Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

AUTOMATIC GENERATION OF EVENT TREES AND FAULT TREES: A MODEL-BASED APPROACH

In the past few decades, increasing complexity in modern engineering systems has been driven by the integration of a large number of components and by the fact that the system operations involve many disciplines (e.g., thermal-hydraulics, plant operations, cyber-security). Current safety/reliability modeling approaches to such systems are labor intensive, difficult to learn, and rely heavily on simplistic Boolean logic to depict failure propagation and accident progression. While these methods serve well for simple systems (i.e., linear causal systems with limited small inter- and intra-system interactions), their results are difficult to verify when modeling complex systems (typically performed through the extensive use of modeling assumptions). The development of new methods is addressed to meet these challenges through a model-based system engineering (MBSE) lens. Under MBSE philosophy, every aspect of the system (form or function) is represented by a model that completely characterizes its architecture or behavior. MBSE approach greatly improves the management of design, analysis and verification of complex systems. An integration of Dynamic Probabilistic Risk Assessment (DPRA) methods with MBSE models is proposed to perform safety/reliability analyses of engineering systems. In particular, MBSE representation of the system (performed using Systems Modeling Language [SysML]) is coupled with DPRA methods to automatically generate event trees and fault trees.

97 - MATHEMATICS AND COMPUTING↗

High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation

This report summarizes the work performed by University of California San Diego (UCSD) – Honeywell Aerospace (Honeywell) team for the U.S. Department of Energy/Advanced Research Projects Agency-Energy (DOE/ARPA-E) under Phase 1 (April 2021 – October 2023) project, Cooperative Agreement DE-AR0001347 entitled “High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation”. The main objective of this project is to develop and demonstrate an energy storage and power generation (ESPG) system operating on bio liquid natural gas (LNG) for electric aviation applications. The ESPG system concept in this project is a fuel cell, battery, and gas turbine hybrid system that incorporates an innovative solid oxide fuel cell (SOFC) technology. This SOFC technology has two main novel elements: (i) a lightweight and compact stack architecture that consists of cells and cell modules in electrical parallel and series connections (the module design) and (ii) exceptionally high performance, direct methane thin-film cells on porous substrate made by sputtering deposition process. This fuel cell has the specific power and volumetric power density suitable for electric aviation applications. Based on the current status of the SOFC technology, the Phase 1 work focused on the following activities: (i) ESPG System Modeling – to design and optimize an aircraft SOFC-based ESPG system concept that met the performance, weight and cost targets; (ii) Cell Material Development and Scaleup – to demonstrate scalability of the sputtering process for manufacture of thin-film SOFC cells of practical sizes, confirm the exceptional performance of sputtered cells, improve cell stability and durability for operation with hydrogen and methane fuel, and develop a suitable electrically conducting porous substrate to replace the current non-conducting ceramic substrate; (iii) Stack Development – to design and manufacture stack components for the stack architecture, evaluate and select a suitable sealant, and build and operate multi-cell stacks to demonstrate stack operation, and (iv) Technology to Market – to develop business models and commercialization plans, conduct various market and technology analysis and estimate SOFC and ESPG system costs.

25 ENERGY STORAGE↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Allocation Mechanisms in Rationed Markets

Economic theory has come to play an important role in power system operations through the design of wholesale markets that are central to their operation. Furthermore, transactive energy places economic theory as a cornerstone in its operational concept as it seeks to integrate the technical needs of the power system with the preferences of its participants. Traditionally the mechanism employed is the continuous double-auction but de-pending on the circumstances the power system find itself in, this mechanism may or may not be the most appropriate, i.e. a one-size fits all market institution cannot be recommended without regard for the features of the underlying trading environment. This paper seeks to explain the economic rationale that guides the choice of a market institution and takes recourse to a theoretical demonstration in the context of a rationed power system scenario where demand exceeds generation (due to any number of events such as outages, microgrid operation, etc) and electrical energy must be rationed to better understand which types of mechanisms are most appropriate.

transactive energy, power system economics, econom↗

Design and Implementation of a Metadata-rich File System

Despite continual improvements in the performance and reliability of large scale file systems, the management of user-defined file system metadata has changed little in the past decade. The mismatch between the size and complexity of large scale data stores and their ability to organize and query their metadata has led to a de facto standard in which raw data is stored in traditional file systems, while related, application-specific metadata is stored in relational databases. This separation of data and semantic metadata requires considerable effort to maintain consistency and can result in complex, slow, and inflexible system operation. To address these problems, we have developed the Quasar File System (QFS), a metadata-rich file system in which files, user-defined attributes, and file relationships are all first class objects. In contrast to hierarchical file systems and relational databases, QFS defines a graph data model composed of files and their relationships. QFS incorporates Quasar, an XPATH-extended query language for searching the file system. Results from our QFS prototype show the effectiveness of this approach. Compared to the de facto standard, the QFS prototype shows superior ingest performance and comparable query performance on user metadata-intensive operations and superior performance on normal file metadata operations.

