Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Cathodoluminescence insights into the ionic disorder of photocatalytic anatase films

The nature of ionic disorder and the effect of structural defects on the photocatalytic function of anatase are revisited in the light of direct experimental evidence retrieved on the molecular scale by cathodoluminescence (CL) spectroscopy. CL spectra, collected on different types of photocatalytically efficient or inefficient anatase films, embodied a composite optical response of electron-compensating majority types of ionic disorder in the anatase lattice. This paper describes the dual experimental output obtained by systematically monitoring optically active off-stoichiometry sites, as follows: (i) quantitative analyses of film stoichiometry including the interactions of different lattice-defect populations; and (ii) stability/evolution of off-stoichiometry sites upon post-fabrication annealing cycles and their effects on the photocatalytic activity of the films. CL experiments provided us with direct access to the structural state of the defective anatase lattice, thus unfolding some missing detail about the complex physicochemical interactions behind its photocatalytic efficiency.

36 MATERIALS SCIENCE↗

Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy

Purpose: To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at {sup 60}Co energies. High energy photon beams are used in calibrating dosimeters for use in brachytherapy since the absorbed dose to water can be determined with high accuracy in such beams using calibrated ion chambers and standard dosimetry protocols. In addition to any differences in mass-energy absorption properties between water and detector, variations in radiation yield (detector response) with radiation quality, caused by differences in the density of ionization in the energy imparted (LET), may exist. Knowledge of an eventual deviation in detector response with photon energy is important for attaining high accuracy in measured brachytherapy dose distributions. Methods: Lithium formate EPR dosimeters were irradiated to known levels of air kerma in 25-250 kV x-ray beams and in {sup 137}Cs and {sup 60}Co beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free in air into values of mean absorbed dose to the detectors were made using EGSnrc MC simulations and x-ray energy spectra measured or calculated for the actual beams. The signals from the detectors were measured using EPR spectrometry. Detector response (the EPR signal per mean absorbed dose to the detector) relative to that for {sup 60}Co was determined for each beam quality. Results: Significant decreases in the relative response ranging from 5% to 6% were seen for x-ray beams at tube voltages {<=}180 kV. No significant reduction in the relative response was seen for {sup 137}Cs and 250 kV x rays. Conclusions: When calibrated in {sup 60}Co or MV photon beams, corrections for the photon energy dependence of detector response are needed to achieve the highest accuracy when using lithium formate EPR dosimeters for measuring absorbed doses around brachytherapy sources emitting photons in the energy range of 20-150 keV such as {sup 169}Yb and electronic sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shock spectra applications to a class of multiple degree-of-freedom structures system

The demand on safety performance of launching structure and equipment system from impulsive excitations necessitates a study which predicts the maximum response of the system as well as the maximum stresses in the system. A method to extract higher modes and frequencies for a class of multiple degree-of-freedom (MDOF) Structure system is proposed. And, along with the shock spectra derived from a linear oscillator model, a procedure to obtain upper bound solutions for maximum displacement and maximum stresses in the MDOF system is presented.

Hwang, Shoi Y.↗

Electric field enhancement in a self-assembled 2D array of silver nanospheres

We investigate the plasmonic properties of a self-assembled 2D array of Ag nanospheres (average particle diameter/inter-particle separation distance of 9/3.7 nm). The structures of the individual particles and their assemblies are characterized using high-resolution transmission electron microscopy (HR-TEM). The plasmonic response of the nanoparticle network is probed using two-photon photoemission electron microscopy (TP-PEEM). HR-TEM and TP-PEEM statistics reveal the structure and plasmonic response of the network to be homogeneous on average. This translates into a relatively uniform surface-enhanced Raman scattering (SERS) response from biphenyl,4-4{sup ′}-dithiol (BPDT) molecules adsorbed onto different sites of the network. Reproducible, bright, and low-background SERS spectra are recorded and assigned on the basis of density functional theory calculations in which BPDT is chemisorbed onto the vertex of a finite tetrahedral Ag cluster consisting of 20 Ag atoms. A notable agreement between experiment and theory allows us to rigorously account for the observable vibrational states of BPDT in the ∼200–2200 cm{sup −1} region of the spectrum. Finite difference time domain simulations further reveal that physical enhancement factors on the order of 10{sup 6} are attainable at the nanogaps formed between the silver nanospheres in the 2D array. Combined with modest chemical enhancement factors, this study paves the way for reproducible single molecule signals from an easily self-assembled SERS substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy spectra of cosmic ray nuclei: 4z26 and .3E2 GeV/amu

