Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Selection of Target Thickness and Size of Drive Electron Beam for Ce+BAF Injector

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130-370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The positron yield and longitudinal polarization are calculated for the 123 MeV Ce+BAF injector at the Low Energy Recirculator Facility (LERF). The longitudinal and transverse CEBAF acceptances, defined as an energy spread of less than 1% and a normalized emittance of less than 100 mm·mrad, have been used in these calculations. The impact of target thickness, transverse electron beam size, and electron beam energy on the yield and polarization of a positron injector is evaluated. The total energy deposited by the beams in the tungsten target and the peak energy density are calculated for different target thicknesses, electron beam sizes, and energies.

Ushakov, Andriy [Thomas Jefferson National Acceler↗

Positron Injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the CEBAF at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam 1 mA, 130-370 MeV, and 90% longitudinal polarization that passes through a rotating, water-cooled, tungsten target. The simulations for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are performed, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, 1.2 mm bunch length and normalized emittance of 100 mm·mrad). The impact of target thickness, electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated. Target thermal and structural FEM analyses (ANSYS Fluent) are performed to determine the maximum electron beam current and minimum transverse beam size on the target.

Benesch, Jay [Thomas Jefferson National Accelerato↗

Flavor Dependence of Charged Pion Fragmentation Functions

We have measured the flavor dependence of multiplicities for π + and π - production in semi-inclusive deep-inelastic scattering (SIDIS) on proton and deuteron to explore a possible charge symmetry violation in fragmentation functions. The experiment used an electron beam with energies of 10.2 and 10.6 GeV at Jefferson Lab and the Hall-C spectrometers. The electron kinematics spanned the range 0.3 < x < 0.6, 2 < Q 2 < 5.5 GeV2, and 2.2 < W < 3.2 GeV. The pion fractional momentum range was 0.3 < z < 0.7, and the transverse momentum range was 0 < p T < 0.25 GeV/c. Assuming factorization and allowing for isospin breaking, the results can be described by two “favored” and two “unfavored” effective low p T fragmentation functions that are flavor-dependent. We find each pair converges to a common flavor-independent fragmentation function at the highest W, where factorization is most applicable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗

Suppression of neutral-pion production in deep-inelastic scattering off nuclei with the CLAS detector

We present the first threefold differential measurement for neutral-pion multiplicity ratios produced in semi-inclusive deep-inelastic electron scattering on carbon, iron, and lead nuclei normalized to deuterium from CLAS at Jefferson Lab. We found that the neutral-pion multiplicity ratio is maximally suppressed for the leading hadrons (energy fraction 𝑧 → 1), suppression varying from 25% in carbon up to 75% in lead. An enhancement of the multiplicity ratio at low 𝑧 and high 𝑝$^2_𝑇$ is observed, suggesting an interconnection between these two variables. This behavior is qualitatively similar to the previous twofold differential measurement of charged pions by the HERMES Collaboration and, recently, by CLAS Collaboration. The largest enhancement was observed at high 𝑝$^2_𝑇$ for heavier nuclei, namely, iron and lead, while the smallest enhancement was observed for the lightest nucleus, carbon. This behavior suggests a competition between partonic multiple scattering, which causes enhancement, and hadronic inelastic scattering, which causes suppression.

color confinement↗

Conceptual design of highly-constrained splitters for the FFA@CEBAF energy upgrade study

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is investigating a significant energy upgrade utilizing Fixed-Field Alternating-gradient (FFA) recirculating arcs. This upgrade requires the design of complex horizontal beam splitters to manage up to six concurrent beam passes. This paper presents the conceptual design of these splitters, which are subject to severe physical constraints imposed by the existing accelerator tunnel and multifaceted beam dynamics requirements for matching into the permanent-magnet FFA arcs. The design methodology, centered on multi-pass simulations in the Bmad toolkit, is detailed from the initial geometric layout through the advanced optics matching. Key results include a robust geometric arrangement that fits within the spatial boundaries and the development of multiple, flexible optics matching solutions. Furthermore, the design integrates a viable scheme for extracting high-energy beams for the experimental halls, a critical operational requirement. This work establishes a comprehensive and viable conceptual design, forming a baseline for future engineering and performance optimization studies.

