Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

PhytoPET, PhytoBeta and PhytoSPECT: Radioisotope Imaging Systems Being Developed for Plant Biology Research

The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility (Jefferson Lab) is developing radioisotope imaging systems designed and constructed to facilitate plant biology studies at the Duke University Phytotron. The imaging systems utilize nuclear medicine imaging methodologies used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) but designed specifically for plant biology. The range of plant shapes and the environmental conditions in plant growth chambers pose a technological challenge. Description: Jefferson Lab is collaborating with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) in the construction and operation of PhytoPET and PhytoBeta (for direct beta particle detection) for plant and/or microbe imaging. The TUNL tandem Van de Graaff accelerator (maximum terminal voltage of 10 MV) has been used to generate 11C and 13N for plant biology research. The PhytoPET and PhytoBeta have been used with 11C as a 11CO2 tracer for plant ecophysiology imaging with corn, poplar, oak and barley utilizing technologies developed for nuclear physics research and nuclear medicine. The imaging detectors are based on position sensitive photomultiplier tubes coupled to scintillators. Additionally, the collaboration is investigating a methodology using single photon emitting radioisotope tracers for imaging the distribution of molecular compounds of interest in the rhizosphere, the interface between root and soil, without disturbing the root or soil habitat. Plans are underway to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots. In addition to a description of the technology an overview will be given of the application of PhytoPET, PhytBeta and PhytoSPECT to plant biology research at Duke University. Conclusions: We have developed and used radioisotope imaging technologies based on PET and SPECT to visualize plant function in changing environments. There are many opportunities to provide radioisotope based imaging tools for plant ecophysiology imaging. Keywords: radioisotope detection, plant biology, carbon-11, accelerator produced isotopes

Weisenberger, Andrew↗

ASSEMBLY AND INITIAL RESULTS: AN ULTRA-LOW-BACKGROUND GERMANIUM CRYSTAL ARRAY FOR HIGH EFFICIENCY AND COINCIDENCE MEASUREMENTS

ABSTRACT Treaty verification, environmental surveillance, and physics experiments continue to require increased sensitivity for detecting and quantifying radionuclides of interest using gamma-ray spectrometry. This can be accomplished by establishing high detection efficiency and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gamma spectroscopy will produce an intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and useful coincidence efficiencies. The system design is optimized to accommodate filter paper samples, e.g. samples collected by the Radionuclide Aerosol Sampler/Analyzer (RASA). The system will provide high sensitivity for weak collections on atmospheric filter samples, as well as offering the potential to gather additional information from more active filters using gamma cascade coincidence detection. The instrument will also be capable of making advances in low-dose neutron activation analysis. The first of two ultra-low-background vacuum cryostats has been assembled, with a second in progress. Traditional methods for constructing ultra-low-background detectors were followed, including use of materials known to be low in radioactive contaminants, use of ultra pure reagents, clean room assembly, etc. The cryostat is constructed mainly from copper electroformed into near-final geometry at Pacific Northwest National Laboratory. Details of the detector assembly, vacuum tests, and test measurement results are presented.

ULTRA-LOW-BACKGROUND, GERMANIUM CRYSTAL ARRAY, COI↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a Drilling Optimization System for Improved Overall Rate of Penetration in Geothermal Wells

Geothermal energy is renewable, reliable and environmentally friendly source of energy. The major cost in the development of geothermal wells is the actual drilling of the wells. The main objective of this paper is to introduce a new real-time drilling optimization system designed for granite formation to reduce the overall drilling cost. In this study, a drilling optimization system is verified using drilling data from Utah-Forge well 58-32. The drilling optimization system used the Utah-Forge well 58-32 data to achieve real-time unconfined compressive strength (UCS). Based on the UCS value from the previous feet, the system simulates the ROP for the next drilling feet. The drilling optimization system utilizes the Differential Evolution Algorithm (DEA), which is a metaheuristic method to search the space of solution, to find the best operating parameters (i.e. WOB and RPM) for the next drilling foot. The optimization algorithm takes a maximum cutter temperature into account as a constraint and avoids the accelerated wear. The developed drilling optimization system improves ROP responses and reduces the drilling cost of geothermal wells. The simulated ROP results from the system show a good agreement with the ROP from Utah-Forge well 58-32 drilling data. The drilling time before and after optimization for both intervals were presented.

