Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of Extended Reality Technologies for Use in Verification Testing at NASA 2024 HRP IWS Abstract

BACKGROUND At NASA, verification testing is the formal process of ensuring that a product conforms to requirements set by a project or program. Some verification methods, such as Demonstrations and Test, require either the end product or a mockup of the product with sufficient fidelity to stand-in for the product during the test. Traditionally, these mockups have been physical (e.g., foam-core and wood) but there is growing interest in exploring new methods for testing with these mockups. These methods include virtual reality (VR), mixed reality, and augmented reality which are collectively referred to as eXtended Reality (XR) technologies. VR has already been adopted and used by many in the aerospace industry as a tool for use in early design phases (e.g., developmental testing) and may have the most potential for use in verification tests. Benefits of using VR mockups offer cost effectiveness, ease of iteration, simulation of hazardous conditions (e.g., an egress through a hatch with smoke obscuring vision), and the ability to simulate microgravity conditions, which are challenging to do with physical mockups. However, the validity of test results obtained from VR mockup demonstrations or testing, compared to the current gold standard of physical mockups, remains uncertain. It is unlikely that there is one clean answer as there are many different types of verification outcomes and each XR technology must be evaluated on its own merits. This is not an issue during developmental testing as the design is still in flux and the total success of the design is not dependent upon the results of a developmental test. Verification tests, however, only happen once, assuming no change to the design, and the results are used to certify the product. Therefore, establishing the validity of XR mockup-based verification outcomes is essential before considering them for any use in verification tests. OBJECTIVE AND METHOD To address this concern, the Human Research Program has funded a project to explore and qualify how XR technologies might be used in verification demonstration and testing at NASA. Currently, we are conducting a review of the literature on the utilization of XR mockups for design activities, prototyping, and user testing. We are employing the Strengths, Weaknesses, Opportunities, and Threats (SWOT) analysis method to identify the pros, cons, and barriers to adoption of XR technologies for verification testing at NASA. Additionally, we are developing a framework to guide the deployment of XR mockups for verification tests. Building upon available evidence from the literature and subject-matter expert feedback, our goal for the framework is to provide guidelines for which forms of XR mockups are suitable for a given verification test, when only physical mockups should be employed and to highlight areas for which more evidence is needed. To further refine our framework and to contribute to the body of evidence, we are planning a lab-based experiment comparing a VR mockup to a physical twin for a set of select verification outcomes. ANTICIPATED RESULTS In this presentation, we will present the work we conducted to evaluate XR technologies for use in verification tests at NASA. We will summarize and report our findings from the SWOT analysis and our lab-based study, and we will present the current state of the XR Technologies for Verification Testing framework. We will conclude by summarizing remaining work and future directions for the project. Technologies for Verification Testing framework. We will conclude by summarizing remaining work and future directions for the project.

Extended Reality↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Cost (CAPEX and variable): Tool design for cell and module fabrication with thin, free-standing silicon wafers

