Search NASA⌕ Search

SEARCH · Search NASA

Results for “Irradiation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

KJRR-FAI Status Report of Conceptual Design Activities

The Korea Atomic Energy Research Institute has initiated the Ki-Jang Research Reactor (KJRR) project to construct a new dedicated radio-isotope production facility in the KiJang province of South Korea. The KJRR will employ a uranium-molybdenum dispersion plate-type fuel clad in aluminum. The KJRR fuel assembly design will undergo irradiation in the Advanced Test Reactor (ATR) as part of the regulatory qualification of the fuel. The Idaho National Laboratory performed a multi-disciplined conceptual design effort and found that one full-size KJRR fuel assembly can be irradiated in the ATR’s north east flux trap. The analyses accomplished during the conceptual design phase are sufficient to prove viability of the overall design and irradiation campaign. Requirements for fission power can be met. The desired burnup can be achieved well within 15% depending on reactor operating availability. Mechanical design and structural analysis show that structural integrity of the irradiation test is maintained. It is recommended that future detailed design efforts be based on the concept described in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

POST-TEST EXAMINATIONS OF A LOCA SAMPLE FROM AN IRRADIATED HIGH-BURNUP PWR M5 FUEL ROD

A LOCA integral test with high burnup PWR M5 fuel rod was conducted in the Irradiated Fuel Examination Laboratory through the complete LOCA sequence: heating the LOCA sample to 300ºC and pressurizing the internal pressure to 8.27 MPa, heating at 5ºC/s from 300 to 1200ºC, holding in steam for 90s at 1200ºC, cooling at 3ºC/s to 800ºC, followed by water quench and rapid cooling to 100ºC. After LOCA testing, examinations, such as the fuel fragmentation analysis, burst and ballooning characterization, axial strain measurement, and microstructural examinations were performed. Metallographic examinations of an as-irradiated high burnup sample adjacent to the LOCA test sample revealed a bonding layer between the fuel and cladding. The posttest LOCA examinations indicates the corrosion layer formed during normal operations in the commercial reactor might provide a protection against the steam oxidation at high temperatures for test times performed in this work. The microstructure of the as-irradiated fuel is compared to the microstructure of the post-LOCA test fuel. Posttest LOCA examination on unirradiated post-tests Zr cladding samples was conducted, which served as baseline data for in cell testing with irradiated samples. The results obtained with irradiated PWR high burnup M5 fuel rad were compared to the LOCA test data obtained with irradiated BWR high burnup Zircaloy-2 fuel rod at Argonne national Laboratory.

Yan, Yong↗

Updated NGNP Fuel Acquisition Strategy

A Next Generation Nuclear Plant (NGNP) fuel acquisition strategy was first established in 2007. In that report, a detailed technical assessment of potential fuel vendors for the first core of NGNP was conducted by an independent group of international experts based on input from the three major reactor vendor teams. Part of the assessment included an evaluation of the credibility of each option, along with a cost and schedule to implement each strategy compared with the schedule and throughput needs of the NGNP project. While credible options were identified based on the conditions in place at the time, many changes in the assumptions underlying the strategy and in externalities that have occurred in the interim requiring that the options be re-evaluated. This document presents an update to that strategy based on current capabilities for fuel fabrication as well as fuel performance and qualification testing worldwide. In light of the recent Pebble Bed Modular Reactor (PBMR) project closure, the Advanced Gas Reactor (AGR) fuel development and qualification program needs to support both pebble and prismatic options under the NGNP project. A number of assumptions were established that formed a context for the evaluation. Of these, the most important are: • Based on logistics associated with the on-going engineering design activities, vendor teams would start preliminary design in October 2012 and complete in May 2014. A decision on reactor type will be made following preliminary design, with the decision process assumed to be completed in January 2015. Thus, no fuel decision (pebble or prismatic) will be made in the near term. • Activities necessary for both pebble and prismatic fuel qualification will be conducted in parallel until a fuel form selection is made. As such, process development, fuel fabrication, irradiation, and testing for pebble and prismatic options should not negatively influence each other during the period prior to a decision on reactor type. • Additional funding will be made available beginning in fiscal year (FY) 2012 to support pebble bed fuel fabrication process development and fuel testing while maintaining the prismatic fuel schedule. Options for fuel fabrication for prismatic and pebble bed were evaluated based on the credibility of each option, along with a cost and schedule to implement each strategy. The sole prismatic option is Babcock and Wilcox (B&W) producing uranium oxycarbide (UCO) tristructural-isotropic (TRISO) fuel particles in compacts. This option finishes in the middle of 2022 . Options for the pebble bed are Nuclear Fuel Industries (NFI) in Japan producing uranium dioxide (UO2) TRISO fuel particles, and/or B&W producing UCO or UO2 TRISO fuel particles. All pebble options finish in mid to late 2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent upgrades and new scientific infrastructure of MARIA research reactor, Otwock-Swierk, Poland

