Theory of inelastic multiphonon scattering and carrier capture by defects in semiconductors: Application to capture cross sections

Inelastic scattering and carrier capture by defects in semiconductors are the primary causes of hot-electron-mediated degradation of power devices, which holds up their commercial development. At the same time, carrier capture is a major issue in the performance of solar cells and light-emitting diodes. A theory of nonradiative (multiphonon) inelastic scattering by defects, however, is nonexistent, while the theory for carrier capture by defects has had a long and arduous history. As such, we report the construction of a comprehensive theory of inelastic scattering by defects, with carrier capture being a special case. We distinguish between capture under thermal equilibrium conditions and capture under nonequilibrium conditions, e.g., in the presence of an electrical current or hot carriers where carriers undergo scattering by defects and are described by a mean free path. In the thermal-equilibrium case, capture is mediated by a nonadiabatic perturbation Hamiltonian, originally identified by Huang and Rhys and by Kubo, which is equal to linear electron-phonon coupling to first order. In the nonequilibrium case, we demonstrate that the primary capture mechanism is within the Born-Oppenheimer approximation (adiabatic transitions), with coupling to the defect potential inducing Franck-Condon electronic transitions, followed by multiphonon dissipation of the transition energy, while the nonadiabatic terms are of secondary importance (they scale with the inverse of the mass of typical atoms in the defect complex). We report first-principles density-functional-theory calculations of the capture cross section for a prototype defect using the projector-augmented wave, which allows us to employ all-electron wave functions. We adopt a Monte Carlo scheme to sample multiphonon configurations and obtain converged results. The theory and the results represent a foundation upon which to build engineering-level models for hot-electron degradation of power devices and the performance of solar cells and light-emitting diodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CALiPER Exploratory Study: Accounting for Uncertainty in Lumen Measurements

With a well-defined and shared understanding of uncertainty in lumen measurements, testing laboratories can better evaluate their processes, contributing to greater consistency and credibility of lighting testing a key component of the U.S. Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) program. Reliable lighting testing is a crucial underlying factor contributing toward the success of many energy-efficient lighting efforts, such as the DOE GATEWAY demonstrations, Lighting Facts Label, ENERGY STAR® energy efficient lighting programs, and many others. Uncertainty in measurements is inherent to all testing methodologies, including photometric and other lighting-related testing. Uncertainty exists for all equipment, processes, and systems of measurement in individual as well as combined ways. A major issue with testing and the resulting accuracy of the tests is the uncertainty of the complete process. Individual equipment uncertainties are typically identified, but their relative value in practice and their combined value with other equipment and processes in the same test are elusive concepts, particularly for complex types of testing such as photometry. The total combined uncertainty of a measurement result is important for repeatable and comparative measurements for light emitting diode (LED) products in comparison with other technologies as well as competing products. This study provides a detailed and step-by-step method for determining uncertainty in lumen measurements, working closely with related standards efforts and key industry experts. This report uses the structure proposed in the Guide to Uncertainty Measurements (GUM) for evaluating and expressing uncertainty in measurements. The steps of the procedure are described and a spreadsheet format adapted for integrating sphere and goniophotometric uncertainty measurements is provided for entering parameters, ordering the information, calculating intermediate values and, finally, obtaining expanded uncertainties. Using this basis and examining each step of the photometric measurement and calibration methods, mathematical uncertainty models are developed. Determination of estimated values of input variables is discussed. Guidance is provided for the evaluation of the standard uncertainties of each input estimate, covariances associated with input estimates and the calculation of the result measurements. With this basis, the combined uncertainty of the measurement results and finally, the expanded uncertainty can be determined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An ultra-efficient energy transfer beyond plasmonic light scattering

The energy transfer between nano-particles is of great importance for, solar cells, light-emitting diodes, nano-particle waveguides, and other photonic devices. This study shows through novel design and algorithm optimization, the energy transfer efficiency between plasmonic and dielectric nano-particles can be greatly improved. Using versatile designs including core-shell wrapping, supercells and dielectric mediated plasmonic scattering, 0.05 dB/μm attenuation can be achieved, which is 20-fold reduction over the baseline plasmonic nano-particle chain, and 8-fold reduction over the baseline dielectric nano-particle chain. In addition, it is also found that the dielectric nano-particle chains can actually be more efficient than the plasmonic ones, at their respective optimized geometry. The underlying physics is that although plasmonic nano-particles provide stronger coupling and field emission, the effect of plasmonic absorption loss is actually more dominant resulting in high attenuation. Finally, the group velocity for all design schemes proposed in this work is shown to be maintained above 0.4c, and it is found that the geometry optimization for transmission also boosts the group velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Site-controlled InGaN/GaN single-photon-emitting diode

