Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO{sub 2} interaction are also presented. Then, in a second part, a functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radon Fluxes from an Earthen Barrier Over Uranium Mill Tailings After Two Decades of Service - 17234

Radon (Rn) fluxes were measured at a disposal facility for uranium mill tailings after two decades of service. The facility was closed with an earthen cover vegetated with grasses. Measurements were made on the surface of the Rn barrier and directly on the surface of the tailings. Fluxes were measured using extra small (area = 0.018 m{sup 2}), small (0.071 m{sup 2}), medium (0.59 m{sup 2}), and large (2.32 m{sup 2}) flux chambers to evaluate the impact of measurement scale on Rn flux. Activated carbon (AC) passive collectors and electric radon detectors (RAD7) were used to measure Rn concentrations. Tests were conducted at various locations on each cover representing conditions that can lead to different levels of soil structural development and different water content. Rn fluxes at the surface of the Rn barrier were much lower than Rn fluxes measured at the surface of the tailings, indicating the barrier remained effective for Rn containment. Geometric mean Rn fluxes measured at the surface of the Rn barrier in each test pit were below the regulatory requirement (0.74 Bq/m{sup 2}- s). Rn concentrations measured using AC samplers in the flux chambers were 60% of concentrations measured using the RAD7, on average, and Rn fluxes computed with the AC data were 9% of those computed with the RAD7 data, on average. Size of the flux chamber had no systematic effect on Rn flux, indicating that 20 y of soil forming processes had not created a pore network causing scale-dependent Rn flux. Geometric mean Rn fluxes in the test pits were similar regardless of differences in surface conditions (vegetation, thickness of soil cover) known to influence soil forming processes and soil structure, but were lower in areas where surface conditions promoted higher water content in the Rn barrier. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation of Simulated HLW Glass and International Simple Glass immersed partially in water - 16474

Water degradation of glass waste forms destined for geological disposal has been studied in a variety of conditions including of bulk glass immersed completely in static or dynamic water. During the course of repository life, the canisters may be only partially immersed in the initial stages of contact with water. Under these conditions glass degradation occurs on the glass immersed in water and on the glass above water by vapor condensation. In this work degradation of International Simple Glass (ISG) and Simulated High Level Waste Glass (HSG) is examined by immersing partially in distilled water during the course of test. Under static experimental conditions at 90 deg. C, the condensation of vapor on the ISG glass surface formed Ca-rich precipitates and pits after degrading for 1 and 3 weeks respectively. Whereas HSG precipitated Ca-rich phases predominantly after 1 week and no pits were found on the surface. When compared, HSG was found to change surface chemistry faster than ISG. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Development of Legacy Waste Scaling Factors for Radioactively Contaminated Soils at Chalk River Laboratories - 19333

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Beginning in 1952 after the NRX accident, the management of excess contaminated liquids from the accident, and later in 1953, other waste liquids, were intermittently dispersed to trenches and pits in the local sand. The local sands proved effective at immobilization of actinides, and most activation and fission products. However there was very limited retention of some more commonly mobile radionuclides. Sand filtration performance and radionuclide migration was studied beginning in 1952. Monitoring data indicated slow migration of most radioactive contaminants away from the trenches and pits due to the adsorbing capacity of the sand substrate. The radionuclide migration continues to be studied today in frequent plume monitoring studies. Because many hard-to measure (HTM) radionuclides may also present as long term dose contributors in post remediation scenarios, or in disposal site performance assessments, the quantification of these HTM radionuclides is important. The use of scaling factors between HTM radionuclides and easy-to-measure (ETM) radionuclides (gamma emitters) for packaged soil wastes would alleviate significant effort in sampling individual waste containers. As part of plume monitoring studies and the environmental remediation process, significant characterization of soils have been performed at the site. The soil sample data from multiple historic waste management areas across site is combined and relationships between HTM radionuclides and ETM or key radionuclides are examined. Additional (secondary) relationships between ETM key nuclides are also explored to evaluate secondary scaling relationships between ETM key radionuclides (e.g., Co- 60/Cs-137), because of the significant decay of the activation product key radionuclide Co-60, (predominantly 10-20 half-lives). The evaluation is yielding consistent scaling factors for legacy soil wastes in the historic waste management areas. Given the hydrogeology of the site, a sandy shallow unconfined aquifer, and the annual precipitation of about 0.85 m/a, this evaluation reveals some expected relationships between fission products and actinides and some unanticipated relationships between more mobile radionuclides and key gamma emitters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inspection of Dry Storage Casks Using PGAA and NAA Techniques

