Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Superresolution Diffuse Optical Imaging by Localization of Fluorescence

The multiple scattering of light presents major challenges in realizing useful in vivo imaging at tissue depths of more than about one millimeter, where many answers to health questions lie. Visible through near-infrared photons can be readily and safely detected through centimeters of tissue; however, limited information is available for image formation. One strategy for obtaining images is to model the photon transport and a simple incoherent model is the diffusion equation approximation to the Boltzmann transport equation. Such an approach provides a prediction of the mean intensity of heavily scattered light and hence provides a forward model for optimization-based computational imaging. While diffuse optical imaging methods have received substantial attention, they remain restricted in terms of resolution because of the loss of high-spatial-frequency information that is associated with the multiple scattering of photons. Consequently, only relatively large inhomogeneities, such as tumors or organs in small animals, can be effectively resolved. We introduce a superresolution imaging approach based on point localization in a diffusion framework that enables over two orders of magnitude improvement in the spatial resolution of diffuse optical imaging. The method is demonstrated experimentally by localizing a fluorescent inhomogeneity in a highly scattering slab and characterizing the localization uncertainty. The approach allows imaging through centimeters of tissue with a resolution of tens of microns, thereby enabling cells or cell clusters to be resolved. More generally, this high-resolution imaging approach could be applied with any physical transport or wave model and hence to a broad class of physical problems. Finally, paired with a suitable optical contrast mechanism, as can be realized with targeted fluorescent molecules or genetically modified animals, superresolution diffuse imaging should open alternative dimensions for in vivo applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chiral liquid phase of simple quantum magnets

We study a T=0 quantum phase transition between a quantum paramagnetic state and a magnetically ordered state for a spin S=1 XXZ Heisenberg antiferromagnet on a two-dimensional triangular lattice. The transition is induced by an easy-plane single-ion anisotropy D. At the mean-field level, the system undergoes a direct transition at a critical D=D c between a paramagnetic state at D>D c and an ordered state with broken U(1) symmetry at D c . We show that beyond mean field the phase diagram is very different and includes an intermediate, partially ordered chiral liquid phase. Specifically, we find that inside the paramagnetic phase the Ising (J z ) component of the Heisenberg exchange binds magnons into a two-particle bound state with zero total momentum and spin. This bound state condenses at D>D c , before single-particle excitations become unstable, and gives rise to a chiral liquid phase, which spontaneously breaks spatial inversion symmetry, but leaves the spin-rotational U(1) and time-reversal symmetries intact. This chiral liquid phase is characterized by a finite vector chirality without long-range dipolar magnetic order. In our analytical treatment, the chiral phase appears for arbitrarily small J z because the magnon-magnon attraction becomes singular near the single-magnon condensation transition. This phase exists in a finite range of D and transforms into the magnetically ordered state at some D c . In conclusion, we corroborate our analytic treatment with numerical density matrix renormalization group calculations.

36 MATERIALS SCIENCE↗

Tunable UV upgrade on OMEGA EP

The OMEGA EP laser has been upgraded to provide a UV wavelength-tunable beam to support the study of wavelength detuning for the mitigation of cross-beam energy transfer in direct-drive inertial confinement fusion. The beamline delivers up to 0.5 TW in pulses up to 1-ns duration (0.1 TW up to 2.5 ns), to either the OMEGA or OMEGA EP target chambers with wavelength tunable from 350.2 to 353.4 nm. The upgrade leverages the existing optical parametric amplification (OPA) system in the short-pulse front end of OMEGA EP Beamline 1 for amplification of a new tunable, narrowband fiber front end over a broad spectral range. The tunable OPA output is spatially shaped to form a round OMEGA-like beam, which is amplified in the OMEGA EP beamline, then frequency tripled and characterized using the existing OMEGA EP long-pulse infrastructure. A new 3ω beam-transport system intercepts the tunable UV beam near the OMEGA EP target chamber and image relays it to the P9 port of the OMEGA target chamber for joint shots with the OMEGA 60-beam laser. Commissioning of the tunable UV capability has been completed, and four experimental campaigns have been supported with the tunable beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths.

Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has been designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.

36 MATERIALS SCIENCE↗

Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths

Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has been designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.

