Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Active Array Measurements using the Portable Laser Guided Robotic Metrology System

In this paper, we will discuss the impact of mounting structures on the installed performance of phased arrays. In particular, performance data for the Conformal, Lightweight Antennas for Aeronautical Communications Technology (CLAS-ACT) antenna will be presented. Performance data from a series of mounting configurations will show that null depth and location is particularly susceptible to change while the main beam steering angle remains relatively stable. In addition, the Portable Laser Guided Robotic Metrology (PLGRM) system will be discussed as a suitable instrument for measuring antenna patterns in complex or difficult locations that are challenging for traditional ranges. The PLGRM system was recently developed at the National Aeronautics and Space Administration's (NASA) Glenn Research Center (GRC) and deployed to measure in situ antenna patterns.

Piasecki, Marie↗

A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

Helms, W. R.↗

MCNP Simulation of Discrete Gamma-ray Spectra for PGNAA Applications

Prompt Gamma Neutron Activation (PGNAA) systems use the neutron-induced gamma-ray spectra from test objects in order to identify their compositions. The U.S. Army in particular uses these systems to identify the contents of field-recovered munitions in order to determine the presence of chemical warfare materiel (CWM) or explosives. These field-recovered munitions can have a variety of different fills, including experimental fills, have a large range of sizes, and be assessed in different field conditions. All these variations can have a significant effect on the neutron-induced gamma-ray spectrum and therefore a large impact on automatic fill identification algorithms. In order to develop robust identification algorithms, parametric studies of the effects of munition size, fill composition, and assessment conditions are very useful but time-consuming and expensive in the laboratory. Monte Carlo modeling of the system response to these variations is a very attractive alternative, provided the modeling accurately reflects real gamma spectra and can be performed quickly and inexpensively when compared to experiment. At Idaho National Laboratory we have used the Monte Carlo N-Particle (MCNP6) code [2] to calculate the response of the Portable Isotopic Neutron Spectroscopy (PINS) system to a number of simulated chemical warfare munitions as well as performed laboratory measurements with the system. Two versions of PINS system were used; one excited the test object with neutrons from a 252C f source and one with neutrons from a portable deuterium-deuterium (DD) neutron generator. The sets of measurements and simulations with the two different neutron sources provided experimental data for development of automatic fill identification algorithms as well as providing a good test of the agreement between the MCNP calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Porting Adaptive Ensemble Molecular Dynamics Workflows to the Summit Supercomputer

Molecular dynamics (MD) simulations must take very small (femtosecond) integration steps in simulation-time to avoid numerical errors. Efficient use of parallel programming models and accelerators in state-of-the art MD programs now is pushing Moore’s limit for time-per-MD step. As a result, directly simulating timescales beyond milliseconds will not be attainable directly, even at exascale. However, concepts from statistical physics can be used to combine many parallel simulations to provide information about longer timescales and to adequately sample the simulation space, while preserving details about the dynamics of the system. Implementing such an approach requires a workflow program that allows adaptable steering of task assignments based on extensive statistical analysis of intermediate results. Here we report the implementation of such an adaptable workflow program to drive simulations on the Summit IBM Power System AC922, a pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). We compare to experiences on Titan, Summit’s predecessor, report the performance of the workflow and its components, and describe the porting process. We find that using a workflow program managed by a Mongo database can provide the fault tolerance, scalable performance, task dispatch rate, and reconfigurability required for robust and portable implementation of ensemble simulations such as are used in enhanced-sampling molecular dynamics. This type of workflow generator can also be used to provide adaptive steering of ensemble simulations for other applications in addition to MD.