The MARIA reactor is open-pool type, water and beryllium moderated. It has two independent primary cooling systems: fuel and pool cooling system. Each fuel assembly is cooled down separately in pressurized channels with individual performances characterization. The fuel assemblies consist of five layers of bent plates or six concentric tubes. Currently it is one of the most powerful research reactors in Europe with operation availability at least up to 2030. Its nominal thermal power is 30 MW. It is characterized by high neutron flux density: up to 3x10{sup 14} n cm{sup -2} s{sup -1} in case of thermal neutrons, and up to 2x10{sup 13} n cm{sup -2} s{sup -1} in case of fast neutrons. The reactor is operated for ca. 4000 h per year. The reactor facility is equipped with fully equipped three hot cells with shielding up to 10{sup 15} Bq. Adjacent to the reactor facility, the radio-pharmaceutics plant (POLATOM) and Material Research Laboratory are located. They are equipped with a number of hot cells with instrumentation. The transport system of radioactive materials from reactor facility to Material Research Laboratory is available. During 2014 the MARIA reactor has been operated with three different types of fuel the same time: previous 36% enriched fuel, and two types of new LEU fuels. In the meantime, molybdenum irradiation programme has been developed. Maria is a multifunctional research tool, with a notable application in production of radioisotopes, radio-pharmaceutics manufacturing (ca. 600 TBq/y), {sup 99}Mo for medical scintigraphy (ca. 6000 TBq/y), neutron transmutation doping of silicon single crystals, wide scientific research based on neutron beams utilization. From the beginning MARIA reactor was intended for loop and fuel testing research activities. Currently it is used mostly as material testing and irradiation facility and for that reason it has wide experimental capabilities. There are eight horizontal irradiation channels from among whom six of them are equipped with instrumentation for condensed matter physics research: - H3 - spectrometer and diffractometer with double monochromator; - H4 - small angle scattering spectrometer; - H5 - polarized neutrons spectrometer; - H6, H7 - two 3-axial crystal neutron spectrometers; - H8 - neutron radiography stand. For two horizontal channels are ongoing exploitation programs: - H2 - station with epithermal neutron beam produced in uranium converter is being developed. Intelligent converter will be installed on the periphery of reactor core. The intensity of the beam will be at the level 2x10{sup 9} n cm{sup -2}s{sup -1} what makes the beam unique in the Europe. - H1 - special pneumatic horizontal mail is being developed for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. The number of neutron irradiation facilities in MARIA reactor is increasing every year. Numerous of thermal neutron irradiation channels including fast hydraulic rabbit system and large size channels for fast neutron irradiation are used routinely. Recently new in-pile facility with ITER-like neutron energy spectrum for 14 MeV neutron irradiation has been constructed. Taking into account its performance and ability of almost incessant operation the facility appears as one of the most powerful 14 MeV neutron sources. The facility shall be used for material research connected with thermonuclear devices (ITER) and 4. generation nuclear reactors. The system of independent fuels channels used in MARIA reactor appear to be very flexible and very convenient to be used as irradiation channels for uranium targets for {sup 99}Mo production. Currently, MARIA reactor supplies ca. 18% world production of {sup 99}Mo. The MARIA reactor research activities are still extended. The current scientific projects are connected e.g. with silicon neutron transmutation doping, in-pile gamma heating measurements, French calculation codes implementation (TRIPOLI4, APOLLO2). The horizontal neutron beams utilization is also developed. The MARIA reactor, due to its primary application connected with loop and fuel testing, is very convenient for testing the nuclear instrumentation, control and measurement systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Status and Experimental Strategy for Initial Molten Salt Irradiation Experiments in HFIR

