Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Predictive simulations of ITER including neutral beam driven toroidal rotation

Predictive simulations of ITER [R. Aymar et al., Plasma Phys. Control. Fusion 44, 519 (2002)], discharges are carried out for the 15 MA high confinement mode (H-mode) scenario using PTRANSP, the predictive version of the TRANSP code. The thermal and toroidal momentum transport equations are evolved using turbulent and neoclassical transport models. A predictive model is used to compute the temperature and width of the H-mode pedestal. The ITER simulations are carried out for neutral beam injection (NBI) heated plasmas, for ion cyclotron resonant frequency (ICRF) heated plasmas, and for plasmas heated with a mix of NBI and ICRF. It is shown that neutral beam injection drives toroidal rotation that improves the confinement and fusion power production in ITER. The scaling of fusion power with respect to the input power and to the pedestal temperature is studied. It is observed that, in simulations carried out using the momentum transport diffusivity computed using the GLF23 model [R. Waltz et al., Phys. Plasmas 4, 2482 (1997)], the fusion power increases with increasing injected beam power and central rotation frequency. It is found that the ITER target fusion power of 500 MW is produced with 20 MW of NBI power when the pedestal temperature is 3.5 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron thermal transport analysis in Tokamak a Configuration Variable

A Tokamak a Configuration Variable (TCV) [G. Tonetti, A. Heym, F. Hofmann et al., in Proceedings of the 16th Symposium on Fusion Technology, London, U.K., edited by R. Hemsworth (North-Holland, Amsterdam, 1991), p. 587] plasma with high power density (up to 8 MW/m{sup 3}) core deposited electron cyclotron resonance heating at significant plasma densities ({<=}7x10{sup 19} m{sup -3}) is analyzed for the electron thermal transport. The discharge distinguishes itself as it has four distinct high confinement mode (H-mode) phases. An Ohmic H-mode with type III edge localized modes (ELMs), which turns into a type I ELMy H-mode when the ECRH is switched on. The ELMs then vanish, which gives rise to a quasistationary ELM-free H-mode. This ELM-free phase can be divided into two, one without magnetohydrodynamics (MHD) and one with. The MHD mode in the latter case causes the confinement to drop by {approx}15%. For all four phases both large-scale trapped electron (TEM) and ion temperature gradient (ITG) modes and small-scale electron temperature gradient (ETG) modes are analyzed. The analytical TEM formulas have difficulty in explaining both the magnitude and the radial profile of the electron thermal flux. Collisionality governs the drive of the TEM, which for the discharge in question implies it can be driven by either the temperature or density gradient. The TEM response function is derived and it is shown to be relatively small and to have sharp resonances in its energy dependence. The ETG turbulence, predicted by the Institute for Fusion Studies electron gyrofluid code, is on the other hand driven solely by the electron temperature gradient. Both trapped and passing electrons add to the ETG instability and turbulent thermal flux. For easy comparison of the results of the above approaches and also with the Weiland model, a dimensionless error measure, the so-called average relative variance is introduced. According to this method the ETG model explains 70% of the variation in the electron heat diffusivity whereas the predictive capabilities of the TEM-ITG models are poor. These results for TCV support the conclusion that the ETG model is able to explain a wide range of anomalous electron transport data, in addition to existing evidence from ASDEX [F. Ryter, F. Leuterer, G. Pereverzev, H.-U. Fahrbach, J. Stober, W. Suttrop, and the ASDEX Upgrade Team, Phys. Rev. Lett. 86, 2325 (2001)], Tore Supra [G. T. Hoang, W. Horton, C. Bourdelle, B. Hu, X. Garbet, and M. Ottaviani, Phys. Plasmas 10, 405 (2003)] and the Frascati Tokamak Upgrade [A. Jacchia, F. D. Luca, S. Cirant, C. Sozzi, G. Bracco, A. Brushi, P. Buratti, S. Podda, and O. Tudisco, Nucl. Fusion 42, 1116 (2002)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle in cell simulation of a radiofrequency plasma jet expanding in vacuum

