Orbital maneuvering vehicle guidance, navigation and control

This paper describes the Orbital Maneuvering Vehicle (OMV) concept and its intended role. It recaps the past activities leading up to the current concept and summarizes the present status and plans. The various types of missions and operating modes required by the OMV are described as the basis of the guidance, navigation and control (GN&C) requirements. The general GN&C problem is outlined with potential hardware solutions.

Huber, W. G.↗

A generalized theory for eccentric and misalignment effects in high-pressure annular seals

High-pressure annular seal leakage and dynamic coefficients vary with eccentricity and misalignment. Recent seal leakage data with both concentric and fully eccentric alignments support the seal leakage model with surface roughness and eccentricity effects included. In this paper, the seal dynamic coefficient calculation has been generalized and allows direct calculation of the seal dynamic coefficients at any circumferential location. The generalized solution agrees with the results obtained by using the calculated values of an earlier paper and performing a coordinate transformation. The analysis results coincide with the measured data in showing that the stiffness and damping matrices of seal coefficients are not skew symmetric, and the main diagonal seal coefficients are not equal. The measured direct stiffnesses were found higher than predicted by the concentric seal theory, but this may be explained by the presence of eccentricity in the test operating mode.

Chen, W. C.↗

The Space Telescope imaging spectrograph

Preliminary performance goals for the Space Telescope Imaging Spectrograph (STIS), selected by NASA for definition study as a second generation instrument on the Hubble Space Telescope (HST) are outlined. The STIS is a 2-dimensional spectrograph that will operate from 1050A-11000A at the limiting HST spatial resolution of 0.05 arcsec FWHM, with spectral resolutions of 100, 1200, 20,000, and 100,000 and a maximum field-of-view of 50X50 arcsec. Its basic operating modes include echelle mode (like IUE), long slit mode (for simultaneous spectra at 1000 positions on the target), slitless spectrograph mode, coronographic spectroscopy, photon time-tagging, and direct imaging.

Gull, Theodore R.↗

High heat transfer oxidizer heat exchanger design and analysis

The RL10-2B engine, a derivative of the RL10, is capable of multimode thrust operation. This engine operates at two low thrust levels: tank head idle (THI), which is approximately 1 to 2% of full thrust, and pumped idle (PI), which is 10% of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient engine thermal conditioning; PI operation provides vehicle tank pre-pressurization and maneuver thrust for low-g deployment. Stable combustion of the RL10-2B engine during the low thrust operating modes can be accomplished by using a heat exchanger to supply gaseous oxygen to the propellant injector. The oxidizer heat exchanger (OHE) vaporizes the liquid oxygen using hydrogen as the energy source. The design, concept verification testing and analysis for such a heat exchanger is discussed. The design presented uses a high efficiency compact core to vaporize the oxygen, and in the self-contained unit, attenuates any pressure and flow oscillations which result from unstable boiling in the core. This approach is referred to as the high heat transfer design. An alternative approach which prevents unstable boiling of the oxygen by limiting the heat transfer is referred to as the low heat transfer design and is reported in Pratt & Whitney report FR-19135-2.

Kmiec, Thomas D.↗

Control considerations for high frequency, resonant, power processing equipment used in large systems

Addressed is a class of resonant power processing equipment designed to be used in an integrated high frequency (20 KHz domain), utility power system for large, multi-user spacecraft and other aerospace vehicles. It describes a hardware approach, which has been the basis for parametric and physical data used to justify the selection of high frequency ac as the PMAD baseline for the space station. This paper is part of a larger effort undertaken by NASA and General Dynamics to be sure that all potential space station contractors and other aerospace power system designers understand and can comfortably use this technology, which is now widely used in the commercial sector. In this paper, we will examine control requirements, stability, and operational modes; and their hardware impacts from an integrated system point of view. The current space station PMAD system will provide the overall requirements model to develop an understanding of the performance of this type of system with regard to: (1) regulation; (2) power bus stability and voltage control; (3) source impedance; (4) transient response; (5) power factor effects, and (6) limits and overloads.

Mildice, J. W.↗

NASA star simulator

A star simulator is described which is capable of simulating a field of three or more stars in response to signals from a computer interface. Star magnitude and spectral output can be manipulated and absolute position measurements can be obtained with the system. The simulator is a single axis system which consists of two assemblies: a light source and filter wheel assembly, and a translation stage assembly. The assemblies are self contained on 60.96 x 60.96 cm breadboards and are connected via three fiber optic cables. A summary of operational modes is provided.

