Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Electron diffraction study of the structural features of kaolinites

The structural variations of kaolinites have been investigated based on oblique-texture electron diffraction patterns. The features of manifestation of the 2D lattice of kaolinite layers in the geometry of the 20l and 13l reflections have been revealed. The manifestation of violations in the regular alternation of layers in kaolinites in the diffraction patterns has been analyzed using a numerical simulation of the diffraction profiles along the first (02l, 11l) and second (20l, 13l) ellipses of oblique-texture electron diffraction patterns. The simulation was performed for finite sequences of ten layers using the statistical Markov model in the quasihomogeneous approximation. It is shown that oblique-texture electron diffraction patterns can be used to reveal the coexistence of two phases with different structural perfections and particle morphologies in kaolinite samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overview of the experiments performed with Russian claddings at MTA EK

The mechanical and corrosion behavior of the Russian-type zirconium cladding alloy E110, predominantly used in VVERs, has been investigated for many decades. The recent commercialization of a new alloy E110G, produced on a sponge zirconium basis, gave the opportunity to compare the mechanical properties of the old E110 and the new E110G fuel claddings. The mechanical experiments performed with samples from both claddings in MTA EK including axial and tangential (ring) tensile tests at 20, 150 and 300 Celsius degrees. The chosen geometries for the tests were modelled using finite element method. Due to the anisotropy of the cladding tubes the axial yield strength was 6% higher than the tangential. The yield strength of the E110G alloy was 12% higher than for the E110 claddings at ambient temperature, but this difference decreased to 5% at 300 C. degrees. Some samples underwent chemical or thermal treatments and the effects of these were evaluated. These treatments were slight oxidation in steam at 800 C. degrees up to 3 ECR%, hydridation at 600 C. degrees up to 400 ppm, and heat treatment in argon atmosphere at temperatures between 600 and 1000 C. degrees. The results confirm that the heat treatment has more significant effect on the yield strength of the claddings than the chemical treatments. While the yield strength of the oxidized samples was slightly higher, when combined with the data from the heat treatment at 800 C. degrees, the oxidation itself seems to have lowered the yield strength as the thickness of the metal decreased. The hydridation of the cladding samples did not change the yield strength and the samples remained ductile even at room temperature. The thermo-mechanical creep of the two cladding alloys was also investigated. Biaxial and uniaxial creep experiments were performed with 100 mm long cladding tubes. In the biaxial test, samples of both alloys were pressurized with argon to 5, 7.5 and 10 MPa at 500 C. degrees and the test lasted till the depressurization of the tubes. The uniaxial creep was measured at 300 and 500 C. degrees in the axial direction and constant stress was applied using weights. This stress was 14.8 and 27.7 MPa at 300 C. degrees and 3.7 and 6.5 MPa at 500 C. degrees. The elongation and diametrical change of the samples were measured using different methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Elastic anisotropy of ferromagnesian post-perovskite in Earth's D" layer

We report experimental observation of a sizable elastic anisotropy in a polycrystalline sample of ferromagnesian silicate in post-perovskite (ppv) structure. Using a novel composite X-ray transparent gasket to contain and synthesize ppv in a panoramic diamond-anvil cell along with oblique X-ray diffraction geometry, we observed the anisotropic lattice strain and {l_brace}1 0 0{r_brace} or {l_brace}1 1 0{r_brace} slip-plane texture in the sample at 140 GPa. We deduced the elasticity tensor (c{sub ij}), orientation-dependent compressional wave velocities, polarization-dependent shear-wave velocities, and the velocity anisotropy of the silicate ppv. Our results are consistent with calculations and indicate that with sufficient preferred orientation, the elastic anisotropy of this phase can produce large shear-wave splitting.