The development and deployment of molten salt reactor (MSR) technologies require experimental capabilities that can evaluate molten fuel salt behavior and structural material performance under representative irradiation conditions. Although modeling and separate effects testing provide important insight, there remains a critical lack of in-pile data that capture the coupled effects of neutron irradiation, temperature, salt chemistry, and time. Informed by lessons learned from historical MSR programs and recent international irradiation efforts, this report presents a structured approach to addressing existing gaps in molten salt irradiation testing using the High Flux Isotope Reactor (HFIR). A phased irradiation strategy is presented that incrementally increases experimental complexity while managing cost, risk, and facility constraints. The framework progresses from passive, nonfueled static capsule experiments to fueled, instrumented, and ultimately circulating molten salt systems, providing a pathway for materials screening, mechanistic understanding, and qualification-relevant testing. The report defines a near-term Phase 1 passive capsule concept, associated irradiation conditions, and a conceptual post-irradiation examination strategy. Ongoing modeling, out-of-pile testing, and safety analysis activities are described to support continued capability maturation and to enable future phases of molten salt irradiation testing in support of MSR technology deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructural evolution of Q12{sup TM} alloy irradiated in PWRs and comparison with other Zr base alloys - 2016-0061

Based on the M5{sup R}* alloy metallurgy, the Q12{sup TM} alloy (Zr-1Nb-0.5Sn-0.1Fe) was developed by AREVA NP for structural components, with ultra-low tin addition and slightly increased iron content. The behavior of this alloy was tested under irradiation in a pressurized water reactor (PWR) and has shown improvement in irradiation creep strength and similar free growth compared with M5. This paper provides results on dimensional stability and details the microstructural evolution of the Q12 alloy under neutron irradiation in PWRs. The Q12 microstructural evolution under irradiation was studied for fast neutron fluences up to 13 X 10{sup 25} n/m{sup 2} (E>1 MeV) with analytical transmission electron microscopy observations. We focused on radiation-enhanced needle-like particles, Laves phases, and the linear density of -component loops. These results are compared with other quaternary zirconium-niobium-tin-iron alloys and with M5. All these results allow a general discussion about microstructural evolution and behavior under irradiation of quaternary-type alloys compared to M5 alloy. This study, in agreement with previous works on Zr-1Nb and quaternary alloys, seems to show that increasing the iron content with the presence of niobium and tin will decrease the -component loop linear density and delay the growth breakaway. (authors)

36 MATERIALS SCIENCE↗

Analytical complex at the PIK reactor for studying the supra-atomic structure and dynamics of materials by neutron scattering

A project of the center for studying reactor materials and solving problems of materials science is presented which will be equipped with the following neutron instruments: a small-angle Membrana diffractometer, a spin-echo spectrometer, and a time-of-flight spectrometer. It is proposed to irradiate materials in the PIK reactor core and use neutron-scattering tools to analyze the structure and dynamics of these materials and investigate radiative defects in the complete experimental cycle (initial material-irradiation-strength tests, thermal loads, and other effects) using materials science techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

60 APPLIED LIFE SCIENCES↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status and Availability of OPTD, the Out-of-Pile Transient Database

The DOE Advanced Reactor Technology program has supported knowledge preservation efforts to recover and preserve fuel data from the US sodium cooled fast reactor (SFR) program. Databases have been established containing experimental data generated during the Integral Fast Reactor program (from in-pile experiments at EBR-II, FFTF, and TREAT) and during related outof-pile examinations of EBR-II-irradiated fuels. The information in these databases is essential to support further development and licensing activities for advanced fast reactor designs. OPTD, the Out-of-Pile Transient Database, is an organized, searchable archive of records describing out-ofpile furnace transient tests conducted on metallic fuels. It includes records of over 150 tests on irradiated fuel pins conducted in furnace apparatuses constructed in the Alpha-Gamma Hot Cell Facility at ANL. This report presents the content, functions, and accessibility of the Out-of-Pile Transient Database (OPTD). It describes the information presently available in the database, the web interface created to provide access to this information, the activities undertaken to build OPTD, and the enabling of online access to the database for DOE users. Plans for FY2021 and beyond are also included.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

METHOD FOR EXPOSING IRRADIATED FUEL CLADDING TO RAPID THERMAL TRANSIENTS

Reactor core materials exposed to rapid thermal transients during accidents can experience significant changes in mechanical properties as irradiation hardness is recovered. Understanding material performance during transients using computer modeling requires accurate descriptions of mechanical property evolution with time and temperature. A simple experimental capability was developed to expose irradiated Zircaloy to a simulated thermal transient using immersion in molten tin (at 675°C) to rapidly heat and hold before rapidly cooling with a water quench. Multiple heating-cooling cycles using a nonirradiated tensile specimen showed simplicity and viability. Based on preliminary test results, a robust system was established for routine evaluation of simulated thermal accident scenarios in the Low Activation Materials Design and Analysis (LAMDA) laboratory at Oak Ridge National Laboratory (ORNL). This paper summarizes system development and nonirradiated Zircaloy commissioning test results. Future experiments will conduct tensile tests on irradiated Zircaloy after various rapid temperature profiles.

