubble Space Telescope and Wide Field Camera 3. The measurement uses compact background galaxies as standards of rest in both channels of the camera for two distinct pointings of the telescope, as well as a QSO in one channel for each pointing, resulting in the weighted average of six measurements. The measured proper motion in the the equatorial coordinate system is (μ{sub α},μ{sub δ})=(−6.9±3.7,−8.7±3.9) mas century{sup −1} and in the Galactic coordinate system it is (μ{sub ℓ},μ{sub b})=(6.2±3.9,−9.2±3.7) mas century{sup −1}. The implied space velocity with respect to the Galactic center is (Π,Θ,Z) =(−37±38,117±43,40±16) km s{sup −1} or, expressed in Galactocentric radial and tangential components, (V{sub r},V{sub tan})=(21.9±1.5,127±42) km s{sup −1}. The space velocity implies that the instantaneous orbital inclination is 68°, with a 95% confidence interval of (66{sup ∘},80{sup ∘}). The measured motion supports the hypothesis that Leo II, Leo IV, Leo V, Crater 2, and the globular cluster Crater fell into the Milky Way as a group.

79 ASTRONOMY AND ASTROPHYSICS↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Proper motion of the Draco dwarf galaxy based on Hubble space telescope imaging

We have measured the proper motion of the Draco dwarf galaxy using images at two epochs with a time baseline of about two years taken with the Hubble Space Telescope Advanced Camera for Surveys. Wide Field Channels 1 and 2 provide two adjacent fields, each containing a known QSO. The zero point for the proper motion is determined using both background galaxies and the QSOs and the two methods produce consistent measurements within each field. Averaging the results from the two fields gives a proper motion in the equatorial coordinate system of (μ{sub α},μ{sub δ})=(17.7±6.3,−22.1±6.3) mas century{sup −1} and in the Galactic coordinate system of (μ{sub ℓ},μ{sub b})=(−23.1±6.3,−16.3±6.3) mas century{sup −1}. Removing the contributions of the motion of the Sun and of the LSR to the measured proper motion yields a Galactic rest-frame proper motion of (μ{sub α}{sup Grf},μ{sub δ}{sup Grf})=(51.4±6.3,−18.7±6.3) mas century{sup −1} and (μ{sub ℓ}{sup Grf},μ{sub b}{sup Grf})=(−21.8±6.3,−50.1±6.3) mas century{sup −1}. The implied space velocity with respect to the Galactic center is (Π,Θ,Z)=(27±14,89±25,−212±20) km s{sup −1}. This velocity implies that the orbital inclination is 70{sup ∘}, with a 95% confidence interval of (59{sup ∘},80{sup ∘}), and that the plane of the orbit is consistent with that of the vast polar structure (VPOS) of Galactic satellite galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF A PLANETARY-MASS COMPANION TO A BROWN DWARF IN TAURUS

We have performed a survey for substellar companions to young brown dwarfs in the Taurus star-forming region using the Wide Field Planetary Camera 2 on board the Hubble Space Telescope. In these data, we have discovered a candidate companion at a projected separation of 0.''105 from one of the brown dwarfs, corresponding to 15 AU at the distance of Taurus. To determine if this object is a companion, we have obtained images of the pair at a second epoch with the adaptive optics system at Gemini Observatory. The astrometry from the Hubble and Gemini data indicates that the two objects share similar proper motions and thus are likely companions. We estimate a mass of 5-10 M {sub Jup} for the secondary based on a comparison of its bolometric luminosity to the predictions of theoretical evolutionary models. This object demonstrates that planetary-mass companions to brown dwarfs can form on a timescale of {tau} {approx}< 1 Myr. Companion formation on such a rapid timescale is more likely to occur via gravitational instability in a disk or fragmentation of a cloud core than through core accretion. The Gemini images also reveal a possible substellar companion ({rho} = 0.''23) to a young low-mass star that is 12.''4 from the brown dwarf targeted by Hubble. If these four objects comprise a quadruple system, then its hierarchical configuration would suggest that the fragmentation of molecular cloud cores can produce companions below 10 M {sub Jup}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-201-05: On the Automatic Recognition of Patient Safety Hazards in a Radiotherapy Setup Using a Novel 3D Camera System and a Deep Learning Framework

Purpose: Patient safety hazards such as a wrong patient/site getting treated can lead to catastrophic results. The purpose of this project is to automatically detect potential patient safety hazards during the radiotherapy setup and alert the therapist before the treatment is initiated. Methods: We employed a set of co-located and co-registered 3D cameras placed inside the treatment room. Each camera provided a point-cloud of fraxels (fragment pixels with 3D depth information). Each of the cameras were calibrated using a custom-built calibration target to provide 3D information with less than 2 mm error in the 500 mm neighborhood around the isocenter. To identify potential patient safety hazards, the treatment room components and the patient’s body needed to be identified and tracked in real-time. For feature recognition purposes, we used a graph-cut based feature recognition with principal component analysis (PCA) based feature-to-object correlation to segment the objects in real-time. Changes in the object’s position were tracked using the CamShift algorithm. The 3D object information was then stored for each classified object (e.g. gantry, couch). A deep learning framework was then used to analyze all the classified objects in both 2D and 3D and was then used to fine-tune a convolutional network for object recognition. The number of network layers were optimized to identify the tracked objects with >95% accuracy. Results: Our systematic analyses showed that, the system was effectively able to recognize wrong patient setups and wrong patient accessories. The combined usage of 2D camera information (color + depth) enabled a topology-preserving approach to verify patient safety hazards in an automatic manner and even in scenarios where the depth information is partially available. Conclusion: By utilizing the 3D cameras inside the treatment room and a deep learning based image classification, potential patient safety hazards can be effectively avoided.

60 APPLIED LIFE SCIENCES↗

4D spatiotemporal evolution of liquid spray using kilohertz-rate x-ray computed tomography

Four-dimensional (x, y, z, t) x-ray computed tomography was shown in an optically complex spray using an imaging system consisting of three x-ray sources and three high-speed detectors. The x-ray sources consisted of high-flux rotating anode x-ray tube sources that illuminated the spray from three lines of sight. The absorption along each absorption path was collected using a CsI phosphor plate and imaged by a high-speed intensified CMOS camera at 20 kHz. The radiographs were converted to a quantitative equivalent path length (EPL) of liquid using a variable attenuation coefficient to account for beam hardening. Moreover, the EPL data were then reconstructed using the algebraic reconstruction technique into high-speed time sequences of the threedimensional liquid mass distribution.

47 OTHER INSTRUMENTATION↗