36 MATERIALS SCIENCE↗

A Versatile Hemispherical Great Area X-ray Detector for Synchrotron Radiation

This work presents an X-ray detector with fullerene C60 semi spherical geometry constituted by a set of small cylindrical proportional counter units with needles anodes, which are located in the surface of an hemispherical plastic support. The sample to be analyzed is placed on the center of the hemisphere base. The radiation may enter by one of its flanks or through the hemisphere top. The hemispherical zone that exists between the holder sample base and the proportional counters can be vacuumed, aired or filled with counter gas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Numerical simulation of cosmogenic nuclide production in lunar rocks

The production rates of cosmogenic nuclides depend on the primary cosmic-ray particles, the irradiated-body's bulk composition, size, and shape, and the sample's composition and shielding depth. Although much work has been done on some of these dependencies, more detailed studies still need to be done on others. This work describes the influence of irradiation geometry on nuclide production in lunar rocks. In most cases, computer simulations of cosmogenic nuclide production were restricted to spherical objects irradiated with a 4 pi isotropic flux (meteoroids) or in lunar core samples irradiated by a 2 pi flux incident on semi-infinite layers or cylinders of huge sizes. Many lunar samples are rocks found on top of the lunar surface. For these rocks, neither of the above-mentioned models correspond to the real conditions. We present results of our simulations of cosmogenic nuclide production in models simulating the irradiation of rocks sitting on top of the lunar surface. The Galactic Cosmic Rays (GCR) production profiles in lunar rocks were calculated using the Los Alamos 3-D Monte Carlo LAHET Code System (LCS). The irradiated object was modeled as the union of a sphere with the radius of the Moon and a small hemisphere with radii varying from 10 to 100 g/sq cm simulating the lunar rock. These calculations for the production of cosmogenic nuclides in lunar rocks by GCR particle show that there are important differences between the results obtained by commonly used geometric irradiation models and the lunar-rock models presented. The steeper GCR production profiles for a rock could help to explain the poor agreement for Be-10 in rock 68815, where slab models give GCR profiles flatter than the observed profiles.

Reedy, R. C.↗

Aeroheating Testing of the Mars Sample Return Earth Entry System with Surface Roughness

The Mars Sample Return Earth Entry System is a mission concept which would be the first NASA entry vehicle to utilize a woven thermal protection system as well as a 52.5 degree sphere-cone forebody geometry. Due to its novel design, historic experimental data sets were insufficient to validate the models used to characterize the expected aerothermal environment. A wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project in the NASA Langley 20-Inch Mach 6 Air Tunnel in order to obtain validation data. The December 2023 test entry of this campaign sought to obtain thermographic data to capture the impact of supersonic flow near woven surface roughness elements on convective heating augmentation, which was the largest remaining uncertainty in aerothermal design of the Earth Entry System. Data obtained were in family with prior results obtained on identical woven patterns without supersonic flow present at roughness elements, and it was found that this presence of supersonic flow did not have a noticeable effect on surface convective heating augmentation. Data were directly leveraged to support the NASA Mars Sample Return flight program and this data set is valuable for validating computational solutions on roughness-resolved grids.

Mars Sample Return↗

Aeroheating Testing of the Mars Sample Return Earth Entry System with Surface Roughness

The Mars Sample Return Earth Entry System is a mission concept which would be the first NASA entry vehicle to utilize a woven thermal protection system as well as a 52.5 degree sphere-cone forebody geometry. Due to its novel design, historic experimental data sets were insufficient to validate the models used to characterize the expected aerothermal environment. A wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project in the NASA Langley 20-Inch Mach 6 Air Tunnel in order to obtain validation data. The December 2023 test entry of this campaign sought to obtain thermographic data to capture the impact of supersonic flow near woven surface roughness elements on convective heating augmentation, which was the largest remaining uncertainty in aerothermal design of the Earth Entry System. Data obtained were in family with prior results obtained on identical woven patterns without supersonic flow present at roughness elements, and it was found that this presence of supersonic flow did not have a noticeable effect on surface convective heating augmentation. Data were directly leveraged to support the NASA Mars Sample Return flight program and this data set is valuable for validating computational solutions on roughness-resolved grids.