Byun, TS↗

Evaluation of Candidate In-Pile Thermal Conductivity Techniques

Thermophysical properties of materials must be known for proper design, test, and application of new fuels and structural properties in nuclear reactors. In the case of nuclear fuels during irradiation, the physical structure and chemical composition change as a function of time and position within the rod. Typically, thermal conductivity changes, as well as other thermophysical properties being evaluated during irradiation in a materials and test reactor, are measured out-of-pile in “hot-cells.” Repeatedly removing samples from a test reactor to make out-of-pile measurements is expensive, has the potential to disturb phenomena of interest, and only provide understanding of the sample's end state at the time each measurement is made. There are also limited thermophysical property data for advanced fuels. Such data are needed for the development of next generation reactors and advanced fuels for existing nuclear plants. Having the capacity to effectively and quickly characterize fuels and material properties during irradiation has the potential to improve the fidelity of nuclear fuel data and reduce irradiation testing costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RBE of Energetic Iron Ions for the Induction of Early and Late Chromosome Aberrations in Different Cell Types

Numerous published studies have reported the Relative Biological Effectiveness (RBE) values for chromosome aberrations induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo has been suggested to show a similar relationship as the quality factor for cancer induction. Therefore, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. However, the RBE value is known to be very different for different types of cancer. Previously, we reported that, even though the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions, the RBE was significantly reduced after multiple cell divisions post irradiation. To test the hypothesis that RBE values for chromosome aberrations are cell type dependent, and different between early and late damages, we exposed human lymphocytes ex vivo, and human mammary epithelial cells in vitro to various charged particles. Chromosome aberrations were quantified using the samples collected at first mitosis post irradiation for initial damages, and the samples collected after multiple generations for the remaining or late arising aberrations. Results of the study suggested that the effectiveness of high-LET charged particles for late chromosome aberrations may be cell type dependent, even though the RBE values are similar for early damages.

Zhang, Ye↗

Online 3D EPID-based dose verification: Proof of concept

Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took 266 ± 11 ms on a dual octocore Intel Xeon E5-2630 CPU running at 2.40 GHz. The introduced delivery errors were detected after 5–10 s irradiation time. Conclusions: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for two different kinds of gross delivery errors. Thus, online 3D dose verification has been technologically achieved.

60 APPLIED LIFE SCIENCES↗

Bench-level characterization of a CMOS standard-cell D-latch using alpha-particle sensitive test circuits

A methodology is described for predicting the SEU susceptibility of a standard-cell D-latch using an alpha-particle sensitive SRAM, SPICE critical charge simulation results, and alpha-particle interaction physics. Measurements were made on a 1.6-micron n-well CMOS 4-kb test SRAM irradiated with an Am-241 alpha-particle source. A collection depth of 6.09 micron was determined using these results and TRIM computer code. Using this collection depth and SPICE derived critical charge results on the latch design, an LET threshold of 34 MeV sq cm/mg was predicted. Heavy ion tests were then performed on the latch and an LET threshold of 41 MeV sq cm/mg was determined.

Blaes, B. R.↗

Anisotropic swelling and microcracking of neutron irradiated Ti 3 AlC 2 -Ti 5 Al 2 C 3 materials

M n + 1 AX n (MAX) phase materials based on Ti–Al–C have been irradiated at 400 °C (673 K) with fission neutrons to a fluence of 2 × 10 25 n/m 2 (E > 0.1 MeV), corresponding to ~ 2 displacements per atom (dpa). We report preliminary results of microcracking in the Al-containing MAX phase, which contained the phases Ti 3 AlC 2 and Ti 5 Al 2 C 3 . Equibiaxial ring-on-ring tests of irradiated coupons showed that samples retained 10% of pre-irradiated strength. Volumetric swelling of up to 4% was observed. Phase analysis and microscopy suggest that anisotropic lattice parameter swelling caused microcracking. Lastly, variants of titanium aluminum carbide may be unsuitable materials for irradiation at light water reactor-relevant temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