In this effort, an assessment of a chloride detection method is performed for inspecting the surfaces of dry cask storage system (DCSS) canisters, with focus on the implementation of a non-destructive nuclear analysis and methodology. Some DCSS canisters (especially those located in coastal environments) will be exposed to marine environments, which can cause atmospheric stress corrosion cracking (SCC). Chloride deposits on canister surfaces provide the corrosive environment necessary for atmospheric SCC with the residual stresses and materials properties conditions. The most susceptible regions on the canister surface are the weld areas, or where cold work has been performed, and may provide the necessary driving force for crack growth. The heat-affected zones (HAZs) near welds are also potentially susceptible to atmospheric SCC due to sensitization of the material caused by chromium depletion during the welding process. Information collected from the field and from laboratory studies has not been able to rule out the possibility of atmospheric chloride induced stress corrosion cracking (CISCC), although no occurrences of atmospheric SCC in DCSS canisters have been detected to-date. A number of researchers have demonstrated that localized corrosion can take place under such situations on materials commonly used for interim storage containers, including 304SS (Cook et al. 2010; Shirai et al. 2011) and 316SS (Tani et al. 2009). In this summary, the preliminary results of a neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA) are performed using MCNP6, a highly sophisticated, multi-particle Monte Carlo simulation code (with the employment of the high performance computing system at the Idaho National Laboratory), and confirm the feasibility of using PGAA and NAA as an environmental inspection methodology for detection and monitoring of small quantities of chlorine on canister surfaces. The specific signature of gamma rays due reactions of sea salt constituents are documented and summarized in this paper. The environmental constituent for passive oxide film breaching is chlorine, which can cause pitting initiation and incubation time that may lead to cracking in stainless steel. Therefore, an assessment of chloride presence at a canister surface is essential before moving to other nondestructive analysis (NDA) methods for detection of pitting and cracking. Two nonlinear acoustic techniques will also be used in our integrated research project (IRP) research study that proves to be useful in the detection of SCC: nonlinear resonant ultrasound spectroscopy (NRUS), and time revisited elastic nonlinear diagnostic (TREND). These two techniques are complementary to marine atmospheric detection techniques. In this presentation only PGAA and NAA are described in detail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Liquid radioactive waste has been stored in large, underground carbon steel tanks of 4.92-million-liter capacity at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina since the 1950s. The In-service inspection of the Savannah River Site High Level Waste tanks will be reviewed as well as Ultrasonic testing (UT) for detecting for general wall thinning, pitting and interface attack through accessible regions of the tanks. In-service inspection [1] of the Savannah River Site (SRS) High Level Waste (HLW) tanks is an essential element of a comprehensive structural integrity program. Inspection confirmed the effectiveness of chemistry and temperature controls used to preclude localized and general corrosion of the tanks. Ultrasonic testing is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of a 21.59 cm (8.5-in.) wide strip extending over the accessible height of the primary tank wall.

Harris, Stephen P.↗

Study on Electropolishing of N-Doped Niobium Surfaces and 650 MHz Cavity for High-Gradient Performance

This presentation provides an overview of the latest studies on electropolishing (EP) of nitrogen-doped niobium surfaces and 650 MHz cavities. The first study focuses on optimizing EP parameters to achieve a pit-free surface on N-doped niobium, highlighting the effects of process conditions on surface pitting and suggesting strategies for mitigation. The second study investigates the EP of 650 MHz cavities to achieve high-gradient performance comparable to that of 1.3 GHz niobium SRF cavities. Additionally, an example of a 650 MHz single-cell cavity is presented, demonstrating its record-high gradient achieved through optimized EP conditions.