This project aimed to develop technologies that can potentially enable free-standing thin (<80 μm) wafer in today’s manufacturing lines with high production yield, and thereby reduce capex barriers of silicon photovoltaics cells and modules. One of the major benefits is that thin wafer dramatically reduces the amount of polysilicon required. As a result, it can lead to reduction in the capital expenditures associated with polysilicon refining and wafer fabrication, which together are more than half of the total capital expenditure to manufacture Si PV module. We focused our efforts on developing the tools needed to enable high yield fabrication of wafer, cell, and module with thin silicon wafers. However, as the wafer thickness reduces, the major challenge is that wafer breakage increases significantly. Three technological areas were explored in this project to improve the production yield of the silicon wafer, namely detection of edge cracks via dark-field near-infrared (NIR) scattering; (2) wafer handling using controlled temperature profiles; (3) manufacturable low-stress cell interconnection for multiwire. First, the formation of wafer cracks in submillimeter length is one of the reasons that causes wafer breakages. Crack detection tools are needed to enable us to locate and track the wafer crack during manufacturing, so that we can improve the process to reduce initialization. The state-of-the-art crack detection technique cannot fulfill the need for measuring submillimeter edge cracks detrimental for thin wafers. The prototype developed in this project demonstrates the scanning of microcracks near wafer edges. With a semi-automatic laboratory setup, the submillimeter cracks were reliably detected near the edges in multi-Si wafers. The smallest detectable crack is 200 µm in length in slow scans; and submillimeter cracks are detected in high-throughput scans at the scan speed of >0.5 m/s, which is compatible with the inline detection of a manufacturing line at least 1 sec/wafer. This detection limit is a significant advancement in comparison to the benchmarked industrial tool. Second, wafer handling with the well-controlled temperature profile was thought to be the solution to reduce crack initiation and propagation during the manufacturing. However, without crack detection being widely adopted in production line, we did not find a strong industrial pull toward this technology. We did an initial literature survey and then diverted our efforts to the other tasks. Third, the innovation on low-stress multi-wire interconnection tackles a fundamental problem in the standard interconnection scheme. The standard over-under “zig-zag” interconnection induces a significant amount of stress into the soldering point on the cell whenever PV module is under stress, e.g., thermal cycling, transportation, and installation. Therefore, the interconnection process was re-designed in this project to allow for significant movement between adjacent solar cells, e.g., due to thermal expansion, without building up stresses on the solar cells or solder joints. The new interconnection method with the cross-connect wire also simplifies the tabbing and stringing process by replacing the standard over-under method with an off-cell interconnect from top to bottom. A manual tabbing and stringing tool for this new process was prototyped in the lab to demonstrate the fabrication of this new interconnection design. During the test with brass sheets as our “testing cells”, it was found that the mechanical cycling test only broke the interconnection after more than 50,000 cycles, which is equivalent to more than 130 years of the day-and-night thermal cycles. Lastly, throughout the project, we continuously analyzed the PV market with techno-economic analysis to identify the opportunity for thin Si adoption. Even though the drastic cost reduction has already happened in the past five years, our analysis results indicated that we can still save quite significantly in both manufacturing cost and factory capex, Particularly, in order to grow the PV manufacturing capacity to multi-terawatt level, reducing the thickness of silicon wafer is one of the most effective ways to quickly reduce factory capex, and sustain the high growth rate. The technologies developed in this project are readily available to provide some assistances in tackling the production yield problem.

14 SOLAR ENERGY↗

Structural Health Monitoring: Using an Autoencoder to Identify Damage in a Bolted Joint [Capstone Project]

Los Alamos National Laboratory (LANL) is an important fixture in the United States Department of Energy’s (DOE) National Nuclear Security Agency (NNSA) complex. LANL is one of the largest national laboratories in the country, and the laboratory’s primary mission is to support the nation’s nuclear stockpile. The lab functions as a design agencies for the NNSA and performs extensive testing on weapons as part of that mission. The shock and vibration test team at LANL utilizes electrodynamic shaker systems for important qualification testing in support of the laboratory’s mission. Modern engineering relies heavily on bolted joints to connect two objects. During these shaker tests, engineers depend on bolted joints to secure the test article to a fixture and the fixture to the table. The test article may be hazardous and contain high explosives which could create a safety issue if a bolted joint failed. A loss of preload in a bolt will affect the way energy is input to the system and may introduce nonlinearities as the joint opens and closes. The loss of preload can create challenges controlling the test and make acquired signals useless. Being able to monitor preload within bolted joints during testing can improve the quality of the data and keep workers safe.

