Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 3”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

ORNL Evaluation of Electrabel Safety Cases for Doel 3 / Tihange 2: Final Report

Oak Ridge National Laboratory (ORNL) performed a detailed technical review of the 2015 Electrabel (EBL) Safety Cases prepared for the Belgium reactor pressure vessels (RPVs) at Doel 3 and Tihange 2 (D3/T2). The Federal Agency for Nuclear Control (FANC) in Belgium commissioned ORNL to provide a thorough assessment of the existing safety margins against cracking of the RPVs due to the presence of almost laminar flaws found in each RPV. Initial efforts focused on surveying relevant literature that provided necessary background knowledge on the issues related to the quasilaminar flaws observed in D3/T2 reactors. Next, ORNL proceeded to develop an independent quantitative assessment of the entire flaw population in the two Belgian reactors according to the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, Appendix G, Fracture Toughness Criteria for Protection Against Failure, New York (1992 and 2004). That screening assessment of all EBL-characterized flaws in D3/T2 used ORNL tools, methodologies, and the ASME Code Case N-848, Alternative Characterization Rules for QuasiLaminar Flaws . Results and conclusions from the ORNL flaw acceptance assessments of D3/T2 were compared with those from the 2015 EBL Safety Cases. Specific findings of the ORNL evaluation of that part of the EBL structural integrity assessment focusing on stability of the flaw population subjected to primary design transients include the following: ORNL s analysis results were similar to those of EBL in that very few characterized flaws were found not compliant with the ASME (1992) acceptance criterion. ORNL s application of the more recent ASME Section XI (2004) produced only four noncompliant flaws, all due to LOCAs. The finding of a greater number of non-compliant flaws in the EBL screening assessment is due principally to a significantly more restrictive (conservative) criterion for flaw size acceptance used by EBL. ORNL s screening assessment results (obtained using an analysis methodology different from that of EBL) are interpreted herein as confirming the EBL screening results for D3/T2. ORNL s independent refined analysis demonstrated the EBL-characterized flaw 1660, which is non-compliant in the ORNL and EBL screening assessment, is rendered compliant when modeled as a more realistic individual quasi-laminar flaw using a 3-D XFEM analysis approach. ORNL s and EBL s refined analyses are in good agreement for the flaw 1660 close to the clad/base metal interface; ORNL is not persuaded that repeating this exercise for more than one non-compliant flaw is necessary to accept the EBL conclusions derived from the aggregate of EBL refined analysis results. ORNL General Conclusions Regarding the Structural Integrity Assessment (SIA) Conducted by EBL for D3/T2 Based on comparative evaluations of ORNL and EBL SIA analyses and on consideration of other results, ORNL is in agreement with the general conclusions reported by Electrabel in their RPV D3/T2 Technical Summary Note of April 14, 2015: More than 99 percent of flaws in D3/T2 meet the defined screening criterion, rendering them benign with respect to initiation in the event of a design transient. Refined analyses of non-compliant flaws from the screening assessment indicate that only 11 of the 16196 detected flaws have a critical reference-temperature material index (designated RTNDT) that implies the possibility of the initiation of cleavage fracture at some future time. For those 11 2 flaws, the calculated margin in RTNDT (a measure of acceptable embrittlement relative to end-ofservice-life conditions) is significant, being greater than 80 C. Fatigue crack growth is not a concern in the flaw-acceptability analyses. Primary stress re-evaluation confirms that the collapse pressure is more than 1.5 times the design pressure in the presence of defects detected in D3/T2. Sufficient conservatisms are built into the input data and into the different steps of the SIA; in some cases, those conservatisms are quantified and imply that additional margins exist in the SIA. Taken as a whole, the foregoing results and conclusions confirm the structural integrity of Doel 3 and Tihange 2 under all design transients with ample margin in the presence of the 16196 detected flaws.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Competitiveness Metrics for Electricity System Technologies