36 MATERIALS SCIENCE↗

Measuring Magnetic Fields in Collisionless Experiments

Magnetic field and electron density diagnostics are critical tools in the characterization of high energy density laboratory plasmas. These plasma environments are complex and the magnetic fields and electron densities often exhibit significant spatial and temporal variation leading to significant challenges in these measurements. Even the most promising technique, Zeeman splitting, faces challenges under plasma conditions where broadening due to high density and temperature is greater than the Zeeman splitting. Here we propose and describe a diagnostic based on Zeeman broadening. The Zeeman broadening diagnostic relies on measuring the widths of multiplet components simultaneously. The method does not depend on resolved lines, but rather on measuring the difference in the widths of multiplet lines. Experiments were performed at the University of Nevada, Reno, Nevada Terawatt Facility (NTF). The Zeeman broadening diagnostic gathered visible broadened multiplet spectra from laser produced plasmas, and plasmas generated from wire-arrays driven by the Zebra z-pinch pulsed power apparatus. The laser produced plasma, created by the Leopard pulsed laser (I>1014 W/cm 2 ), evolved in an external magnetic field (B<40T) generated by current driven through a solid electrode by the Zebra current pulse. For laser produced plasmas, observation of the magnetic field radial profile showed that the external field completely diffuses into the plasma after approximately 100 ns. Further, as the plasma continues to evolve, the field profiles within the plasma develop modulations that do not map the external field profile. For the wire array experiments, radial electron density, and magnetic field, profiles were measured. Here the Zeeman splitting was not resolved and the magnetic fields were determined from the difference between the widths of the multiplet line profiles. Thus, it has been demonstrated that Zeeman broadening may be used as a magnetic field diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep Learning and Photogrammetric Reconstruction for Automated Crack Detection and Dimensional Measurement in Mining Operations

Surface crack detection and dimensional measurement at active mining sites present significant safety and operational challenges. Manual inspection methods are labor-intensive, spatially incomplete, and expose personnel to hazardous environments, while existing automated approaches have been developed primarily for concrete civil infrastructure and have not been validated on the complex, variable surfaces characteristic of mining environments. This dissertation presents an automated pipeline that integrates deep learning semantic segmentation with Structure-from-Motion photogrammetry to detect surface cracks and measure their aperture, length, and vertical displacement from standard RGB imagery acquired during routine Uncrewed Aerial Vehicle (UAV) survey operations, without requiring additional sensor hardware or manual measurement. The pipeline combines a U-Net architecture with an EfficientNet-B0 encoder, pretrained on the SDNET2018 concrete crack dataset and fine-tuned on a mining-specific dataset spanning laboratory concrete specimens, coal refuse impoundment embankments, and post-blast limestone quarry benches. Photogrammetric reconstruction is performed using COLMAP Structure-from-Motion and Multi-View Stereo, with crack segmentation masks projected into the reconstructed point cloud to enable three-dimensional vertical displacement measurement through local plane fitting and bimodal surface detection. The pipeline was validated across 36 controlled laboratory specimens at three imaging distances and four vertical displacement levels, achieving aperture measurement RMSE of 0.047 cm and R² of 0.954, and vertical displacement RMSE of 0.140 cm and R² of 0.966, against independent caliper measurements. Field application at a coal refuse impoundment in southwestern Pennsylvania detected 71 crack components across the embankment crest, with a dominant longitudinal crack exhibiting aperture values reaching 28 cm and a 95th percentile vertical displacement of 35.53 cm, consistent in magnitude and spatial distribution with simultaneously acquired LiDAR-derived estimates. Application across four post-blast limestone quarry bench datasets in California successfully characterized blast-induced fracture networks at ground sampling distances ranging from 0.59 to 1.23 cm/pixel, with detected crack geometries physically consistent with observable surface conditions at each site. The results demonstrate that deep learning-based crack detection and photogrammetric measurement can be integrated into routine UAV inspection workflows at mining sites, providing repeatable, scalable, and quantitative crack characterization across surface types, crack scales, and displacement magnitudes not previously addressed in the literature. The pipeline requires no dedicated surveying equipment beyond the UAV platforms already deployed at mine sites for survey and monitoring purposes, supporting practical adoption within existing operational workflows.