99 GENERAL AND MISCELLANEOUS↗

Western Wind and Solar Integration Study

The Western Wind and Solar Integration Study (WWSIS) is one of the largest regional wind and solar integration studies to date. It was initiated in 2007 to examine the operational impact of up to 35% energy penetration of wind, photovoltaics (PV), and concentrating solar power (CSP) on the power system operated by the WestConnect group of utilities in Arizona, Colorado, Nevada, New Mexico, and Wyoming (see study area map). WestConnect also includes utilities in California, but these were not included because California had already completed a renewable energy integration study for the state. This study was set up to answer questions that utilities, public utilities commissions, developers, and regional planning organizations had about renewable energy use in the west: (1) Does geographic diversity of renewable energy resource help mitigate variability; (2) How do local resources compare to out-of-state resources; (3) Can balancing area cooperation help mitigate variability; (4) What is the role and value of energy storage; (5) Should reserve requirements be modified; (6) What is the benefit of forecasting; and (7) How can hydropower help with integration of renewables? The Western Wind and Solar Integration Study is sponsored by the U.S. Department of Energy (DOE) and run by NREL with WestConnect as a partner organization. The study follows DOE's 20% Wind Energy by 2030 report, which did not find any technical barriers to reaching 20% wind energy in the continental United States by 2030. This study and its partner study, the Eastern Wind Integration and Transmission Study, performed a more in-depth operating impact analysis to see if 20% wind energy was feasible from an operational level. In DOE/NREL's analysis, the 20% wind energy target required 25% wind energy in the western interconnection; therefore, this study considered 20% and 30% wind energy to bracket the DOE analysis. Additionally, since solar is rapidly growing in the west, 5% solar was also considered in this study. The goal of the Western Wind and Solar Integration Study is to understand the costs and operating impacts due to the variability and uncertainty of wind, PV, and CSP on the grid. This is mainly an operations study, (rather than a transmission study), although different scenarios model different transmission build-outs to deliver power. Using a detailed power system production simulation model, the study identifies operational impacts and challenges of wind energy penetration up to 30% of annual electricity consumption.

14 SOLAR ENERGY↗

Development and testing of a photometric method to identify non-operating solar hot water systems in field settings

This report presents the results of experimental tests of a concept for using infrared (IR) photos to identify non-operational systems based on their glazing temperatures; operating systems have lower glazing temperatures than those in stagnation. In recent years thousands of new solar hot water (SHW) systems have been installed in some utility districts. As these numbers increase, concern is growing about the systems dependability because installation rebates are often based on the assumption that all of the SHW systems will perform flawlessly for a 20-year period. If SHW systems routinely fail prematurely, then the utilities will have overpaid for grid-energy reduction performance that is unrealized. Moreover, utilities are responsible for replacing energy for loads that failed SHW system were supplying. Thus, utilities are seeking data to quantify the reliability of SHW systems. The work described herein is intended to help meet this need. The details of the experiment are presented, including a description of the SHW collectors that were examined, the testbed that was used to control the system and record data, the IR camera that was employed, and the conditions in which testing was completed. The details of the associated analysis are presented, including direct examination of the video records of operational and stagnant collectors, as well as the development of a model to predict glazing temperatures and an analysis of temporal intermittency of the images, both of which are critical to properly adjusting the IR camera for optimal performance. Many IR images and a video are presented to show the contrast between operating and stagnant collectors. The major conclusion is that the technique has potential to be applied by using an aircraft fitted with an IR camera that can fly over an area with installed SHW systems, thus recording the images. Subsequent analysis of the images can determine the operational condition of the fielded collectors. Specific recommendations are presented relative to the application of the technique, including ways to mitigate and manage potential sources of error.

