Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Design and evaluation of an integrated flight-control system concept for manual IFR VTOL operations

An integrated flight controller, display, and power management system design, suitable for all-weather VTOL flight operations onto small ships, is described. The flight controller uncouples the aircraft's translational and attitude motions, which are then commanded by the pilot, through separate controls. A head-up display provides situation and flight director information sufficient to permit zero-zero landings. The system was applied to a VTOL transport model and simulated on moving base simulators at Ames Research Center. Presented herein are results concerning the aircraft's general handling qualities and, in particular, its handling qualities during IFR landings onto a moving ship.

Merrick, V. K.↗

A Prototype High-Voltage Pulsed Power Supply for Control of the ITER Shattered Pellet Injection System Flyer Plate Valve

A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Powering the Blue Economy: A Survey of Station-Keeping Methods for Mooringless Platforms

The term “ocean platform” is used to reference everything from stationary, typically moored, buoys to mobile water vehicles, whether they operate on the ocean’s surface or underwater. For certain applications for which relatively stationary station-keeping conditions are desired, the use of mooring systems is not always a viable alternative either for economic, environmental, regulatory, or otherwise practical reasons, or a combination thereof, (e.g., short deployments, sensitive ecosystems, very deep project sites). Maintaining a platform at a single waypoint or reference location without being moored would require additional control systems and a power source to counteract the drift forces that would naturally displace it. Mobile platforms, which are usually untethered except for remotely operated vehicles, typically require energy input to power their station-keeping capabilities so that they hold or control their location in the ocean. Currently, most of these platforms use combustion engines or batteries for this purpose, which, depending on the specific systems, may be costly, pollute the environment, or create limitations on the length of the deployment. However, powering this kind of platforms with surrounding renewable resources (waves, currents, winds, or sun) has been identified as a promising solution to expand their application. The intent of this report is to investigate station-keeping methods for various ocean platforms that are not moored or otherwise anchored to the ocean floor, or another platform or vessel, paying particular interest to technologies that use marine renewable resources to power their operation, because that is of particular interest to the U.S. Department of Energy’s Powering the Blue Economy (PBE) initiative. As a first step, 72 articles and technical reports related to mooringless station-keeping methods were collected for review. The preliminary literature review provided a broad overview of common themes across the literature from which a descriptive methodology for analyzing various platforms was developed. That is, station-keeping methods were categorized based on their predominant energy source and consumption (renewable, nonrenewable, or hybrid if the platform uses renewable and nonrenewable resources equally), and their localization strategy (drift reduction, “path-planning or “waypoint-holding”). In addition, platform types were segregated into the following groups: buoys, surface drifters, and unoccupied surface vehicles (USVs); offshore renewable energy systems; and unoccupied underwater vehicles (UUVs). The main types of station-keeping methods encountered in this report achieve their intended localization strategy by means of drift mitigation, steering, and/or propulsion. Drift mitigation is commonly accomplished via drogues and sea anchors. Stand-along steering subsystems use control surfaces (e.g., ship rudder, wing sail, etc.) that react to ocean currents, waves, or winds to provide varying-degrees of course adjustments. Combined steering and propulsion subsystems include differential thrusters, directional thrusters separate from a primary thruster that cause the platform to pitch up/down or yaw clockwise/counterclockwise, or vectored thrusters that direct the propulsion in a range of directions relative to the platform’s local coordinate system. Propulsion is often achieved by running a motor and applying active control strategies but can also involve buoyancy shifts and using sails to generate lifting forces that propel a platform in a desired direction. Future research is primarily expected to take place in the form of a technoeconomic analysis that would aim to determine the technological viability, cost, and added value of mooringless station-keeping use cases identified through this research, including docking for UUV recharging or for georeferencing drifter buoys, deep-sea floating wind farms, U.S. Navy sonar arrays, and a Pacific Ocean wave buoy network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Modeling and Simulation of In-Stream Hydrokinetic Turbines for Power Management and Control

