Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Australian Solar Energy Forecasting System (ASEFS) (CRADA CRD-14-541 Final Report)

This project forms a part of the broader project with the same name which is funded by ASI under the US-Australia Solar Energy Collaboration (Broader Project). The Broader Project involves a number of other participants, being the University of New South Wales, the University of South Australia, the Australian Energy Market Operator Limited and the Commonwealth of Australia acting through the Bureau of Meteorology (Other Participants). NREL and CSIRO will each work with the Other Participants in the performance of this CRADA. However, for the avoidance of doubt, this CRADA does not cover the whole of the Broader Project and only relates to the work described in this Joint Work Statement, which is to be carried out by NREL. In the course of this project, NREL may be provided with materials belonging to CSIRO or the Other Participants, which it may use solely for the purpose of performing the project described in this Joint Work Statement. Similarly, CSIRO may provide NREL project materials to Other Participants pursuant to Article IX or XV of the CRADA, for the purpose of performing research forming part of the Broader Project in collaboration with CSIRO.

14 SOLAR ENERGY↗

Risk Considerations of Transitioning CO2-EOR Field to CO2 storage Field: Case Study

In the United States (U.S.), carbon dioxide (CO2) injection wells at EOR sites are currently regulated as Class II wells under the U.S. Environmental Protection Agency’s (EPA) Underground Injection Control (UIC) program while dedicated geological CO2 storage (GCS) wells are considered Class VI wells. A CO2-EOR facility considering a transitioning from tertiary oil recovery to injecting CO2 for the primary purpose of long-term storage is required to obtain a Class VI permit where this transition poses an increased risk to underground sources of drinking water. This study considers how transitioning operations from CO2-EOR to storage can impact reservoir plume and pressure transient in the storage envelope, and how these changes could impact area of review and potential unwanted fluid migration. We developed a case study to assess subsurface response and leakage risks associated with a representative, hypothetical operation in a carbonate reservoir. This reservoir transitions from tertiary hydrocarbon recovery to dedicated GCS. Reservoir simulations were run for a set of credible CO2-EOR scenarios to estimate distributions of fluids phases and pressures throughout the model domain after CO2 flooding as well as forecasting the behavior of the reservoir after the transition to a dedicated storage phase. The evolutions from all simulated scenarios were used as the basis for leakage risk quantification using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM) with a novel reduced-order model to estimate time-dependent leakage of CO2, brine, and hydrocarbon fluids through potentially leaky wells. Results include a description of reservoir response, an estimate of the areal extent that could potentially be impacted by leakage to underground sources of drinking water, and estimates of the magnitude of potential leakage. Considerations for dedicated storage injection well selection, injectivity, and injection scheme performance and potential leakage risk are presented, with implications for risk assessment of well transition discussed. This study presents a risk-based workflow for the Class II to Class VI well transition. Integrating credible numerical simulation of viable CO2-EOR to dedicated CO2 storage with quantitative risk assessment tools, such as the NRAP-Open-IAM, will provide a valuable means to devise operational scenarios and inform decision-making related to storage benefit, leakage risk, and liability. Presented at the SPE/AAPG/SEG Carbon Capture Utilization and Storage Conference in Houston, TX, March 11-13, 2024.

Liu, Guoxiang↗

Evaluation of Atmospheric Conditions Leading to a Fumigation Event

During the afternoon of 30 January 2022, the Savannah River Site experienced unusual temperature conditions leading to a fumigation event that triggered safety alarms and caused considerable confusion about the cause of the event. Normally, it is assumed that fumigation events occur early in the day once surface heating has begun. While most fumigation events are related to the breakup of a nocturnal inversion, this event was related to synoptic atmospheric conditions, which provided a more unique scenario that led to the fumigation event. The unusual synoptic atmospheric conditions led to the downwash and fumigation of the elevated plume, causing a pollutant to mix rapidly to the surface. These conditions could have potentially harmed workers within the facility, since the plume was directed toward a building air intake system. Here, we seek to outline the conditions that led to this unusual fumigation event and provide results of two-dimensional (2D) wind modeling of the event to characterize these conditions for future operational guidance of the facility air intake systems. This work sets the groundwork for future high-resolution modeling to explore the mechanisms and thresholds affecting fumigation on the facility-specific short distance scales and improve forecasting of non-standard fumigation events to protect human health.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Incorporating Forecast Uncertainty in Utility Control Center

