Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Measurement of time dependent CP asymmetry parameters in B0 meson decays to omegaKs, etaprimeKz, and pi0Ks

The authors present measurements of the time-dependent CP-violation parameters S and C in the decays B{sup 0} {yields} {omega}K{sub S}{sup 0}, B{sup 0} {yields} {eta}{prime}K{sup 0}, reconstructed as {eta}{prime}K{sub S}{sup 0} and {eta}{prime}K{sub L}{sup 0}, and B{sup 0} {yields} {pi}{sup 0}K{sub S}{sup 0}. The data sample corresponds to the full BABAR dataset of 467 x 10{sup 6} B{bar B} pairs produced at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the Stanford Linear Accelerator Center. The results are S{sub {omega}K{sub S}{sup 0}} = 0.55{sub -0.29}{sup +0.26} {+-} 0.02, C{sub {omega}K{sub S}{sup 0}} = -0.52{sub -0.20}{sup +0.22} {+-} 0.03, S{sub {eta}{prime}K{sup 0}} = 0.57 {+-} 0.08 {+-} 0.02, C{sub {eta}{prime}K{sup 0}} = -0.08 {+-} 0.06 {+-} 0.02, S{sub {pi}{sup 0}K{sub S}{sup 0}} = 0.55 {+-} 0.20 {+-} 0.03, and C{sub {pi}{sup 0}K{sub S}{sup 0}} = 0.13 {+-} 0.13 {+-} 0.03, where the first errors are statistical and the second systematic. These results are consistent with the previous measurements and the world average of sin2{beta} measured in B{sup 0} {yields} J/{psi}K{sub S}{sup 0}.

43 PARTICLE ACCELERATORS↗

Measurement of the Branching Fraction, Polarization, and CP Asymmetries in B0->rho0rho0 Decay, and Implications for the CKM Angle alpha

We study B{sup 0} {yields} {rho}{sup 0}{rho}{sup 0} decays in a sample of 465 x 10{sup 6} {Upsilon}(4S) {yields} B{bar B} events collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider located at the Stanford Linear Accelerator Center (SLAC). We measure the branching fraction {Beta} = (0.92 {+-} 0.32 {+-} 0.14) x 10{sup -6} and longitudinal polarization fraction f{sub L} = 0.75{sub -0.14}{sup +0.11} {+-} 0.04, where the first uncertainty is statistical and the second is systematic. The evidence for the B{sup 0} {yields} {rho}{sup 0}{rho}{sup 0} signal has a significance of 3.1 standard deviations, including systematic uncertainties. We investigate the proper-time dependence of the longitudinal component in the decay and measure the CP-violating coefficients S{sub L}{sup 00} = (0.3 {+-} 0.7 {+-} 0.2) and C{sub L}{sup 00} = (0.2 {+-} 0.8 {+-} 0.3). They study the implication of these results for the unitarity triangle angle {alpha}.

43 PARTICLE ACCELERATORS↗

Surface-loss power calculations for the LANSCE DTL

The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.

43 PARTICLE ACCELERATORS↗

The DARHTAcquisition, Archival, Analysis, And Instrument Control System (DAAAC), And Network Infrastructure

The Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) at Los Alamos National Laboratory is the world's most advanced weapons test facility. DARHT contains two linear accelerators for producing flash radiographs of hydrodynamic experiments. High-speed electronics and optical instrumentation are used for triggering the accelerators and collecting accelerator data. Efficient and effective diagnostics provide basic information needed to routinely tune the accelerators for peak radiographic performance, and to successfully monitor the accelerators performance. DARHT's server and network infrastructure is a key element in providing shot related data storage and retrieval for successfully executing radiographic experiments. This paper will outline the elaborate Data Acquisition, Archival, Analysis, and Instrument Control System (DAAAC), as well as the server and network infrastructure for both accelerators.