Bodenstein, R.M. [Thomas Jefferson National Accele↗

FFA BEAM TRANSPORT DEMONSTRATION DEVELOPMENT FOR THE CEBAF 22 GeV UPGRADE

Jefferson Lab is planning an upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) to deliver highly polarized electron beams up to 22 GeV using Fixed- Field Alternating-gradient (FFA) magnets. As the application of FFA technology in the 10–22 GeV energy range is unprecedented, experimental validation is required prior to full-scale implementation. To support this effort, a dedicated FFA test insert is proposed within the existing CEBAF infrastructure, with candidate locations in the Beam Switchyard (BSY) dump line or the Hall C beamline. The testbed will consist of a half or full FFA cell using combined-function permanent magnets and will enable systematic studies of beam transport, field quality, alignment, and magnet performance under realistic conditions. Operation with polarized beams in the 5–11 GeV range will closely replicate the energy scaling of the full upgrade. This paper presents the current design status and layout options for the proposed FFA beam transport test line.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Lifetime extension of legacy CEBAF LLRF hardware

A significant portion of the Low-Level Radio Frequency (LLRF) hardware in Jefferson Lab’s CEBAF is from the original construction of the facility using 1980’s CAMAC technology. Of the fifty-three zones in CEBAF, thirty-six of them are legacy hardware. The age of the legacy system has led to difficulties in maintaining the hardware due to parts going obsolete without suitable drop in replacements. Continued operation of the legacy system is required as the installation of LLRF 3.0 systems is costly and cannot be completed in a short period of time with the available resources. The most pressing failure in the legacy system was a failing buffer card, which is responsible for communication between the EPICs network and individual RF control modules. A new buffer card was designed as a transparent, drop in, replacement so that upgrades are simply a matter of swapping the existing legacy hardware. This buffer card upgrades a single point failure component and promises to extend the operable lifetime of CEBAF’s legacy systems.

Accelerator Physics↗

The JLAMP UV/Soft X-ray User facility

Jefferson Lab (JLab) is proposing JLAMP (JLab AMPlifier), a 4th generation light source covering the range 10?100 eV in the fundamental mode with harmonics stretching towards the oxygen k-edge. The scientific purpose is to study ultrafast dynamics in complex systems as a pathway to the understanding and creation of novel materials and devices, with a twin focus on changing our approach to the use of energy and on improving our stewardship of the environment. Expert groups of physicists and chemists have identified the game-changing science offered by such a light source. The machine will be based on an energy upgrade to an existing energy-recovering linear accelerator at JLab, made possible by advances in superconducting accelerator technology. Specifically, accelerating gradients of 20 MV/m and electron-beam recirculation will allow electron-beam energies of >600 MeV to be achieved at repetition rates up to 4.68 MHz with continuous wave RF. The average brightness will substantially exceed existing light sources in this device's wavelength range of 100 nm down to 10 nm, extended by harmonics towards 2 nm. Multiple photon sources will be made available for pump-probe dynamical studies. The system will be capable of operating as a seeded amplifier for precise pulse length and bandwidth control or as an oscillator at higher average brightness. The plans for construction of this User facility will be presented. We will also present an overview of the science case supporting the submission. Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE?AC05?06OR23177. The U.S.Government retains a non?exclusive, paid?up, irrevocable, world?wide license to publish or reproduce this manuscript for U.S. Government purposes.

