Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Automation of Nanoparticle Synthesis Processes in a Plasma Environment Using LabVIEW

This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.

PECVD↗

Fluoride-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model

In this report we present work performed in Fiscal Year 2022 that demonstrates the modeling and simulation of a fully coupled neutronics thermal hydraulics reference plant model for a fluoride-cooled high-temperature pebble-bed reactor. The multiphysics model is developed on the Nuclear Regulatory Commission’s Comprehensive Reactor Analysis Bundle (BlueCRAB) available on the Idaho National Laboratory’s high-performance computer, which natively and seamlessly couples Griffin, Pronghorn, and the BISON Multiphysics Object-Oriented Simulation Environment based applications. Griffin provides reactor physics capabilities, including depletion to the equilibrium core, k-eigenvalue, adjoint, and transient. The unique direct equilibrium core capability in Griffin is based on a streamline methodology to spatially deplete the pebbles into burnup groups. Pronghorn solves the porous medium equations for the fluid regions and conduction in the solid regions and incorporates a fluidic diode model to simulate the transition from forced to natural convection during accident scenarios. MOOSE modules solves thermal conduction problems for the pebbles and tristructural isotropic in the pebble-bed core, thus providing the fuel and moderator spatial fields for each pebble burnup group. The neutronics feedback relies primarily on fuel, moderator, and reflector temperatures as as well as the FLiBe salt density. Here, we present results for the uncoupled equilibrium core and perform comparisons to equivalent Monte Carlo models. The power distributions and kinetic parameters obtained with Griffin are consistent with those computed with Griffin. We demonstrate a noticeable improvement with the use of discrete ordinates method (SN) transport. The coupled steady-state equilibrium core provides the initial condition for two time-dependent problems: a control rod withdrawal event and an unprotected loss of flow event. In both cases, the reactor design is self-stabilizing and the solutions are consistent with the expected physics. Although this model is prototypical regarding BlueCRAB’s capabilities, its results are consistent with published work by Kairos Power and other research entities. Significant improvements to the model are planned in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Algorithms for Unit Commitment with AC Power Flows (Final Report)

Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bi-Directional On-Board Charger Architecture and Control for Achieving Ultra-High Efficiency with Wide Battery Voltage Range

One challenge of on board charger application is bi-directional operation. Due to the absence of reverse recovery charge and small junction capacitance, it is much easier to do bi-directional operation using wide band gap devices. Another challenge is the very wide battery voltage range. It is very difficult to optimize converter over the whole battery voltage range and efficiency drops either the battery voltage is too high or too low. In this paper, a novel two stage structure is proposed utilizing both SiC and GaN devices. Bi-directional power flow as well as zero voltage switching is achieved with the proposed structure. In addition, a variable DC-link voltage operation is adopted to deal with the wide battery voltage range so that the CLLC resonant converter can always work at its optimized point. Design considerations of the two stage on-board charger are introduced, including system structure evaluation, resonant converter design and control strategy. A 6.6kW on board charger prototype with 500kHz (300kH for AC/DC stage) switching frequency is demonstrated with 43W/in3 power density and above 96% efficiency over the whole battery voltage range.

Li, Bin↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Satellite Power Systems (SPS) concept definition study. Volume 5: Special emphasis studies

Satellite configurations based on the Satellite Power System baseline requirements were analyzed and a preferred concept selected. A satellite construction base was defined, precursor operations incident to establishment of orbital support facilities identified, and the satellite construction sequence and procedures developed. Rectenna construction requirement were also addressed. Mass flow to orbit requirements were revised and traffic models established based on construction of 60 instead of 120 satellites. Analyses were conducted to determine satellite control, resources, manufacturing, and propellant requirements. The impact of the laser beam used for space-to-Earth power transmission upon the intervening atmosphere was examined as well as the inverse effect. The significant space environments and their effects on spacecraft components were investigated to define the design and operational limits imposed by the environments on an orbit transfer vehicle. The results show that LEO altitude 300 nmi and transfer orbit duration 6 months are preferrable.

