Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems, e.g., emergency asset management. Included is an example case study: Hurricane Dolly damaging a synthetic 2000-bus test system during its landing in Southern Texas. We perform statistical analysis of damages and discuss topological effects on the example synthetic grid. Also, we include a cursory evaluation of impacts using simplified operational models. Finally, we discuss how our method can be extended to use even higher-fidelity meteorological data sets and suggest directions for future work.

contingencies↗

Development of Dynamic Model of a Ternary Pumped Storage Hydropower Plant

Hydropower is the largest source of renewable energy in the United States. Pumped storage hydropower (PSH) is a hydropower plant that can generate power when it operates as a hydro turbine, and it can absorb power from the electric grid when it is pumping water from the lower reservoir to the upper reservoir. The conventional role of PSH is as an energy arbitrage: it sells power when the price of electricity is high (i.e., during peak hours of energy demand), and it is operated as a pump during times when the price of electricity is low (e.g., midnight to dawn). PSH is an important part in hydropower generation. Currently, the total installed capacity is approximately 22 GW. Recently, a new type of PSH was developed, called ternary PSH (T-PSH). T-PSH is a type of advanced PSH that is different from conventional PSH and adjusted-speed PSH. T-PSH uses a single generator rotating in one direction with two different runners connected to the same shaft (i.e., one is for pumping water, and the other is for generating power as a turbine). This paper presents the development of a dynamic model of T-PSH for power system analysis. T-PSH can be operated in three different modes: generating mode, pumping mode, and hydraulic short-circuit (HSC) mode. The three modes of operation will be presented in this paper. A new combined governor is developed to represent the HSC operation mode, which is a special mode for T-PSH. The power command is divided into two parts, and a distribution coefficient is introduced to regulate the transitions from one mode to the other. Simulation and validation results are presented to verify the performance of the governor model and the characteristics of T-PSH.

15 GEOTHERMAL ENERGY↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Power grid frequency prediction using spatiotemporal modeling

Understanding power system dynamics is essential for interarea oscillation analysis and the detection of grid instabilities. The FNET/GridEye is a GPS-synchronized wide-area frequency measurement network that provides an accurate picture of the normal real-time operational condition of the power system-dynamics, giving rise to new and intricate spatiotemporal patterns of power loads. We propose to model FNET/GridEye grid frequency data from the U.S. Eastern Interconnection with a spatiotemporal statistical model. We predict the frequency data at locations without observations, a critical need during disruption events where measurement data are inaccessible. Spatial information is accounted for either as neighboring measurements in the form of covariates or with a spatiotemporal correlation model captured by a latent Gaussian field. Finally, the proposed method is useful in estimating power system dynamic response from limited phasor measurements and holds promise for predicting instability that may lead to undesirable effects such as cascading outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation

This paper develops a controller for a grid-forming (GFM) inverter that is capable of operating as either a GFM or grid-feeding source that can improve the operation of a microgrid during on-off grid transitions through use of a novel synchronization approach. Furthermore, this controller avoids use of a phase-locked loop (PLL) and the inverter is able to synchronize with the grid with self-generated voltage and frequency. This prevents the inverter from replicating any grid voltage disturbances in its output—a key disadvantage of many grid-connected inverters that use a PLL. To enable fast synchronization, active synchronization control is adopted both during inverter start-up and microgrid reconnection operation and a method of coordinating synchronization of the inverter with a microgrid controller and grid interconnection circuit breaker is presented. Simulation results for multiple microgrid transition operations and unplanned islanding events demonstrate that the developed non-PLL grid-connected GFM inverter controller and synchronization method are effective in synchronizing the inverter and microgrid to the grid, avoiding phase jump during microgrid transition operation, and improving microgrid islanding transients versus a traditional configuration.

27 ARPA - Advanced Research Projects Agency-Energy↗

Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors

The protection, control, and monitoring of the power grid is not possible without accurate measurement devices. As the percentage of renewable energy sources penetrating the existing grid infrastructure increases, so do uncertainties surrounding their effects on the everyday operation of the power system. Many of these devices are sources of high-frequency transients. These transients may be useful for identifying certain events or behaviors otherwise not seen in traditional analysis techniques. Therefore, the ability of sensors to accurately capture these phenomena is paramount. In this work, two commercial-grade power system distribution sensors are investigated in terms of their ability to replicate high-frequency phenomena by studying their responses to three events: a current inrush, a microgrid “close-in”, and a fault on the terminals of a wind turbine. Kernel density estimation is used to derive the non-parametric probability density functions of these error distributions and their adequateness is quantified utilizing the commonly used root mean square error (RMSE) metric. It is demonstrated that both sensors exhibit characteristics in the high harmonic range that go against the assumption that measurement error is normally distributed.