43 PARTICLE ACCELERATORS↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

IEEE SusTech 2025 Presentation

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6\% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

42 - ENGINEERING↗

Surface heterogeneity propagation and homogenization for pouch cell-scale Li metal anodes

Li metal anode is a promising candidate for next-generation energy storage systems and is widely explored in Li-ion and solid-state batteries. Despite its potential, Li metal anodes face instabilities during long-term cycling, especially when paired with NMC or sulfur-based cathodes, where Li is cycled at high capacities of 6-8 mAh/cm2, equivalent to a thickness of 30-40 µm. During such extensive utilization, degradation mechanisms such as excessive solid electrolyte interphase (SEI), dendrites, and dead Li emerge, and ultimately lead to sudden failure and reduced cycle life. The origin of the degradation mechanisms stem from surface heterogeneities introduced during Li foil manufacturing and storage [1, 2]. As cycling progresses, the local heterogeneities propagate, resulting in uneven Li utilization and degradation-prone regions across the electrode [3], which consequently induce performance variations at the cell level. This heterogeneity propagation is particularly pronounced in large-format pouch cells in practical applications, where the surface effects are magnified. Without a clear understanding of the multi-scale heterogeneities and the development of surface homogenization methods, the performance consistency will be compromised, hindering the commercialization of Li metal batteries. In this presentation, we investigate the evolution of surface heterogeneity propagation on commercially available Li foils. We discover that inhomogeneous Li utilization appears as early as the first half-cycle of formation, manifesting as localized clusters and pits. In pouch cell configurations, these features exhibit areal density variations across the electrode on a scale of millimeters. To improve Li utilization homogeneity, a scalable mechanical brushing method is introduced to remove the chemically heterogeneous surface passivation layer. Furtherore, the influence of utilization homogeneity on cell-to-cell consistency is evaluated using 32 Li-NMC811 pouch cells divided into as-received and brushed Li groups. On the brushed Li, clusters and pits are no longer observable, and the cells exhibit significantly improved consistency in discharge capacity trajectories and cycle lifetime. Overall, this study highlights the role of Li surface utilization homogeneity on long-term cycling performance. Our research provides a pathway for improving large-area electrode uniformity and establishing evaluation methods for cell-to-cell consistency, both are key steps toward the commercialization of Li metal batteries and beyond. [1] Otto, Svenja-K., et al. "In-depth characterization of lithium-metal surfaces with XPS and ToF-SIMS: toward better understanding of the passivation layer." Chemistry of Materials 33.3 (2021): 859-867. [2] Hatzell, Kelsey, et al. "Aligning lithium metal battery research and development across academia and industry." Joule (2024). [3] Kim, Sangwook, et al. "Calendar life of lithium metal batteries: Accelerated aging and failure analysis." Energy Storage Materials 65 (2024): 103147.

25 - ENERGY STORAGE↗

Determining the Efficiency of Nitrogen Blanketing to Mitigate Corrosion in Hanford’s Transfer Line System

The Hanford site stores large quantities of radioactive waste in underground, carbon-steel, double-shell tanks. The waste is transferred between the tanks using piping that consists of carbon-steel pipes and carbon-steel encasements. The transfer lines have shown extensive corrosion on both the interior of the casing and exterior of the carrier pipes. Nitrogen blanketing, used to displace the oxygen in the transfer lines, was hypothesized to reduce the corrosion of the transfer lines. Experimental studies were conducted to investigate the effect of oxygen concentration on the corrosion rate and the initiation of pitting on carbon steel. The results indicated that controlling the oxygen concentration to 0% effectively mitigates corrosion. However, at 5 vol% oxygen, a significant increase in the general corrosion rate and pitting corrosion is observed.