Energy spectra of cosmic ray nuclei in the charge range 5 is less than or equal to z less than or equal to 26 have been derived from the response of an acrylic plastic Cerenkov detector. Data were obtained using a balloon borne detector and cover the energy range 320 is approximately less than e approximately less than 2200 MeV. amu. Spectra are derived from a formal deconvolution using the method of Lezniak (1975). Relative spectra of different elements are compared by observing charge ratios. Secondary primary ratios are observed to decrease with increasing energy, consistent with the effect previously observed at higher energy. Primary to primary ratios are constant for 6 is less than or equal to z less than or equal to 26 and 14 is less than or equal to z less than or equal to 26 but vary for 10 is less than or equal to z less than or equal to 14. This data is found to be consistent with existing data where comparable and lends strong support ot the idea of two separate source populations contributing to the cosmic ray composition.

Maehl, R. C.↗

Determining the structure of tetragonal Y{sub 2}WO{sub 6} and the site occupation of Eu{sup 3+} dopant

The compound Y{sub 2}WO{sub 6} is prepared by solid state reaction at 750 {sup o}C using sodium chloride as mineralizer. Its structure is solved by ab-initio methods from X-ray powder diffraction data. This low temperature phase of yttrium tungstate crystallizes in tetragonal space group P4/nmm (No. 129), Z=2, a=5.2596(2) A, c=8.4158(4) A. The tungsten atoms in the structure adopt an unusual [WO{sub 6}] distorted cubes coordination, connecting [YO{sub 6}] distorted cubes with oxygen vacancies at the O{sub 2} layers while other yttrium ions Y{sub 2} form [YO{sub 8}] cube coordination. Y{sup 3+} ions occupy two crystallographic sites of 2c (C{sub 4v} symmetry) and 2a (D{sub 2d} symmetry) in the Y{sub 2}WO{sub 6} host lattice. With Eu{sup 3+} ions doped, the high resolution emission spectrum of Y{sub 2}WO{sub 6}:Eu{sup 3+} suggests that Eu{sup 3+} partly substituted for Y{sup 3+} in these two sites. The result of the Rietveld structure refinement shows that the Eu{sup 3+} dopants preferentially enter the 2a site. The uniform cube coordination environment of Eu{sup 3+} ions with the identical eight Eu-O bond lengths is proposed to be responsible for the intense excitation of long wavelength ultraviolet at 466-535 nm. -- Graphical abstract: The excitation and emission spectra of Y{sub 2}WO{sub 6}:Eu{sup 3+} indicates the effect of long wavelength-excited property, which is ascribed to the cube coordination environment of Eu{sup 3+} ions with the uniform Eu-O bond length. Display Omitted Research highlights: Y{sub 2}WO{sub 6} is prepared using sodium chloride as mineralizer. The structure of the compound Y{sub 2}WO{sub 6} is solved by ab-initio methods. The site occupation of Eu{sup 3+} is determined. The cube coordination of Eu{sup 3+} ions is responsible for the long wavelength excitation.

36 MATERIALS SCIENCE↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excited State and Non-linear Optical Properties of NIR Absorbing β-Thiophene-Fused BF{sub 2}-Azadipyrromethene Dyes—Computational Investigation

Density functional theory and time-dependent density functional theory computations were used to understand the electronic and photophysical parameters of NIR β-thiophene-fused BF{sub 2}-azadipyrromethene dyes. The computed data are in good agreement with those obtained experimentally and they provide insights into the origin of red shifted optical spectra compared to the parent aza-BODIPY, low Stokes shift, non-linear optical responses and quantitative description of the singlet–triplet energy gap. The resultant decrease in the HOMO − LUMO energy gap is responsible for the red shift. The possible use as non-linear optical materials is supported by large enhancement in the non-linear optical properties. On the basis of vertical triplet energies, their possible potential therapeutic use as a photosensitizer in photodynamic therapy is proposed. The singlet–triplet energetic gaps suggest that the β-thiophene-fused BF{sub 2}-azadipyrromethene dyes can act as a sensitizer to produce an efficient generation of singlet oxygen. Their optimal use as an efficient singlet fission materials has been proposed on the basis of excitation energies in the ground, lowest singlet and triplet excited states.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray Transient Absorption Studies of Exciton Self-Trapping

