Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Experimental demonstration of higher-order Laguerre-Gauss mode interferometry

The compatibility of higher-order Laguerre-Gauss (LG) modes with interferometric technologies commonly used in gravitational wave detectors is investigated. In this paper, we present the first experimental results concerning the performance of the LG{sub 33} mode in optical resonators. We show that the Pound-Drever-Hall error signal for a LG{sub 33} mode in a linear optical resonator is identical to that of the more commonly used LG{sub 00} mode, and demonstrate the feedback control of the resonator with a LG{sub 33} mode. We succeeded to increase the mode purity of a LG{sub 33} mode generated using a spatial-light modulator from 51% to 99% upon transmission through a linear optical resonator. We further report the experimental verification that a triangular optical resonator does not transmit helical LG modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-204: Improving Multiple Isocenter Coincidence: Elekta Beam Modulator with HexaPOD Six Degrees Couchtop

Purpose: With evolution from frame-based to image-guided SRS/SRT technique, the coincidence of multiple isocenters must be within a tight tolerance: MV, kV, table mechanical, and, in this case, HexaPOD 6° patient positioning system. Reported here is a method for improving the effectiveness of an isocenter alignment procedure which ultimately led to isocenter coincidence on an Elekta Beam Modulator LINAC equipped with 4 mm MLC leaves and a fixed secondary jaw to within a radius of 1mm. Methods: Utilizing a self-leveling laser, the Elekta ball (BB) bearing phantom (8mm steel ball), the Modus QA Isocenter Cube software, and a colleague-provided isocenter alignment method, the kV, table mechanical, and HexaPOD isocenters were localized to the MV isocenter. Isocenter coincidence was tested using the Isocenter Cube from Modus QA, brought to kV isocenter using CBCT and the HexaPOD system. MV images were taken at various gantry, collimator, and couch angles and then analyzed with the aforementioned software to determine coincidence of the 5mm steel ball at cube center with MV isocenter. To improve overall coincidence, two errors were addressed iteratively: (1) LINAC mechanical and radiation isocenter coincidence allowing each isocenter volume to have similar variations during gantry and collimator rotation and (2) collimator rotational walkout which reduced the size of both mechanical and radiation isocenters. Beam steering was performed to bring MV isocenter closer to mechanical and collimator walkout was adjusted by physically shifting the MLC bank. Initial procedures were repeated to align all isocenters and perform regular checks for consistency. Results: Post-initial alignment revealed a maximum diameter of 1.8mm for MV isocenter and maximum isocenter alignment error of up to 1.22mm radius which improved to roughly 1.0mm MV isocenter diameter and <0.71mm radius alignment error with a consistency within 0.25mm. Conclusion: With the methods described, all isocenters were brought into alignment within a radius of 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety

Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceeds the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.

60 APPLIED LIFE SCIENCES↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

spammpack, Version 2013-06-18

This library is an implementation of the Sparse Approximate Matrix Multiplication (SpAMM) algorithm introduced. It provides a matrix data type, and an approximate matrix product, which exhibits linear scaling computational complexity for matrices with decay. The product error and the performance of the multiply can be tuned by choosing an appropriate tolerance. The library can be compiled for serial execution or parallel execution on shared memory systems with an OpenMP capable compiler

Source record↗

NEONiso R Package, versions greater than 0.5.2

Carbon fluxes in terrestrial ecosystems and their response to environmental change are a major source of uncertainty in the modern carbon cycle. The National Ecological Observatory Network (NEON) presents the opportunity to merge eddy covariance (EC)-derived fluxes with CO2 isotope ratio measurements to gain insights into carbon cycle processes. Collected continuously and consistently across >40 sites, NEON EC and isotope data facilitate novel integrative analyses. However, currently provisioned atmospheric isotope data are uncalibrated, greatly limiting ability to perform cross-site analyses. Here, we present two approaches to calibrating NEON CO2 isotope ratios, along with an R package to calibrate NEON data. We find that calibrating CO2 isotopologues independently yields a lower d13C bias (<0.05‰) and higher precision (<0.40‰) than directly correcting d13C with linear regression (bias: <0.11‰, precision: 0.42‰), but with slightly higher error and lower precision in calibrated CO2 mole fraction. The magnitude of the corrections to d13C and CO2 mole fractions vary substantially by site, underscoring the need for users to apply a consistent calibration framework to data in the NEON archive. Post-calibration data sets show that site mean annual d13C correlates negatively with precipitation, temperature, and aridity, but positively with elevation. Forested and agricultural ecosystems exhibit larger gradients in CO2 and d13C than other sites, particularly during the summer and at night. The overview and analysis tools developed here will facilitate cross-site analysis using NEON data, provide a model for other continental-scale observational networks, and enable new advances leveraging the isotope ratios of specific carbon fluxes.

