Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Computational Modeling and Simulation for Nonproliferation: The History (and Present) of Monte Carlo and the MCNP(R) Code at Los Alamos [Slides]

The emergence of the Monte Carlo method as a research tool springs from work done at Los Alamos in the 1940s.Monte Carlo and the MCNP Code have been and continue to be developed at Los Alamos for many decades. From basic science in support of understanding nuclear interaction physics to global security applications, application uses of the code are extensive. Recent R&D projects and code modernization efforts make the MCNP code a great tool for nuclear nonproliferation applications. In collaboration with nuclear safeguards experts, new training has just recently been developed to help new practitioners learn how to use the code for nuclear safeguards applications.

97 MATHEMATICS AND COMPUTING↗

MODEX ─ A Program for Calculation of the Energy Spectra of Particle Emitted in the Reactions of Pre-Equilibrium and Equilibrium Statistical Decays

The program is described intended for calculation of the energy distribution of particles, emitted by excited nucleus, using the Modified Exciton Model (MEM). The complete text of the program is presented in FORTRAN66 language. We reproduce here this 1974 JINR Communication as it was never published in a journal but it represents a historical interest as the first (in the world) Monte Carlo realization of the preequilibrium plus evaporation model, and was and still is used in dozens of countries all over the world. E.g., the current CEM03.03 and LAQGSM03.03 event-generators of the latest LANL Monte Carlo transport code MCNP6 have today modified parts from MODEX, the first Monte Carlo preequilibrium code in the world. [Abstract is in English. The 1974 JINR Communication is in Russian.]

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-376: The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method

Purpose: Secondary-neutrons having harmful influences to a human body are generated by photonuclear reaction on high-energy photon therapy. Their characteristics are not known in detail since the calculation to evaluate them takes very long time. PHITS(Particle and Heavy Ion Transport code System) Monte Carlo code since versions 2.80 has the new parameter “pnimul” raising the probability of occurring photonuclear reaction forcibly to make the efficiency of calculation. We investigated the optimum value of “pnimul” on high-energy photon therapy. Methods: The geometry of accelerator head based on the specification of a Varian Clinac 21EX was used for PHITS ver. 2.80. The phantom (30 cm * 30 cm * 30 cm) filled the composition defined by ICRU(International Commission on Radiation Units) was placed at source-surface distance 100 cm. We calculated the neutron energy spectra in the surface of ICRU phantom with “pnimal” setting 1, 10, 100, 1000, 10000 and compared the total calculation time and the behavior of photon using PDD(Percentage Depth Dose) and OCR(Off-Center Ratio). Next, the cutoff energy of photon, electron and positron were investigated for the calculation efficiency with 4, 5, 6 and 7 MeV. Results: The calculation total time until the errors of neutron fluence become within 1% decreased as increasing “pnimul”. PDD and OCR showed no differences by the parameter. The calculation time setting the cutoff energy like 4, 5, 6 and 7 MeV decreased as increasing the cutoff energy. However, the errors of photon become within 1% did not decrease by the cutoff energy. Conclusion: The optimum values of “pnimul” and the cutoff energy were investigated on high-energy photon therapy. It is suggest that using the optimum “pnimul” makes the calculation efficiency. The study of the cutoff energy need more investigation.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Techniques for Nuclear Systems - Theory Lectures