The relative economic competitiveness of power generation technologies is a topic of much interest to diverse electric industry participants. However, assessing competitiveness can be challenging as it requires considering both total costs and total system value of each technology, which are complicated by the (1) numerous and diverse grid services needed to operate a reliable power system; (2) variations in the economic value of the grid services with system state and location, and over multiple timescales, due to the challenges of transporting and storing electricity; and (3) the unique characteristics of different electric system assets. Ideally, metrics designed or used to convey technology competitiveness must consider these complexities, but existing metrics often fall short. For example, the levelized cost of energy does not consider the system economic value of the various technologies nor does it consider services beyond electricity production. Various other metrics have been designed with the purpose of more-accurately communicating the economic viability of electric system technologies. In this report, we summarize the primary sources and components of costs and value and review the known competitiveness metrics by presenting their definitions, applications, advantages, and disadvantages. We also introduce a new set of competitiveness metrics, which we refer to as System Profitability metrics, that more-directly applies the economic principles of return-on-investment to electric system technologies. We use conceptual examples to show how the System Profitability metrics better reflect economic viability and relative technology competitiveness compared with existing metrics. We also describe how competitiveness metrics can be quantified using optimization-based models and demonstrate this capability using a U.S. electric sector capacity expansion model.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coupled Neutronic and Thermal Hydraulic Analysis of a Natural Circulation Based Small Modular Reactor (SMR) Using VERA-CS

As part of the work supported by a US Department of Energy (DOE) Office of Nuclear Energy Gateway for Accelerated Innovation in Nuclear FY 2020 Voucher, Holtec International subsidiary SMR LLC (hereinafter referred to as Holtec) and Oak Ridge National Laboratory entered into a cooperative research and development agreement (CRADA) to develop coupled multiphysics core models of the Holtec developed small modular reactor (SMR), SMR-160. The scope of the 1 year project was to use the DOE–developed tool set, VERA, to analyze several aspects of a representative SMR-160 core design. The goals of the project were to perform the code-to-code benchmarking and to provide Holtec with a confirmatory calculations to compare against the results with the codes used in the SMR-160 design, identify and resolve areas of discrepancy between the two models to give Holtec a basis for selecting certain tool and model options, and develop a workflow so that the VERA model could be adapted easily to any future changes in the design of the SMR-160 core. The work proceeded in four phases: 1. Developing the initial VERA model based on Holtec-provided core design information; 2. Comparing VERA results with Holtec-provided calculations for the first five cycles; 3. Developing a VERA transient model based on the prior model; and 4. Training Holtec personnel on VERA and hand-off the developed models. This report summarizes at a high level the completed tasks. Details of the tasks and results are reserved for the full report, which will not be publicly released for 5 years per the terms of the CRADA. The report is titled “Coupled Neutronic and Thermal Hydraulic Analysis of a Natural Circulation Based Small Modular Reactor (SMR) using VERA-CS” and has the ORNL technical report number ORNL/TM 2021/2303 (NFE-20-08305)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BULK FLOWS FROM GALAXY LUMINOSITIES: APPLICATION TO 2MASS REDSHIFT SURVEY AND FORECAST FOR NEXT-GENERATION DATA SETS

We present a simple method for measuring cosmological bulk flows from large redshift surveys, based on the apparent dimming or brightening of galaxies due to their peculiar motion. It is aimed at estimating bulk flows of cosmological volumes containing large numbers of galaxies. Constraints on the bulk flow are obtained by minimizing systematic variations in galaxy luminosities with respect to a reference luminosity function measured from the whole survey. This method offers two advantages over more popular bulk flow estimators: it is independent of error-prone distance indicators and of the poorly known galaxy bias. We apply the method to the Two Micron All Sky Survey redshift survey to measure the local bulk flows of spherical shells centered on the Milky Way (MW). The result is consistent with that obtained by Nusser and Davis using the SFI++ catalogue of Tully-Fisher distance indicators. We also make an assessment of the ability of the method to constrain bulk flows at larger redshifts (z = 0.1-0.5) from next-generation data sets. As a case study we consider the planned EUCLID survey. Using this method we will be able to measure a bulk motion of {approx}200 km s{sup -1} of 10{sup 6} galaxies with photometric redshifts, at the 3{sigma} level for both z {approx} 0.15 and z {approx} 0.5. Thus, the method will allow us to put strong constraints on dark energy models as well as alternative theories for structure formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural Insights into HIV Reverse Transcriptase Mutations Q151M and Q151M Complex That Confer Multinucleoside Drug Resistance

