Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Microstructural and crystallographic effects of sol-gel synthesized Ti-doped UO 2 sintered under reducing conditions

Titanium (Ti)-doped UO 2 microspheres of three different Ti concentrations (1000, 2000, and 4000 wppm) were synthesized using an internal gelation process. The microspheres were pressed into pellets, and a two-step heat treatment was applied to form monolithic cylindrical pellets with high densities (≥95%TD). Microstructure of these samples consisted of equiaxed grains with >300% increase in average grain size compared to the undoped UO 2 pellets. Secondary Ti-rich chemical phases corresponding to a liquid eutectic formed during sintering were observed at grain boundaries of UO 2 for samples doped with 4000 wppm Ti. Furthermore, these Ti-rich chemical phases were not observed in 1000 or 2000 wppm Ti samples at microscale using electron microscopy investigations. The 0.02–0.04% lower lattice parameter values for the Ti-doped UO 2 samples compared to the undoped UO 2 confirms the incorporation of Ti into the UO 2 lattice.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure

Diamond anvil cells (DACs) are widely used for the study of materials at high pressure. The typical diamonds used are between 1 and 3 mm thick, while the sample contained within the opposing diamonds is often just a few microns in thickness. Hence, any absorbance or scattering from diamond can cause a significant background or interference when probing a sample in a DAC. By perforating the diamond to within 50-100 {micro}m of the sample, the amount of diamond and the resulting background or interference can be dramatically reduced. The DAC presented in this article is designed to study amorphous materials at high pressure using high-energy x-ray scattering (>60 keV) using laser-perforated diamonds. A small diameter perforation maintains structural integrity and has allowed us to reach pressures >50 GPa, while dramatically decreasing the intensity of the x-ray diffraction background (primarily Compton scattering) when compared to studies using solid diamonds. This cell design allows us for the first time measurement of x-ray scattering from light (low Z) amorphous materials. Here, we present data for two examples using the described DAC with one and two perforated diamond geometries for the high-pressure structural studies of SiO{sub 2} glass and B{sub 2}O{sub 3} glass.

36 MATERIALS SCIENCE↗

Pragmatic protocols for working cleanly when measuring ice nucleating particles

We report that measuring ice nucleating particles (INPs) is critical for understanding, and modeling, cloud formation, reflectivity, and precipitation patterns. However, because INPs are very rare in the atmosphere, but abundant—sometimes alarmingly so—in the dust that covers all work surfaces, contamination during processing of collected aerosol samples can be a significant hindrance to obtaining accurate measures of INPs. In preparing this technical note, we questioned the cleanliness of every collection and processing step involved in making immersion freezing measurements of INPs re-suspended from filter samples. The aim was to identify, and then minimize, all potential sources of significant contamination, including containers and tools used to store filters and prepare liquid suspensions, gloves, work surfaces, and the polymerase chain reaction (PCR) trays commonly used for sample analysis. While plasticware released few INPs, most gloves readily shed them, but this can be mitigated by using washed cleanroom vinyl or polyethylene gloves. Work surfaces, even those that had been cleaned, were prodigious reservoirs of contaminating INPs, but simply covering them with aluminum foil will provide an INP-free surface. By applying these practices, we developed a method to reduce the background level of INPs on Nuclepore™ polycarbonate filters in our tests to 0 at -25 °C and < 20 at -27 °C, making them suitable for use in all sampling environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automation of Column-based Radiochemical Separations: A Comparison of Fluidic, Robotic, and Hybrid Architectures

Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on setting up samples and columns in parallel, and using disposable components so that no sample contacts any surface that any other sample has contacted. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL column bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions four rows of six vials below the columns. The samples are delivered to the columns via a manual 3-port valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is simpler and faster in performing anion exchange procedures for the recovery and purification of plutonium from samples.

99 GENERAL AND MISCELLANEOUS↗

Project 18-15263 X-ray Studies of Interfacial Molecular Complexes in ALSEP Back-Extraction (Research Performance Final Report)