These are lecture notes for a Monte Carlo class given at the University of New Mexico. The following topics are covered: course information; nuclear eng. review & MC; random numbers and sampling; computational geometry; collision physics; tallies and statistics; eigenvalue calculations I; eigenvalue calculations II; eigenvalue calculations III; variance reduction; parallel Monte Carlo; parameter studies; fission matrix and higher eigenmodes; doppler broadening; Monte Carlo depletion; HTGR modeling; coupled MC and T/H calculations; fission energy deposition. Solving particle transport problems with the Monte Carlo method is simple - just simulate the particle behavior. The devil is in the details, however. These lectures provide a balanced approach to the theory and practice of Monte Carlo simulation codes. The first lectures provide an overview of Monte Carlo simulation methods, covering the transport equation, random sampling, computational geometry, collision physics, and statistics. The next lectures focus on the state-of-the-art in Monte Carlo criticality simulations, covering the theory of eigenvalue calculations, convergence analysis, dominance ratio calculations, bias in Keff and tallies, bias in uncertainties, a case study of a realistic calculation, and Wielandt acceleration techniques. The remaining lectures cover advanced topics, including HTGR modeling and stochastic geometry, temperature dependence, fission energy deposition, depletion calculations, parallel calculations, and parameter studies. This portion of the class focuses on using MCNP to perform criticality calculations for reactor physics and criticality safety applications. It is an intermediate level class, intended for those with at least some familiarity with MCNP. Class examples provide hands-on experience at running the code, plotting both geometry and results, and understanding the code output. The class includes lectures & hands-on computer use for a variety of Monte Carlo calculations. Beginning MCNP users are encouraged to review LA-UR-09-00380, "Criticality Calculations with MCNP: A Primer (3nd Edition)" (available at http:// mcnp.lanl.gov under "Reference Collection") prior to the class. No Monte Carlo class can be complete without having students write their own simple Monte Carlo routines for basic random sampling, use of the random number generator, and simplified particle transport simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MCNPX Improvements for Threat Reduction Applications

Enhancements contained in the current MCNPX 2.6.0 Radiation Safety Information Computational Center (RSICC) release will be presented, including stopped-muon physics, delayed neutron and photon generation, and automatic generation of source photons. Preliminary benchmarking comparisons with data taken with a muon beam at the Paul Scherrer Institute Spallation Neutron Source accelerator will be discussed. We will also describe current improvements now underway, including Nuclear Resonance Fluorescence (NRF), pulsed sources, and others. We will also describe very new work begun on a threat-reduction (TR) user interface, designed to simplify the setup of TR-related calculations, and introduce standards into geometry, sources and backgrounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmark study of TRIPOLI-4 through experiment and MCNP codes

Reliability on simulation results is essential in nuclear physics. Although MCNP5 and MCNPX are the world widely used 3D Monte Carlo radiation transport codes, alternative Monte Carlo simulation tools exist to simulate neutral and charged particles' interactions with matter. Therefore, benchmark are required in order to validate these simulation codes. For instance, TRIPOLI-4.7, developed at the French Alternative Energies and Atomic Energy Commission for neutron and photon transport, now also provides the user with a full feature electron-photon electromagnetic shower. Whereas the reliability of TRIPOLI-4.7 for neutron and photon transport has been validated yet, the new development regarding electron-photon matter interaction needs additional validation benchmarks. We will thus demonstrate how accurately TRIPOLI-4's 'deposited spectrum' tally can simulate gamma spectrometry problems, compared to MCNP's 'F8' tally. The experimental setup is based on an HPGe detector measuring the decay spectrum of an {sup 152}Eu source. These results are then compared with those given by MCNPX 2.6d and TRIPOLI-4 codes. This paper deals with both the experimental aspect and simulation. We will demonstrate that TRIPOLI-4 is a potential alternative to both MCNPX and MCNP5 for gamma-electron interaction simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo Simulations of the Nuclear Energy Deposition Inside the CARMEN-1P Differential Calorimeter Irradiated into OSIRIS Reactor

