Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Challenges of Remote Handling in Windowless Hot Cells - 18341

Facilities such as nuclear power stations and neutron sources produce radioactive waste, which must be handled in shielded containment chambers [hot cells]. Traditionally these hot cells are built with lead glass windows to allow direct observation by operators, however, as the complexity and size of handling operations increases, the restrictions imposed by such windows becomes problematic. For the International Thermonuclear Experimental Reactor [ITER] under construction in the South of France and the European Spallation Source [ESS] under construction in Lund, Sweden the hot cell must be capable of processing large, activated and contaminated components, requiring the dexterous tele-manipulation of high dose payloads in the cell. Using lead glass windows would severely restrict the operational envelope within the cell to the volumes directly in front of the windows. This places unreasonable constraints on the types of handling operations that can be carried out. Conversely, a windowless configuration is much more flexible and maximises the operational space for robotic manipulators. Windowless hot cells do however introduce their own challenges. This paper examines the difficulties introduced by lack of direct sight and describes solutions to overcome them. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acceleration Techniques using ADVANTG for the MDF Design and Optimization

The Spallation Neutron Source (SNS) facility at Oak Ridge National Laboratory (ORNL) is implementing a Moderator Demonstration Facility (MDF) to demonstrate the performance characteristics of advanced moderators central to the Second Target Station (STS) for SNS. The MDF will provide a small, short-pulsed neutron source for slow neutron production in which we intend to easily and quickly change from one moderator concept to another, characterizing the performance of each moderator in a reproducible and consistent fashion. The MDF will be unique and innovative amongst the world's moderator test facilities in that it will be intended to be very prototypic in terms of 'moderator illumination' - the spatial variation of the neutron flux entering the moderator itself - as well as capable of testing so-called high-brightness moderators in a wing configuration. During the design phase of the MDF, the Monte Carlo N-Particle transport code MCNPX v.2.7.0 is being used as the primary tool for the neutronic analysis of the facility and characterization of the moderator performance. The Automated Variance Reduction Generator (ADVANTG) code is being utilized to accelerate the MCNPX calculations. The ADVANTG code generates space- and energy-dependent weight window parameters for a successive MCNP run by calculating the adjoint flux with the Denovo discrete ordinates code based on the user defined MCNP tally. We have tested various strategies using ADVANTG to generate weight window parameters to efficiently calculate detailed moderator performance. Using point detector response functions for weight window parameter optimization with ADVANTG did not work well for improving the efficiency of Monte Carlo calculations of neutron emission into beam lines. However, using cell fluxes of the area of highest contributions to the point detector for the variance reduction parameter analysis worked very well and improved the FOM of the calculation of neutron emission into a beamline by a factor of 50 over the unbiased case. (authors)

42 ENGINEERING↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmarking of the MCNPX predictions of the neutron time-emission spectra at LANSCE - 25332

We currently operate Mark-III generation of the spallation neutron target-moderator-reflector-shield (TMRS) assembly at the Manuel Lujan Jr. Neutron Scattering Center of the Los Alamos Neutron Science Center (LANSCE). Mark-III is scheduled for replacement with the next-generation TMRS Mark-IV in 2020. Mark-IV enhances the neutronic performance in the eV-MeV energy range by increasing intensity and improving energy resolution. The increased eV-MeV neutron flux, together with the elevated gamma-ray background, has implications for the radiation shielding of the neutron flight paths and scientific instruments. To update the shielding design, we need to maintain a thoroughly benchmarked MCNPX model of the entire TMRS assembly. In this article we use our detailed MCNPX model of Mark-III to calculate the neutron time-emission spectra. With these spectra we generate the resolution function for SAMMY calculations of capture cross section in {sup 197}Au in the resonance region between 70 eV and 1 keV. We compare the calculated data with the experimental data measured with the DANCE instrument using the neutron time-of-flight technique. We show that our current model predicts measurements accurately and thus provides a solid base for developing the radiation shielding design of the new TMRS assembly. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Shielding design for the LANSCE/WNR neutron flight paths - 25334

The shielding surrounding the spallation target and the neutron flight paths at the Los Alamos Neutron Science Center Weapons Neutron Research facility is simulated using a detailed MCNPX Monte Carlo model to determine neutron and γ-ray backgrounds in the experimental areas. In some cases the shielding needs to be modified depending on the requirements of planned experiments. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Dose rate verification for SNS spent structures - 25433

Residual dose rate measurements were conducted on two Spallation Neutron Source spent structures, target vessel no. 13 and proton beam window no. 5, after extraction from their service locations. These measurements were used to verify calculation methods for radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation. Neutronics analyses for predicting residual dose rates were carried out using complex and rigorous geometric models of the structures and their surroundings. Calculational results were analyzed and compared to the measured dose rates. (authors)