43 PARTICLE ACCELERATORS↗

Production mechanism of exotic nuclei in SPIRAL 2

In the near future, the accelerator and experimental facilities at GANIL (Caen/France) will be extended by a new facility called SPIRAL2. It will be based on a superconducting linear accelerator which will deliver a 40-MeV deuteron beam (5 mA; 200 kW). These accelerated particles will produce a very high neutron flux with a fast spectrum (most probable neutron energy is about 14 MeV with an extension to 40 MeV). With the neutron-induced fission of the natural uranium, intense beams of neutron-rich nuclei will be created and will become available at SPIRAL2. In this work, done with the support of SAFERIB and EURONS, we present the results of the modelling of the uranium carbide target. The modelling was mainly done with the code MCNPX26B. The target is theoretically optimised to produce a global fission rate greater than 5x10{sup 13} fissions.s{sup -1}. In fact, the optimised target, of 2.3 kg of carbide uranium, has a calculated fission rate closer to about 6x10{sup 13} fissions.s{sup -1}.

43 PARTICLE ACCELERATORS↗

Overview of the High Intensity Neutrino Source Linac R&D program at Fermilab

The Fermilab High Intensity Neutrino Source (HINS) Linac R&D program is building a first-of-a-kind 60 MeV superconducting H- linac. The HINS Linac incorporates superconducting solenoids for transverse focusing, high power RF vector modulators for independent control of multiple cavities powered from a single klystron, and superconducting spoke-type accelerating cavities starting at 10 MeV. This will be the first application and demonstration of any of these technologies in a low-energy, high-intensity proton/H- linear accelerator. The HINS effort is relevant to a high intensity, superconducting H- linac that might serve the next generation of neutrino physics and muon storage ring/collider experiments. An overview of the HINS program, machine design, status, and outlook is presented.

43 PARTICLE ACCELERATORS↗

Spiral 2 cryogenic system overview: Design, construction and performance test

The new particle accelerator project Spiral 2 at GANIL (“Grand Accélérateur d’Ions Lourds, i.e. National Large Heavy Ion Accelerator) in Caen (France) is a very large installation, intended to serve fundamental research in nuclear physics. The heart of the future machine features a superconductor linear accelerator, delivering a beam until 20Mev/A, which are then used to bombard a matter target. The resulting reactions, such as fission, transfer, fusion, etc. will generate billions of exotic nuclei. To achieve acceleration of the beam, 26 cavities which are placed inside cryomodules at helium cryogenic temperature will be used. AL-AT (Air Liquide Advanced Technologies) takes part to the project by supplying cryogenic plant. The plant includes the liquefier associated to its compressor station, a large dewar, a storage tank for helium gas and transfer lines. In addition, a helium recovery system composed of recovery compressor, high pressure storage and external purifier has been supplied. Customized HELIAL LF has been designed, manufactured and tested by AL-AT to match the refrigeration power need for the Spiral 2 project which is around 1300 W equivalent at 4.5 K.

43 PARTICLE ACCELERATORS↗

The Tandem-ALPI-PIAVE accelerator complex of LNL

Heavy ion beams are delivered at the Laboratori Nazionali di Legnaro by the accelerator complex Tandem-ALPI-PIAVE. The Tandem XTU is a Van de Graaff accelerator normally operated at terminal voltages of up to about 15 MV. The Tandem accelerator can be operated in stand-alone mode or as an injector for the linac booster ALPI. The linear accelerator ALPI is built of superconducting resonant cavities and consists of a low-beta branch, particularly important for the acceleration of the heavier mass ions, a medium-beta branch, and a high-beta branch. ALPI can be operated also with the PIAVE injector that consists of a superconducting linac and an ECR source. The PIAVE source was mainly used for the acceleration of intense noble gas beams but most recently also a first metallic beam was delivered to the users. The accelerator complex delivers beams of ions from protons to gold in three experimental areas on 11 different beam lines. A rich scientific activity is ongoing at the Tandem-ALPI-PIAVE accelerator complex, beam time being shared between nuclear physics research and applied and interdisciplinary physics research. An overview of the present status and perspectives of the Tandem-ALPI-PIAVE complex and its physics program is given in the present paper.