HIV-1 reverse transcriptase (RT) is targeted by multiple drugs. RT mutations that confer resistance to nucleoside RT inhibitors (NRTIs) emerge during clinical use. Q151M and four associated mutations, A62V, V75I, F77L, and F116Y, were detected in patients failing therapies with dideoxynucleosides (didanosine [ddI], zalcitabine [ddC]) and/or zidovudine (AZT). The cluster of the five mutations is referred to as the Q151M complex (Q151Mc), and an RT or virus containing Q151Mc exhibits resistance to multiple NRTIs. To understand the structural basis for Q151M and Q151Mc resistance, we systematically determined the crystal structures of the wild-type RT/double-stranded DNA (dsDNA)/dATP (complex I), wild-type RT/dsDNA/ddATP (complex II), Q151M RT/dsDNA/dATP (complex III), Q151Mc RT/dsDNA/dATP (complex IV), and Q151Mc RT/dsDNA/ddATP (complex V) ternary complexes. The structures revealed that the deoxyribose rings of dATP and ddATP have 3'-endo and 3'-exo conformations, respectively. The single mutation Q151M introduces conformational perturbation at the deoxynucleoside triphosphate (dNTP)-binding pocket, and the mutated pocket may exist in multiple conformations. The compensatory set of mutations in Q151Mc, particularly F116Y, restricts the side chain flexibility of M151 and helps restore the DNA polymerization efficiency of the enzyme. The altered dNTP-binding pocket in Q151Mc RT has the Q151-R72 hydrogen bond removed and has a switched conformation for the key conserved residue R72 compared to that in wild-type RT. On the basis of a modeled structure of hepatitis B virus (HBV) polymerase, the residues R72, Y116, M151, and M184 in Q151Mc HIV-1 RT are conserved in wild-type HBV polymerase as residues R41, Y89, M171, and M204, respectively; functionally, both Q151Mc HIV-1 and wild-type HBV are resistant to dideoxynucleoside analogs.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Account of the Bonding Properties of a Rubredoxin Model Complex [Fe(SCH3)4]q, q = -2, -1, +2, +3

Iron-sulfur clusters play important roles in biology as parts of electron transfer chains and catalytic cofactors. Here, we report a detailed computational analysis of a structural model of the simplest natural iron-sulfur cluster of rubredoxin and its cationic counterparts. Specifically, we report results for the ground and low-lying electronically excited states of the complex [Fe(SCH3)4]2-/1-/2+/3+, using Multi-Reference (CASSCF, MRCISD), and Coupled Cluster [CCSD(T)] methodology in order to provide accurate adiabatic reduction energies, dissociation energies and insights into the bonding analysis. The nature of the Fe-S chemical bond and the magnitude of the ionization potentials in the anionic and cationic [Fe(SCH3)4] complexes offer a physical rationale for the relative stabilization, structure and speciation of these complexes. Anionic and cationic complexes present different types of chemical bonds: prevalently ionic in [Fe(SCH3)4]2-/1- complexes and covalent in [Fe(SCH3)4]2+/3+ complexes. The ionic bonds result in an energy gain for the transition [Fe(SCH3)4]2-®[Fe(SCH3)4]- (i.e., FeII®FeIII) of 1.5 eV, while the covalent bonds result in an energy loss for the transition [Fe(SCH3)4]2+®[Fe(SCH3)4]3+ of 16.6 eV, almost half of the IP of Fe2+. The ionic vs covalent bond character influences the Fe-S bond strength and length, i.e., ionic Fe-S bonds are longer than covalent ones by about 0.2 Å (for FeII) and 0.04 Å (for FeII). Finally, the average Fe-S heterolytic bond strength is 6.7 eV (FeII) and 14.6 (FeIII) eV at the RCCSD(T) level of theory.