We report single-photon emission from electrically driven site-controlled InGaN/GaN quantum dots. The device is fabricated from a planar light-emitting diode structure containing a single InGaN quantum well, using a top-down approach. The location, dimension, and height of each single-photon-emitting diode are controlled lithographically, providing great flexibility for chip-scale integration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heterovalent Substitution of K 2 SrP 2 O 7 :Cr 3+ to Achieve Anti-Thermal-Quenching Broadband Near-Infrared Luminescence

Broadband near-infrared (NIR) light sources based on phosphor-converted light-emitting diodes are highly desirable for biochemical analysis and medical diagnosis applications. However, thermal quenching remains a demanding challenge for developing efficient NIR phosphors. Herein, we report the enhancement of both quantum efficiency and thermal stability in Cr 3+ -activated K 2 SrP 2 O 7 phosphors through a heterovalent substitution strategy by replacing Sr 2+ with Al 3+ in K 2 Sr 1–x Al x P 2 O 7 (0.05 ≤ x ≤ 0.2) to obtain optimized broadband NIR emission. Structural modulation via Al 3+ substitution leads to the optimized composition, K 2 Sr 0.88 Al 0.1 P 2 O 7 :0.02Cr 3+ , which emits across a broad NIR range of 650–1100 nm peaking at 807 nm with a full width at half-maximum of ∼130 nm under 448 nm excitation. Remarkably, its emission intensity at 150 °C remains 120% of the initial value at room temperature, demonstrating a rare antithermal-quenching behavior. Temperature-dependent XRD studies further reveal that Al 3+ substitution effectively suppresses lattice expansion at elevated temperatures, indicating enhanced lattice stability under thermal excitation. Detailed structural and spectral analyses show that the substitution enhances local site symmetry, reduces electron–phonon coupling, increases thermally induced absorption probability, and fortifies energetic barriers against nonradiative transitions. These synergistic effects collectively endow this NIR phosphor with a superior thermal stability. Furthermore, NIR light-emitting diodes fabricated with this phosphor exhibit strong potential for applications in information identification, nondestructive detection, and night vision technologies. This study demonstrates a local structure engineering strategy for designing thermally robust Cr 3+ -activated NIR phosphors, offering valuable insights into material discovery and NIR spectroscopy device development.

Cr3+↗

Pressure-Induced Stacking of Rhodamine 6G Molecules

Extended conjugation of molecular π systems are of great significance for solar cells and organic light-emitting diodes as these can serve as new light absorbing and emitting chromophores. This research demonstrates the potential of using pressure and solvent environment to create larger assemblies of molecular π-conjugated systems. Here, we selected rhodamine 6G (Rh6G) to study the pressure-induced stacking of molecules in three different solvents: methanol (MeOH), isopropanol (IPA), and 16:3:1 mixture of methanol: ethanol: water (MEW). Absorption, emission, and fluorescence lifetime were studied at pressures up to 11.38 GPa. We found that pressure-induced stacking mechanisms can present solvent dependence: high pressures tend to create emissive Haggregates in MeOH and MEW, but excimers in IPA. This work guides and demonstrates routes to stacking of organic molecules using high pressures and provides fundamental insights into the formation of extended conjugation π systems.