Ossyra, John R.↗

Directionality in the GammaTracker Handheld Radioisotope Identifier

Several computationally simple methods are presented for determining the direction to one or more point sources using the GammaTracker handheld radioisotope identifier. GammaTracker will display a heading indicating the direction to one or more sources; no gamma-ray images will be displayed to the user. The details of each directionality method are presented and performance is compared using radiation transport simulations of gamma-ray point sources at varying activity levels on a natural background. All methods achieved sufficiently high pointing accuracy and precision in the tested scenarios, which included background-to-source ratios up to 10:1. The prospects for implementation in the GammaTracker firmware architecture are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-performance subambient radiative cooling enabled by optically selective and thermally insulating polyethylene aerogel

Recent progress in passive radiative cooling technologies has substantially improved cooling performance under direct sunlight. Yet, experimental demonstrations of daytime radiative cooling still severely underperform in comparison with the theoretical potential due to considerable solar absorption and poor thermal insulation at the emitter. In this work, we developed polyethylene aerogel (PEA)—a solar-reflecting (92.2% solar weighted reflectance at 6 mm thick), infrared-transparent (79.9% transmittance between 8 and 13 μm at 6 mm thick), and low-thermal-conductivity ( k PEA = 28 mW/mK) material that can be integrated with existing emitters to address these challenges. Using an experimental setup that includes the custom-fabricated PEA, we demonstrate a daytime ambient temperature cooling power of 96 W/m 2 and passive cooling up to 13°C below ambient temperature around solar noon. This work could greatly improve the performance of existing passive radiative coolers for air conditioning and portable refrigeration applications.

36 MATERIALS SCIENCE↗

The Benefits and Weaknesses of Containerizing Software for HPC

Containerization technology has emerged as a transformative tool for software engineers, offering consistent development and deployment environments, simplifying dependency management, and enhancing scalability and portability across diverse systems. However, its application in High-Performance Computing (HPC) presents unique challenges, including the management of virtualization overhead, the need for efficient resource allocation, and the maintenance of optimal performance for compute-intensiv

Ho, Eric Victor [Sandia National Laboratories (SNL↗

Linear-Algebra Programs

The Basic Linear Algebra Subprograms (BLAS) library is a collection of 38 FORTRAN-callable routines for performing basic operations of numerical linear algebra. BLAS library is portable and efficient source of basic operations for designers of programs involving linear algebriac computations. BLAS library is supplied in portable FORTRAN and Assembler code versions for IBM 370, UNIVAC 1100 and CDC 6000 series computers.

Lawson, C. L.↗

Fluctuation analysis of relativistic nucleus-nucleus collisions in emulsion chambers

An analytical technique was developed for identifying enhanced fluctuations in the angular distributions of secondary particles produced from relativistic nucleus-nucleus collisions. The method is applied under the assumption that the masses of the produced particles are small compared to their linear momenta. The importance of particles rests in the fact that enhanced fluctuations in the rapidity distributions is considered to be an experimental signal for the creation of the quark-gluon-plasma (QGP), a state of nuclear matter predicted from the quantum chromodynamics theory (QCD). In the approach, Monte Carlo simulations are employed that make use of a portable random member generator that allow the calculations to be performed on a desk-top computer. The method is illustrated with data taken from high altitude emulsion exposures and is immediately applicable to similar data from accelerator-based emulsion exposures.

Mcguire, Stephen C.↗

The effect of optokinetic stimulation on daytime sleepiness

This study examined the effect of optokinetic stimulation on objective sleepiness, as measured by the Multiple Sleep Latency Test (MSLT). The Nightcap, a portable sleep monitor, was used in a novel way to perform MSLTs, as well as record sleep in the home. Subjects wore the Nightcap for seven consecutive nights. On days 3 and 5 of the protocol, subjects came into the lab for an MSLT. On the experimental day, subjects underwent 10 minutes optokinetic stimulation (OKS), resulting in moderate motion sickness prior to each MSLT trial. Although subjects in the OKS condition reported significantly more drowsiness than controls, this did not result in significantly reduced sleep latencies.

NASA Discipline Neuroscience↗

Transient Modeling and Analysis of a Metabolic Heat-Regenerated Temperature Swing Adsorption (MTSA) System for a PLSS