Tzeli, Demeter↗

Linking soil phosphorus with forest litterfall resistance and resilience to cyclone disturbance: A pantropical meta-analysis

While tropical cyclone regimes are shifting with climate change, the mechanisms underpinning the resistance (ability to withstand disturbance-induced change) and resilience (capacity to return to pre-disturbance reference) of tropical forest litterfall to cyclones remain largely unexplored pantropically. Single-site studies in Australia and Hawaii suggest that litterfall on low-phosphorus (P) soils is more resistant and less resilient to cyclones. Here, we conducted a meta-analysis to investigate the pantropical importance of total soil P in mediating forest litterfall resistance and resilience to 22 tropical cyclones. We evaluated cyclone-induced and post-cyclone litterfall mass (g/m 2 /day), and P and nitrogen (N) fluxes (mg/m 2 /day) and concentrations (mg/g), all indicators of ecosystem function and essential for nutrient cycling. Across 73 case studies in Australia, Guadeloupe, Hawaii, Mexico, Puerto Rico, and Taiwan, total litterfall mass flux increased from ~2.5 ± 0.3 to 22.5 ± 3 g/m 2 /day due to cyclones, with large variation among studies. Litterfall P and N fluxes post-cyclone represented ~5% and 10% of the average annual fluxes, respectively. Post-cyclone leaf litterfall N and P concentrations were 21.6 ± 1.2% and 58.6 ± 2.3% higher than pre-cyclone means. Mixed-effects models determined that soil P negatively moderated the pantropical litterfall resistance to cyclones, with a 100 mg P/kg increase in soil P corresponding to a 32% to 38% decrease in resistance. Based on 33% of the resistance case studies, total litterfall mass flux reached pre-disturbance levels within one-year post-disturbance. A GAMM indicated that soil P, gale wind duration and time post-cyclone jointly moderate the short-term resilience of total litterfall, with the nature of the relationship between resilience and soil P contingent on time and wind duration. Across pantropical forests observed to date, our results indicate that litterfall resistance and resilience in the face of intensifying cyclones will be partially determined by total soil P.

59 BASIC BIOLOGICAL SCIENCES↗

First Look Fund - An Early-Stage Aligned Intermediary to Enhance the Flow of Private Capital into Energy Companies (Final Technical Report)

The technologies required to advance society into a cleaner, better future will come from a broad range of scientific disciplines including materials science, chemistry, physics, and biology. The innovations will rely on scientific breakthroughs rather than software innovation and can be referred to as “hardtech.” These new technology developments will have vast implications across most industrial sectors: energy, materials, manufacturing, electronics, life sciences, etc. The majority of these scientific breakthroughs will be produced and developed by startup companies, which are best suited for high-risk, early-stage development work. However, a large funding gap exists between lab-scale scientific research of the startup world and industrial-scale commercialization. Activate Global, Inc (Activate), a 501(c)3 nonprofit, fills one part of this gap with the Activate Fellowship program1.To fully bridge the gap between lab and market, additional and aligned capital sources are needed. Through this project, Activate’s goals were: Research the recent history (2005-2015) of hardtech investing to discover the driving forces behind positive and negative outcomes from the viewpoint of investors.; Create a database of “technology pathways” categorized by specific technology areas and showing what technology milestones would be needed to be attractive to a partner or acquirer and what resources were available to achieve those goals.; Build a financial model supported by the data acquired that would show attractive returns were possible in early-stage hardtech investing.; Create an investment thesis around the financial model to show how attractive returns could be achieved in an early-stage hardtech-focused fund.; Publish a paper with a qualitative comparative analysis to help investors better understand driving factors of outcomes.; Share these findings with asset managers not currently investing in early-stage hardtech to attract partners to execute the investment strategy.; Implement the investment strategy and begin investing in early-stage hardtech companies through a new vehicle: First Look Fund. Through this research, Activate created a database of nearly 200 hardtech companies that exited via an M&A transaction between 2005 and 2015. Much of the data Activate obtained was nonpublic information and therefore, the database was anonymized. Activate also created the technology pathways database to help new early-stage hardtech companies define milestones, technology objectives and potential resources. Activate created a financial model with a legal structure showing that market-rate returns were possible, created an investment thesis around that model, and then shared these findings with potential partners. Finally, Activate’s research was used to publish a paper with Stanford on driving factors behind financial outcomes that will help investors better guide their portfolios. While Activate was not able to launch the First Look Fund during the project timeline, mostly due to the fallout from COVID-19 (global economic shocks decreasing interest in first time funds, inability to meet potential investors in person), the research has created enough interest for Activate to continue pursuing the goals of the project, showing the potential feasibility of the endeavor. Regardless of Activate’s ability to execute on the investment strategy, the resulting research has been downloaded, viewed, and referenced by investors and becomes another tool to encourage investment in the early-stage hardtech space.