Atmospheric Corrosion↗

DOUBLE SHELL TANK (DST) INTEGRITY PROJECT HIGH LEVEL WASTE CHEMISTRY OPTIMIZATION

The U.S. Department of Energy's Office (DOE) of River Protection (ORP) has a continuing program for chemical optimization to better characterize corrosion behavior of High-Level Waste (HLW). The DOE controls the chemistry in its HLW to minimize the propensity of localized corrosion, such as pitting, and stress corrosion cracking (SCC) in nitrate-containing solutions. By improving the control of localized corrosion and SCC, the ORP can increase the life of the Double-Shell Tank (DST) carbon steel structural components and reduce overall mission costs. The carbon steel tanks at the Hanford Site are critical to the mission of safely managing stored HLW until it can be treated for disposal. The DOE has historically used additions of sodium hydroxide to retard corrosion processes in HLW tanks. This also increases the amount of waste to be treated. The reactions with carbon dioxide from the air and solid chemical species in the tank continually deplete the hydroxide ion concentration, which then requires continued additions. The DOE can reduce overall costs for caustic addition and treatment of waste, and more effectively utilize waste storage capacity by minimizing these chemical additions. Hydroxide addition is a means to control localized and stress corrosion cracking in carbon steel by providing a passive environment. The exact mechanism that causes nitrate to drive the corrosion process is not yet clear. The SCC is less of a concern in the newer stress relieved double shell tanks due to reduced residual stress. The optimization of waste chemistry will further reduce the propensity for SCC. The corrosion testing performed to optimize waste chemistry included cyclic potentiodynamic volarization studies. slow strain rate tests. and stress intensity factor/crack growth rate determinations. Laboratory experimental evidence suggests that nitrite is a highly effective:inhibitor for pitting and SCC in alkaline nitrate environments. Revision of the corrosion control strategies to a nitrite-based control, where there is no constant depletion mechanism as with hydroxide, should greatly enhance tank lifetime, tank space availability, and reduce downstream reprocessing costs by reducing chemical addition to the tanks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LOCALIZED CORROSION OF AUSTENITIC STAINLESS STEELEXPOSED TO MIXTURES OF PLUTONIUM OXIDE AND CHLORIDE SALTS

Laboratory corrosion tests were conducted to investigate the corrosivity of moist plutonium oxide/chloride (PuO{sub 2}/Cl-) salt mixtures on 304L and 316L stainless steel coupons. The tests exposed flat coupons for pitting evaluation and 'teardrop' stressed coupons for stress corrosion cracking (SCC) evaluation at room temperature to various mixtures of PuO{sub 2} and chloride-bearing salts for periods up to 500 days. The two flat coupons were placed so that the solid oxide/salt mixture contacted about one half of the coupon surface. One teardrop coupon was placed in contact with solid mixture; the second teardrop was in contact with the headspace gas only. The mixtures were loaded with nominally 0.5 wt % water under a helium atmosphere. Observations of corrosion ranged from superficial staining to pitting and SCC. The extent of corrosion depended on the total salt concentration and on the composition of the salt. The most significant corrosion was found in coupons that were exposed to 98 wt % PuO{sub 2}, 2 wt % chloride salt mixtures that contained calcium chloride. SCC was observed in two 304L stainless steel teardrop coupons exposed in solid contact to a mixture of 98 wt % PuO{sub 2}, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl{sub 2}. The cracking was associated with the heat-affected zone of an autogenous weld that ran across the center of the coupon. Cracking was not observed in coupons exposed to the headspace gas, nor in coupons exposed to other mixtures with either 0.92 wt% CaCl{sub 2} or no CaCl{sub 2}. The corrosion results point to the significance of the interaction between water loading and the concentration of the hydrating salt CaCl{sub 2} in the susceptibility of austenitic stainless steels to corrosion.