A Metabolic heat-regenerated Temperature Swing Adsorption (MTSA) system is being developed for carbon dioxide, water and thermal control in a lunar and martian portable life support system (PLSS). A previous system analysis was performed to evaluate the impact of MTSA on PLSS design. That effort was Mars specific and assumed liquid carbon dioxide (LCO2) coolant made from martian resources. Transient effects were not considered but rather average conditions were used throughout the analysis. This effort takes into further consideration the transient effects inherent in the cycling MTSA system as well as assesses the use of water as coolant. Standard heat transfer, thermodynamic, and heat exchanger methods are presented to conduct the analysis. Assumptions and model verification are discussed. The tool was used to perform various system studies. Coolant selection was explored and takes into account different operational scenarios as the minimum bed temperature is driven by the sublimation temperature of the coolant (water being significantly higher than LCO2). From this, coolant mass is sized coupled with sorbent bed mass because MTSA adsorption performance decreases with increasing sublimation temperature. Reduction in heat exchanger performance and even removal of certain heat exchangers, like a recuperative one between the two sorbent beds, is also investigated. Finally, the coolant flow rate is varied over the cycle to determine if there is a more optimal means of cooling the bed from a mass perspective. Results of these studies and subsequent recommendations for system design are presented.

Iacomini, Christie↗

Field Characterization of the Mineralogy and Organic Chemistry of Carbonates from the 2010 Arctic Mars Analog Svalbard Expedition by Evolved Gas Analysis

The 2010 Arctic Mars Analog Svalbard Expedition (AMASE) investigated two geologic settings using methodologies and techniques being developed or considered for future Mars missions, such as the Mars Science Laboratory (MSL), ExoMars, and Mars Sample Return. The Sample Analysis at Mars (SAM) [1] instrument suite, which will be on MSL, consists of a quadrupole mass spectrometer (QMS), a gas chromatograph (GC), and a tunable laser mass spectrometer (TLS); all will be applied to analyze gases created by pyrolysis of samples. During AMASE, a Hiden Evolved Gas Analysis-Mass Spectrometer (EGA-MS) system represented the EGA-MS capability of SAM. Another MSL instrument, CheMin, will use x-ray diffraction (XRD) and x-ray fluorescence (XRF) to perform quantitative mineralogical characterization of samples [e.g., 2]. Field-portable versions of CheMin were used during AMASE. AMASE 2010 focused on two sites that represented biotic and abiotic analogs. The abiotic site was the basaltic Sigurdfjell vent complex, which contains Mars-analog carbonate cements including carbonate globules which are excellent analogs for the globules in the ALH84001 martian meteorite [e.g., 3, 4]. The biotic site was the Knorringfjell fossil methane seep, which featured carbonates precipitated in a methane-supported chemosynthetic community [5]. This contribution focuses on EGA-MS analyses of samples from each site, with mineralogy comparisons to CheMin team results. The results give insight into organic content and organic-mineral associations, as well as some constraints on the minerals present.

McAdam, A. C.↗

Progress in Materials and Component Development for Advanced Lithium-ion Cells for NASA's Exploration Missions

Vehicles and stand-alone power systems that enable the next generation of human missions to the Moon will require energy storage systems that are safer, lighter, and more compact than current state-of-the- art (SOA) aerospace quality lithium-ion (Li-ion) batteries. NASA is developing advanced Li-ion cells to enable or enhance the power systems for the Altair Lunar Lander, Extravehicular Activities spacesuit, and rovers and portable utility pallets for Lunar Surface Systems. Advanced, high-performing materials are required to provide component-level performance that can offer the required gains at the integrated cell level. Although there is still a significant amount of work yet to be done, the present state of development activities has resulted in the synthesis of promising materials that approach the ultimate performance goals. This report on interim progress of the development efforts will elaborate on the challenges of the development activities, proposed strategies to overcome technical issues, and present performance of materials and cell components.

Reid, Concha, M.↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

DQE of wireless digital detectors: Comparative performance with differing filtration schemes

Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X{sub N}/2, X{sub N}, and 2X{sub N}, where the normal exposure level to the detector surface (X{sub N}) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different detectors with the added convenience of being less bulky for in-the-field measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Nonuniform Reduction in HIP and SYCL on GPUs

Motivated by maturing programming models and portability for heterogeneous computing, we describe the challenges posed by hardware architectures and programming models when migrating an optimized implementation of nonuniform reduction from CUDA to HIP and SYCL. We explain the migration experience, evaluate the performance of the reduction on GPU -based computing platforms, and provide feedback on improving portability for the development of the SYCL programming model.

Jin, Zheming↗