14 SOLAR ENERGY↗

Whole-core comet solutions to a 3-dimensional PWR benchmark problem with gadolinium

A pressurized water reactor (PWR) benchmark problem with gadolinium was used to determine the accuracy and computational efficiency of the coarse mesh radiation transport method COMET. The benchmark problem contains 193 square fuel assemblies. The COMET solution (eigenvalue, assembly averaged and fuel pin averaged fission density distributions) was compared with those obtained from the corresponding Monte Carlo reference solution using the same 2-group material cross section library. The comparison showed that both the core eigenvalue and fission density distribution averaged over each assembly and fuel pin predicated by COMET agree very well with the corresponding MCNP reference solution if the incident flux response expansion used in COMET is truncated at 2nd order in the two spatial and the two angular variables. The benchmark calculations indicate that COMET has Monte Carlo accuracy. In, particular, the eigenvalue difference between the codes ranged from 17 pcm to 35 pcm, being within 2 standard deviations of the calculational uncertainty. The mean flux weighted relative differences in the assembly and fuel pin fission densities were 0.47% and 0.65%, respectively. It was also found that COMET's full (whole) core computational speed is 30,000 times faster than MCNP in which only 1/8 of the core is modeled. It is estimated that COMET would have been about over 6 orders of magnitude faster than MCNP if the full core were also modeled in MCNP. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new approach to analytic, non-perturbative and gauge-invariant QCD

Following a previous calculation of quark scattering in eikonal approximation, this paper presents a new, analytic and rigorous approach to the calculation of QCD phenomena. In this formulation a basic distinction between the conventional 'idealistic' description of QCD and a more 'realistic' description is brought into focus by a non-perturbative, gauge-invariant evaluation of the Schwinger solution for the QCD generating functional in terms of the exact Fradkin representations of Green's functional G{sub c}(x,y|A) and the vacuum functional L[A]. Because quarks exist asymptotically only in bound states, their transverse coordinates can never be measured with arbitrary precision; the non-perturbative neglect of this statement leads to obstructions that are easily corrected by invoking in the basic Lagrangian a probability amplitude which describes such transverse imprecision. The second result of this non-perturbative analysis is the appearance of a new and simplifying output called 'Effective Locality', in which the interactions between quarks by the exchange of a 'gluon bundle'-which 'bundle' contains an infinite number of gluons, including cubic and quartic gluon interactions-display an exact locality property that reduces the several functional integrals of the formulation down to a set of ordinary integrals. It should be emphasized that 'non-perturbative' here refers to the effective summation of all gluons between a pair of quark lines-which may be the same quark line, as in a self-energy graph-but does not (yet) include a summation over all closed-quark loops which are tied by gluon-bundle exchange to the rest of the 'Bundle Diagram'. As an example of the power of these methods we offer as a first analytic calculation the quark-antiquark binding potential of a pion, and the corresponding three-quark binding potential of a nucleon, obtained in a simple way from relevant eikonal scattering approximations. A second calculation, analytic, non-perturbative and gauge-invariant, of a nucleon-nucleon binding potential to form a model deuteron, will appear separately. - Highlights: Black-Right-Pointing-Pointer An analytic, non-perturbative and gauge-invariant formulation for QCD processes. Black-Right-Pointing-Pointer A new property called Effective Locality appears in the QCD fermionic amplitudes. Black-Right-Pointing-Pointer An effective quark-antiquark and 3-quark binding potential is obtained. Black-Right-Pointing-Pointer A single 'gluon bundle' replaces the sum of an infinite number of Feynman graphs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Macroscopic and microscopic behaviors of Mn(II) (ad)sorption to goethite with the effects of dissolved carbonates under anoxic conditions