Fiorella, Richard↗

Final Technical Report Under SC0018278

Work supported by the grant "Stability and Control of Burning Tokamak Plasmas with Resistive Walls" in the period Aug 2017 to Aug 2018 can be cast in three general categories: (1) linear tearing regimes and the effects on the response to error fields and resistive walls: (2) nonlinear tearing modes in the presence of error fields, with locking; and (3) energetic particle effects. In the first category, we have completed a study of tearing mode regimes with extended MHD effects, including parallel dynamics and toroidal effects, notably favorable average curvature. This work has been presented at the 2018 Sherwood Conference in Ref.[1]. This work has been published in the ArXiv in Ref.[2] and is being prepared for publication in Physics of Plasmas. A systematic study of shaping in a tokamak plasma with resistive tearing layers and a resistive wall has been presented in the Ph D dissertation[3] by Dov Rhodes, a student of Andrew Cole at Columbia University. John Finn was on Rhodes's Ph D committee, and was a co-author of a paper published in Physics of Plasmas on that work. A detailed study of nonlinear tearing modes in the presence of finite beta, favorable average curvature, and an error field has been nearly completed. In this study it was found that the response to an error field with real frequency a tearing layer agreed with analytic results, and that tearing mode saturation by flattening of the current profile as well as destabilization due to flattening of the pressure profile were important factors in the locking process. This work was presented at the 2017 APS/DPP Conference and at the 2018 Sherwood Conference. The effects of energetic ions on tearing modes was presented at the 2017 APS/DPP Conference and in the Ph D dissertation of Michael Halfmoon. John Finn served as a committee member on Halfmoon's Ph D committee. Extensions to this work including two-fluid effects were performed and presented at the APS/DPP Conference in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability and Control of Burning Tokamak Plasmas with Resistive Walls (Final Report)

Work supported by the grant, "Stability and Control of Burning Tokamak Plasmas with Resistive Walls" in the period Aug 2017 to 2023 can be cast in three general categories: (1) linear tearing regimes and the effects on the response to error fields and resistive walls: (2) nonlinear tearing modes in the presence of error fields, with locking; and (3) energetic particle effects. In the first category, we have completed a study of tearing mode regimes with extended MHD effects, including parallel dynamics and toroidal effects, notably favorable average curvature. This work has been presented at the 2018 Sherwood Conference. This work has been published in the ArXiv and is being prepared for publication in Physics of Plasmas. A systematic study of shaping in a tokamak plasma with resistive tearing layers and a resistive wall has been presented in the PhD dissertation by Dov Rhodes, a student of Andrew Cole at Columbia University. John Finn was on Rhodes's PhD committee, and was a co-author of a paper published in Physics of Plasmas on that work. A detailed study of nonlinear tearing modes in the presence of finite beta, favorable average curvature, and an error field has been nearly completed. In this study it was found that the response to an error field with real frequency a tearing layer agreed with analytic results, and that tearing mode saturation by flattening of the current profile as well as destabilization due to flattening of the pressure profile were important factors in the locking process. This work was presented at the 2017 APS/DPP Conference and at the 2018 Sherwood Conference. The effects of energetic ions on tearing modes was presented at the 2017 APS/DPP Conference and in the PhD dissertation of Michael Halfmoon. John Finn served as a committee member on Halfmoon's PhD committee. Extensions to this work including two fluid effects were performed and presented at the APS/DPP Conference in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of total ozone from satellite measurements of backscattered ultraviolet earth radiance.

Total ozone is estimated from Nimbus IV satellite measurements of the attenuation of backscattered radiances at wavelengths between 3100 and 3400 A. A measurement of the backscattered radiance at 3800 A, outside the ozone absorption band, is used to determine an equivalent Lambert albedo for the cloud-ground-haze surface viewed by the instrument. The measured relative attenuation at two wavelengths is compared with such values precomputed for a series of standard ozone profiles and corrected for the equivalent Lambert albedo. Total ozone is obtained by interpolation. Two alternative methods are used to assign an equivalent Lambert albedo at the absorbing wavelengths. Total ozone values estimated by these methods are compared with the Dobson (ground-truth) data by linear regression. The available evidence suggests that the true standard error of the satellite data may be 0.015 atm-cm or less for solar zenith angles smaller than 60 deg.