43 PARTICLE ACCELERATORS↗

An accelerator based fusion-product source for development of inertial confinement fusion nuclear diagnostics

A fusion-product source, utilizing a 150 kV Cockraft-Walton linear accelerator, has been refurbished to provide a reliable nuclear diagnostic development tool to the national inertial confinement fusion (ICF) research program. The accelerator is capable of routinely generating DD reaction rates at {approx}10{sup 7}/s when using a 150 kV, 150 {mu}A deuterium (D) beam onto an erbium (Er) or titanium (Ti) target doped with D, and D{sup 3}He reaction rates at {approx}5x10{sup 5}/s when using a using a 120 kV, {approx}100 {mu}A D beam onto a Er or Ti target doped with {sup 3}He. The new accelerator is currently being used in a number of projects related to the national ICF program at the OMEGA Laser Fusion Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], which includes the wedge range filter charged-particle spectrometry program [F. H. Seguin et al., Rev. Sci Instrum. 75, 3520 (2004)] and the magnetic recoil neutron spectrometer [J. A. Frenje et al., Rev. Sci. Instrum. 72, 854 (2001)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Engineering Prototype for a Compact Medical Dielectric Wall Accelerator

A compact accelerator system architecture based on the dielectric wall accelerator (DWA) for medical proton beam therapy has been developed by the Compact Particle Acceleration Corporation (CPAC). The major subsystems are a Radio Frequency Quadrupole (RFQ) injector linac, a pulsed kicker to select the desired proton bunches, and a DWA linear accelerator incorporating a high gradient insulator (HGI) with stacked Blumleins to produce the required acceleration energy. The Blumleins are switched with solid state laser-driven optical switches integrated into the Blumlein assemblies. Other subsystems include a high power pulsed laser, fiber optic distribution system, electrical charging system, and beam diagnostics. An engineering prototype has been constructed and characterized, and these results will be used within the next three years to develop an extremely compact 150 MeV system capable of modulating energy, beam current, and spot size on a shot-to-shot basis. This paper presents the details the engineering prototype, experimental results, and commercialization plans.

43 PARTICLE ACCELERATORS↗

Cryogenic supply for accelerators and experiments at FAIR

In the coming years the new international accelerator facility FAIR (Facility for Antiproton and Ion Research), one of the largest research projects worldwide, will be built at GSI. In the final construction FAIR consists of synchrotrons and storage rings with up to 1,100 meters in circumference, two linear accelerators and about 3.5 kilometers beam transfer lines. The existing GSI accelerators serve as pre-accelerators. Partly the new machines will consist of superconducting magnets and therefore require a reliable supply with liquid helium. As the requirements for the magnets is depending on the machine and have a high variety, the cooling system is different for each machine; two phase cooling, forced flow cooling and bath cooling respectively. In addition the cold mass of the individual magnets varies between less than 1t up to 80t and some magnets will cause a dynamic heat load due to ramping that is higher than the static loads. The full cryogenic system will be operated above atmospheric pressure. The refrigeration and liquefaction power will be provided by two main cryogenic plants of 8 and 25 kW at 4K and two smaller plants next to the experiments.

43 PARTICLE ACCELERATORS↗

Postoperative Radiotherapy for Lung Cancer: Improvement in Locoregional Control Using Three-Dimensional Compared With Two-Dimensional Technique