The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material. These measurements are then used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. Nuclear heating is a great deal of interest at the moment as the measurement of such heating is an important issue for MTRs reactors. This need is especially generated by the new Jules Horowitz Reactor (JHR), under construction at CEA/Cadarache 'French Alternative Energies and Atomic Energy Commission'. This new reactor, that will be operational in late 2019, is a new facility for the nuclear research on materials and fuels. Indeed the expected nuclear heating rate is about 20 W/g for nominal capacity of 100 MW. The present Monte Carlo calculation works belong to the IN-CORE (Instrumentation for Nuclear radiation and Calorimetry On line in Reactor): a joint research program between the CEA and Aix- Marseille University in 2009. One scientific aim of this program is to design and develop a multi-sensors device, called CARMEN, dedicated to the measurements of main physical parameters simultaneously encountered inside JHR's experimental channels (core and reflector) such as neutron fluxes, photon fluxes, temperature, and nuclear heating. A first prototype was already developed. This prototype includes two mock-ups dedicated respectively to neutronic measurements (CARMEN-1N) and to photonic measurements (CARMEN-1P) with in particular a specific differential calorimeter. Two irradiation campaigns were performed successfully in the periphery of OSIRIS reactor (a MTR located at Saclay, France) in 2012 for nuclear heating levels up to 2 W/g. First Monte Carlo calculations reduced to the graphite sample of the calorimeter were carried out. A preliminary analysis shows that the numerical results overestimate the measurements by about 20 %. A new approach has been developed in order to estimate the nuclear heating by two methods (energy deposition or KERMA) by considering the whole complete geometry of the sensor. This new approach will contribute to the interpretation of the irradiation campaign and will be useful to improve the out-of-pile calibration procedure of the sensor and its thermal response during irradiations. The aim of this paper is to present simulations made by using MCNP5 Monte-Carlo transport code (using ENDF/B-VI nuclear data library) for the nuclear heating inside the different parts of the calorimeter (head, rod and base). Calculations into two steps will be realized. We will use as an input source in the model new spectra (neutrons, prompt-photons and delayed-photons) calculated with the Monte Carlo code TRIPOLI-4{sup R} inside different experimental channels (water) located into the OSIRIS periphery and used during the CARMEN-1P irradiation campaign. We will consider Neutrons- Photons-Electrons and Photons-Electrons modes. We will begin by a brief description of the differential-calorimeter device geometry. Then the MCNP5 model used for the calculations of nuclear heating inside the calorimeter elements will be introduced. The energy deposition due to the prompt-gamma, delayed-gamma and neutrons, the neutron-activation of the device will be considered. The different components of the nuclear heating inside the different parts of the calorimeter will be detailed. Moreover, a comparison between KERMA and nuclear energy deposition estimations will be given. Finally, a comparison between this total nuclear heating Calculation and Experiment in graphite sample will be determined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Detailed Comparison of Multidimensional Boltzmann Neutrino Transport Methods in Core-collapse Supernovae

The mechanism driving core-collapse supernovae is sensitive to the interplay between matter and neutrino radiation. However, neutrino radiation transport is very difficult to simulate, and several radiation transport methods of varying levels of approximation are available. In this paper, we carefully compare for the first time in multiple spatial dimensions the discrete ordinates (DO) code of Nagakura, Yamada, and Sumiyoshi and the Monte Carlo (MC) code Sedonu, under the assumptions of a static fluid background, flat spacetime, elastic scattering, and full special relativity. We find remarkably good agreement in all spectral, angular, and fluid interaction quantities, lending confidence to both methods. The DO method excels in determining the heating and cooling rates in the optically thick region. The MC method predicts sharper angular features due to the effectively infinite angular resolution, but struggles to drive down noise in quantities where subtractive cancellation is prevalent, such as the net gain in the protoneutron star and off-diagonal components of the Eddington tensor. We also find that errors in the angular moments of the distribution functions induced by neglecting velocity dependence are subdominant to those from limited momentum-space resolution. We briefly compare directly computed second angular moments to those predicted by popular algebraic two-moment closures, and we find that the errors from the approximate closures are comparable to the difference between the DO and MC methods. Finally, included in this work is an improved Sedonu code, which now implements a fully special relativistic, time-independent version of the grid-agnostic MC random walk approximation.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance gain with low-enriched fuel and optimized use of neutrons