The objective of the project was to use synchrotron X-rays to measure the molecular-scale organization of extractants, complexants, buffers, and metal ions at the organic-aqueous (liquid-liquid) interface during solvent back-extraction under conditions relevant to ALSEP (Actinide-Lanthanide Separation Process). The capability of X-ray fluorescence near total reflection (XFNTR) was extended to explore the distribution of Eu(III) between the liquid-liquid interface and bulk organic and aqueous phases which contained extractants HDEHP (bis(2-ethylhexyl) phosphoric acid) and HEHEHP (2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester), the complexant DTPA (diethylene triamine pentaacetic acid), and citric and nitric acids. Although an Am-compatible sample cell was developed, extending x-ray measurements of flat liquid-liquid interfaces to the actinide Am(III) did not prove to be possible within constraints imposed by the Advanced Photon Source. However, preliminary measurements with a drop cell may eventually provide a path forward to investigate Am(III) at a liquid interface. It was also demonstrated that competitive binding that occurs during back-extraction of lanthanide ions to either a phosphoric acid extractant (DHDP, di-hexadecyl phosphate) at the liquid interface or to complexant DTPA in the bulk aqueous phase could be reversibly tuned by X-ray exposure. Separately, X-ray measurements from the liquid-vapor interface explored the role of the aqueous solubility of HDEHP and HEHEHP and their interactions with a range of lanthanides and transition metal ions. Finally, the capability of X-ray absorption spectroscopy (EXAFS) was extended to probe metal ion coordination in lanthanide ion-extractant complexes at the liquid-vapor interface. Complementary to the specific interfacial systems studied during this project, the development of x-ray techniques expands our ability to understand ion ordering at liquid interfaces.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ANALYTICAL LABORATORY AT IDAHO NATIONAL LABORATORY COUNTING EQUIPMENT STANDARDIZATION AND QUALITY CONTROL IMPROVEMENT

The Analytical Laboratory at Idaho National Laboratory (INL) is a growing program with an emphasis on providing high quality results to customers, and an increasing focus on independent research. The Analytical Laboratory Counting Group has a number of capabilities: six gamma-ray counters, one gamma-ray sample changer, four gas flow proportional counter drawers, an auto-changing gas flow proportional counter, two liquid scintillation counters, and an alpha spectroscopy system. Other capabilities within the Analytical Laboratory include quadrupole inductively coupled plasma mass spectrometry (ICP-MS), high resolution ICP-MS, multi-collector ICP-MS, ICP atomic emission spectrometry (ICP-AES), gas mass spectrometry, thermal ionization mass spectrometry (TIMS), several glove boxes and fume hoods for sample preparation, and six interconnected hot cells for sample receipt and dissolution. In order to position the Analytical Laboratory as a world-class research institution, the Counting Group has recently begun making improvements to its analytical techniques, calibrations, standardization, and quality control procedures. A large part of this effort is to increase the level of documentation of instrument work. One project is to re-calibrate all of the gamma systems with newly purchased standards. One of the changes made in the purchase of the new standards was to lower the total activity so that the dead time of the calibration would more closely match the dead time of typical samples. Similarly, another planned project is to use new standards to re-calibration the gas flow proportional counters. Additional work has focused on testing and improving alpha spectroscopy sample preparation techniques. Plutonium separations have been tested to improve tracer recovery and to verify the separation technique in the presence of typical sample matrices. A final planned area of improvements has focused on liquid scintillation counting. One difficulty the Counting Group has encountered in liquid scintillation counting is an inflated gross alpha count relative to other analysis methods in the presence of high gross beta activity. Ideas include investigating the impact of choice of scintillation cocktail, as well as the effects of sample dilution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Consolidation and Permeability of the B1 and D1 Gas Hydrate Bearing Sands and Associated Seal Sediments of the Extended-Duration Gas Production Test Site on the Alaska North Slope

Gas hydrate, a solid combination of gas (mostly methane in nature) and water molecules stable at low temperatures and elevated pressures, occurs naturally in marine and permafrost-associated environments. Gas hydrate reservoirs, such as those in the Alaska North Slope, have been considered potential energy resources for gas production. To understand the petrophysical and geo-mechanical characteristics of the reservoir, core samples retrieved from the site of the JOGMEC-DOE-USGS collaborative gas hydrate R&D project have been analyzed in the laboratory for their hydraulic and mechanical properties. This paper focuses on both seal and reservoir samples associated with the B1 and D1 sands, which are evaluated for index properties (including porosity, grain size distribution, liquid and plastic limits, specific surface area, and specific gravity), consolidation, permeability, and water retention. Furthermore, the reservoir core samples were tested with pore-filling, laboratory-grown tetrahydrofuran hydrate, in order to assess reservoir behavior during gas production from hydrates. Under simulated in situ stress conditions, the seal and hydrate-free reservoir cores had a permeability anisotropy ratio of k h /k v = 3.0−5.0, and k h /k v = 2.4−3.0 for the reservoir tetrahydrofuran hydrate-bearing cores. The data suggest that depressurizing the reservoir to induce hydrate dissociation alters the reservoir effective permeability in three ways: permeabilities decrease due to porosity lost (e.g., the initial reservoir thickness can decrease by up to 5% upon 7 MPa depressurization), permeability increases due to the loss of solid hydrate in the pore space, and permeability anisotropy k h /k v decreases in response to the evolving pore-space geometry. We show that given the simulated in situ gas hydrate saturations (i.e., S h = 32% in core 7P-2E and S h = 21% in core 20P-4), gas production from the dissociation of tetrahydrofuran hydrate in the two tested cores results in a net increase in effective permeability and a decrease in k h /k v . This study highlights the importance of investigating seal and reservoir sediments and the impacts of depressurization on the porosity and permeability responses during production.