Neil, George↗

Multidimensional measurements of beam single-spin asymmetries in semi-inclusive deep-inelastic charged-kaon electroproduction off protons in the valence region

Measurements of beam single-spin asymmetries in semi-inclusive deep-inelastic electron scattering (SIDIS) with positively charged kaons off protons have been performed with 10.6 and 10.2 GeV incident electron beams using the CLAS12 spectrometer at Jefferson Lab. We report an analysis of the electroproduction of positively charged kaons over a large kinematic range of fractional energy, Bjorken 𝑥, transverse momentum, and photon virtualities 𝑄 2 ranging from 1 GeV 2 up to 6 GeV 2 . This is the first published multidimensionally binned CLAS12 measurement of a kaon SIDIS single-spin asymmetry in the valence quark regime. The data provide constraints on the structure function ratio $𝐹^{sin \space𝜙}_{𝐿⁢𝑈}$⁡/$𝐹_{𝑈⁢𝑈}$, where $𝐹^{sin \space𝜙}_{𝐿⁢𝑈}$ is a quantity with a leading twist of twist-3 that can reveal novel aspects of the quark-gluon correlations within the nucleon. The impact of the data on understanding the underlying reaction mechanisms and their kinematic variation is explored using theoretical models for the different contributing twist-3 parton-distribution functions (PDFs) and fragmentation functions (FFs).

form factors↗

An extraction scheme for future CEBAF FFA based energy upgrade

Jefferson lab is considering an energy increase from current 12 GeV to 22 GeV for its CEBAF accelerator. This will be accomplished by recirculating 5-6 additional turns through two parallel CEBAF LINACs using an FFA arc at each end of the racetrack. The total recirculation turns would be 10 times, the first four turns use present conventional arcs to make the 180-degree bends from one LINAC to the other. However, the last 5-6 turns will all share a single beam line inside two FFA arcs. This reduces the footprint and the cost of the project significantly. On the other hand, having the trajectories of last 5-6 recirculating beams close to each other makes it challenging to extract beams from different passes with different energies. In this paper we will explain our present extraction system for 12 GeV, our challenges and limitations, and a possible extraction solution for the 22 GeV upgrade with the goal of extracting beam at different turns/energies to different experimental halls.

Accelerator Physics↗

Hydra: An AI-Based Framework for Interpretable and Portable Data Quality Monitoring

Hydra is an advanced framework designed for training and managing AI models for near real time data quality monitoring at Jefferson Lab. Deployed in all four experimental halls, Hydra has analyzed over 2 million images and has extended its capabilities to offline monitoring and validation. Hydra utilizes computer vision to continually analyze sets of images of monitoring plots generated 24/7 during experiments. Generally, these sets of images are produced at a rate and quantity that is exceedingly difficult for shift crews to effectively monitor. Significant effort has been devoted to enhancing Hydra’s user interface, to ensure that it provides clear, actionable insights for shift workers and other users. Gradient Weighted Class Activation Maps (GradCAM) provide added interpretability, allowing users to visualize important regions of the image for classification. Hydra has been containerized to enable the creation of portable demos and seamless integration with container-based technologies such as Kubernetes and Docker. With the user interface enhancements and containerization, Hydra can be rapidly deployed for new use cases and experiments. This talk will describe the Hydra framework, its user interface and experience, and the challenges inherent in its design and deployment.

Britton, Thomas [Thomas Jefferson National Acceler↗

First Measurement of Near-Threshold and Subthreshold 𝐽/𝜓 Photoproduction off Nuclei

We report on the first measurement of J/ψ photoproduction from nuclei in the photon energy range of 7 to 10.8 GeV, extending above and below the photoproduction threshold in the free proton of ∼ 8.2 GeV. The experiment used a tagged photon beam incident on deuterium, helium, and carbon, and the GlueX detector at Jefferson Lab to measure the semi-inclusive A(γ, e + e − p) reaction with a dilepton invariant mass M(e + e − ) ∼ m J/ψ = 3.1 GeV. The incoherent J/ψ photoproduction cross sections in the measured nuclei are extracted as a function of the incident photon energy, momentum transfer, and proton reconstructed missing light-cone momentum fraction. Comparisons with theoretical predictions assuming a dipole form factor allow extracting a gluonic radius for bound protons of p $\sqrt4⟨r^2⟩$ = 0.85 ± 0.14 fm. The data also suggest an excess of the measured cross section for sub-threshold production and for interactions with high missing light-cone momentum fraction protons. The measured enhancement can be explained by modified gluon structure for high-virtuality bound-protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SoLID Program at JLab