47 OTHER INSTRUMENTATION↗

Machine learning based energy management system for grid disaster mitigation

The recent increase in infiltration of distributed resources has challenged the traditional operation of power systems. Simultaneously, devastating effects of recent natural disasters have questioned the resilience of power infrastructure for an electricity dependent community. In this study, a solution has been presented in the form of a resilient smart grid network which utilizes Distributed Energy Resources (DERs) and Machine Learning (ML) algorithms to improve the power availability during disastrous events. In addition to power electronics with load categorization features, the presented system utilizes ML tools to use the information from neighbouring units and external sources to make complicated logical decisions directed towards provide power to critical loads at all times. Furthermore, provided model encourages consideration of ML tools as a part of smart grid design process together with power electronics and controls, not as an additional feature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

California-Specific Power-to-Hydrogen and Power-to-Gas Business Case Evaluation

Flexible operation of electrolysis systems represents an opportunity to reduce the cost of hydrogen for a variety of end-uses while also supporting grid operations and thereby enabling greater renewable penetration. California is an ideal location to realize that value on account of growing renewable capacity and markets for hydrogen as a fuel cell electric vehicle (FCEV) fuel, refineries, and other end-uses. Shifting the production of hydrogen to avoid high cost electricity and participation in utility and system operator markets along with installing renewable generation to avoid utility charges and increase revenue from the Low Carbon Fuel Standard (LCFS) program can result in around $2.5/kg (21%) reduction in the production and delivery cost of hydrogen from electrolysis. This reduction can be achieved without impacting the consumers of hydrogen. Additionally, future strategies for reducing hydrogen cost were explored and include lower cost of capital, participation in the Renewable Fuel Standard program, capital cost reduction, and increased LCFS value. Each must be achieved independently and could each contribute to further reductions. Using the assumptions in this study found a 29% reduction in cost if all future strategies are realized. Flexible hydrogen production can simultaneously improve the performance and decarbonize multiple energy sectors. The lessons learned from this study should be used to understand near-term cost drivers and to support longer-term research activities to further improve cost effectiveness of grid integrated electrolysis systems.

30 DIRECT ENERGY CONVERSION↗

Helical Fins for Concentrated Solar Receivers: Design Optimization and Entropy Analysis

Concentrated solar power (CSP) with thermal energy storage (TES) has the potential to achieve grid parity. This can be realized by operating CSP systems at temperatures above 700 °C with high-efficiency sCO 2 power cycles. However, operating CSP systems at such temperatures poses several challenges, among which the design of solar receivers to accommodate increased thermal loads is critical. To this end, this work explores and optimizes various swirl-inducing internal fin designs for solar receiver tubes. These fin designs not only improve the thermal performance of receiver tubes but also levelize temperature unevenness caused by non-uniform thermal loading. In this work, the geometric parameters of the fin designs are optimized to maximize the Nusselt number with a constraint on the friction factor. This optimization, however, is computationally intensive, requiring hundreds of simulation calls to computational fluid dynamics (CFD) models. Here, to circumvent this problem, surrogate models are used to approximate the simulation outputs needed during the optimization. In addition, this study also examines the fin designs from an entropy generation perspective. To this end, the entropy contributions from thermal and viscous effects are quantitatively compared while varying the operational Reynolds number.

14 SOLAR ENERGY↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Small-Signal Stability Analysis of Low-Inertia Power Grids with Inverter-Based Resources and Synchronous Condensers: Preprint

With the potential environmental impacts of conventional fossil fuels and the technology advances of grid interactive power electronics, inverter-based resources (IBRs) are playing a crucial role in modern power grids. However, due to the lack of physical inertia, IBRs are vulnerable to system disturbances. Further, conventional grid-following (GFL) inverters cannot actively establish the frequency and voltage, which could not be a appropriate solution for 100% inverter-based power grids. Grid-forming (GFM) control, as an emerging inverter control function, has drawn great attention in recent years, while it is still under development and pre-mature for large-scale field deployment. A potential solution for gradually transitioning into a 100% inverter-based power grid is to combine both IBRs and synchronous machines into a mixed generation portfolio. More importantly, synchronous machines can be operated as synchronous condensers (SCs) until they are retired. It is also worth mentioning that the stability analysis is of great importance to ensure the smooth transition from existing power grids to 100% inverter-based system, which is the main focus of this work with detailed modeling and modal analysis.