Geological materials↗

Anomalous electron transport in epitaxial NdNiO 3 films

The origin of simultaneous electronic, structural, and magnetic transitions in bulk rare-earth nickelates (RENiO 3 ) remains puzzling with multiple conflicting reports on the nature of these entangled phase transitions. Heterostructure engineering of these materials offers unique opportunity to decouple the metal-insulator transition (MIT) from the magnetic transition. Yet, the evolution of underlying electronic properties across these decoupled transitions remains largely unexplored. In order to address this, we have calculated Hall effect on a series of epitaxial NdNiO 3 films, spanning a variety of electronic and magnetic phases. We find that the MIT results in only a partially gapped Fermi surface, whereas the full insulating phase forms below the magnetic transition. Moreover, we also find a systematic reduction of the Hall coefficient R H in the metallic phase of these films with epitaxial strain and also a surprising transition to a negative value at large compressive strain. The partially gapped, weakly insulating, paramagnetic phase is reminiscence of pseudogap behavior of high-T c cuprates. The precursor metallic phase, which undergoes transition to the insulating phase, is a non-Fermi liquid with a temperature exponent n of resistivity of 1, whereas the exponent increases to 4/3 in the noninsulating samples. Such a nickelate phase diagram with sign reversal of R H , a pseudogap phase, and non-Fermi-liquid behavior is intriguingly similar to high-T c cuprates, giving crucial guidelines to engineer unconventional superconductivity in oxide heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

California GAMA Special Study. Development of a Capability for the Analysis of Krypton-85 in Groundwater Samples

A capability for the analysis of krypton-85 ( 85 Kr) in groundwater samples was developed at LLNL. Samples are collected by extracting gas from 2000-4000 L of groundwater at the well, yielding approximately 0.2 cm 3 STP krypton. Sample collection takes 1 to 4 hours. Krypton is purified in the laboratory using a combination of molecular sieve and activated charcoal traps, and transferred to a liquid scintillation vial. The 85 Kr activity is measured by liquid scintillation on a Quantulus 1220 liquid scintillation counter from PerkinElmer. The detection limit for a typical 0.2 cm 3 Kr sample size is 11% of the present day activity in air, corresponding to the decay corrected activity in air in 1987. The typical measurement uncertainty is below 10% for recently recharged samples. Six groundwater samples were collected, purified and counted. 85 Kr was not detected in any of the samples counted at LLNL. 85 Kr was detected by the low level counting laboratory of Bern University in all samples between 1.5 and 6.6 decays per minute per cm 3 krypton, corresponding to decay corrected activities in air between 1971 and 1985. The new capability is an excellent complement to tritium-helium, expanding the existing suite of age dating tools available to the GAMA program ( 35 S, 3 H/ 3 He, 14 C and radiogenic helium). 85 Kr can replace 3 H/ 3 He in settings where 3 H/ 3 He ages are impossible to determine (for example where terrigenic helium overwhelms tritiogenic helium) and provides additional insight into travel time distributions in complex mixed groundwater systems.

54 ENVIRONMENTAL SCIENCES↗

Defect structure of Cd{sub x}Hg{sub 1-x}Te films grown by liquid-phase epitaxy, studied by means of low-energy ion treatment

Treatment with low-energy ions and measurements of electrical parameters of samples have been used to study the defect structure of Cd{sub x}Hg{sub 1-x}Te films grown by liquid-phase epitaxy. The films contain neutral defects supposedly associated with tellurium nanoinclusions. Ion treatment electrically activates these defects, with a high concentration of donor centers ({approx}10{sup 17} cm{sup -3}) created in the films. These defects decompose in {approx}10{sup 3} min of aging at room temperature. Then the properties of the material are determined by the concentration of residual donors, which is found to be very low (down to {approx}10{sup 14} cm{sup -3}) for the films under study.

36 MATERIALS SCIENCE↗

Advanced proteomic liquid chromatography

Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput.