The most challenging type of reactors to convert to low-enriched fuel are high-flux research reactors, which, along with some spallation sources, are the most important neutron sources for modern neutron scattering experiments. Advanced Monte-Carlo computer codes are now available that make it possible to track neutrons from the reactor core, through neutron guides, to instruments and detectors. These 'virtual experiments' allow optimizing the performance of a research facility as a whole instead of the reactor alone. This article briefly reviews performance gains obtained for high-flux reactors during previous facility-upgrades. The Monte-Carlo code VITESS is used to compare results for typical neutron scattering experiments using obsolete versus state-of-the-art technologies. The analysis shows that performance gains due to instrument upgrades or neutron guide renewals dwarf potential neutron flux losses due to conversion to low-enriched fuel. Combined convert-and-upgrade strategies therefore offer unique opportunities for reactor operators and neutron instrument groups to significantly improve the overall performance of research facilities. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulation of a Segmented Detector for Low-Energy Electron Antineutrinos

Detection of low-energy electron antineutrinos is of importance for several purposes, such as ex-vessel reactor monitoring, neutrino oscillation studies, etc. The inverse beta decay (IBD) is the interaction that is responsible for detection mechanism in (organic) plastic scintillation detectors. Here, a detailed study will be presented dealing with the radiation and optical transport simulation of a typical segmented antineutrino detector withMonte Carlo method using MCNPX and FLUKA codes. This study shows different aspects of the detector, benefiting from inherent capabilities of the Monte Carlo simulation codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KENO V.a Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS5) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO V.a three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO V.a primer is designed to help a new user understand and use the SCALE/KENO V.a Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO V.a in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO V.a that are useful in criticality analyses. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface (GUI). Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO V.a input and allows the user to quickly run a simple criticality problem with SCALE/KENO V.a. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO V.a features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO V.a. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO V.a. Complete descriptions are provided in the SCALE/KENO V.a manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO V.a training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO V.a for criticality analyses; the SCALE/KENO V.a manual provides information on the use of SCALE/KENO V.a and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata and sample inputs are also available at https://code.ornl.gov/scale/primers/kenova.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KENO-VI Primer: A Primer for Criticality Calculations with SCALE/KENO-VI Using GeeWiz

The SCALE (Standardized Computer Analyses for Licensing Evaluation) computer software system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analyses. The primer is based on SCALE 6, which includes the Graphically Enhanced Editing Wizard (GeeWiz) Windows user interface. Each example uses GeeWiz to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO-VI features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using GeeWiz to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI documentation. (The SCALE manual is provided on the SCALE installation DVD.) The primer provides specific examples of using SCALE/KENO-VI for criticality analyses; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files.

42 ENGINEERING↗

Implementation and Comparison of Different Algorithms for on the fly Doppler Broadening in RMC Code