15 GEOTHERMAL ENERGY↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiation Protection Aspects of the SPES Project at LNL

The SPES (Selective Production of Exotic Species) project will be built at the National Laboratories in Legnaro (Italy) of the National Institute of Nuclear Physics (INFN). Its goal will be the development of radioactive ion beams and the consequent re-acceleration with the existing linac to perform forefront research in nuclear physics. Radiation protection aspects are being considered at every stage of the project, e.g. civil construction planning, control system design and special technological plants. These aspects have been studied with the Monte Carlo transport code FLUKA and are presented in this paper.

43 PARTICLE ACCELERATORS↗

Deep Well #4 Backup Power Systems Project Closeout Report

The project scope was to install a diesel generated power source to deep well 4 in addition to the existing commercial power source. The diesel power source and its fuel supply system shall be seismically qualified to withstand a Performance Category 4 (PC-4) seismic event. This diesel power source will permit the deep well to operate during a loss of commercial power. System design will incorporate the ability to select and transfer power between the new diesel power source and commercial power sources for the the deep well motor and TRA-672 building loads.

99 GENERAL AND MISCELLANEOUS↗

Export Control Requirements for Tritium Processing Design and R&D

This document will address requirements of export control associated with tritium plant design and processes. Los Alamos National Laboratory has been working in the area of tritium plant system design and research and development (R&D) since the early 1970’s at the Tritium Systems Test Assembly (TSTA). This work has continued to the current date with projects associated with the ITER project and other Office of Science Fusion Energy Science (OS-FES) funded programs. ITER is currently the highest funding area for the DOE OS-FES. Although export control issues have been integrated into these projects in the past a general guidance document has not been available for reference in this area. To address concerns with currently funded tritium plant programs and assist future projects for FES, this document will identify the key reference documents and specific sections within related to tritium research. Guidance as to the application of these sections will be discussed with specific detail to publications and work with foreign nationals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Export Control Requirements for Tritium Processing Design and R&D

This document will address requirements of export control associated with tritium plant design and processes. Los Alamos National Laboratory has been working in the area of tritium plant system design and research and development (R&D) since the early 1970’s at the Tritium Systems Test Assembly (TSTA). This work has continued to the current date with projects associated with the ITER project and other Office of Science Fusion Energy Science (OS-FES) funded programs. ITER is currently the highest funding area for the DOE OS-FES. Although export control issues have been integrated into these projects in the past a general guidance document has not been available for reference in this area. To address concerns with currently funded tritium plant programs and assist future projects for FES, this document will identify the key reference documents and specific sections within related to tritium research. Guidance as to the application of these sections will be discussed with specific detail to publications and work with foreign nationals.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Computational analysis of deployable wind turbine systems in defense operational energy applications.

The U.S. military has been exploring pathways to reduce the logistical burden of fuel on virtually all their missions globally. Energy harvesting of local resources such as wind and solar can help increase the resilience and operational effectiveness of military units, especially at the most forward operating bases where the fuel logistics are most challenging. This report considers the potential benefits of wind energy provided by deployable wind turbines as measured by a reduction in fuel consumption and supply convoys to a hypothetical network of Army Infantry Brigade Combat Team bases. Two modeling and simulation tools are used to represent the bases and their operations and quantify the impacts of system design variables that include wind turbine technologies, battery storage, number of turbines, and wind resource quality. The System of Systems Analysis Toolkit Joint Operational Energy Model serves as a baseline scenario for comparison. The Hybrid Optimization of Multiple Energy Resources simulation tool is used to optimize a single base within the larger Joint Operational Energy Model. The results of both tools show that wind turbines can provide significant benefits to contingency bases in terms of reduced fuel use and number of convoy trips to resupply the base. The match between the turbine design and wind resource, which is statistically low across most of the global land area, is a critical design consideration. The addition of battery storage can enhance the benefits of wind turbines, especially in systems with more wind turbines and higher wind resources. Wind turbines may also provide additional benefits to other metrics such as resilience that may be important but not fully considered in the current analysis. ACKNOWLEDGEMENTS The authors would like to thank the following individuals for their helpful support, feedback and review to improve this report: U.S. Department of Energy Wind Energy Technologies Office, Patrick Gilman and Bret Barker; Idaho National Laboratory, Jake Gentle and Bradley Whipple; The National Renewable Energy Laboratory, Robert Preus and Tony Jimenez; Sandia National Laboratories, Alan Nanco, Dennis Anderson, and Hai Le. In addition, numerous discussions with military and industry stakeholders over the year were invaluable in focusing the efforts represented in this report.