Manganese and its compounds have been extensively researched because of their far-reaching roles in a wide range of biogeochemical processes in natural systems. The (ad)sorption behavior of Mn(II), however, is poorly understood despite its important role as the primary reaction step for surface-catalyzed Mn(II) oxidation that is the principal abiotic process forming various Mn (oxyhydr)oxides in nature. Here, we systematically examined Mn(II) (ad)sorption to one of the most common natural sorbents, goethite, in oxygen- and carbonate-free systems. Traditional sorption edge and isotherm experiments were conducted by varying sorbate-to-sorbent ratio (0.027–15 μmol∙m -2 ) and solution pH (pH 5.0–9.0). The effects of dissolved carbonates on Mn(II) sorption were also assessed in a range of naturally prevalent concentrations (0.5–10 mM NaHCO 3 ). The Mn(II) uptake on goethite followed a typical Langmuir isotherm in the absence of dissolved carbonates, with increasing maximum adsorption capacities (Γ max ) from 0.19 at pH 6.5 to 3.4 μmol∙m -2 at pH 9.0. The presence of dissolved carbonates raised the extent of Mn(II) adsorption, which appeared to be directly correspondent to that of the adsorption of dissolved carbonates. Extended X-ray absorption fine structure (EXAFS) analysis indicated that Mn(II) predominantly formed inner-sphere binuclear bidentate surface complexes. Mn(II) uptake became deviated from the Langmuir model and showed a clear indication of surface precipitation when the Mn(II) sorption density (Γ) exceeded a threshold value in a given solution composition. This secondary Mn(II) phase was identified as rhodochrosite using X-ray diffraction (XRD) and transmission electron microscope (TEM). Furthermore, it would be plausible that a minor fraction of adsorbed Mn(II) coexisted with the secondary rhodochrosite according to a linear combination fitting (LCF) of the X-ray absorption near edge structure (XANES) spectra of Mn reference and samples. These systematic investigations of the macroscopic and microscopic behaviors of Mn(II) (ad)sorption to goethite provide a critical avenue for disentangling surface-catalytic Mn(II) oxidation processes, which ultimately lead to the formation of diverse Mn (oxyhydr)oxides in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

EnergyFit Nevada (formerly known as the Nevada Retrofit Initiative) final report and technical evaluation