An overview of the Solenoidal Large Intensity Device (SoLID) and its scientific program will be given in this talk. SoLID is a spectrometer/detector system proposed to exploit the full potential of the Jefferson Lab (JLab) 12 GeV energy upgrade. SoLID will push the limit of luminosity frontier in hadronic physics with its unique capability to handle very high rates with large acceptance under high luminosity (1037-39/cm2/s). A rich and vibrant scientific program has been developed for SoLID, including but not limited to the precision study of the 3d nucleon structure in both momentum space using Semi-Inclusive Deep Inelastic Scattering (SIDIS) and coordinate space using Deep Virtual Exclusive Reactions (DVER), probing physics beyond the Standard Model with Parity Violating Deep Inelastic Scattering (PVDIS), and investigating the gluonic field contribution to the proton structure and proton mass via J/¿ threshold production. The SoLID collaboration has developed a robust, low risk and flexible conceptual design, with a base line design capable of accomplishing its scientific goals and flexibility to adopt the cutting-edge technology. Detector subsystems have been tested with prototypes in realistic high luminosity conditions and are demonstrated to function well under extremely challenging environment to satisfy the requirements of planned experiments.

Chen, Jian-Ping [Thomas Jefferson National Acceler↗

Novel experimental probes of QCD in SIDIS and e + e - annihilation (Final Technical Report)

The research addressed with this award seeks to advance our understanding of the structure and dynamics underlying the properties of visible matter. In our current understanding the nucleons (protons and neutrons) are not fundamental but are comprised of quarks and gluons, which are collectively called partons. A static quark picture fails to explain the properties of the nucleons, such as their mass and intrinsic spin, which are thought to emerge dynamically from the quark-gluon interactions via the strong force. In this work, novel observables employing correlations of particles produced in the scattering of high energy electrons off protons at the CLAS12 experiment at Jefferson Lab were analyzed to probe quark-gluon interactions. The ultimate goal of this line of inquiry is to be able to describe the properties of protons and neutrons from first principles, similar to how studying the hydrogen atom has led to the formulation of the theory of Quantum Electrodynamics. Because quarks cannot be observed directly but only as part of more complex composite particles, a smaller, complimentary part of this work was the analysis of particle production in electron-positron annihilation at the Belle II experiment to understand the production of particles from initial quarks. This takes advantage of the fact that in e + e - annihilation the initial quark dynamics is known, unlike in the scattering of nucleons. Several new applications using Machine Learning algorithms for event tagging and reconstruction to support this program were developed as part of this award. In addition, we had a significant role in the development of the physics program for the future Electron-Ion Collider, which is a new collider to be build in the US within the next decade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

Baryon–antibaryon photoproduction cross sections off the proton

The GlueX experiment at Jefferson Lab has observed 𝑝⁢$\overline{p}$ and, for the first time, Λ$\overlineΛ$ and 𝑝$\overlineΛ$ photoproduction from a proton target at photon energies up to 11.6 GeV. The angular distributions are forward peaked for all produced pairs, consistent with Regge-like 𝑡-channel exchange. Asymmetric wide-angle antibaryon distributions show the presence of additional processes. In a phenomenological model, we find consistency with a double-𝑡-channel exchange process where antibaryons are created only at the middle vertex. The model matches all observed distributions with a small number of free parameters. In the hyperon channels, we observe a clear distinction between photoproduction of the Λ$\overlineΛ$ and 𝑝$\overlineΛ$ systems but general similarity to the 𝑝$\overline{p}$ system. We report both total cross sections and cross sections differential with respect to momentum transfer and the invariant masses of the created particle pairs. No narrow resonant structures were found in these reaction channels. The suppression of 𝑠$\overline{s}$ quark pairs relative to 𝑑$\overline{d}$ quark pairs is similar to what has been seen in other reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