Electricity generation from moving currents without using dams (i.e., in-stream hydrokinetic electricity) has the potential to introduce multiple GW of renewable power to U.S. grids. Here this study evaluates a control system designed to regulate the generator rotor rate (rpm) to improve power production from in-stream hydrokinetic turbines. The control algorithm is evaluated using numerical models of both a rigidly mounted tidal turbine (TT) and a moored ocean current turbine (OCT) coupled to an induction electric machine model. The moored simulation utilizes an innovative approach for coupling a multiple degrees-of-freedom (DOF) nonlinear hydrodynamic/mechanical turbine model with a nonlinear electromechanical generator model. Based on the turbine torque-speed characteristic, as well as the asynchronous machine features, a proportional–integral (PI) controller is used to generate a correction term for the frequency of the three-phase sinusoidal voltages that are supplied to the asynchronous generator. The speed control of the induction generator through the supply frequency is accomplished by a simplified voltage source inverter (VSI). The simplified VSI consists of control voltage sources (CVSs), while the comparison with a real VSI using diodes and transistors, which are controlled by pulse width modulation (PWM) technique, is also presented. Simulations are used to evaluate the developed algorithms showing that rpm fluctuations are around 0.02 for a tidal turbine operating in a wave field with a 6 m significant wave height and around 0.005 for a moored ocean current turbine operating in a wave field with a 2 m significant wave height.

16 TIDAL AND WAVE POWER↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Theoretical Solid Oxide Fuel Cell Model for System Controls and Stability Design

As the aviation industry moves towards higher efficiency electrical power generation, all electric aircraft, or zero emissions and more quiet aircraft, fuel cells are sought as the technology that can deliver on these high expectations. The Hybrid Solid Oxide Fuel Cell system combines the fuel cell with a microturbine to obtain up to 70 percent cycle efficiency, and then distributes the electrical power to the loads via a power distribution system. The challenge is to understand the dynamics of this complex multi-discipline system, and design distributed controls that take the system through its operating conditions in a stable and safe manner while maintaining the system performance. This particular system is a power generation and distribution system and the fuel cell and microturbine model fidelity should be compatible with the dynamics of the power distribution system in order to allow proper stability and distributed controls design. A novel modeling approach is proposed for the fuel cell that will allow the fuel cell and the power system to be integrated and designed for stability, distributed controls, and other interface specifications. This investigation shows that for the fuel cell, the voltage characteristic should be modeled, but in addition, conservation equation dynamics, ion diffusion, charge transfer kinetics, and the electron flow inherent impedance should also be included.

Kopasakis, George↗

Power grid reliability and security

This project has led to the development of a real-time simulation platform for electric power grids called Grid Simulator or GridSim for simulating the dynamic and information network interactions of large- scale power systems. The platform consists of physical models of power system components including synchronous generators, loads and control, which are simulated using a modified commercial power simulator namely Transient Stability Analysis Tool (TSAT) [1] together with data cleanup components, as well as an emulated substation level and wide-area power analysis components. The platform also includes realistic representations of communication network middleware that can emulate the real-time information flow back and forth between substations and control centers in wide-area power systems. The platform has been validated on a realistic 6000-bus model of the western American power system. The simulator GridSim developed in this project is the first of its kind in its ability to simulate real-time response of large-scale power grids, and serves as a cost effective real-time stability and control simulation platform for power industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

Ferencz, Andrew↗

The Effect of Reaction Control System Thruster Plume Impingement on Orion Service Module Solar Array Power Production

NASA's new Orion Crew Exploration Vehicle has geometry that orients the reaction control system (RCS) thrusters such that they can impinge upon the surface of Orion's solar array wings (SAW). Plume impingement can cause Paschen discharge, chemical contamination, thermal loading, erosion, and force loading on the SAW surface, especially when the SAWs are in a worst-case orientation (pointed 45 towards the aft end of the vehicle). Preliminary plume impingement assessment methods were needed to determine whether in-depth, timeconsuming calculations were required to assess power loss. Simple methods for assessing power loss as a result of these anomalies were developed to determine whether plume impingement induced power losses were below the assumed contamination loss budget of 2 percent. This paper details the methods that were developed and applies them to Orion's worst-case orientation.

Bury, Kristen M.↗

Instrumentation and Control Needs for Reliable Operation of Lunar Base Surface Nuclear Power Systems