42 ENGINEERING↗

Membrane Development for CO2 Capture from Steel Manufacturing

The U.S. government is targeting a net-zero carbon-emission economy by 2050, offering an exciting opportunity for membrane-based CO2 capture from various industrial point sources. Given that industrial flue gas has low CO2 partial pressures and high volumetric flow rates, high-permeance membranes are needed to make membrane technology economically viable for large-scale deployment. Thin film composite (TFC) membranes are necessary for this implementation because they can provide high permeance by forming a thin selective layer on top of a porous support. This presentation will report the rational design and fabrication of NETL’s highly permeable non-aging TFCs achieved by: synthesizing a high-performance rubbery selective material; developing a high-porosity membrane support; optimizing coating methods to assemble the two materials into scalable membranes; and scaling up membrane supports and TFCs via a roll-to-roll process. The novel rubbery selective material shows mixed-gas CO2 permeability of 930 Barrer and CO2/N2 selectivity of 44, exceeding the 2008 Robeson upper bound. The resulting TFCs yield remarkably high CO2 permeance of 4,500 GPU and CO2/N2 selectivity of 34 at 23ºC. Moreover, the TFCs exhibit not only excellent performance stability (or non-aging behavior) for 1,000 hours in the lab, but also maintain their separation properties in a 700-hour field test at the U.S. DOE’s National Carbon Capture Center using real humid flue gas.

Tran, Thien↗

Generation of uniform chromaticity scale imagery from LANDSAT data

An algorithm is presented for generating uniform chromaticity scale (UCS) imagery from multispectral data. A computer program was written to implement the algorithm, and UCS film products were generated. The colors in the film and their temporal change are consistent with those expected for the particular scaling of Krauth components into the (lab) color space. The film product was not subjected to the practical test of competing with previous transformations. Preliminary examination indicates that the product offers the following possibilities: (1) a single film product that will supplant two film products in current use; (2) improved visibility of data differences in regions in data space that are critical to crop identification; and (3) an analytic route to the determination of data-space transformations that will be optimal for particular discrimination problems.

Juday, R. D.↗

The NASA strain gage laboratory

The goal of the NASA-sponsored high-temperature high-strain gage program (which combines in-house, contract, and grant work) is to develop a gage that will measure static strains up to 2000 microstrain to within 10 percent, and at temperatures up to 1250 K (typical for combustors and turbine blades and vanes of gas turbine engines) maintained over 50-h period. The basic equipment of the NASA in-house lab is described (with special attention given to the strain-gage testing system), and some examples of recent test results are discussed. Data are presented on following tests performed on four gages: apparent strain vs temperature at different cooling rates, gage factor at various strain and temperature levels, and drift and creep tests at 133 C.

Hobart, Howard F.↗

Integration for navigation on the UMASS mobile perception lab

Integration of real-time visual procedures for use on the Mobile Perception Lab (MPL) was presented. The MPL is an autonomous vehicle designed for testing visually guided behavior. Two critical areas of focus in the system design were data storage/exchange and process control. The Intermediate Symbolic Representation (ISR3) supported data storage and exchange, and the MPL script monitor provided process control. Resource allocation, inter-process communication, and real-time control are difficult problems which must be solved in order to construct strong autonomous systems.

Draper, Bruce↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Nondestructive Crack Detection in a Fuel System Component

The presentation examines the background and objective of nondestructive crack detection, flow control valve assembly and poppet post flight evaluation, poppet properties. magnetic property characterization of lab data, NDE, eddy current inspection, simulation, eddy current criteria, poppet cycle testing and NDE criteria, and the use of ultrasonic surface wave for crack detection.

Koshti, Ajay↗

Mechanical and Combustion Performance of Multi-Walled Carbon Nanotubes as an Additive to Paraffin-Based Solid Fuels for Hybrid Rockets