Source record↗

Radiometric calibration of the Shuttle Imaging Radar (SIR-C) system

The radiometric calibration accuracy of the Shuttle Imaging Radar (SIR-C) sensor is discussed. The analysis includes the antenna, RF electronics, the digital data handling system, the platform attitude control, attitude determination accuracy, and orbit effects. The radiometric distortion of the image products by the ground processing system used for the image formation is also considered. Since the SIR-C system is a dual-frequency quad-polarized system (i.e., 8 channels), the amplitude and phase error is considered over all possible operating modes and environments for absolute and relative (long-term and short-term) calibration within a channel and across channels.

Curlander, John C.↗

On the energy resolution obtained with a multistep proportional counter

Results of laboratory experiments with a standard multiwire imaging proportional counter (MWPC), modified to include a parallel grid preamplification stage are presented. Both argon and xenon were used as the primary absorbing gas in conjunction with a number of quench gases. It is found that extremely good energy resolution is obtained from the preamplification stage, almost independent of the ionization potential of the quench gas and over a broad range of gains. Furthermore, regardless of absorbing gas or quench agent, there was no difficulty in transferring a portion of this preamplified charge to the MWPC section for multistep mode operation. Finally, even for overall system gains greater than 10,000, the energy resolution from the second stage is found to be significantly improved, as long as the preamplification stage is operating. These results should have wide application and are of special interest for X-ray astronomy.

Ramsey, B. D.↗

Space Infrared Telescope Facility/Multimission Modular Spacecraft Attitude Control System conceptual design

A control system utilizing the Multi-mission Modular Spacecraft (MMS) Attitude Control System (ACS) was developed and analyzed for the Space Infrared Telescope Facility (SIRTF) spacecraft. Alternative torquer augmentation schemes were studied to determine viable ACS approaches. A control law was developed to use a dual set of single-axis Control Moment Gyros (CMGs) for two-axis control. Flexible structural models were developed using a high fidelity, flight tested NASTRAN model of the MMS, coupled with a NASTRAN model of the SIRTF telescope. Modal significance criteria were employed to reduce the structural model. Multivariable interactive techniques were used to synthesize the control system (including the structural filters). Control system performance for the SIRTF operational modes (quiescent inertial hold, slewing, nodding, and rastering) was then determined using both single-axis and three-axis simulations). The control system described met performance requirements for all modes but the raster with the use of CMGs. The raster performance was limited by the structural flexibility.

Class, Brian F.↗

GRO attitude control and determination

Design features of the attitude control and determination (ACAD) system for the Gamma Ray Observatory (GRO) that will eventually be launched on the Shuttle are described. A tabulation of the ACAD system components is provided and the various standby and normal pointing operational modes of the system are summarized. The system software and sensors will maintain a quaternion model of the GRO attitude on the bases of kinematic equations and inertial data. The software is standardized and has previously been used on the Solar Maximum Mission and Landsat-D. Details of the processing components, redundant electronics for sensor processing, data handling and actuator control are outlined and illustrated with block diagrams. Tests applied to validate the ACAD design are outlined, as are ground support which will be implemented once the GRO is launched.

Jerkovsky, W.↗

Use of the Orbital Maneuvering Vehicle (OMV) for placement and retrieval of spacecraft and platforms

This paper describes the Orbital Maneuvering Vehicle (OMV) and its intended role as a key element of NASA's space infrastructure. Status, plans, and operational modes are summarized. Typical mission scenarios supporting the servicing of spacecraft and platforms from both the Shuttle and the Space Station are described. Particular emphasis is placed on the orbital mechanics associated with the placement and retrieval of spacecraft and platforms. For example, the optimum placement of a Space Station co-orbiting spacecraft in order to maximize the time interval during which it can be retrieved by a Space Station based OMV is shown as a function of the ballistic coefficient of the spacecraft.

Snoddy, William C.↗

Second generation spectrograph for the Hubble Space Telescope

The preliminary design for the Space Telescope Imaging Spectrograph (STIS), which has been selected by NASA for definition study for future flight as a second-generation instrument on the Hubble Space Telescope (HST), is presented. STIS is a two-dimensional spectrograph that will operate from 1050 A to 11,000 A at the limiting HST resolution of 0.05 arcsec FWHM, with spectral resolutions of 100, 1200, 20,000, and 100,000 and a maximum field-of-view of 50 x 50 arcsec. Its basic operating modes include echelle model, long slit mode, slitless spectrograph mode, coronographic spectroscopy, photon time-tagging, and direct imaging. Research objectives are active galactic nuclei, the intergalactic medium, global properties of galaxies, the origin of stellar systems, stelalr spectral variability, and spectrographic mapping of solar system processes.