Accurate cross sections are of great importance to Monte Carlo particle transport calculation codes which use pointwise cross sections. It is well known that cross sections have much dependence on temperature on account of Doppler effect which is particularly vital for resonance absorption cross sections. In general, pre-prepared continuous-energy libraries are used in Monte Carlo codes, which is feasible in many applications. However, in multi-physics calculations where neutronics and thermal hydraulics are coupled, cross sections at a fine interval of temperatures are desired, which brings a great challenge to computer memory. Consequently, different methods about on the fly Doppler broadening for cross sections are proposed, which can generate cross sections at the specific temperature points during neutron simulations. These methods can be roughly classified into two categories: one is to calculate the required cross sections by different algorithms, such as interpolation using a high order function expansion, multipole representation, and different integration algorithms based on Doppler broadening equation. The other, for instance, target motion sampling (TMS), does not calculate the Doppler broadening cross sections but takes into account Doppler effect by rejection technique. In this paper, several on the fly Doppler broadening algorithms based on Doppler broadening equation are implemented in the Reactor Monte Carlo code RMC, and then the accuracy and efficiency are discussed and compared. In this paper, several algorithms for on the fly Doppler broadening based on Doppler broadening equation have been implemented in RMC and the focus falls on the comparison of the Gauss Legendre quadrature and Gauss Hermite quadrature. Gauss Legendre quadrature is more accurate than Gauss Hermite quadrature but also more time consuming. Base temperature has a significant impact on Gauss Hermite quadrature while increasing base temperature to room temperature (300 K) can give satisfactory results. In addition, the proportion of overhead of Doppler broadening treatment in total computational time tends to decrease with an increase number of nuclides in fuel. For depletion calculation, both algorithms are in good agreement with reference and the relative errors of K{sub inf} are within 5 times of standard deviation. As for total computational time, the ratio between Gauss Legendre quadrature or Gauss Hermite quadrature and reference decreases and reaches 9.6 or 3.4 at last, respectively. Four important isotopes are chosen to compare the atom density and all relative errors are within 0.25%. After comparisons of different algorithms and different base temperatures, it can be found that Gauss Hermite quadrature broadening from 300 K can perform on the fly cross section Doppler broadening with least total computational time and acceptable precision. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods

Estimates of radiation absorbed doses from radionuclides internally deposited in a pregnant woman and her fetus are very important due to elevated fetal radiosensitivity. This paper reports a set of specific absorbed fractions (SAFs) for use with the dosimetry schema developed by the Society of Nuclear Medicine's Medical Internal Radiation Dose (MIRD) Committee. The calculations were based on three newly constructed pregnant female anatomic models, called RPI-P3, RPI-P6, and RPI-P9, that represent adult females at 3-, 6-, and 9-month gestational periods, respectively. Advanced Boundary REPresentation (BREP) surface-geometry modeling methods were used to create anatomically realistic geometries and organ volumes that were carefully adjusted to agree with the latest ICRP reference values. A Monte Carlo user code, EGS4-VLSI, was used to simulate internal photon emitters ranging from 10 keV to 4 MeV. SAF values were calculated and compared with previous data derived from stylized models of simplified geometries and with a model of a 7.5-month pregnant female developed previously from partial-body CT images. The results show considerable differences between these models for low energy photons, but generally good agreement at higher energies. These differences are caused mainly by different organ shapes and positions. Other factors, such as the organ mass, the source-to-target-organ centroid distance, and the Monte Carlo code used in each study, played lesser roles in the observed differences in these. Since the SAF values reported in this study are based on models that are anatomically more realistic than previous models, these data are recommended for future applications as standard reference values in internal dosimetry involving pregnant females.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of the plasma profiles on photon and pair production in ultrahigh intensity laser solid interaction

The model of photon and pair production in strong field quantum electrodynamics is implemented into our 1D3V particle-in-cell code with Monte Carlo algorithm. Using this code, the evolution of the particles in ultrahigh intensity laser (∼10{sup 23} W/cm{sup 2}) interaction with aluminum foil target is observed. Four different initial plasma profiles are considered in the simulations. The effects of initial plasma profiles on photon and pair production, energy spectra, and energy evolution are analyzed. The results imply that one can set an optimal initial plasma profile to obtain the desired photon distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Neutron Shielding for the PICASSO Experiment

The PICASSO experiment searches WIMPs via their spin-dependent interactions with nuclei. At their operating temperatures, PICASSO threshold detectors are not sensitive to {gamma}-rays, while it is necessary to suppress neutron and {alpha}-ray backgrounds. The different types of neutron shielding (water, polyethylene, borated water and polyethylene doped with different compounds of boron and lithium) were studied via the Monte Carlo method using MCNPX code. Efficiencies of these different types of neutron shielding were compared from the point of view of neutron suppression as well as number of newly born y-rays. The neutrons and {gamma}-rays were followed up to the PICASSO detector active material. The most suitable neutron shielding for the PICASSO experiment was determined following these simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