Hanley, G. M.↗

Numerical and Experimental Studies of the Natural Convection Flow Within a Horizontal Cylinder Subjected to a Uniformly Cold Wall Boundary Condition

Numberical solutions are obtained for the quasi-compressible Navier-Stokes equations governing the time dependent natural convection flow within a horizontal cylinder. The early time flow development and wall heat transfer is obtained after imposing a uniformly cold wall boundary condition on the cylinder. Solutions are also obtained for the case of a time varying cold wall boundary condition. Windware explicit differ-encing is used for the numerical solutions. The viscous truncation error associated with this scheme is controlled so that first order accuracy is maintained in time and space. The results encompass a range of Grashof numbers from 8.34 times 10,000 to 7 times 10 to the 7th power which is within the laminar flow regime for gravitationally driven fluid flows. Experiments within a small scale instrumented horizontal cylinder revealed the time development of the temperature distribution across the boundary layer and also the decay of wall heat transfer with time.

Stewart, R. B.↗

Deforestation reshapes land-surface energy-flux partitioning

Land-use and land-cover change significantly modify local land-surface characteristics and water/energy exchanges, which can lead to atmospheric circulation and regional climate changes. In particular, deforestation accounts for a large portion of global land-use changes, which transforms forests into other land cover types, such as croplands and grazing lands. Many previous efforts have focused on observing and modeling land–atmosphere–water/energy fluxes to investigate land–atmosphere coupling induced by deforestation. However, interpreting land–atmosphere–water/energy-flux responses to deforestation is often complicated by the concurrent impacts from shifts in land-surface properties versus background atmospheric forcings. In this study, we used 29 paired FLUXNET sites, to improve understanding of how deforested land surfaces drive changes in surface-energy-flux partitioning. Each paired sites included an intact forested and non-forested site that had similar background climate. We employed transfer entropy, a method based on information theory, to diagnose directional controls between coupling variables, and identify nonlinear cause–effect relationships. Transfer entropy is a powerful tool to detective causal relationships in nonlinear and asynchronous systems. The paired eddy covariance flux measurements showed consistent and strong information flows from vegetation activity (gross primary productivity (GPP)) and physical climate (e.g. shortwave radiation, air temperature) to evaporative fraction (EF) over both non-forested and forested land surfaces. More importantly, the information transfers from radiation, precipitation, and GPP to EF were significantly reduced at non-forested sites, compared to forested sites. We then applied these observationally constrained metrics as benchmarks to evaluate the Energy Exascale Earth System Model (E3SM) land model (ELM). ELM predicted vegetation controls on EF relatively well, but underpredicted climate factors on EF, indicating model deficiencies in describing the relationships between atmospheric state and surface fluxes. Moreover, changes in controls on surface energy flux partitioning due to deforestation were not detected in the model. We highlight the need for benchmarking model simulated surface-energy fluxes and the corresponding causal relationships against those of observations, to improve our understanding of model predictability on how deforestation reshapes land surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Korean Localization Program for Performance Verification Test of APR1400's RCP

The Korean government together with the Korean nuclear society completed the development of technologies for the design, manufacturing, and performance verification test of the APR1400's Reactor Coolant Pump (RCP) as one of the national programs for the localization of deficient nuclear technology. The RCP localization program was driven by KAERI, which was responsible for the development of the performance verification and evaluation technology, and by DOOSAN heavy industrial company, which was in charge of the design and manufacturing of the RCP. The test facility for the localized APR1400's RCP was constructed at the KAERI site at the end of 2012. The thermal hydraulic and electric capability of the RCP test facility (RCPTF) covers up to 18.5 MPa, 343 deg. C, 11.7 m{sup 3}/s, and 14.0 MW for the design pressure, temperature, flow rate, and maximum electric power, respectively. In 2013, a commissioning test was performed to verify its designed capability, followed by several modifications in the RCPTF including signal processing and control logic to enhance the verification and evaluation capability of the RCP performance. After finishing the commissioning and modification of the RCPTF, a type test for the new-type of RCP was performed successfully. In 2014 and 2015, eight production tests for the localized RCPs, which will be installed in a commercial nuclear power plant in Korea, were successfully completed. As a final stage of the localization program of the RCP, KAERI will perform a seal LOCA test to verify the leakage characteristics and produce experimental data on the localized seal assembly for a safety analysis during a station black out (SBO) condition. In this summary, several technical issues developed through a series of research processes for a performance verification test of the localized RCP are described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Start-up and Emergency Shutdown Modeling for a Coal-fired 10MWe sCO₂ Power Plant