15 GEOTHERMAL ENERGY↗

Computer-based human-machine interfaces for emergency operation - 233

The Halden Reactor Project (HRP) has many years of experience in developing and evaluating principles for computer-based human-machine interfaces (HMIs). We have synthesized the lessons learned in an integrated design concept that is implemented on a boiling water reactor (BWR) simulator in the Halden Man Machine Laboratory (HAMMLAB). The design concept is intended to alert and support the operators in monitoring and controlling the plant during normal operation, emergency situations and outages. The computer-based HMIs include an alarm system, operating displays, operating procedures and large screen displays. The design concept has been tested in a simulator study in HAMMLAB. This paper describes the design and initial testing of the computer-based emergency operating procedures (EOPs) and other displays to support the operators when using the EOPs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dragonstone Strategy – State of Cybersecurity in the Oil & Natural Gas Sector

The oil & natural gas (ONG) system touches every corner of the nation and increased communications & control capabilities have not only allowed for greater efficiency of system operation, but have also created a massive target for adversaries to launch cyber-attacks. Like any other heavy industrial process, the ONG system relies on a complex system of information technology (IT) and operational technology (OT) devices. The current state of cyber-preparedness across the ONG industry varies from organization to organization. Among the most common challenges that ONG companies face are remote locations, longlived field assets, and lacking capabilities to find and track malware on their systems. ONG companies tend to be concerned with lack of cyber-awareness from employees, risk stemming from remote access for operations & maintenance, and software vulnerabilities within third-party equipment. Various industry and government organizations are performing research and development activities to address some of these challenges, but in many cases industry stakeholders are not aware of solutions that already exist. It is clear that a need exists for a coherent, comprehensive, multi-layered strategy for assuring the security and resilience of the nation's pipeline infrastructure against cyber threats. For a variety of reasons, the general consensus from stakeholders interviewed by LLNL is that the state of cyber-security within the electric grid is currently outpacing its ONG cousin. Existing strategies for the resilience and cyber-security of the electric grid can and should be leveraged to provide immediate benefits to the ONG system. In LLNL’s view, there are two key factors currently limiting the development of necessary cyber-practices within the ONG industry: The sheer number of differing regulatory bodies and trade groups offering both standards and best-practice recommendations for ONG cyber-security makes it difficult to create a comprehensive, directed, and coherent strategy that is applicable to all players within the ONG industry. The ONG industry is unaware of potentially useful technologies that have been developed for ensuring cyber-security of other infrastructure systems, such as the electric grid. Leveraging these technologies—and the science and engineering behind them—can provide some low-hanging fruit that can greatly improve cyber-security in the ONG industry without significant investments in terms of time and money. In the months following this report, LLNL will continue to perform outreach to key oil & gas industry stakeholders in a continual effort to identify the most pressing cyber-resilience issues in the industry. This outreach will be supplemented with LLNL’s threat intelligence capabilities to begin painting a clearer picture of the overall threat landscape faced by this sector. This assessment will be threat-informed and while the strategy itself will not be classified we will leverage intelligence analysis and adversary capabilities to identify gaps in current cybersecurity practices for oil & gas pipeline systems. Recommended efforts will be compiled into a cyber-resilience roadmap for the oil & gas pipeline sector, in which LLNL will highlight priority activities to immediately improve the state of cyber-resilience in the industry.

02 PETROLEUM↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

Cost optimization of high recovery single stage gap membrane distillation

Estimating the cost of membrane distillation (MD) processes at scale is confounded by the vast array of possible process configurations, module configurations, and operating conditions and the extreme sensitivity of MD costs to these parameters. This work develops a comprehensive MD cost optimization framework for minimizing the levelized cost of water (LCOW) as a function of feed salinity and temperature. Our single stage gap MD model fully captures solution properties, heat transfer, and mass transfer relationships in the modules to determine the cost optimal design as a function of multiple decision variables, including process configuration (feed location and connectivity between the hot and cold-side), the gap type (air, permeate, conductive), equipment sizes (membrane, heater, chiller, and heat exchanger units), and operating conditions (flow rates, hot and cold side temperatures, and heating and cooling duties). We estimate that the minimum LCOW of conductive gap MD ranges between $\$$10 and $\$$16 per m 3 for feed salinities of 25 g/L to 200 g/L and water recoveries of 30%–75%. Further, we update several heuristic assumptions for cost optimal system operation, including: increased thermal conductivity of the gap decreases system costs; cost optimal MD operates at the highest allowable temperature; and the LCOW is a strong function of brine salinity. Finally, we find that improving membrane properties and lowering heating and cooling costs will provide only modest reductions in costs (<25%).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of High Wind Power Penetration on Hydroelectric Unit Operations