Woodgate, B. E.↗

An analysis of two classes of grazing incidence mirrors for use with Rowland circle spectrometers

Results are presented of a comparative analysis of Hettrick Bowyer Type II (HBII) and Wolter-Schwarzschild Type II (WSII) optics for use with Rowland circle spectrometers. The HBII can substitute, with few exceptions, for a WSII in any Rowland circle with little change in spectrometer performance or design. However, the HBII telescope offers several clear advantages over the WSII in these configurations. Because the HBII employs a virtual focus, it requires a much shorter instrument length than a WSII. For example, a 3-m Rowland circle spectrometer, fed by an optimized, f/10, 1-m diameter WSII, has a total instrument length of 6 m. If a HBII is used to feed the identical spectrometer, the entire instrument length can be as little as 3 m. In addition, the improved imaging gained with the larger graze angles of the HBII design results in better resolution in slitless operation modes.

Green, James↗

Adaptive Receiver For Coded Communications

Acquisition and tracking of signal controlled automatically. Receiver constructed in analog and digital portions so signal-processing functions performed economically by digital micro-processors. Principal feature is adaptive control algorithm that guides acquisition tracking and demodulation of signal providing for orderly transition through several sequences of operating modes.

Von Der Embse, U. A.↗

Computer simulation of a single pilot flying a modern high-performance helicopter

Presented is a computer simulation of a human response pilot model able to execute operational flight maneuvers and vehicle stabilization of a modern high-performance helicopter. Low-order, single-variable, human response mechanisms, integrated to form a multivariable pilot structure, provide a comprehensive operational control over the vehicle. Evaluations of the integrated pilot were performed by direct insertion into a nonlinear, total-force simulation environment provided by NASA Lewis. Comparisons between the integrated pilot structure and single-variable pilot mechanisms are presented. Static and dynamically alterable configurations of the pilot structure are introduced to simulate pilot activities during vehicle maneuvers. These configurations, in conjunction with higher level, decision-making processes, are considered for use where guidance and navigational procedures, operational mode transfers, and resource sharing are required.

Zipf, Mark E.↗

Control considerations for high frequency, resonant, power processing equipment used in large systems

Addressed is a class of resonant power processing equipment designed to be used in an integrated high frequency (20 KHz domain), utility power system for large, multi-user spacecraft and other aerospace vehicles. It describes a hardware approach, which has been the basis for parametric and physical data used to justify the selection of high frequency ac as the PMAD baseline for the space station. This paper is part of a larger effort undertaken by NASA and General Dynamics to be sure that all potential space station contractors and other aerospace power system designers understand and can comfortably use this technology, which is now widely used in the commercial sector. In this paper, we will examine control requirements, stability, and operational modes; and their hardware impacts from an integrated system point of view. The current space station PMAD system will provide the overall requirements model to develop an understanding of the performance of this type of system with regard to: (1) regulation; (2) power bus stability and voltage control; (3) source impedance; (4) transient response; (5) power factor effects; and (6) limits and overloads.

Mildice, J. W.↗

An overview of the Hubble Space Telescope command and data management system

The Hubble Space Telescope (HST) will be an orbiting observatory which will extend the capability of large earth-based observatories to view the universe by approximately 350 times in volume and approximately seven times in distance. The HST program, which includes the Orbiting Observatory, the Space Telescope Science Institute, and the Space Telescope Operations Control Center, is supported by the Space Shuttle, the Tracking and Data Relay Satellite System, and the NASA Communications Network. This paper describes the Command and Data Management System for the HST spacecraft, including flexibility, operation modes, and end-to-end data flow paths used to meet stringent synchronization and data quality requirements. The results of system tests indicate that the use of concatenated coding techiques consisting of both block and convolutional codes as a protection against random and burst errors has been successful. Diagrams of the HST data system are included.

Clubb, Jerry↗

GaAs/GaAlAs distributed Bragg reflector laser with a focused ion beam, low dose dopant implanted grating

The performance of a GaAs/GaAlAs distributed Bragg reflector (DBR) laser using a focused ion beam implanted grating (FIB-DBR) is reported for the first time. Stripes of Si(2+) with a period of 2300 A and a dose about 10 to the 14th/sq cm are directly implanted into the passive large optical cavity layer to provide the distributed feedback. Surface-emitting light from the second-order grating is observed. Threshold current of 110 mA and single DBR mode operation from 20 to 40 C are obtained. The wavelength tuning rate with temperature is 0.8 A/C. The coupling coefficient is estimated to be 15/cm. The results show that FIB technology is practical for distributed feedback and DBR lasers and optoelectronic integrated circuits.

Wu, M. C.↗