The effect of a pressure gradient (∼133 Pa–0.133 Pa) on electron and ion energy distributions in a radiofrequency (rf at 13.56 MHz) argon plasma jet is studied using a 1D-3v Particle In Cell (PIC) simulation. The PIC domain is three times that of the 0.018 m long plasma cavity and the total simulation time is 1 ms. Ion heating and acceleration up to a drift velocity about 2000 m s{sup −1} are measured along the jet's main expansion axis. Elastic and charge exchange ion-neutral collisions histograms computed at equilibrium during 0.74 ms show that charge exchange collisions act as the main neutral heating mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comments on Bechtel's "Radio Frequency Interference Test Procedure for Instrument and Control Systems"

A copy of the Radio Frequency Interference Test Procedure and sketches for the interconnections was provided to me by Mazhar Haq for review. The intent is to determine whether adverse interactions will be observed at the Russell City Energy Center (RCEC) site due to coupled RF fields from the KFAX / KTRB AM broadcast antenna array. Construction of the RCEC has been impacted by the generation of RF currents in closed loops when large cranes are used for moving materials, appropriate measures have been employed to eliminate safety issues affecting the workers. The impact of the larger RF fields on the sensors and control actuators is yet a concern. The Test Procedure describes the use of a temporary, 100 foot tall assembly of raceway, conduit, wiring and sensors that will be supported by a crane in the area of heat recovery system located closest to the antenna array. Sensors and actuators will be operated to observe whether the normal daytime operation of the broadcast transmitters results in functional impairment.

42 ENGINEERING↗

Application of Cryocoolers to a Vintage Dilution Refrigerator

A dilution refrigerator is required for 50mK detector operation of CDMS (Cryogenic Dark Matter Search). Besides shielding the dilution refrigerator itself, the liquid nitrogen shield and liquid helium bath in the refrigerator cool the detector cryostat heat shields and cool electronics, resulting in significant external heat loads at 80K and at 4K. An Oxford Instruments Kelvinox 400 has served this role for ten years but required daily transfers of liquid nitrogen and liquid helium. Complicating the cryogen supply is the location 800 meters below ground in an RF shielded, class 10000 clean room at Soudan, MN. Nitrogen and helium re-liquefiers using cryocoolers were installed outside the clean room and continuously condense room temperature gas and return the liquids to the dilution refrigerator through a transfer line. This paper will describe the design, installation, controls and performance of liquefaction systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanically Polishing Electroplated Nb3Sn for Higher Accelerating Gradients

As the demand for more efficient SRF technology continues to rise, so does the need to improve the performance of Nb3Sn, the most promising alternative to niobium. Leveraging recent breakthroughs in Nb3Sn research from Cornell University and Fermilab, namely the electrochemical synthesis-based growth of Nb3Sn and the centrifugal barrel polishing (CBP) technique to smoothen the final Nb3Sn film, our primary goal is to reduce surface roughness while preserving the film’s quality. We present promising RF results from an electroplated cavity that underwent mechanical polishing using the CBP technique, which showed an increase in the maximum accelerating gradient compared to the baseline test. However, contamination-induced Q-slope limited performance. Temperature mapping reveals quench location and heating response before, during and after quench.

Shpani, L. [Cornell U.]↗

Status of ECRH project on EAST Tokamak

A 140GHz electron cyclotron resonance heating and current drive (EC H and CD) project for EAST Tokamak is launched in 2011 with a total power of 4MW and pulse length of 100 s. The main objectives of the system are to provide central H and CD, assist start-up and control of MHD activities. The system comprises four gyrotrons each with nominal output power of 1MW at 140GHz. The RF power, transmitted through four evacuated corrugated waveguides will be injected into plasma from the low field side (radial port). The front steering equatorial launcher directs the RF beam over ±25° toroidally and scans over 38° poloidally. At present, the construction of the first 1MW system is undergoing for the expected campaign in the end of 2013. In this paper, the current status of the development and the design of the 140-GHz ECRH system are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

First HIBP results on the WEGA Stellarator

The heavy ion beam probe (HIBP) is an established non perturbing diagnostic for measuring the spatial distributions of plasma potential, density, temperature and poloidal magnetic field (axial current) of magnetically confined fusion plasma. These are determined from the change in the primary ion beam parameters (charge, intensity and trajectory) passing through a plasma volume due to collisions with electrons and interactions with the confining magnetic field. A heavy ion beam probe plasma diagnostic system has been installed and tested on the WEGA stellarator in Greifswald, Germany in 2006-2007. The WEGA HIBP operates with a beam of singly charged sodium ions with an energy of up to 60 keV, ion current up to 100 {mu}A, and beam diameter of 5-6 mm in the confined plasma region. Plasma experiments with the HIBP diagnostic system were carried out at a magnetic field strength of B{sub 0} = 0.489 T. In the experiments, an argon plasma was heated with ECRH at 28 GHz. In this work the first plasma potential and total current profile measurements results are presented. This work was supported by STCU P-202 project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An investigation during the system test phase of the GOES spacecraft