Here, we present optical pump/X-ray absorption probe studies to probe changes in electronic distribution and local structure upon formation of a self-trapped exciton. The experiments were carried out on the mixed-valence halide-bridged transition metal linear chain charge density wave material [Pt(en 2 )][Pt(en 2 )Cl 2 ]·(ClO 4 ) 4 . Photoinduced changes in the Pt L III XANES spectrum were measured on a picosecond time scale following generation of excitons via optical excitation of the intervalence charge transfer transition. Ab initio FEFF9 modeling of the spectra and the associated angular momentum projected density of states was used to interpret the response. We find photoinduced changes reflecting electronic redistribution and local lattice distortions that correspond to strong localization of the self-trapped state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transition-Metal-Related Quantum Emitters in Wurtzite AlN and GaN

Transition-metal centers exhibit a paramagnetic ground state in wide-bandgap semiconductors and are promising for nanophotonics and quantum information processing. Specifically, there is a growing interest in discovering prominent paramagnetic spin defects that can be manipulated using optical methods. Here, we investigate the electronic structure and magneto-optical properties of Cr and Mn substitutional centers in wurtzite AlN and GaN. We use state-of-the-art hybrid density functional theory calculations to determine level structure, stability, optical signatures, and magnetic properties of these centers. The excitation energies are calculated using the constrained occupation approach and rigorously verified with the complete active space configuration interaction approach. Our simulations of the photoluminescence spectra indicate that $Cr$$^{1+}_{Al}$ in AlN and $Cr$$^{1+}_{Ga}$ in GaN are responsible for the observed narrow quantum emission near 1.2 eV. We compute the zero-field splitting (ZFS) parameters and outline an optical spin polarization protocol for $Cr$$^{1+}_{Al}$ and $Cr$$^{1+}_{Ga}$. Our results demonstrate that these centers are promising candidates for spin qubits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel method for modeling the neutron time of flight detector response in current mode to inertial confinement fusion experiments (invited)

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode for inertial confinement fusion experiments has been applied to the on-axis nTOF detectors located in the basement of the Z-Facility. It will be shown that this method can identify sources of neutron scattering, and is useful for predicting detector responses in future experimental configurations, and for identifying potential sources of neutron scattering when experimental set-ups change. This method can also provide insight on how much broadening neutron scattering contributes to the primary signals, which is then subtracted from them. Detector time responses are deconvolved from the signals, allowing a transformation from dN/dt to dN/dE, extracting neutron spectra at each detector location; these spectra are proportional to the absolute yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational prediction of dielectric breakdown strength of a transformer paper in oil with uncertainty quantification

The determination of the dielectric breakdown strengths of microstructurally heterogeneous materials has been a primarily experimental endeavor. We report the development of a microstructure-level model for computationally predicting the breakdown strength and analyzing the interactions between electromagnetic pulses (EMP) and the constituents in a composite of cellulose-based paper and mineral oil found in electrical transformers. The model allows explicit simulation of the material breakdown process by tracking the transition of dielectric constituents from non-conductive to conductive states. The focus is on the electric fields induced in the materials and the overall conditions for dielectric breakdown (defined as the onset of avalanche) caused by the electric field induced in the composite. Responses to three distinct pulse shapes, i.e., Steep Front (SF), Lightning (L), and AC with spectra spanning 60–9 × 105 Hz are considered. It is found that the breakdown strength of the material is significantly affected by microstructure heterogeneities, the spatial variations of the constituent properties, and the pulse shapes. A probabilistic characterization of the breakdown strength is computationally obtained and compared with experimental measurements. Although one particular material is analyzed, the model and approach are applicable to other heterogeneous materials as well.

breakdowns↗

Interference in above-threshold-ionization electron distributions from molecules

We present quantum-mechanical studies on above-threshold ionization of molecular ions in two and three dimensions. The momentum distributions show signatures of interfering emissions from the molecular centers. These structures deviate from a simple double-slit model that ignores the electron-ion interaction, but they are reproduced by an eikonal model. Such distortions of the interference pattern are partly responsible for the absence of clear interference patterns in the angle-integrated electron energy spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Paraelastic Two-Dimensional Materials

We study the elastic energy landscape of two-dimensional tin oxide (SnO) monolayers and demonstrate a transition temperature of Tc=8.5±1.8K using ab initio molecular dynamics (MD) that is close to the value of the elastic energy barrier J derived from T=0K density functional theory calculations. The power spectra of the velocity autocorrelation throughout the MD evolution permit identifying soft phonon modes likely responsible for the structural transformation. The mean atomic displacements obtained from a Bose-Einstein occupation of the phonon modes suggest the existence of a quantum paraelastic phase that could be tuned with charge doping: SnO monolayers could be 2D quantum paraelastic materials with a charge-tunable quantum phase transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Empirical beam hardening correction (EBHC) for CT