43 PARTICLE ACCELERATORS↗

Shielding maze design for Line C tunnel at LANSCE - 25456

The Los Alamos Neutron Science Center (LANSCE) is a major experimental facility at Los Alamos National Laboratory. The LANSCE linear accelerator (linac) supplies proton beams to five experimental areas simultaneously. The Isotope Production Facility (IPF) utilizes a 100-MeV beam after the first stage of acceleration, all other facilities use proton beams at 800 MeV. However, the facility can support sole-use experiments at 200-600 MeV proton beam energies. There are three spallation neutron sources providing neutrons in different energy regimes: Weapons Neutron Research (WNR), Lujan Neutron Scattering Center (Lujan Center) and the Ultra Cold Neutron source (UCN). The proton radiography (pRAD) facility utilizes the energetic proton beam for imaging and tomography directly. The beam to pRAD and UCN facilities is delivered via line X that splits into line C (pRAD) and line B (UCN). Due to engineering access controls it is impossible to deliver beam to UCN while the pRAD facility is occupied. The goal of our project was to design a shielding maze arrangement for line C to allow for simultaneous beam delivery to UCN while pRAD area (dome) is occupied. (authors)

43 PARTICLE ACCELERATORS↗

Activation analysis of the concrete in the Fleurus cyclotron facility - 25604

The purpose of this paper is to discuss the approach and the results of a recent activation analysis concerning a cyclotron facility located in Fleurus, Belgium, where isotopes of medical applications were produced by irradiating either solid (Tl) or gaseous targets (Xe) with 20-30 MeV proton beams. This paper discusses the choice of the intra-nuclear cascade model implemented in MCNP/X to correctly simulate the spallation reactions of the protons in the target, since no nuclear data are available for the isotopes of interest. TENDL nuclear data library, which is based on the models of the nuclear code system TALYS, plays a key role in the selection of the model. The neutron flux distribution throughout the installation and the activation rates in the concrete walls are then calculated with the help of a comprehensive MCNPX model of the facility. The estimated activities are in good agreement with the measurements taken in 2017 in the frame of the ongoing decommissioning of this facility. (authors)

43 PARTICLE ACCELERATORS↗

Monte Carlo neutronics analysis of the SNS STS monolith - 25684

Neutronics analysis for the Oak Ridge National Laboratory's Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides ∼peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design. (authors)

43 PARTICLE ACCELERATORS↗

Analysis of Archived Prompt Pulse Data from the SNS HYSPEC Instrument - Paper 68

This is an investigation by the Neutronics team at the Spallation Neutron Source (SNS) to understand the Hybrid-Spectrometer (HYSPEC) pulsed background problem and ultimately lend qualitative insight toward future shielding considerations. The archived user data from HYSPEC was accessed and manipulated via Mantidplot. Algorithms have been written to identify the background feature, or 'prompt pulse', in these data files and how it fluctuates as a function of time. Correlations between these fluctuations and external/internal physical changes are being analyzed in an attempt to model the behavior of the pulsed background in the SNS target building. Understanding the contributing factors of the background may help mitigate current effects as well as potential effects in future target facilities. This information is initially being used to indicate how the local shielding arrangements and general geometry of the target building and/or greater facility affect the prompt pulse as received by HYSPEC. Additionally, this better understanding of the pulsed background will continue to help our team lend increasingly accurate advice concerning future shielding improvements, minimization of prompt pulse features in the HYSPEC data, other inelastic instruments in the current target facility and suggestions for second target station planning. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties).To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Design and Optimization of Large Accelerator Systems through High-Fidelity Electromagnetic Simulations

SciDAC1, with its support for the 'Advanced Computing for 21st Century Accelerator Science and Technology' (AST) project, witnessed dramatic advances in electromagnetic (EM) simulations for the design and optimization of important accelerators across the Office of Science. In SciDAC2, EM simulations continue to play an important role in the 'Community Petascale Project for Accelerator Science and Simulation' (ComPASS), through close collaborations with SciDAC CETs/Institutes in computational science. Existing codes will be improved and new multi-physics tools will be developed to model large accelerator systems with unprecedented realism and high accuracy using computing resources at petascale. These tools aim at targeting the most challenging problems facing the ComPASS project. Supported by advances in computational science research, they have been successfully applied to the International Linear Collider (ILC) and the Large Hadron Collider (LHC) in High Energy Physics (HEP), the JLab 12-GeV Upgrade in Nuclear Physics (NP), as well as the Spallation Neutron Source (SNS) and the Linac Coherent Light Source (LCLS) in Basic Energy Sciences (BES).