Crack detection, Dimensional Measurement↗

Thermal Conductivity Degradation in High Burnup U-Pu-Zr Fuel

Recent advancements in the characterization of irradiated U-Pu-Zr fuels have revealed complexities that challenge existing understanding of constituent redistribution. Traditionally, models have proposed three concentric regions within the fuel, each characterized by distinctive phases and porosity. However, through detailed analysis of high burnup U-Pu-Zr, we discovered the presence of four distinct constituent redistribution regions. Particularly novel is the observation of significant Pu redistribution, a previously unreported phenomenon that necessitates a reevaluation of current models. This work aims to delve deeper into these findings, seeking to correlate mesoscale measurements of thermal diffusivity and respective thermal conductivity with the phases present in each redistribution region. To achieve this objective, we employed mesoscale thermoreflectance methods using the unique, Idaho National Laboratory (INL) developed, Thermal Conductivity Microscope (TCM) at INL’s Irradiated Materials Characterization Laboratory. The TCM employs two tightly focused lasers: one for heating to generate periodic thermal waves in the substrate, and another spatially separated probe laser to detect changes in the optical reflectivity of the gold-coated substrate resulting from thermal wave diffusion. We conducted several thermal diffusivity measurements within each region of constituent redistribution of a U-19Pu-10Zr fuel pin cross section irradiated to 11 at. % burnup. The TCM measurement positions strategically aligned with transmission electron microscopy (TEM) lift-out locations previously collected from the fuel sample. Complementary microstructural analysis techniques such as optical and scanning electron microscopy (OM/SEM), electron probe microanalysis for chemical compositions, and TEM-based selective area electron diffraction (SAED) analysis for crystallographic insights into each phase were also utilized. This comprehensive approach allowed us to correlate local thermal diffusivity data with microstructural characteristics, enabling the computation of local thermal conductivity at each position. The significance of this contribution lies in its pioneering use of the TCM for ternary fuel mesoscale examination, shedding light on the previously overlooked effects of Pu redistribution on local thermal conductivity. By informing current models capturing constituent redistribution and heat transfer, our findings pave the way for more accurate predictions of metallic fuel performance. Moreover, this work sets the stage for future comparisons with similar TCM examinations on U-19Pu-10Zr fuels at ultra-low burnup, facilitating a comprehensive understanding of thermal property changes across different burnup levels. Ultimately, our study not only enriches our understanding of the thermophysical properties of individual redistribution regions within U-Pu-Zr fuel but also offers valuable insights for the design and operational parameters of proposed next-generation fast reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring Surface Phenomena Created by an Underground Chemical Explosion Using Fully Polarimetric VideoSAR

Sandia National Laboratories flew its Facility for Advanced RF and Algorithm Development X-Band (9.6-GHz center frequency), fully polarimetric synthetic aperture radar (PolSAR) in VideoSAR mode to collect complex-valued SAR imagery before, during, and after the sixth Source Physics Experiment's (SPE-6) underground explosion. The VideoSAR products generated from the data sets include "movies'' of single- and quad-polarization coherence maps, magnitude imagery, and polarimetric decompositions. Residual defocus, due to platform motion during data acquisition, was corrected with a digital elevation model-based autofocus algorithm. We generated and exploited the VideoSAR image products to characterize the surface movement effects caused by the underground explosion. Unlike seismic sensors, which measure local area seismic waves using sparse spacing and subterranean positioning, these VideoSAR products captured high-spatial resolution, 2-D, time-varying surface movement. The results from the fifth SPE (SPE-5) used single-polarimetric VideoSAR data. In this paper, we present single-polarimetric and fully polarimetric VideoSAR results while monitoring the SPE-6 underground chemical explosion. We show that fully polarimetric VideoSAR imaging provides a unique, coherent, time-varying measure of the surface expression of the SPE-6 underground chemical explosion. As a result, we include new surface characterization results from the measured PolSAR SPE-6 data via H/A/α polarimetric decomposition.

47 OTHER INSTRUMENTATION↗

Effects of optical dopants and laser wavelength on atom probe tomography analyses of borosilicate glasses

Atom probe tomography (APT) is a novel analytical microscopy method that provides three dimensional elemental mapping with sub-nanometer spatial resolution and has only recently been applied to insulating glass and ceramic samples. In this paper, we have studied the influence of the optical absorption in glass samples on APT characterization by introducing different transition metal optical dopants to a model borosilicate nuclear waste glass (international simple glass). A systematic comparison is presented of the glass optical properties and the resulting APT data quality in terms of compositional accuracy and the mass spectra quality for two APT systems: one with a green laser (532 nm, LEAP 3000X HR) and one with a UV laser (355 nm, LEAP 4000X HR). These data were also compared to the study of a more complex borosilicate glass (SON68). The results show that the analysis data quality such as compositional accuracy and total ions collected, was clearly linked to optical absorption when using a green laser, while for the UV laser optical doping aided in improving data yield but did not have a significant effect on compositional accuracy. Comparisons of data between the LEAP systems suggest that the smaller laser spot size of the LEAP 4000X HR played a more critical role for optimum performance than the optical dopants themselves. The smaller spot size resulted in more accurate composition measurements due to a reduced background level independent of the material’s optical properties.

Environmental Molecular Sciences Laboratory↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geothermal Exploration Raster Files for Utah Play Fairway Analysis

This submission contains raster files associated with several datasets that include earthquake density, Na/K geothermometers, fault density, heat flow, and gravity. Integrated together using spatial modeler tools in ArcGIS, these files can be used for play fairway analysis in regard to geothermal exploration.