Purpose: To determine whether lung cancer patients treated with three-dimensional (3D) postoperative radiotherapy (PORT) have more favorable outcomes than those treated with two-dimensional (2D) PORT. Patients and Methods: We retrospectively analyzed the charts of 153 lung cancer patients who underwent PORT with curative intent at our center between 1995 and 2007. The patients were grouped according to the RT technique; 66 patients were in the 2D group and 87 in the 3D group. The outcomes included locoregional control, survival, and secondary effects. All patients were treated using a linear accelerator at a total dose of approximately 50 Gy and 2 Gy/fraction. A few patients (21%) also received chemotherapy. Most tumors were in the advanced stage, either Stage II (30%) or Stage III (65%). The main clinical indications for PORT were positive resection margins (23%) and Stage pN2 (52%) and pN1 (22%). The patient characteristics were comparable in both groups. Results: Kaplan-Meier analysis showed that the 3D technique significantly improved the locoregional control rate at 5 years compared with the 2D technique (81% vs. 56%, p = .007 [Cox]). The 2D technique was associated with a more than twofold increased risk of locoregional recurrence (hazard ratio, 2.7; 95% confidence interval, 1.3-5.5; p = .006). The overall survival rate did not differ at 5 years (38% vs. 20%, p = .3 [Cox]). The toxicities were also similar and acceptable in both groups. Conclusion: The 3D technique for conformal PORT for lung cancer improved the locoregional control rates of patients compared with the 2D technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rossendorf SRF-Gun Cavity Characteristics

At the Forschungszentrum Dresden-Rossendorf the development and the setup of the 2nd superconducting radio frequency photo electron injector (SRF-Photo-Gun) is finished. This new injector is placed next to the existing thermionic gun of the superconducting linear accelerator ELBE. A connection between the accelerator and the SRF-Gun will provide improved beam parameters for the users at the second half of 2009. At the moment the commissioning is fully under way. We will report on important results concerning cavity commissioning like measurements of: Q vs. E, microphonics, Lorentz detuning, tuner parameters, pressure sensibility and in-situ fundamental mode field distribution calculated from measured pass band.

43 PARTICLE ACCELERATORS↗

Observation of Polarized Positrons from an Undulator-Based Source

An experiment (E166) at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which a multi-GeV electron beam passed through a helical undulator to generate multi-MeV, circularly polarized photons which were then converted in a thin target to produce positrons (and electrons) with longitudinal polarization above 80% at 6 MeV. The results are in agreement with Geant4 simulations that include the dominant polarization-dependent interactions of electrons, positrons and photons in matter.

43 PARTICLE ACCELERATORS↗

SU-E-T-406: Evaluation of the Stealth Chamber by IBA Under Large Field Conditions

Purpose: To evaluate the performance of the stealth chamber by IBA under large field conditions. Methods: Measurement of PDDs and profiles for fields of 10×10, 15×15, 20×20 and 25×25 cm2 were acquired in a blue phantom2 scanning system for 6 and 15 MV beams in a Varian TrueBeam linear accelerator. The stealth chamber has a field size limit of 25×25 cm2. Measurements with two different detector set were performed. First a cc13 chamber as field and reference chamber was acquired. And with a cc13 chamber as field detector and the stealth chamber as the reference chamber. PDDs for the fields mentioned above were conducted and profiles with the same fields at depth of dmax, 5, 10 and 20 cm were acquired for comparison. Results: Examination of the PDDs and profile comparison with a criterion of 1% and 1 mm agreement was performed. Very good agreement between the cc13 and stealth chamber set was observed within the chosen criterion. Conclusion: This work indicates the comparable results obtained with the use of the stealth chamber and cc13 as the reference chamber in relative dosimetry measurements.

43 PARTICLE ACCELERATORS↗

Measurement of the $\bar{B}$ 0 → D *+ ℓ - $\bar{v}$ Branching Fraction with a Partial Reconstruction Technique

Presented is a precise measurement of the $\bar{B}$ 0 → D* + ℓ - $\bar{v}$ ℓ branching fraction using 81.47 fb -1 of data collected with the BABAR detector at the PEP-II e + e - storage ring at the Stanford Linear Accelerator Center. The measurement was performed by partially reconstructing the D* + meson from $\bar{B}$ 0 → D* + ℓ - $\bar{v}$ ℓ decays using only the soft pion of the D* + → D 0 π + decay to reconstruct its four vector. The branching fraction was measured to be β($\bar{B}$ 0 → D* + ℓ - $\bar{v}$ ℓ ) = (4.91 ± 0.01 stat ± 0.15 syst )%.

43 PARTICLE ACCELERATORS↗