Paraffin-based solid fuels for hybrid rocket motor applications are recognized as a fastburning alternative to other fuel binders such as HTPB, but efforts to further improve the burning rate and mechanical properties of paraffin are still necessary. One approach that is considered in this study is to use multi-walled carbon nanotubes (MWNT) as an additive to paraffin wax. Carbon nanotubes provide increased electrical and thermal conductivity to the solid-fuel grains to which they are added, which can improve the mass burning rate. Furthermore, the addition of ultra-fine aluminum particles to the paraffin/MWNT fuel grains can enhance regression rate of the solid fuel and the density impulse of the hybrid rocket. The multi-walled carbon nanotubes also present the possibility of greatly improving the mechanical properties (e.g., tensile strength) of the paraffin-based solid-fuel grains. For casting these solid-fuel grains, various percentages of MWNT and aluminum particles will be added to the paraffin wax. Previous work has been published about the dispersion and mixing of carbon nanotubes.1 Another manufacturing method has been used for mixing the MWNT with a phenolic resin for ablative applications, and the manufacturing and mixing processes are well-documented in the literature.2 The cost of MWNT is a small fraction of single-walled nanotubes. This is a scale-up advantage as future applications and projects will require low cost additives to maintain cost effectiveness. Testing of the solid-fuel grains will be conducted in several steps. Dog bone samples will be cast and prepared for tensile testing. The fuel samples will also be analyzed using thermogravimetric analysis and a high-resolution scanning electron microscope (SEM). The SEM will allow for examination of the solid fuel grain for uniformity and consistency. The paraffin-based fuel grains will also be tested using two hybrid rocket test motors located at the Pennsylvania State University s High Pressure Combustion Lab.

Larson, Daniel B.↗

Small Payload Launch Integrated Testing Services (SPLITS) - SPSDL

My experience working on the Small Payload Launch Integrated Testing Services project has been both educational and rewarding. I have been given the opportunity to work on and experiment with a number of exciting projects and initiatives, each offering different challenges and opportunities for teamwork and collaboration. One of my assignments is to aid in the design and construction of a small-scale two stage rocket as part of a Rocket University initiative. My duties include programming a microcontroller to control the various sensors on the rocket as well as process and transmit data. Additionally, I am writing a graphical user interface application for the ground station that will receive the transmitted data from the rocket and display the information on screen along with a 3D rendering displaying the rocket orientation. Another project I am working on is to design and develop the avionics that will be used to control a high altitude balloon flight that will test a sensor called a Micro Dosimeter that will measure the total ionizing dose absorbed by electrical components during a flight. This includes assembling and soldering the various sensors and components, programming a microcontroller to input and process data from the Micro Dosimeter, and transmitting the data down to a ground station as well as save the data to an on-board SD card. Additionally, I am aiding in the setup and development of ITOS (Integrated Test and Operations System) capability in the SPSDL (Spaceport Processing System Development Lab).

Intern↗

Unsupervised Change Detection for Space Habitats Using 3D Point Clouds

This work presents an algorithm for scene change detection from point clouds to enable autonomous robotic caretaking in future space habitats. Autonomous robotic systems will help maintain future deep-space habitats, such as the Gateway space station, which will be uncrewed for extended periods. Existing scene analysis software used on the International Space Station (ISS) relies on manually-labeled images for detecting changes. In contrast, the algorithm presented in this work uses raw, unlabeled point clouds as inputs. The algorithm first applies modified Expectation-Maximization Gaussian Mixture Model (GMM) clustering to two input point clouds. It then performs change detection by comparing the GMMs using the Earth Mover’s Distance. The algorithm is validated quantitatively and qualitatively using a test dataset collected by an Astrobee robot in the NASA Ames Granite Lab comprising single frame depth images taken directly by Astrobee and full-scene reconstructed maps built with RGB-D and pose data from Astrobee. The runtimes of the approach are also analyzed in depth. The source code is publicly released to promote further development.

robotics↗

Characterization of Tri-lab β-Tin (Sn)

This report documents details of the microstructure and mechanical properties of -tin (Sn), that is used in the Tri-lab (Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratories (SNL)) collaboration project on Multi-phase Tin Strength. We report microstructural features detailing the crystallographic texture and grain morphology of as-received -tin from electron back scatter diffraction (EBSD). Temperature and strain rate dependent mechanical behavior was investigated by multiple compression tests at temperatures of 200K to 400K and strain rates of 0.0001 /s to 100 /s. Tri-lab tin showed significant temperature and strain rate dependent strength with no significant plastic anisotropy. A sample to sample material variation was observed from duplicate compression tests and texture measurements. Compression data was used to calibrate model parameters for temperature and rate dependent strength models, Johnson-Cook (JC), Zerilli-Armstrong (ZA) and Preston-Tonks-Wallace (PTW) strength models.

36 MATERIALS SCIENCE↗