Uncertainties in forecasting the output of intermittent resources such as wind and solar generation, as well as system loads are not adequately reflected in existing industry-grade tools used for transmission system management, generation commitment, dispatch and market operation. There are other sources of uncertainty such as uninstructed deviations of conventional generators from their dispatch set points, generator forced outages and failures to start up, load drops, losses of major transmission facilities and frequency variation. These uncertainties can cause deviations from the system balance, which sometimes require inefficient and costly last minute solutions in the near real-time timeframe. This Chapter considers sources of uncertainty and variability, overall system uncertainty model, a possible plan for transition from deterministic to probabilistic methods in planning and operations, and two examples of uncertainty-based fools for grid operations.This chapter is based on work conducted at the Pacific Northwest National Laboratory (PNNL)

wind generation, solar generation, Energy managmen↗

Probabilistic Swinging Door Algorithm as Applied to Photovoltaic Power Ramping Event Detection

Photovoltaic (PV) power generation experiences power ramping events due to cloud interference. Depending on the extent of PV aggregation and local grid features, such power variability can be constructive or destructive to measures of uncertainty regarding renewable power generation; however, it directly influences contingency planning, production costs, and the overall reliable operation of power systems. For enhanced power system flexibility, and to help mitigate the negative impacts of power ramping, it is desirable to analyze events in a probabilistic fashion so degrees of beliefs concerning system states and forecastability are better captured and uncertainty is explicitly quantified. A probabilistic swinging door algorithm is developed and presented in this paper. It is then applied to a solar data set of PV power generation. The probabilistic swinging door algorithm builds on results from the original swinging door algorithm, first used for data compression in trend logging, and it is described by two uncertain parameters: (i) e, the threshold sensitivity to a given ramp, and (ii) s, the residual of the piecewise linear ramps. These two parameters determine the distribution of ramps and capture the uncertainty in PV power generation.

14 SOLAR ENERGY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accurate and Timely Forecasts of Geologic Carbon Storage using Machine Learning Methods

Carbon capture and storage is one strategy to reduce greenhouse gas emissions. One approach to storing the captured CO2 is to inject it into deep saline aquifers. However, dynamics of the injected CO2 plume is uncertain and the potential for leakage back to the atmosphere must be assessed. Thus, accurate and timely forecasts of CO2 storage via real-time measurements integration becomes very crucial. This study proposes a learning-based, inverse-free prediction method that can accurately and rapidly forecast CO2 movement and distribution with uncertainty quantification based on limited simulation and observation data. The machine learning techniques include dimension reduction, multivariate data analysis, and Bayesian learning. The outcome is expected to provide CO2 storage site operators with an effective tool for real-time decision making.

Lu, Dan↗

Low and intermediate level short lived waste disposal in France: improving confidence - 15254

Thanks to the significant reduction of waste production and according to forecasts derived from the French National Inventory of Radioactive Materials and Waste issued by Andra, Centre de l'Aube disposal facility should be able to accommodate low and intermediate level short lived waste generated by all presently operated or decided nuclear facilities in France. The facility could then be operated till 2050-2060. Andra has to maintain the facility up to date and to adapt it to meet waste generators needs, in particular needs related to decommissioning works. Its safety is assessed by periodical safety review and confirmed by an environmental monitoring program. Safety also relies on an acceptance process that takes benefit from 20 years of experience and must now be adapted to the management of decommissioning waste. Confidence by local communities is maintained through a permanent dialogue. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Temporally-consistent koopman autoencoders for forecasting dynamical systems

Absence of sufficiently high-quality data often poses a key challenge in data-driven modeling of high-dimensional spatio-temporal dynamical systems. Koopman Autoencoders (KAEs) harness the expressivity of deep neural networks (DNNs), the dimension reduction capabilities of autoencoders, and the spectral properties of the Koopman operator to learn a reduced-order feature space with simpler, linear dynamics. However, the effectiveness of KAEs is hindered by limited and noisy training datasets, leading to poor generalizability. To address this, we introduce the Temporally-Consistent Koopman Autoencoder (tcKAE), designed to generate accurate long-term predictions even with limited and noisy training data. This is achieved through a consistency regularization term that enforces prediction coherence across different time steps, thus enhancing the robustness and generalizability of tcKAE over existing models. We provide analytical justification for this approach based on Koopman spectral theory and empirically demonstrate tcKAE’s superior performance over state-of-the-art KAE models across a variety of test cases, including simple pendulum oscillations, kinetic plasma, and fluid flow data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

A test of the millisecond magnetar central engine model of gamma-ray bursts with swift data