36 MATERIALS SCIENCE↗

Relative Humidity and the Susceptibility of Austenitic Stainless Steel to Stress Corrosion Cracking in an impure Plutonium Oxide Environment

Laboratory tests to investigate the corrosivity of moist plutonium oxide/chloride salt mixtures on 304L and 316L stainless steel coupons showed that corrosion occurred in selected samples. The tests exposed flat coupons for pitting evaluation and 'teardrop' stressed coupons for stress corrosion cracking (SCC) evaluation at room temperature to various mixtures of PuO{sub 2} and chloride-bearing salts for periods up to 500 days. The exposures were conducted in sealed containers in which the oxide-salt mixtures were loaded with about 0.6 wt % water from a humidified helium atmosphere. Observations of corrosion ranged from superficial staining to pitting and SCC. The extent of corrosion depended on the total salt concentration, the composition of the salt and the moisture present in the test environment. The most significant corrosion was found in coupons that were exposed to 98 wt % PuO{sub 2}, 2 wt % chloride salt mixtures that contained calcium chloride and 0.6 wt% water. SCC was observed in two 304L stainless steel teardrop coupons exposed in solid contact to a mixture of 98 wt % PuO{sub 2}, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl{sub 2}. The cracking was associated with the heat-affected zone of an autogenous weld that ran across the center of the coupon. Cracking was not observed in coupons exposed to the headspace gas above the solid mixture, or in coupons exposed to other mixtures with either no CaCl{sub 2} or 0.92 wt% CaCl{sub 2}. SCC was present where the 0.6 wt % water content exceeded the value needed to fully hydrate the available CaCl{sub 2}, but was absent where the water content was insufficient. These results reveal the significance of the relative humidity in the austenitic stainless steels environment to their susceptibility to corrosion. The relative humidity in the test environment was controlled by the water loading and the concentration of the hydrating salts such as CaCl{sub 2}. For each salt or salt mixture there is a threshold relative humidity below which the necessary liquid electrolyte cannot exist, and therefore below which the SCC risk is very low. This threshold is a thermodynamic quantity known as the deliquescence relative humidity that is dependent on the identity of the salt but is independent of the quantity of salt. Below the deliquescence RH there should be low corrosion risk, and above it the corrosion risk increases rapidly as a liquid phase, which is initially saturated with salt, grows and becomes more widespread in the container.

36 MATERIALS SCIENCE↗

Actinic imaging of native and programmed defects on a full-field mask

We describe the imaging and characterization of native defects on a full field extreme ultraviolet (EUV) mask, using several reticle and wafer inspection modes. Mask defect images recorded with the SEMA TECH Berkeley Actinic Inspection Tool (AIT), an EUV-wavelength (13.4 nm) actinic microscope, are compared with mask and printed-wafer images collected with scanning electron microscopy (SEM) and deep ultraviolet (DUV) inspection tools. We observed that defects that appear to be opaque in the SEM can be highly transparent to EUV light, and inversely, defects that are mostly transparent to the SEM can be highly opaque to EUV. The nature and composition of these defects, whether they appear on the top surface, within the multilayer coating, or on the substrate as buried bumps or pits, influences both their significance when printed, and their detectability with the available techniques. Actinic inspection quantitatively predicts the characteristics of printed defect images in ways that may not be possible with non-EUV techniques. As a quantitative example, we investigate the main structural characteristics of a buried pit defect based on EUV through-focus imaging.

36 MATERIALS SCIENCE↗

Formation of pyramid-like nanostructures in MBE grown Si films on Si(001)

The growth of Si homoepitaxial layers on Si(001) substrates by molecular beam epitaxy is analyzed for a set of growth conditions in which diverse nanometric scale features develop. Using Si substrates prepared by exposure to HF vapor and annealing in ultra high vacuum, a rich variety of surface morphologies is found for different deposited layer thicknesses and substrate temperatures in a reproducible way, showing a critical dependence on both. Arrays of 3D islands (truncated pyramids), percolated ridge networks and square pit (inverted pyramids) distributions are observed. We analyze the obtained arrangements and find remarkable similarities to other semiconductor though heteroepitaxial systems. The nano-scale entities (islands or pits) display certain self assembly and ordering, concerning size, shape and spacing. Film growth sequence follows the islands-coalescence-2D growth pathway, eventually leading to optimum flat morphologies for high enough thickness and temperature.

36 MATERIALS SCIENCE↗