Johnson, Kade [Univ. of Texas at San Antonio, TX (↗

Optical Signatures of Transiently Disordered Semiconductor Nanocrystals

The remarkable optoelectronic properties of semiconductor nanocrystals (NCs) have led to efforts to integrate them as the active material in light-emitting diodes, solid-state-lighting, and lasers. Understanding related high carrier injection conditions is therefore critical as resultant thermal effects can impact optical properties. The physical integrity of the NC is indeed questionable as recent transient X-ray diffraction studies have suggested that NCs reversibly lose crystalline order, or melt, under high fluence photoexcitation. Informed by such studies, here, we examine CdSe NCs under elevated fluences to determine the impact of disordering on optical properties. To this end, we implement intensity-dependent transient absorption using both one- and two-pump methods where the latter effectively subtracts out the NC optical signatures associated with lower fluence photoexcitation, especially band-edge features. At elevated fluences, we observe a long-lived induced absorption to the red of the bandgap across a wide range of sizes that follows power dependent trends and kinetics consistent with the prior transient X-ray measurements. NC photoluminescence studies provide further evidence that melting influences optical properties. These methods of characterizing bandgap narrowing caused by NC disordering could facilitate improved optical amplification and band-edge emission at high excitation density.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hazardous Gas Detection Sensor Using Broadband Light-Emitting Diode-Based Absorption Spectroscopy for Space Applications

As space travel matures and extended duration voyages become increasingly common, it will be necessary to include arrays of early fire detection systems aboard spacefaring vessels, space habitats, and in spacesuits. As gasses that are relevant to combustion and pyrolysis have absorption features in the midinfrared range, it is possible to utilize absorption spectroscopy as a means of detecting and quantifying the concentration of these hazardous compounds. Within this work, a sensor for detecting carbon dioxide has been designed and tested autonomously on a high-altitude balloon flight. The sensor utilizes a 4.2-mm lightemitting diode source, amplitude modulation to characterize species concentrations, and frequency modulation to characterize ambient temperature. Future work will include expanding the sensor design to detect other gases, and demonstrating suborbital flight capability.

47 OTHER INSTRUMENTATION↗

Cavity Attenuated Phase Shift (CAPS) Monitor Instrument Handbook

The CAPS PMex monitor is a cavity attenuated phase shift extinction instrument. It operates as an optical extinction spectrometer, using a visible-light-emitting diode (LED) as the light source, a sample cell incorporating two high-reflectivity mirrors centered at the wavelength of the LED, and a vacuum photodiode detector. Its efficacy is based on the fact that aerosols are broadband scatterers and absorbers of light.

54 ENVIRONMENTAL SCIENCES↗

Two-Column Aerosol Project: Aerosol Light Extinction Measurements Field Campaign Report

We deployed Aerodyne Research Inc.’s first Cavity Attenuated Phase Shift extinction (CAPS PMex) monitor (built by Aerodyne) that measures light extinction by using a visible-light-emitting diode (LED) as a light source, a sample cell incorporating two high-reflectivity mirrors centered at the wavelength of the LED, and a vacuum photodiode detector in Cape Cod in 2012/13 for the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Two-Column Aerosol Project (TCAP). The efficacy of this instrument is based on the fact that aerosols are broadband scatterers and absorbers of light. The input LED is square-wave modulated and passed through the sample cell that distorts it due to exponential decay by aerosol light absorption and scattering; this is measured at the detector. The amount of phase shift of the light at the detector is used to determine the light extinction. This extinction measurement provides an absolute value, requiring no calibration. The goal was to compare the CAPS performance with direct measurements of absorption with ARM’s baseline photoacoustic soot spectrometer (PASS-3) and nephelometer instruments to evaluate its performance.

54 ENVIRONMENTAL SCIENCES↗

Red-light-emitting laser diodes operating CW at room temperature

Heterojunction laser diodes of AlGaAs have been prepared with threshold current densities substantially below those previously achieved at room temperature in the 7200-8000-A spectral range. These devices operate continuously with simple oxide-isolated stripe contacts to 7400 A, which extends CW operation into the visible (red) portion of the spectrum.

Kressel, H.↗

Automatic Guidance for Remote Manipulator

Position sensor and mirror guides manipulator toward object. Grasping becomes automatic when sensor begins to receive signal from reflector on object to be manipulated. Light-emitting diodes on manipulator produce light signals for reflector, which is composite of plane and corner reflectors. Proposed scheme especially useful when manipulator arm tends to flex or when object is moving. Sensor and microprocessor designed to compensate for manipulatorarm oscillation.

Johnston, A. R.↗

Director's discretionary fund report for FY 1991

The Director's Discretionary Fund (DDF) at the Ames Research Center was established to fund innovative, high-risk projects in basic research which would otherwise be difficult to initiate, but which are essential to our future programs. Here, summaries are given of individual projects within this program. Topics covered include scheduling electric power for the Ames Research Center, the feasibility of light emitting diode arrays as a lighting source for plant growth chambers in space, plasma spraying of nonoxide coatings using a constricted arcjet, and the characterization of vortex impingement footprint using non-intrusive measurement techniques.