17 WIND ENERGY↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

Power over Ethernet (PoE) technology offers the ability to provide both low-voltage direct current (DC) power and communication over a standard Ethernet cable—also referred to as a local area network (LAN) cable or Category cable. Light-emitting diode (LED) technology has reduced the power required for lighting applications, while advances in PoE standards and technology have yielded substantial increases in the amount of power that can be delivered to a networked device over a single cable. As a result, PoE technology is emerging in lighting and many other applications beyond its historical foothold in telephony and networking equipment. Several major LED luminaire manufacturers have introduced PoE connected lighting systems in recent years, making this a potentially disruptive technology. PoE lighting systems can offer improved efficiency relative to traditional line voltage alternating current (AC) systems, because AC-DC power conversion losses can be reduced if this work is consolidated among one or more PoE switches, rather than being distributed among a greater number of smaller LED drivers. However, this effect can be offset to some extent by increased losses associated with an increased voltage drop in the low-voltage Ethernet cabling. In fact, these losses could exceed 15% in poorly designed systems. Aspects of cable design that can affect cable energy performance include American Wire Gauge (AWG), Category (e.g., 5e), shielding, and fire rating (e.g., CMP). Installation practices (e.g., bending, bundling, conduit) can also affect cable performance. Although cable energy losses can be predicted with knowledge of conductor DC resistance (DCR), and DCR can be estimated based on rated AWG, most product datasheets state maximum DCR - or reference standards that specify DCR limits - in lieu of nominal DCR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream from the patient. Both systems demonstrate substantial utility for online treatment verification and QA of photon external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Choreographer Pre-Testing Code Analysis and Operational Testing.

Choreographer is a "moving target defense system", designed to protect against attacks aimed at IP addresses without corresponding domain name system (DNS) lookups. It coordinates actions between a DNS server and a Network Address Translation (NAT) device to regularly change which publicly available IP addresses' traffic will be routed to the protected device versus routed to a honeypot. More details about how Choreographer operates can be found in Section 2: Introducing Choreographer. Operational considerations for the successful deployment of Choreographer can be found in Section 3. The Testing & Evaluation (T&E) for Choreographer involved 3 phases: Pre-testing, Code Analysis, and Operational Testing. Pre-testing, described in Section 4, involved installing and configuring an instance of Choreographer and verifying it would operate as expected for a simple use case. Our findings were that it was simple and straightforward to prepare a system for a Choreographer installation as well as configure Choreographer to work in a representative environment. Code Analysis, described in Section 5, consisted of running a static code analyzer (HP Fortify) and conducting dynamic analysis tests using the Valgrind instrumentation framework. Choreographer performed well, such that only a few errors that might possibly be problematic in a given operating situation were identified. Operational Testing, described in Section 6, involved operating Choreographer in a representative environment created through Emulytics TM . Depending upon the amount of server resources dedicated to Choreographer vis-á-vis the amount of client traffic handled, Choreographer had varying degrees of operational success. In an environment with a poorly resourced Choreographer server and as few as 50-100 clients, Choreographer failed to properly route traffic over half the time. Yet, with a well-resourced server, Choreographer handled over 1000 clients without missrouting. Choreographer demonstrated sensitivity to low-latency connections as well as high volumes of traffic. In addition, depending upon the frequency of new connection requests and the size of the address range that Choreographer has to work with, it is possible for all benefits of Choreographer to be ameliorated by its need to allow DNS servers rather than the end client to make DNS requests. Conclusions and Recommendations, listed in Section 7, address the need to understand the specific use case where Choreographer would be deployed to assess whether there would be problems resulting from the operational considerations described in Section 3 or performance concerns from the results of Operational Testing in Section 6. Deployed in an appropriate architecture with sufficiently light traffic volumes and a well-provisioned server, it is quite likely that Choreographer would perform satisfactorily. Thus, we recommend further detailed testing, to potentially include Red Team testing, at such time a specific use case is identified

97 MATHEMATICS AND COMPUTING↗