Environmental Molecular Sciences Laboratory↗

Nanoscale Elemental Mapping of Intact Solid–Liquid Interfaces and Reactive Materials in Energy Devices Enabled by Cryo-FIB/SEM

Many modern energy devices rely on solid–liquid interfaces, highly reactive materials, or both, for their operation and performance. The difficulty of characterizing such materials means these devices often lack high-resolution characterization in an unaltered state. Here, we demonstrate how cryogenic sample preparation and transfer can extend the capabilities of FIB/SEM techniques to solid–liquid interfaces and reactive materials common to energy devices by preserving their integrity through all stages of preparation and characterization. We additionally show how cryo-FIB/SEM paired with energy dispersive X-ray spectroscopy enables nanoscale elemental mapping of cross-sections produced in these materials and discuss strategies to achieve optimal results. Finally, we consider current limitations of the technique and propose future developments that could enhance its capabilities. Our results illustrate that cryo-FIB/SEM will be a useful technique for fields where solid–liquid interfaces or reactive materials play an important role and could, thus far, not be characterized at high resolution.

25 ENERGY STORAGE↗

Initial Investigation of Waste Feed Delivery Tank Mixing and Sampling Issues

The Hanford tank farms contractor will deliver waste to the Waste Treatment Plant (WTP) from a staging double-shell tank. The WTP broadly classifies waste it receives in terms of “Envelopes,” each with different limiting properties and composition ranges. Envelope A, B, and C wastes are liquids that can include up to 4% entrained solids that can be pumped directly from the staging DST without mixing. Envelope D waste contains insoluble solids and must be mixed before transfer. The mixing and sampling issues lie within Envelope D solid-liquid slurries. The question is how effectively these slurries are mixed and how representative the grab samples are that are taken immediately after mixing. This report summarizes the current state of knowledge concerning jet mixing of wastes in underground storage tanks. Waste feed sampling requirements are listed, and their apparent assumption of uniformity by lack of a requirement for sample representativeness is cited as a significant issue. The case is made that there is not an adequate technical basis to provide such a sampling regimen because not enough is known about what can be achieved in mixing and distribution of solids by use of the baseline submersible mixing pump system. A combined mixing-sampling test program is recommended to fill this gap. Historical Pacific Northwest National Laboratory project and tank farms contractor documents are used to make this case. A substantial investment and progress are being made to understand mixing issues at the WTP. A summary of the key WTP activities relevant to this project is presented in this report. The relevant aspects of the WTP mixing work, together with a previously developed scaled test strategy for determining solids suspension with submerged mixer pumps (discussed in Section 3) provide a solid foundation for developing a path forward.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of semivolatile organics in liquid radioactive residue using sorptive stir bar and solvent back-extraction

Current methods for semivolatiles analysis in radioactive samples can produce large volumes of radioactive solvent residue. A method utilizing stir-bar sorptive extraction has been explored in this work for its applicability to radioactive waste samples. This low solvent analytical method may accelerate remediation, minimize hazardous solvent waste, and reduce exposure risk to workers. Organic compounds (polyaromatic hydrocarbons, chlorinated aromatics, and phenolic compounds) were chosen as surrogates for common Liquid Waste System (LWS) contaminants at Savannah River Site (Aiken, SC). Stir-bar extraction parameters (extraction time, matrix modification, and effective pH range) and solvent back extraction parameters (solvent type, volume, and extraction time) were optimized experimentally for the chosen compounds. Affinity of the stir-bar extraction polymer to radionuclides Cs-137 and Am-241 was observed to determine radionuclide concentration effects. The stir-bar method achieved mean recovery of 100 ± 0.7% (1σ), relative to 114 ± 7% using solvent extraction, while reducing weekly method hands-on time by 93.4% and solvent volume consumption by 99.3%. Sensitivity was improved by 378% in simulated tank waste and 278% in real-world LWS matrix, relative to solvent extraction. This work has produced a safe and optimized method for the low solvent analysis of organics in legacy radioactive tank waste by stir-bar sorptive extraction.

GC-MS↗

Weak Coupling Effect on the Magnetic Freedericksz Transition in a Ferronematic Liquid Crystal

The magnetic Freedericksz transition in a ferronematic representing a diluted suspension of magnetic nanoparticles in an N-(4-methoxybenzylidene)-4-butylaniline (MBBA) nematic liquid crystal was experimentally studied. The transition point was determined by means of dielectric capacitance measurements in cells of different thickness for samples with various volume fractions of ferroparticles. The effect of weak coupling between the magnetic and liquid-crystal subsystems was studied. Low concentrations of quasispherical magnetic particles were shown to decrease the magnetic Freedericksz transition threshold in comparison with a pure liquid crystal. The obtained results were theoretically substantiated. The phase diagram of the suspension was plotted, and the method of estimating the energy of coupling between magnetic particles and a liquid-crystal matrix was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