43 PARTICLE ACCELERATORS↗

Next Generation IGBT Switch Plate Development for the SNS High Voltage Converter Modulator

The RF source High Voltage Converter Modulator (HVCM) systems installed on the Spallation Neutron Source (SNS) have operated well in excess of 200,000 hours, during which time numerous failures have occurred. An improved Insulated Gate Bipolar Transistor (IGBT) switch plate is under development to help mitigate these failures. The new design incorporates two significant improvements. The IGBTs are upgraded to 4500 V, 1200 A, press-pack devices, which increase the voltage margin, facilitate better cooling, and eliminate explosive disassembly of the package in the event of device failure. The upgrade to an advanced IGBT gate drive circuit decreases switching losses and improves fault-condition response. The upgrade design and development status will be presented.

43 PARTICLE ACCELERATORS↗

Redesign of the SNS Modulator H-Bridge for Utilization of Press-Pack IGBTs

The power conversion group at SLAC is currently redesigning the H-bridge switch plates of the High Voltage Converter Modulators at the Spallation Neutron Source. This integral part to the modulator operation has been indentified as a source of several modulator faults and potentially limits reliability with pulse width modulation operation. This paper is a presentation of the design and implementation of a redesigned switch plate based upon press-pack IGBTs.

43 PARTICLE ACCELERATORS↗

Prospects for using neutrons to probe nuclear magnetic resonance signal

The prospect of neutron spectrometers with magnetic fields up to 40 T makes neutron measurement of the nuclear Zeeman splitting feasible. The Zeeman splitting is observed by a neutron spectrometer as an incoherent line with an energy transfer equal to the Zeeman energy. This energy scale is small enough that fields around 15 T are required to sufficiently separate this line from other incoherent processes. Once the Zeeman splitting is observed, a perturbation of the system is required to enable measurement of the nuclear spin relaxation time; the physical quantity measured in a Nuclear Magnetic Resonance experiment. The proposed perturbation is a pulsed field of 10 T. The relaxation of the Zeeman splitting back to the 15 T condition is then recorded as a function of time. The resultant data is the aforementioned measure of the relaxation time. This contribution will describe the requirements for the magnet and neutron spectrometer on a spallation source. These requirements will be illustrated by calculations for an H2O sample. The advantages of using this approach, as compared to decay from complete polarization at low temperatures, will be discussed too.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNS-NSTG Collaborative Software Development

The Spallation Neutron Source (SNS) and the Neutron Science TeraGrid Gateway (NSTG) are collaborating on software development. SNS at Oak Ridge National Laboratory is a world center for materials research with neutron scattering. NSTG connects large neutron science instrument facilities with the cyber infrastructure of the TeraGrid. The TeraGrid is a network of high performance computers supported by the US National Science Foundation. There are eleven partner facilities with over a petaflop of peak computing performance, 136,740 CPU-cores, and sixty petabytes of long-term storage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical simulations of stripping effects in high-intensity hydrogen ion linacs

Numerical simulations of H{sup -} stripping losses from blackbody radiation, electromagnetic fields, and residual gas have been implemented into the beam dynamics code TRACK. Estimates of the stripping losses along two high-intensity H{sup -} linacs are presented: the Spallation Neutron Source linac currently being operated at Oak Ridge National Laboratory and an 8 GeV superconducting linac currently being designed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Multi-Cell Reduced-Beta Elliptical Cavities for a Proton Linac

A superconducting cavity has been designed for acceleration of particles traveling at 81% the speed of light ({beta} = 0.81). The application of interest is an 8 GeV proton linac proposed for a Fermilab upgrade; at present, the cavity is to be used from 420 MeV to 1.3 GeV. The cavity is similar to the 805 MHz high-{beta} cavity developed for the Spallation Neutron Source Linac, but the resonant frequency (1.3 GHz) and beam tube diameter (78 mm) are the same as for the {beta} = 1 cavities developed for the TESLA Test Facility. Four single-cell prototype cavities have been fabricated and tested. Two multi-cell prototypes have also been fabricated, but they have not yet been tested. The original concept was for an 8-cell cavity, but the final design and prototyping was done for 7-cells. An 11-cell cavity was proposed recently to allow the cryomodules for the {beta} = 0.81 cavity and downstream 9-cell {beta} = 1 cavities to be identical. The choice of number of cells per cavity affects the linac design in several ways. The impact of the number of cells in the 8 GeV linac design will be explored in this paper. Beam dynamics simulations from the ANL code TRACK will be presented.

43 PARTICLE ACCELERATORS↗