As one of the near-term goals of the President's Vision for Space Exploration, establishment of a multi-person lunar base will require high-endurance power systems which are independent of the sun, and can operate without replenishment for several years. These requirements may be obtained using nuclear power systems specifically designed for use on the lunar surface. While it is envisioned that such a system will generally be supervised by humans, some of the evolutions required maybe semi or fully autonomous. The entire base complement for near-term missions may be less than 10 individuals, most or all of which may not be qualified nuclear plant operators and may be off-base for extended periods thus, the need for power system autonomous operation. Startup, shutdown, and load following operations will require the application of advanced control and health management strategies with an emphasis on robust, supervisory, coordinated control of, for example, the nuclear heat source, energy conversion plant (e.g., Brayton Energy Conversion units), and power management system. Autonomous operation implies that, in addition to being capable of automatic response to disturbance input or load changes, the system is also capable of assessing the status of the integrated plant, determining the risk associated with the possible actions, and making a decision as to the action that optimizes system performance while minimizing risk to the mission. Adapting the control to deviations from design conditions and degradation due to component failures will be essential to ensure base inhabitant safety and mission success. Intelligent decisions will have to be made to choose the right set of sensors to provide the data needed to do condition monitoring and fault detection and isolation because of liftoff weight and space limitations, it will not be possible to have an extensive set of instruments as used for earth-based systems. Advanced instrumentation and control technologies will be needed to enable this critical functionality of autonomous operation. It will be imperative to consider instrumentation and control requirements in parallel to system configuration development so as to identify control-related, as well as integrated system-related, problem areas early to avoid potentially expensive work-arounds . This paper presents an overview of the enabling technologies necessary for the development of reliable, autonomous lunar base nuclear power systems with an emphasis on system architectures and off-the-shelf algorithms rather than hardware. Autonomy needs are presented in the context of a hypothetical lunar base nuclear power system. The scenarios and applications presented are hypothetical in nature, based on information from open-literature sources, and only intended to provoke thought and provide motivation for the use of autonomous, intelligent control and diagnostics.

Turso, James↗

Developing Fuel Cell Electric Powertrain Architectures for Commercial Vehicles

Here, this article addresses the architecture development for a commercial vehicle fuel cell electric powertrain by establishing a clear multi-step formalized workflow that employs a unique technoeconomic solution for architecture selection. The power capability of the fuel cell, the energy capacity and chemistry of the electrical energy storage (battery), the DC-DC converter (including the input current rating and isolation resistance requirements), the traction drive solution, the on-board hydrogen storage solution, and the real-time power-split management of the fuel cell and the battery are all considered and developed in this effort. The methods were used to select architecture for Class 8 urban, regional, and line haul applications. When compared to traditional load-following power-split controllers, an energy management power-split controller can increase system energy efficiency by up to 19.5%. The energy-efficient power-split controller may increase the required battery capacity for an equivalent life by up to 2.6 times. The impact on the total cost of ownership (TCO) for a variety of financial cases demonstrates that high C-rate capable batteries have the potential to provide better TCO solutions over a six-year vehicle life than low C-rate capable batteries. To achieve TCO parity with the 600 A non-isolated DC-DC converter case, the specific choice of the fuel cell DC-DC converter to achieve a target power output based on current levels (from 500 A to 2400 A) shows that efficiency decreases and cost increases due to the higher current, requiring fuel cell prices to decrease by $50–$100/kW, $60–$110/kW, and $100–$220/kW for urban, regional, and line haul applications, respectively. Key recommendations for powertrain system architectures are provided, with specifics based on vehicle dynamics, mission and application characteristics, end customer use-case profile, critical powertrain component costs, and architecture selection cost function. This study rigorously demonstrates the interplay of the above parameters, with a focus on TCO, and provides application decision-makers with a mechanism and well-defined set of impact factors to consider as part of their architecture selection process.

25 ENERGY STORAGE↗

NASA/DOD Control/Structures Interaction Technology, 1986

Control/structures interactions, deployment dynamics and system performance of large flexible spacecraft are discussed. Spacecraft active controls, deployable truss structures, deployable antennas, solar power systems for space stations, pointing control systems for space station gimballed payloads, computer-aided design for large space structures, and passive damping for flexible structures are among the topics covered.

Wright, Robert L.↗

Modernizing to an AI-Ready Control System

The Accelerator Controls Operations Research Network (ACORN) project will modernize the accelerator control system and upgrade power supplies to enable future operations of the Fermilab Accelerator Complex with megawatt proton beams. By focusing on MLOps, ACORN enables full integration of AI into the control system to allow safe and reliable improvements to accelerator beam operations.

43 PARTICLE ACCELERATORS↗

Relay Protection and Automation Systems Based on Programmable Logic Integrated Circuits

One of the most promising forms of developing the apparatus part of relay protection and automation devices is considered. The advantages of choosing programmable logic integrated circuits to obtain adaptive technological algorithms in power system protection and control systems are pointed out. The technical difficulties in the problems which today stand in the way of using relay protection and automation systems are indicated and a new technology for solving these problems is presented. Particular attention is devoted to the possibility of reconfiguring the logic of these devices, using programmable logic integrated circuits.

42 ENGINEERING↗