The Western Wind and Solar Integration Study (WWSIS) investigated the operational impacts of very high levels of variable generation penetration rates (up to 35% by energy) in the western United States. This work examines the impact of this large amount of wind penetration on hydroelectric unit operations. Changes in hydroelectric unit operating unit patterns are examined for an aggregation of all hydro generators. The cost impacts of maintaining hydro unit flexibility are assessed and compared for a number of different modes of system operation.

13 HYDRO ENERGY↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Continuous-time look-ahead flexible ramp scheduling in real-time operation

This paper develops a novel continuous-time look-ahead optimization model for co-optimizing balancing energy and flexible ramp products in real-time power systems operation. In addition, a continuous-time day-ahead operation model is developed to commit and schedule an adequate subset of generating units for providing balancing energy and ramping requirements in real-time operation. The up and down flexible ramp products are defined as continuous-time decision trajectories that continuously supply the real-time up and down ramping requirements of the system. The deliverability of flexible ramp products is secured through reserving the respective power requirements in generation capacity constraints of generating units. A function space solution method is proposed to reduce the dimensionality of day-ahead and real-time models through projecting them into finite-dimensional function spaces spanned by Bernstein polynomials, where the real-time operation decisions are modeled with a higher accuracy level than day-ahead decisions. Simulations are conducted on the IEEE-RTS system using CAISO load data, and the numerical results showcase the effectiveness of the proposed model in supplying the energy and flexible ramp requirements and avoiding ramping scarcity in the system, while reducing the operation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid oxide fuel cell steam reforming power system

The present invention is a Solid Oxide Fuel Cell Reforming Power System that utilizes adiabatic reforming of reformate within this system. By utilizing adiabatic reforming of reformate within the system the system operates at a significantly higher efficiency than other Solid Oxide Reforming Power Systems that exist in the prior art. This is because energy is not lost while materials are cooled and reheated, instead the device operates at a higher temperature. This allows efficiencies higher than 65%.

25 ENERGY STORAGE↗

Operation-adversarial scenario generation

This paper proposes a modified conditional generative adversarial network (cGAN) model to generate net load scenarios for power systems that are statistically credible, conditioned by given labels (e.g., seasons), and, at the same time, “stressful” to the system operations and dispatch decisions. The measure of stress used in this paper is based on the operating cost increases due to net load changes. The proposed operation-adversarial cGAN (OA-cGAN) internalizes a DC optimal power flow model and seeks to maximize the operating cost and achieve a worst-case data generation. The training and testing stages employed in the proposed OA-cGAN use historical day-ahead net load forecast errors and has been implemented for the realistic NYISO 11-zone system. In conclusion, our numerical experiments demonstrate that the generated operation-adversarial forecast errors lead to more cost-effective and reliable dispatch decisions.

42 ENGINEERING↗

A Hybrid Stochastic-Interval Operation Strategy for Multi-Energy Microgrids

Increasing deployment of distributed energy resources intensifies interactions among electric, gas, heating, and cooling systems. Inherent uncertainties ranging from internal parameters to external inputs also impose significant challenges on system operation. A coordinated scheduling method is, therefore, desired for facilitating efficient operation of multi-energy microgrids under multiple uncertainties. In this paper, a deterministic coordinated scheduling model is developed first with detailed modeling of system dynamics and device parameters to fully characterize complex interactions among multi-energy carriers. Then, a hybrid stochastic-interval method is proposed to account for heterogeneous uncertainties in decisions of operational strategies. Specifically, performance and efficiency uncertainties of distributed energy resources, and injection uncertainty of renewable sources and multienergy demands are characterized by interval-based uncertain operation regions and probability distributions, respectively. A scenario-based two-stage algorithm is developed to solve the problem so that multiple uncertainties are preserved in the entire decision-making process. Moreover, adjustable operational strategies are determined to hedge uncertainty by considering operators’ risk preferences. The validity of the proposed method is verified by comprehensive case studies on a test system.

hybrid stochastic-interval approach↗