A rapidly spinning, strongly magnetized neutron star (magnetar) has been proposed as one possible candidate of the central engine of gamma-ray bursts (GRBs). We systematically analyze the Swift/XRT light curves of long GRBs detected before 2013 August, and characterize them into four categories based on how likely they may harbor a magnetar central engine: Gold, Silver, Aluminum, and Non-magnetar. We also independently analyze the data of short GRBs with a putative magnetar central engine. We then perform a statistical study of various properties of the magnetar samples and the non-magnetar sample, and investigate whether the data are consistent with the hypothesis that there exist two types of central engines. By deriving the physical parameters of the putative magnetars, we find that the observations of the Gold and Silver samples are generally consistent with the predictions of the magnetar model. For a reasonable beaming factor for long GRBs, the derived magnetar surface magnetic field B{sub p} and initial spin period P {sub 0} fall into the reasonable range. Magnetar winds in short GRBs, on the other hand, are consistent with being isotropic. No GRB in the magnetar sample has a beam-corrected total energy exceeding the maximum energy budget defined by the initial spin energy of the magnetar, while some non-magnetar GRBs do violate such a limit. With beaming correction, on average the non-magnetar sample is more energetic and luminous than the magnetar samples. Our analysis hints that millisecond magnetars are likely operating in a good fraction, but probably not all, GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

SRNL Atmospheric Technologies Group

The Savannah River National Laboratory, Atmospheric Technologies Group, conducts a best-in class Applied Meteorology Program to ensure the Department of Energy’s Savannah River Site is operated safely and complies with stringent environmental regulations.

47 OTHER INSTRUMENTATION↗

A path to intelligent watersheds: coordinating the data to decision pipeline

Operations of multi-reservoir systems are challenged in-part by the interplay of complex physical processes functioning within the watershed. The employment of intelligent systems can be of aid by linking environmental sensing, information technology, data analytics, simulation and decision support to achieve a data-to-decision flow of information. A further challenge is that watershed resources are managed for multiple purposes requiring some level of coordination among numerous resource managers, asset operators and users. System intelligence in this context relies on shared community platforms (data portals, community models), and coordinated communication between decision makers. Opportunities to enrich watershed intelligence has been the subject of a roadmapping exercise for the Department of Energy’s Water Power Technologies Office which has relied on broad stakeholder engagement. Initial phases of engagement involved personal interviews and a series of virtual group meetings, which focused on identifying opportunities to improve the intelligence of the physical infrastructure within our watersheds—examples of feedback include improved sensing of snowpack and runoff, data standards for facilitated data sharing, and better forecasting tools. The latter phase of engagement involved the conduct of a case study in the Upper Colorado River basin where key stakeholders were interviewed to map how their decisions are informed by intelligence from other basin stakeholders. Our presentation will highlight the interdisciplinary flow of information in complex watershed systems and identify physical and institutional opportunities toward the strategic operation of water infrastructure.

Colorado River↗

Using concentrating-solar-power plants as economic carbon-free capacity resources

Deep decarbonization of electricity systems raises concerns about the need for generating capacity that can maintain reliable energy supply. Given this concern, we explore the ability of concentrating-solar-power plants with thermal energy storage to provide a carbon-free source of such capacity. We develop an approach to assessing the capacity contribution of concentrating-solar-power plants that considers future systems. Such considerations are important, because of potential differences in net-load patterns compared to today (e.g., due to higher renewable-energy penetrations). Using historical data spanning an 18-year period, we demonstrate that concentrating-solar-power plants with thermal energy storage can provide this necessary capacity with little impact on their financial viability. We examine the impact of myopic decisions and imperfect foresight of future system conditions on the operation of concentrating-solar-power plants and the resultant impact on their capacity contributions. We find that imperfect foresight can have limited impacts on such a use of concentrating-solar-power plants, so long as proper forecasting techniques are developed and used. Overall, our work shows that concentrating-solar-power plants with thermal energy storage may have a role to play in delivering reliable electricity supply in a decarbonized energy system.

14 SOLAR ENERGY↗

Autonomous Anomaly Detection for MPC Forecasts of HVAC Systems in Residential Communities

The use of residential heating, ventilation, and air conditioning (HVAC) to shift peak demand or provide ancillary services is a potential solution in the presence of older grids and distributed renewables. However, to ensure the efficient use of devices, utilities need to accurately forecast the load and adopt error correction schemes when necessary. While significant theoretical research exists in the area of predictive control of HVAC, little experimental evidence exists. The lack of experimental data in turn causes researchers to be unprepared for unsystematic errors which emerge due to the higher complexity of the data generating process. This study offers an anomaly detection methodology that uses unsupervised machine learning algorithms to detect and isolate these errors with different forecast error ranges. The results of anomaly detection procedure can then be used for error correction and would eventually help develop better predictive controllers. The methodology is tested using real world data from a smart neighborhood that currently operates in Atlanta. GA.

Lebakula, Viswadeep↗