Purpose: Due to x-ray beam polychromaticity and scattered radiation, attenuation measurements tend to be underestimated. Cupping and beam hardening artifacts become apparent in the reconstructed CT images. If only one material such as water, for example, is present, these artifacts can be reduced by precorrecting the rawdata. Higher order beam hardening artifacts, as they result when a mixture of materials such as water and bone, or water and bone and iodine is present, require an iterative beam hardening correction where the image is segmented into different materials and those are forward projected to obtain new rawdata. Typically, the forward projection must correctly model the beam polychromaticity and account for all physical effects, including the energy dependence of the assumed materials in the patient, the detector response, and others. We propose a new algorithm that does not require any knowledge about spectra or attenuation coefficients and that does not need to be calibrated. The proposed method corrects beam hardening in single energy CT data. Methods: The only a priori knowledge entering EBHC is the segmentation of the object into different materials. Materials other than water are segmented from the original image, e.g., by using simple thresholding. Then, a (monochromatic) forward projection of these other materials is performed. The measured rawdata and the forward projected material-specific rawdata are monomially combined (e.g., multiplied or squared) and reconstructed to yield a set of correction volumes. These are then linearly combined and added to the original volume. The combination weights are determined to maximize the flatness of the new and corrected volume. EBHC is evaluated using data acquired with a modern cone-beam dual-source spiral CT scanner (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany), with a modern dual-source micro-CT scanner (TomoScope Synergy Twin, CT Imaging GmbH, Erlangen, Germany), and with a modern C-arm CT scanner (Axiom Artis dTA, Siemens Healthcare, Forchheim, Germany). A large variety of phantom, small animal, and patient data were used to demonstrate the data and system independence of EBHC. Results: Although no physics apart from the initial segmentation procedure enter the correction process, beam hardening artifacts were significantly reduced by EBHC. The image quality for clinical CT, micro-CT, and C-arm CT was highly improved. Only in the case of C-arm CT, where high scatter levels and calibration errors occur, the relative improvement was smaller. Conclusions: The empirical beam hardening correction is an interesting alternative to conventional iterative higher order beam hardening correction algorithms. It does not tend to over- or undercorrect the data. Apart from the segmentation step, EBHC does not require assumptions on the spectra or on the type of material involved. Potentially, it can therefore be applied to any CT image.

60 APPLIED LIFE SCIENCES↗

Trace organic impurities in gaseous helium

A program to determine trace organic impurities present in helium has been initiated. The impurities were concentrated in a cryogenic trap to permit detection and identification by a gas chromatographic-mass spectrometric technique. Gaseous helium (GHe) exhibited 63 GC flame ionization response peaks. Relative GC peak heights and identifications of 25 major impurities by their mass spectra are given. As an aid to further investigation, identities are proposed for 16 other components, and their mass spectra are given.

Schehl, T. A.↗

A model for microwave intensity propagation in an inhomogeneous medium

A combined analytic and phenomenological approach, utilizing Maxwell's equations in the Born approximation with radiative transfer theory, is used to describe the propagation of microwave intensity in a scattering medium characterized by three-dimensional random fluctuations in refractive index, as well as nonrandom variations in permittivity, temperature, and loss. This approach yields microwave intensities as a function of polarization, direction, and position. Numerical techniques are presented to solve the transport equations, which include cases of spatially varying coefficients, and highly peaked phase functions. Some computed results illustrating the behavior of microwave intensity in various media are presented. Included are the angular and frequency spectra of thermal emission from semi-infinite media, and the diffuse transmission and reflection response of a scattering layer. The effects of scatterer geometry and scale sizes; correlation function; and gradients in temperature, loss, and scattering parameters are also demonstrated. This model should be particularly useful in interpreting active and passive remote sensing data.

Fisher, A. D.↗

Velocity profiles of the 2.1 micron H2 emission line in the Orion molecular cloud

Spectra of the H2 nu = 1-0 S(1) emission line in Orion, observed at various positions with a resolution of 20 km/s, are presented. The intrinsic full width at half-maximum of the line ranges from 18 to 58 km/s over the observed positions. Analysis of the line profiles shows that the emitting gas is probably expanding from a region near the BN and KL infrared sources at velocities typically of 40 km/s but as high as 100 km/s, and that it is associated with the source of the broad lines seen in the spectra of many other molecules. Strong constraints are placed on models of the physical processes responsible for the broad emission lines.

Nadeau, D.↗