The EnergyFit Nevada (EFN) Better Buildings Neighborhood Program (BBNP, and referred to in this document as the EFN program) currently encourages Nevada residents to make whole-house energy-efficient improvements by providing rebates, financing, and access to a network of qualified home improvement contractors. The BBNP funding, consisting of 34 Energy Efficiency Conservation Block Grants (EECBG) and seven State Energy Program (SEP) grants, was awarded for a three-year period to the State of Nevada in 2010 and used for initial program design and implementation. By the end of first quarter in 2014, the program had achieved upgrades in 553 homes, with an average energy reduction of 32% per home. Other achievements included: Completed 893 residential energy audits and installed upgrades in 0.05% of all Nevada single-family homes1 Achieved an overall conversation rate of 38.1%2 7,089,089 kWh of modeled energy savings3 Total annual homeowner energy savings of approximately $525,7523 Efficiency upgrades completed on 1,100,484 square feet of homes3 $139,992 granted in loans to homeowners for energy-efficiency upgrades 29,285 hours of labor and $3,864,272 worth of work conducted by Nevada auditors and contractors4 40 contractors trained in Nevada 37 contractors with Building Performance Institute (BPI) certification in Nevada 19 contractors actively participating in the EFN program in Nevada 1 Calculated using 2012 U.S. Census data reporting 1,182,870 homes in Nevada. 2 Conversion rate through March 31, 2014, for all Nevada Retrofit Initiative (NRI)-funded projects, calculated using the EFN tracking database. 3 OptiMiser energy modeling, based on current utility rates. 4 This is the sum of $3,596,561 in retrofit invoice value and $247,711 in audit invoice value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ALTERNATIVES TO HELIUM-3 FOR NEUTRON MULTIPLICITY DETECTORS

Collaboration between the Pacific Northwest National Laboratory (PNNL) and the Los Alamos National Laboratory (LANL) is underway to evaluate neutron detection technologies that might replace the high-pressure helium (3He) tubes currently used in neutron multiplicity counter for safeguards applications. The current stockpile of 3He is diminishing and alternatives are needed for a variety of neutron detection applications including multiplicity counters. The first phase of this investigation uses a series of Monte Carlo calculations to simulate the performance of an existing neutron multiplicity counter configuration by replacing the 3He tubes in a model for that counter with candidate alternative technologies. These alternative technologies are initially placed in approximately the same configuration as the 3He tubes to establish a reference level of performance against the 3He-based system. After these reference-level results are established, the configurations of the alternative models will be further modified for performance optimization. The 3He model for these simulations is the one used by LANL to develop and benchmark the Epithermal Neutron Multiplicity Counter (ENMC) detector, as documented by H.O. Menlove, et al. in the 2004 LANL report LA-14088. The alternative technologies being evaluated are the boron-tri-fluoride-filled proportional tubes, boron-lined tubes, and lithium coated materials previously tested as possible replacements in portal monitor screening applications, as documented by R.T. Kouzes, et al. in the 2010 PNNL report PNNL-72544 and NIM A 623 (2010) 1035–1045. The models and methods used for these comparative calculations will be described and preliminary results shown

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water use in the development and operation of geothermal power plants.