As part of a Phase II Front End Engineering Design (FEED) study for the DOE Fossil Fuel Large Scale Pilots program, investigations of novel start-up and emergency shutdown methods for a stoker-fed, coal-fired, 10MWe sCO₂ power plant proposal were performed. These investigations were performed using 1D transient system models of the plant created within the GT-SUITE system modeling platform. The system model components were created using vendor quotation data (heat exchangers), performance maps (turbomachines), or FMU models (fired heater). Previously, Echogen Power Systems (Echogen) has used a sCO₂ power cycle start-up method that fills the system with liquid CO₂ to facilitate easy use of an electrically-driven start pump to transition the system from initial CO₂ fill to turbo-compressor initialization. The novel start-up method presented attempts this transition with a minimal filling of the system with liquid CO₂, to reduce the total CO₂ inventory required. This method leaves the start pump vulnerable to a two phase inlet condition as system pressure is below the CO₂ saturation pressure for the condenser cooling water temperature (Tcw). System model cases at Tcw of 18°C, 26°C, and 32°C, corresponding to cold, design, and hot ambient days, were analyzed to determine if the SP inlet condition could be kept as a subcooled liquid and estimate the CO₂ inventory reduction amount./p> Stoker-fed, coal-fired heaters continue to emit heat for some time even after emergency shutdown from events such as a power failure. This heat emission would lead to a failure of the fired heater, as the metal overheats, if the CO₂ flow is shut off. The emergency shutdown method presented utilizes CO₂ vented by a controllable vent valve (CRV) to provide CO₂ cooling flow to the fired heater. To determine the effectiveness of this method at keeping the fired heater peak tubing metal temperature below the ASME material temperature limit, for pressures below 5 MPa, of 816 °C, system model cases with CRV diameters ranging from 4” to 10”, and an alternative CO₂ vent routing with CRV size of 6”, were investigated./p>

01 COAL, LIGNITE, AND PEAT↗

Optimal Sizing and Placement of Battery Energy Storage in Distribution System Based on Solar Size for Voltage Regulation

This paper proposes a new strategy to achieve voltage regulation in distributed power systems in the presence of solar energy sources and battery storage systems. The goal is to find the minimum size of battery storage and its corresponding location in the network based on the size and place of the integrated solar generation. The proposed method formulates the problem by employing the network impedance matrix to obtain an analytical solution instead of using a recursive algorithm such as power flow. The required modifications for modeling the slack and PV buses (generator buses) are utilized to increase the accuracy of the approach. The use of reactive power control to regulate the voltage regulation is not always an optimal solution as in distribution systems R/X is large. In this paper the minimum size and the best place of battery storage is achieved by optimizing the amount of both active and reactive power exchanged by battery storage and its gridtie inverter (GTI) based on the network topology and R/X ratios in the distribution system. Simulation results for the IEEE 14-bus system verify the effectiveness of the proposed approach.

14 SOLAR ENERGY↗

Reinforcement Learning for Distribution Grid Optimization (PyCIGAR) v0.1

PyCIGAR is a python software package that merges off-the-shelf reinforcement learning libraries (RLLib and Ray) with electric power distribution system simulation tools (OpenDSS and a custom power flow solver built by LBL). PyCIGAR enables the training of neural networks to optimize the behavior of different components in the electric distribution grid, such as control systems in photovoltaic rooftop solar inverters and electric battery storage systems. The software package has been used to train neural networks to update settings in photovoltaic rooftop solar inverter control systems to mitigate cyber attacks on other solar photovoltaic rooftop devices.

Arnold, Daniel↗

A User Guide to PARET/ANL (V.7.6) (Rev.1)

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA, and has been used by the Reactor Conversion Program to determine the expected transient behavior of a large number of reactors. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