Spurious RF oscillations were noted during the system test phase of the Geostationary Operational Environmental Satellite (GOES). A space qualified data collection platform report (DCPR) transmitter was subsequently found to have a cracked load resistor in its output isolator. The failure mechanism was caused by heat from the output power of a 20 watt transmitter being reflected into the DCPR transmitter through a sneak path. The reflection from a high VSWR at the rotary joint was not part of the normal operation but was due to unusual circumstances. The reliability of the load resistor under normal operation (low VSWR) over the life of the satellite was determined to be high.

Mallette, L. A.↗

Helicon Wave Physics Impacts on Electrodeless Thruster Design

Effective generation of helicon waves for high density plasma sources is determined by the dispersion relation and plasma power balance. Helicon wave plasma sources inherently require an applied magnetic field of .01-0.1 T, an antenna properly designed to couple to the helicon wave in the plasma, and an rf power source in the 10-100 s of MHz, depending on propellant choice. For a plasma thruster, particularly one with a high specific impulse (>2000 s), the physics of the discharge would also have to address the use of electron cyclotron resonance (ECR) heating and magnetic expansion. In all cases the system design includes an optimized magnetic field coil, plasma source chamber, and antenna. A preliminary analysis of such a system, calling on experimental data where applicable and calculations where required, has been initiated at Glenn Research Center. Analysis results showing the mass scaling of various components as well as thruster performance projections and their impact on thruster size are discussed.

Gilland, James↗

Helicon Wave Physics Impacts on Electrodeless Thruster Design

Effective generation of helicon waves for high density plasma sources is determined by the dispersion relation and plasma power balance. Helicon wave plasma sources inherently require an applied magnetic field of .01-0.1 T, an antenna properly designed to couple to the helicon wave in the plasma, and an rf power source in the 10-100 s of MHz, depending on propellant choice. For a plasma thruster, particularly one with a high specific impulse (>2000 s), the physics of the discharge would also have to address the use of electron cyclotron resonance (ECR) heating and magnetic expansion. In all cases the system design includes an optimized magnetic field coil, plasma source chamber, and antenna. A preliminary analysis of such a system, calling on experimental data where applicable and calculations where required, has been initiated at Glenn Research Center. Analysis results showing the mass scaling of various components as well as thruster performance projections and their impact on thruster size are discussed.

Gilland, James H.↗

Electron Bernstein Wave Experiment on the Madison Symmetric Torus

A system to heat electrons and possibly drive off-axis field-aligned current is under development on the Madison Symmetric Torus RFP. Staged experiments have reached an input power of 150 kW at 3.6G Hz and have produced a localized increase in SXR emission during rf injection. This measured emission is consistent with modeling in its location, energy spectrum and dependence on radial diffusion within the plasma. The emission is strongest in the region where ray tracing predicts deposition of the injected power. The multi-chord SXR camera used is sensitive to 4-7 keV photons. Enhanced emission in this energy range is consistent with Fokker-Plank modeling of EBW injection. The enhanced SXR emission vanishes quickly when radial diffusion in the plasma is high (as indicated by m = 0 magnetic activity); this is also consistent with Fokker-Plank modeling. An increase of boron emission (and presumably boron within the plasma) is also observed during EBW injection. This presents an alternative explanation to the enhanced SXR emission. Subsequent experiments with a different antenna at 100 kW input showed a small increase in SXR emission near 3 keV. A higher frequency experiment (5.5 GHz) with more input power available is currently under construction. Initial tests are centered on a circular waveguide launcher which requires only a 5 cm circular port in the vacuum vessel and has a target launch power of 400 kW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of alpha particle loss from JET plasmas during ion cyclotron resonance frequency heating using a thin foil Faraday cup detector array

The loss of MeV alpha particles from JET plasmas has been measured with a set of thin foil Faraday cup detectors during third harmonic heating of helium neutral beam ions. Tail temperatures of {approx}2 MeV have been observed, with radial scrape off lengths of a few centimeters. Operational experience from this system indicates that such detectors are potentially feasible for future large tokamaks, but careful attention to screening rf and MHD induced noise is essential.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High frequency plasma generators for ion thruster applications