Geothermal energy is increasingly recognized for its potential to reduce carbon emissions and U.S. dependence on foreign oil. Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies. This report summarizes what is currently known about the life cycle water requirements of geothermal electric power-generating systems and the water quality of geothermal waters. It is part of a larger effort to compare the life cycle impacts of large-scale geothermal electricity generation with other power generation technologies. The results of the life cycle analysis are summarized in a companion report, Life Cycle Analysis Results of Geothermal Systems in Comparison to Other Power Systems. This report is divided into six chapters. Chapter 1 gives the background of the project and its purpose, which is to inform power plant design and operations. Chapter 2 summarizes the geothermal electricity generation technologies evaluated in this study, which include conventional hydrothermal flash and binary systems, as well as enhanced geothermal systems (EGS) that rely on engineering a productive reservoir where heat exists but water availability or permeability may be limited. Chapter 3 describes the methods and approach to this work and identifies the four power plant scenarios evaluated: a 20-MW EGS plant, a 50-MW EGS plant, a 10-MW binary plant, and a 50-MW flash plant. The two EGS scenarios include hydraulic stimulation activities within the construction stage of the life cycle and assume binary power generation during operations. The EGS and binary scenarios are assumed to be air-cooled power plants, whereas the flash plant is assumed to rely on evaporative cooling. The well field and power plant design for the scenario were based on simulations using DOE's Geothermal Economic Technology Evaluation Model (GETEM). Chapter 4 presents the water requirements for the power plant life cycle for the scenarios evaluated. Geology, reservoir characteristics, and local climate have various effects on elements such as drilling rate, the number of production wells, and production flow rates. Over the life cycle of a geothermal power plant, from construction through 30 years of operation, plant operations is where the vast majority of water consumption occurs. Water consumption refers to the water that is withdrawn from a resource such as a river, lake, or non-geothermal aquifer that is not returned to that resource. For the EGS scenarios, plant operations consume between 0.29 and 0.72 gal/kWh. The binary plant experiences similar operational consumption, at 0.27 gal/kWh. Far less water, just 0.01 gal/kWh, is consumed during operations of the flash plant because geofluid is used for cooling and is not replaced. While the makeup water requirements are far less for a hydrothermal flash plant, the long-term sustainability of the reservoir is less certain due to estimated evaporative losses of 14.5-33% of produced geofluid at operating flash plants. For the hydrothermal flash scenario, the average loss of geofluid due to evaporation, drift, and blowdown is 2.7 gal/kWh. The construction stage requires considerably less water: 0.001 gal/kWh for both the binary and flash plant scenarios and 0.01 gal/kWh for the EGS scenarios. The additional water requirements for the EGS scenarios are caused by a combination of factors, including lower flow rates per well, which increases the total number of wells needed per plant, the assumed well depths, and the hydraulic stimulation required to engineer the reservoir. Water quality results are presented in Chapter 5. The chemical composition of geofluid has important implications for plant operations and the potential environmental impacts of geothermal energy production. An extensive dataset containing more than 53,000 geothermal geochemical data points was compiled and analyzed for general trends and statistics for typical geofluids. Geofluid composition was found to vary significantly both among and within geothermal fields. Seven main chemical constituents were found to account for 95-99% of the dissolved solids in typical geofluids. In order of abundance, they were chloride, sodium, bicarbonate, sulfate, silica, calcium, and potassium. The potential for water and soil contamination from accidents and spills was analyzed by comparing geofluid composition with U.S. drinking water standards. Geofluids were found to present a potential risk to drinking water, if released, due to high concentrations of antimony, arsenic, lead, and mercury. That risk could be mitigated through proper design and engineering controls. The concentration and impact of noncondensible gases (NCG) dissolved in the geofluid was evaluated. The majority of NCG was either nitrogen or carbon dioxide, but a small number of geofluids contain potentially recoverable concentrations of hydrogen or methane.

15 GEOTHERMAL ENERGY↗

Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI

Purpose: Four-dimensional computed tomography-magnetic resonance imaging (4DCT-MRI) is an image-processing technique for simulating many 4DCT data sets from a static reference CT and motions extracted from 4DMRI studies performed using either volunteers or patients. In this work, different motion extraction approaches were tested using 6 liver cases, and a detailed comparison between 4DCT-MRI and 4DCT was performed. Methods and Materials: 4DCT-MRI has been generated using 2 approaches. The first approach used motion extracted from 4DMRI as being “most similar” to that of 4DCT from the same patient (subject-specific), and the second approach used the most similar motion obtained from a motion library derived from 4DMRI liver studies of 13 healthy volunteers (population-based). The resulting 4DCT-MRI and 4DCTs were compared using scanned proton 4D dose calculations (4DDC). Results: Dosimetric analysis showed that 93% ± 8% of points inside the clinical target volume (CTV) agreed between 4DCT and subject-specific 4DCT-MRI (gamma analysis: 3%/3 mm). The population-based approach however showed lower dosimetric agreement with only 79% ± 14% points in the CTV reaching the 3%/3 mm criteria. Conclusions: 4D CT-MRI extends the capabilities of motion modeling for dose calculations by accounting for realistic and variable motion patterns, which can be directly employed in clinical research studies. We have found that the subject-specific liver modeling appears more accurate than the population-based approach. The former is particularly interesting for clinical applications, such as improved target delineation and 4D dose reconstruction for patient-specific QA to allow for inter- and/or intra-fractional plan corrections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