Mars Sample Return↗

PLASMA ETCHING OF A SINGLE-CELL RF CAVITY -ASYMMETRIC ELECTRONEGATIVE DISCHARGE

We are pursuing the use of environmentally friendly dry etching of SRF cavity in Ar/Cl2 discharge. We have successfully demonstrated on flat samples that in a barrel-type reactor etching rates are comparable to the wet process, such as BCP or EP. The geometry of SRF cavities made of bulk Nb defines the use of asymmetric RF discharge configuration for plasma etching. The asymmetry in the surface area of a driven and grounded electrode creates a difference in the voltage drop over the plasma sheath attached to the driven electrode and the plasma sheath attached to the cavity surface. A specially designed single cell cavity is used to study these asymmetric discharges which contain 20 sample holder holes symmetrically placed over the cell. These sample holder holes can be used for both diagnostics and sample etching purposes. The approach is to combine radially and spectrally resolved profiles of optical intensity of the discharge with direct etched surface diagnostics to obtain an optimum combination of etching rates, roughness and homogeneity in a variety of discharge types, conditions and sequences.

Upadhyay, Janardan↗

On the quantitative measurement of fracture toughness in high explosive and mock materials

Two approaches in measuring the fracture toughness of heterogeneous high explosives and their mocks are explored in this investigation. One is the global measurement according to the ASTM E 1820-06 standard, which is primarily developed for metallic materials to obtain quantitative measurement of parameters such as the stress intensity factor, the J-integral, and the crack-tip opening displacement (CTOD). The second approach is based on local measurements using digital image correlation (DIC). Detailed results and comparisons of the two strategies will be presented for the Mock 900-21, a mechanical simulant of the PBX 9501 high explosive. Cracking is the most dominant mechanical failure mechanism in high explosives (HE) and a key parameter for describing and predicting crack initiation and extension is the fracture toughness. Quantitative measurement of such material property poses challenges, and this is mainly because that the material is highly heterogeneous with a very complicated microstructure and the contrast of the mechanical properties of the constituents is also remarkably high. In this investigation, we explore two strategies in measuring the fracture toughness of heterogeneous high explosives and their mocks. The first approach is based on the global measurement according to the ASTM E 1820-06 standard, which is primarily developed for metallic materials to obtain quantitative measurement of parameters such as the stress intensity factor, the J-integral, and the crack-tip opening displacement (CTOD). However, there are difficulties in applying the ASTM standard on energetic solids that include identifying the moment of crack initiation and pinpointing exact crack length at each instant of time. The second approach is based on local measurements. We developed a technique for quantitatively identifying the location and extent of macroscopic cracks in heterogeneous high explosive and mock material. By combining such a technique with the displacement field measurement using digital image correlation (DIC), we can describe, in detail, the crack-opening displacement and crack-opening angle as function of crack length. These quantitative measurements are then combined with the fracture mechanics analysis for the determination of fracture toughness. While the ASTM standard imposes strict requirements on the specimen geometry, loading configuration, and the amount of crack growth, the strategy based on local measurement should be applicable to any sample shapes and loading conditions, thus makes it more suitable to energetic materials, where often the amount of material can be tested is the major constraint. Detailed results and comparisons of the two strategies will be presented for the Mock 900-21, a mechanical simulant of the PBX 9501 high explosive.

36 MATERIALS SCIENCE↗

A New Stochastic Modeling of 3-D Mud Drapes Inside Point Bar Sands in Meandering River Deposits