Two concepts for high frequency discharge ion thrusters are described. Both sources are designed for use with 30 cm grid sets and argon propellant and utilize multi-cusp permanent magnet geometries for plasma confinement. The RF induction source is a conventional design representing a synthesis of the RIT and multi-cusp concepts. The preliminary data (without system optimization) indicate a discharge efficiency comparable to that obtained in 30 cm hollow cathode multi-cusp argon thrusters. The electron cyclotron heating source is electrodeless and exhibits plasma characteristics which should lead to greatly reduced discharge chamber and screen sputter rates with the optimization of the magnetic fields, microwave frequency, and feed configuration.

Divergilio, W. F.↗

High power l-band fast phase shifter

Following successful testing of a concept prototype of a waveguide-based high power phase shifter, a design of a fast, high power device has been developed. The shifter uses two magnetically biased blocks of Yttrium Iron Garnet (YIG) positioned along the side walls of a rectangular waveguide. The cross-section of the waveguide is chosen to suppress unwanted RF modes that could otherwise compromise performance of the phase shifter. Static bias field in the YIG blocks is created by employing permanent magnets. Low inductance coils in the same magnetic circuit excite fast component of the bias field. Design of the device ensures effective heat extraction from the YIG blocks and penetration of the fast magnetic field inside the waveguide with minimum delay. This paper summarizes main steps in this development and gives brief description of the system.

43 PARTICLE ACCELERATORS↗

Scattering of radio frequency waves by blob-filaments

Radio frequency waves used for heating and current drive in magnetic confinement experiments must traverse the scrape-off-layer (SOL) and edge plasma before reaching the core. The edge and SOL plasmas are strongly turbulent and intermittent in both space and time. As a first approximation, the SOL can be treated as a tenuous background plasma upon which denser filamentary field-aligned blobs of plasma are superimposed. The blobs are approximately stationary on the rf time scale. The scattering of plane waves in the ion-cyclotron to lower-hybrid frequency range from a cylindrical blob is treated here in the cold plasma fluid model. Scattering widths are derived for incident fast and slow waves, and the scattered power fraction is estimated. Processes such as scattering-induced mode conversion, scattering resonances, and shadowing are investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-H-BRC-06: Temperature Simulation of Tungsten and W25Re Targets to Deliver High Dose Rate 10 MV Photons

Purpose: To study the impact of electron beam size, target thickness, and target temperature on the ability of the flattening filter-free mode (FFF) treatment head to deliver high-dose-rate irradiations. Methods: The dose distribution and transient temperature of the X-ray target under 10 MeV electron beam with pulse length of 5 microseconds, and repetition rate of 1000 Hz was studied. A MCNP model was built to calculate the percentage depth dose (PPD) distribution in a water phantom at a distance of 100 cm. ANSYS software was used to run heat transfer simulations. The PPD and temperature for both tungsten and W25Re targets for different electron beam sizes (FHWM 0.2, 0.5, 1 and 2 mm) and target thickness (0.2 to 2 mm) were studied. Results: Decreasing the target thickness from 1 mm to 0.5 mm, caused a surface dose increase about 10 percent. For both target materials, the peak temperature was about 1.6 times higher for 0.5 mm electron beam compared to the 1 mm beam after reaching their equilibrium. For increasing target thicknesses, the temperature rise caused by the first pulse is similar for all thicknesses, however the temperature difference for subsequent pulses becomes larger until a constant ratio is reached. The target peak temperature after reaching equilibrium can be calculated by adding the steady state temperature and the amplitude of the temperature oscillation. Conclusion: This work indicates the potential to obtain high dose rate irradiation by selecting target material, geometry and electron beam parameters. W25Re may not outperformed tungsten when the target is thick due to its relatively low thermal conductivity. The electron beam size only affects the target temperature but not the PPD. Thin target is preferred to obtain high dose rate and low target temperature, however, the resulting high surface dose is a major concern. NIH funding:R21 EB015957-01; DOD funding:W81XWH-13-1-0165 BL, PM, PB, and RF are founders of TibaRay, Inc. BL is also a borad member. BL and PM have received research grants from Varian Medical System, Inc. and RaySearch Laboratory. RF is an employee of Siemens Healthcare GmbH.

60 APPLIED LIFE SCIENCES↗