100% renewable↗

Identification of Worst Impact Zones for Power Grids During Extreme Weather Events Using Q-learning

Both the frequency and intensity of extreme weather events have been trending higher in recent years, leading to significant infrastructure damage in the electric grid. The impact of these extreme weather events is desired to be analyzed and quantified to help transmission and distribution system operators prepare for and prevent significant damage and subsequent loss of power. In this paper, we develop an approach that models the impact of extreme weather on the grid and identifies the worst impact zone using Q-learning (a reinforcement learning approach). The identification results reveal grid vulnerability to weather events and provide insights for system operators to help achieve optimal resource allocation and crew dispatch to minimize the adverse impacts of extreme weather. Simulation studies are conducted on the IEEE 123-node system to demonstrate the performance of the proposed approach.

distribution system↗

The Salem Smart Power Center: An Assessment of Battery Performance and Economic Potential

This paper presents an assessment of the economic potential of a 5 MW/1.25 MWh Energy Storage System (ESS) installed at the Salem Smart Power Center (SSPC), a smart grid technology demonstration facility owned and operated by Portland General Electric (PGE) in Salem, Oregon. The ESS and the grid conditions in which it operates were modeled using Pacific Northwest National Laboratory’s Battery Storage Evaluation Tool (BSET) to explore tradeoffs between services, and to develop optimal control strategies. This assessment monetized the value derived from nine services the SSPC could provide to PGE and the customers it serves. The ESS and the grid conditions in which it operates were modeled using PNNL’s in-house optimization tool BSET to explore tradeoffs between services, and to develop optimal control strategies. The analysis resulted in a number of lessons that provide crucial insights into the practical application of ESS, including; The SSPC, which was originally conceived as a research and test facility and built with the prevailing maturity technology level, was built at a cost ($20.4 million) that exceeds current day prices ($5.4 million) for a similarly designed and built 5 MW/1.25 MWh system; In terms of economic operation, the SSPC is currently underutilized, deployed only for primary frequency response. PNNL modeling indicates that optimal operation of the ESS could generate an additional value of $2.3 million over 20 years. It should also be noted that primary frequency response is the highest benefit application but requires a response from the SSPC only 17 hours each year. While optimally engaged, the ESS would provide arbitrage and ancillary services 78 percent of the time, but those services generate only 27 percent of the total value; Participation in Western EIM represents an interesting opportunity for PGE with a potential to generate $2.1 million value in PV terms over 20 years in the 5-min real-time market; With an energy to power ratio of only 0.25, the SSPC is not well suited to engage in most energy-intensive applications such as arbitrage or ancillary services. By upsizing the storage capacity to 5 MWh and 10MWh, the additional value allows the benefits ($13.3 million and 20.3 million, respectively) to exceed the system’s revenue requirements ($11.5 and $16.4 million, respectively). For the SSPC, ROI ratios exceeded 1.0 when the energy to power ratio fell between 0.5 and 3.5, and peaked at an energy to power ratio of 2.0. This report represents the output of the first of a two-phase effort. Phase II will involve the development of enhanced control strategies to assist PGE in realizing the benefits of energy storage in real-time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Why Do Electricity Policy and Competitive Markets Fail to Use Advanced PV Systems to Improve Distribution Power Quality?

The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. We discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.

14 SOLAR ENERGY↗

Virtual Oscillator Control Maintains Grid Operations with High Inverter Penetrations

VOC makes each inverter behave electrically like a spring, 'bouncing back' to its normal operating range when disturbed. Coupling these inverters electronically could result in a new way to stabilize power grids. VOC has been demonstrated in a microgrid using several small inverters. In addition, five custom-designed inverters have been built and will be tested with grid simulations at NREL using power hardware-in-the-loop technology. VOC may provide a simple method to keep microgrids stable -- a topic of growing interest as resilience to energy disruptions gains prominence. VOC may also provide a means to transition power grids from today's inertia-dominated systems to systems that do not rely on rotating machinery.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