The environment of major sediments of eastern China oilfields is a meandering river where mud drapes inside point bar sand occur and are recognized as important factors for underground fluid flow and distribution of the remaining oil. The present detailed architectural analysis, and the related mud drapes' modeling inside a point bar, is practical work to enhance oil recovery. This paper illustrates a new stochastic modeling of mud drapes inside point bars. The method is a hierarchical strategy and composed of three nested steps. Firstly, the model of meandering channel bodies is established using the Fluvsim method. Each channel centerline obtained from the Fluvsim is preserved for the next simulation. Secondly, the curvature ratios of each meandering river at various positions are calculated to determine the occurrence of each point bar. The abandoned channel is used to characterize the geometry of each defined point bar. Finally, mud drapes inside each point bar are predicted through random sampling of various parameters, such as number, horizontal intervals, dip angle, and extended distance of mud drapes. A dataset, collected from a reservoir in the Shengli oilfield of China, was used to illustrate the mud drapes' building procedure proposed in this paper. The results show that the inner architectural elements of the meandering river are depicted fairly well in the model. More importantly, the high prediction precision from the cross validation of five drilled wells shows the practical value and significance of the proposed method.

42 ENGINEERING↗

Chemical controls on the propagation rate of fracture in calcite

Calcite (CaCO 3 ) is one of the most abundant minerals in the Earth’s crust, and it is susceptible to subcritical chemically-driven fracturing. Understanding chemical processes at individual fracture tips, and how they control the development of fractures and fracture networks in the subsurface, is critical for carbon and nuclear waste storage, resource extraction, and predicting earthquakes. Chemical processes controlling subcritical fracture in calcite are poorly understood. We demonstrate a novel approach to quantify the coupled chemical-mechanical effects on subcritical fracture. The calcite surface was indented using a Vickers-geometry indenter tip, which resulted in repeatable micron-scale fractures propagating from the indent. Individual indented samples were submerged in an array of aqueous fluids and an optical microscope was used to track the fracture growth in situ. The fracture propagation rate varied from 1.6 × 10 -8 m s -1 to 2.4 × 10 -10 m s -1 . The rate depended on the type of aqueous ligand present, and did not correlate with the measured dissolution rate of calcite or trends in zeta-potential. We postulate that chemical complexation at the fracture tip in calcite controls the growth of subcritical fracture. Previous studies indirectly pointed to the zeta-potential being the most critical factor, while our work indicates that variation in the zeta-potential has a secondary effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Science at Modern Light Sources

More than 50 large x-ray and UV light sources based on high-energy electron accelerators are in operation around the world, serving a scientific community numbering in the tens of thousands. These sources generate synchrotron radiation from accelerated electrons or positrons. The development of synchrotron light sources over the last 40 years has fueled an exponential increase in x-ray source brightness of more than 10 orders of magnitude. The next large advance in source potential is now underway, with the commissioning of the first x-ray Free-Electron Laser (FEL) sources. Using high-energy electron linear accelerators, these facilities produce sub-picosecond pulses of hard x-rays with peak brightness more than 10 orders of magnitude greater than current synchrotron facilities. FEL x-ray facilities will soon be operational in the US, Japan, and Germany.Research at modern light sources makes use of a wide range of experimental techniques. Many experiments are designed to study the structure of matter at the atomic scale using elastic x-ray scattering. This technique has been particularly effective for determining the structures of biological molecules, such as proteins, viruses, and drugs. Inelastic x-ray scattering, or x-ray absorption followed by emission of electrons or photons, can give information about the electronic structures of atoms, which can be used to deduce local environment information such as atomic species, bonding state, geometry of neighboring atoms, or magnetic state. For some techniques involving x-ray emission from a sample, cryogenic detectors with energy resolution at the {approx}10 eV level or better would be very helpful. Shifts in electron energy levels associated with bonding states and magnetic states are typically several eV, while the energy structure associated with Compton inelastic scattering is typically in the range of a few tens of eV. Current energy-resolving detectors used at synchrotron light sources are hampered by either poor energy resolution ({approx}100 eV for solid state detectors), or very poor angular acceptance (10{sup -3} sr or worse for grating and crystal analyzer detectors).Photon detectors at synchrotron light sources can be presented with very high signal count rates. At the new FEL sources, this issue will be especially acute, since each sub-picosecond pulse will deliver the flux produced in one second by a synchrotron. This invites the use of multiple small detectors to spread the load. The ideal energy-resolving detector for x-ray science at modern light sources would combine eV-level energy resolution, 100-{mu}m pixel size, and a low per-pixel cost allowing several megapixels to be deployed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Short wavelength turbulence generated by shear in the quiescent H-mode edge on DIII–D