15 GEOTHERMAL ENERGY↗

Type Ibn Supernovae Show Photometric Homogeneity and Spectral Diversity at Maximum Light

Type Ibn supernovae (SNe) are a small yet intriguing class of explosions whose spectra are characterized by low-velocity helium emission lines with little to no evidence for hydrogen. The prevailing theory has been that these are the core-collapse explosions of very massive stars embedded in helium-rich circumstellar material (CSM). We report optical observations of six new SNe Ibn: PTF11rfh, PTF12ldy, iPTF14aki, iPTF15ul, SN 2015G, and iPTF15akq. This brings the sample size of such objects in the literature to 22. We also report new data, including a near-infrared spectrum, on the Type Ibn SN 2015U. In order to characterize the class as a whole, we analyze the photometric and spectroscopic properties of the full Type Ibn sample. We find that, despite the expectation that CSM interaction would generate a heterogeneous set of light curves, as seen in SNe IIn, most Type Ibn light curves are quite similar in shape, declining at rates around 0.1 mag day{sup −1} during the first month after maximum light, with a few significant exceptions. Early spectra of SNe Ibn come in at least two varieties, one that shows narrow P Cygni lines and another dominated by broader emission lines, both around maximum light, which may be an indication of differences in the state of the progenitor system at the time of explosion. Alternatively, the spectral diversity could arise from viewing-angle effects or merely from a lack of early spectroscopic coverage. Together, the relative light curve homogeneity and narrow spectral features suggest that the CSM consists of a spatially confined shell of helium surrounded by a less dense extended wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the loss mechanisms in emerging water splitting photoanodes through empirical extraction of the spatial charge collection efficiency

We present that the operando quantification of surface and bulk losses is key to developing strategies for optimizing photoelectrodes and realizing high efficiency photoelectrochemical solar energy conversion systems. This is particularly true for emerging thin film semiconductors, in which photocarrier diffusion lengths, surface and bulk recombination processes, and charge separation and extraction limitations are poorly understood. Insights into mechanisms of efficiency loss can guide strategies for nanostructuring photoelectrodes, engineering interfaces, and incorporating catalysts. However, few experimental methods are available for direct characterization of dominant loss processes under photoelectrochemical operating conditions. In this work, we provide insight into the function and limitations of an emerging semiconductor photoanode, γ-Cu 3 V 2 O 8 , by quantifying the spatial collection efficiency (SCE), which is defined as the fraction of photogenerated charge carriers at each point below the surface that contributes to the measured current. Analyzing SCE profiles at different operating potentials shows that increasing the applied potential primarily acts to reduce surface recombination rather than to increase the thickness of the space charge region under the semiconductor/electrolyte interface. Comparing SCE profiles obtained with and without a sacrificial reagent allows surface losses from electronically active defect states to be distinguished from performance bottlenecks arising from slow reaction kinetics. Combining these insights promotes a complete understanding of the photoanode performance and its potential as a water splitting photoanode. More generally, application of the SCE extraction method can aid in the discovery and evaluation of new materials for solar water splitting devices by providing mechanistic details underlying photocurrent generation and loss.

14 SOLAR ENERGY↗

Massively parallel, computationally guided design of a proenzyme

Proteins have shown promise as therapeutics and diagnostics, but their effectiveness is limited by our inability to spatially target their activity. To overcome this limitation, we developed a computationally guided method to design inactive proenzymes or zymogens, which are activated through cleavage by a protease. Since proteases are differentially expressed in various tissues and disease states, including cancer, these proenzymes could be targeted to the desired microenvironment. We tested our method on the therapeutically relevant protein carboxypeptidase G2 (CPG2). We designed Pro-CPG2s that are inhibited by 80 to 98% and are partially to fully reactivatable following protease treatment. The developed methodology, with further refinements, could pave the way for routinely designing protease-activated protein-based therapeutics and diagnostics that act in a spatially controlled manner. Confining the activity of a designed protein to a specific microenvironment would have broad-ranging applications, such as enabling cell type-specific therapeutic action by enzymes while avoiding off-target effects. While many natural enzymes are synthesized as inactive zymogens that can be activated by proteolysis, it has been challenging to redesign any chosen enzyme to be similarly stimulus responsive. Here, we develop a massively parallel computational design, screening, and next-generation sequencing-based approach for proenzyme design. For a model system, we employ carboxypeptidase G2 (CPG2), a clinically approved enzyme that has applications in both the treatment of cancer and controlling drug toxicity. Detailed kinetic characterization of the most effectively designed variants shows that they are inhibited by ∼80% compared to the unmodified protein, and their activity is fully restored following incubation with site-specific proteases. Introducing disulfide bonds between the pro- and catalytic domains based on the design models increases the degree of inhibition to 98% but decreases the degree of restoration of activity by proteolysis. A selected disulfide-containing proenzyme exhibits significantly lower activity relative to the fully activated enzyme when evaluated in cell culture. Structural and thermodynamic characterization provides detailed insights into the prodomain binding and inhibition mechanisms. The described methodology is general and could enable the design of a variety of proproteins with precise spatial regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