Source record↗

Birefringence-balanced polarimetric optical fiber sensor for high-temperature measurements

A birefringence-balanced polarimetric multimode fiber temperature sensor is proposed and demonstrated. Two single-crystal sapphire rods are incorporated into the sensor head. They are connected end to end in such a way that the slow axis of the first rod is aligned with the fast axis of the second rod, referred to as the referencing rod. Since the lengths of the two rods are chosen to be almost the same, the original birefringence of the first rod is balanced by that of the second rod. A light-emitting diode serves as the light source. This sensor has been experimentally demonstrated for high-temperature measurements as high as 1500 C. A sensitivity of 5 C has been obtained.

Wang, Anbo↗

Optically Driven Q-Switches For Lasers

Optically driven Q-switches for pulsed lasers proposed, taking place of acousto-optical, magneto-optical, and electro-optical switches. Optical switching beams of proposed Q-switching most likely generated in pulsed diode lasers or light-emitting diodes, outputs of which are amplitude-modulated easily by direct modulation of relatively small input currents. Energy efficiencies exceed those of electrically driven Q-switches.

Hemmati, Hamid↗

Micro-Spectrometer for Resource Mapping in Extreme Environments

Measurements and analyses of resources within permanently shadowed craters and along steep embankments on extraterrestrial surfaces pose extreme challenges since astronauts and rovers cannot access them. However, these areas offer the potential for the greatest scientific returns. Researchers at the NASA Langley Research Center (LaRC) invented a deployable wireless micro-spectrometer that can access those challenging areas and deliver telemetry data to a receiver safely outside those extreme environments. The micro-spectrometers are designed for deployment by an astronaut, a rover, or a lander flying overhead. This device can also be installed on rover tires, under the astronaut’s shoes, or on a cane stick. The bullet-like, expendable micro-spectrometer can penetrate into soil to spectrally identify the components of soil, such as water, He-3, or other minerals. The signals from the soil assay data are transmitted to a mother station through a telemetry system. This LaRC developed micro-spectrometer bullet consists of micro-spectrometer optics with an all-imbedded, burst-mode, light-emitting-diode ultraviolet (LED UV) light source, a super-capacitor with control electronics, and telemetry electronics. Prototypes have been fabricated to demonstrate a spectral assay of soil components. Further maturation of this technology would be necessary for demonstrations on the Moon.

micro-spectrometer↗

Abstract: Orion Lighting Workaround for Maintaining Crew Circadian Entrainment

Introduction. Light is the major environmental time cue of our endogenous circadian pacemaker. Suboptimal crew circadian entrainment (CCE) is common and associated with acute and chronic medical symptoms. Additionally, fatigue from suboptimal CCE promotes problematic use of sleep medications. The Orion Cabin Lighting System (OCLS) consists of monochromatic light-emitting diode (LED) lamps. However, light is a powerful suppressor of melatonin and it is a disruptor of CCE if used at incorrect times. A commercial off the shelf (COTS) dynamic lighting system (COTS-DLS) is a potential workaround for maintaining CCE.

Matthew Lindsey↗

LED Intensity Decay Particle Tracking Velocimetry

A particle tracking velocimetry (PTV) system is demonstrated that eliminates the need for expensive lasers and cameras, and encodes the particle tracks with a known intensity variation which allows for high-resolution particle velocity and directionality determination. Using a light-emitting diode (LED) as the light source significantly reduces cost and allows for eye-safe operation, in comparison to traditional laser systems. The intensity variation control is passive, being dictated by the capacitance discharge rate in the LED pulsing circuit. The decay rate can be adjusted with the LED circuit capacitors/resistors, while the duration of the decay can be adjusted with the LED trigger pulse width. Because the intensity decay illumination is controlled by the LED, a single long exposure camera image is used to acquire images of the particle streaks, and there is no need for a more complicated and costly double-pulsing camera. With the intensity coding of the light, a single-camera/ single-LED system can identify particles entering of leaving the illumination plane, but cannot discern the direction toward or away from the camera. By using a two-color system, three-dimensionality of the particle tracks can be determined.

Joshua M Weisberger↗