A region of turbulence with large radial wavenumber (k{sub r}ρ{sub s}>1) is found in the high-shear portion of the plasma edge in Quiescent H-mode (QH-mode) on DIII–D using the Phase Contrast Imaging (PCI) diagnostic. At its peak outside the minimum of the E{sub r} well, the turbulence exhibits large amplitude n{sup ~}/n∼40%, with large radial wavenumber |k{sup ¯}{sub r}/k{sup ¯}{sub θ}|∼11 and short radial correlation length L{sub r}/ρ{sub i}∼0.2. The turbulence inside the E{sub r} well minimum is characterized by the opposite sign in radial wavenumber from that of turbulence outside the minimum, consistent with the expected effects of velocity shear. The PCI diagnostic provides a line-integrated measurement of density fluctuations, so data are taken during a scan of plasma position at constant parameters to allow the PCI to sample a range in k{sub r}/k{sub θ}. Analysis of the Doppler shift and plasma geometry allows the turbulence to be localized to a narrow region 3 mm inside the last closed flux surface, outside the minimum of the E{sub r} well. The turbulence amplitude and radial wavenumber and correlation length are determined by fitting the PCI results with a simple non-isotropic turbulence model with two regions of turbulence. These PCI observations, made in QH-mode, are qualitatively similar to those made in standard edge localized modes (ELM)-free H-mode and between ELMs, suggesting a similar role for large k{sub r} turbulence there.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward broad-band x-ray detected ferromagnetic resonance in longitudinal geometry

An ultrahigh-vacuum-compatible setup for broad-band X-ray detected ferromagnetic resonance (XFMR) in longitudinal geometry is introduced which relies on a low-power, continuous-wave excitation of the ferromagnetic sample. A simultaneous detection of the conventional ferromagnetic resonance via measuring the reflected microwave power and the XFMR signal of the X-ray absorption is possible. First experiments on the Fe and Co L{sub 3}-edges of a permalloy film covered with Co nanostripes as well as the Fe and Ni K-edges of a permalloy film are presented and discussed. Two different XFMR signals are found, one of which is independent of the photon energy and therefore does not provide element-selective information. The other much weaker signal is element-selective, and the dynamic magnetic properties could be detected for Fe and Co separately. The dependence of the latter XFMR signal on the photon helicity of the synchrotron light is found to be distinct from the usual x-ray magnetic circular dichroism effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reversible migration of silver on memorized pathways in Ag-Ge{sub 40}S{sub 60} films

Reversible and reproducible formation and dissolution of silver conductive filaments are studied in Ag-photodoped thin-film Ge{sub 40}S{sub 60} subjected to electric fields. A tip-planar geometry is employed, where a conductive-atomic-force microscopy tip is the tip electrode and a silver patch is the planar electrode. We highlight an inherent “memory” effect in the amorphous chalcogenide solid-state electrolyte, in which particular silver-ion migration pathways are preserved “memorized” during writing and erasing cycles. The “memorized” pathways reflect structural changes in the photodoped chalcogenide film. Structural changes due to silver photodoping, and electrically-induced structural changes arising from silver migration, are elucidated using Raman spectroscopy. Conductive filament formation, dissolution, and electron (reduction) efficiency in a lateral device geometry are related to operation of the nano-ionic Programmable Metallization Cell memory and to newly emerging chalcogenide-based lateral geometry MEMS technologies. The methods in this work can also be used for qualitative multi-parameter sampling of metal/amorphous-chalcogenide combinations, characterizing the growth/dissolution rates, retention and endurance of fractal conductive filaments, with the aim of optimizing devices.

36 MATERIALS SCIENCE↗