Mateer, C. L.↗

A unified development of several techniques for the representation of random vectors and data sets

Linear vector space theory is used to develop a general representation of a set of data vectors or random vectors by linear combinations of orthonormal vectors such that the mean squared error of the representation is minimized. The orthonormal vectors are shown to be the eigenvectors of an operator. The general representation is applied to several specific problems involving the use of the Karhunen-Loeve expansion, principal component analysis, and empirical orthogonal functions; and the common properties of these representations are developed.

Bundick, W. T.↗

Numerical marching techniques for fluid flows with heat transfer

The finite difference formulation and method of solution is presented for a wide variety of fluid flow problems with associated heat transfer. Only a few direct results from these formulations are given as examples, since the book is intended primarily to serve a discussion of the techniques and as a starting point for further investigations; however, the formulations are sufficiently complete that a workable computer program may be written from them. In the appendixes a number of topics are discussed which are of interest with respect to the finite difference equations presented. These include a very rapid method for solving certain sets of linear algebraic equations, a discussion of numerical stability, the inherent error in flow rate for confined flow problems, and a method for obtaining high accuracy with a relatively small number of mesh points.

Hornbeck, R. W.↗

Multi-calculation rate simulations

It is common in real time simulations of large aerospace systems to separate the high and low frequency subsystems within the simulation and perform the integrations of the subsystems at different calculation rates. This is done to strike a balance between accuracy of calculation and capacity of the digital computer. Questions arising as to the accuracy of this structure compared to single calculation rates were studied using a linear aircraft model. Also investigated were interactions arising to cause errors worse than those expected. Problems are specifically identified and guidelines are given for selection of sample rates for multiple rate simulations.

Powell, J. D.↗

Some approximations in the linear dynamic equations of thin cylinders

Theoretical analysis is performed on the linear dynamic equations of thin cylindrical shells to find the error committed by making the Donnell assumption and the neglect of in-plane inertia. At first, the effect of these approximations is studied on a shell with classical simply supported boundary condition. The same approximations are then investigated for other boundary conditions from a consistent approximate solution of the eigenvalue problem. The Donnell assumption is valid at frequencies high compared with the ring frequencies, for finite length thin shells. The error in the eigenfrequencies from omitting tangential inertia is appreciable for modes with large circumferential and axial wavelengths, independent of shell thickness and boundary conditions.

El-Raheb, M.↗

Error indicators and accuracy improvements of finite element solutions

Practical and reliable estimators of the discretization errors in engineering problems are developed. Error indicators for identifying the regions or elements of the solution domain which are likely to have the largest discretization errors are presented, and a simple computational procedure for improving the accuracy of the finite element solutions for shell problems is given. The similarities between the proposed procedure and a preconditioned conjugate gradient (PCG) technique are identified and exploited to generate pointwise error indicators from the PCG technique. Numerical examples in the linear static analysis of shells are presented.

Noor, Ahmed K.↗

Polarization determination utilizing two arbitrarily polarized antennas

Microwave polarimeter systems typically consist of two orthogonally polarized receiving antennas. Formulas for extracting the unknown polarization antennas with known polarization states are presented. Numerical results are generated showing the size of the errors made by assuming perfect orthogonal polarizations (either circular or linear).

Lee, Shung-Wu↗

Neuromorphic learning of continuous-valued mappings from noise-corrupted data. Application to real-time adaptive control

The ability of feed-forward neural network architectures to learn continuous valued mappings in the presence of noise was demonstrated in relation to parameter identification and real-time adaptive control applications. An error function was introduced to help optimize parameter values such as number of training iterations, observation time, sampling rate, and scaling of the control signal. The learning performance depended essentially on the degree of embodiment of the control law in the training data set and on the degree of uniformity of the probability distribution function of the data that are presented to the net during sequence. When a control law was corrupted by noise, the fluctuations of the training data biased the probability distribution function of the training data sequence. Only if the noise contamination is minimized and the degree of embodiment of the control law is maximized, can a neural net develop a good representation of the mapping and be used as a neurocontroller. A multilayer net was trained with back-error-propagation to control a cart-pole system for linear and nonlinear control laws in the presence of data processing noise and measurement noise. The neurocontroller exhibited noise-filtering properties and was found to operate more smoothly than the teacher in the presence of measurement noise.

Troudet, Terry↗

The 'optimum' upwind advection on a triangular mesh

For advection schemes based on fluctuation splitting, a design criterion of optimizing the time step leads to linear schemes that coincide with those designed for least truncation error. A further stage of optimizing the time step using a nonlinear positivity criterion, leads to considerable further gains in resolution.

Roe, P. L.↗

Signal processing methodologies for an acoustic fetal heart rate monitor

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.

Pretlow, Robert A., III↗