Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOPLASTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Effect of plasma treatment on LMPAEK/CF tape and composites manufactured by automated tape placement (ATP)

Automated tape placement (ATP) process is widely used in aerospace for its advanced process control and multi-axis capabilities but faces issues like limited choice of materials and suboptimal tape consolidation. This study investigates air plasma treatment on ATP carbon fiber thermoplastic feedstock tape to address these challenges. The effects on low melt Polyaryletherketone/carbon fiber unidirectional tape (LMPAEK/CF UD tape) were analyzed. Treated and untreated tapes were used to fabricate composites and evaluated for physical, thermal, mechanical, and interfacial properties. Atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) analyses revealed surface roughness changes (on LMPAEK), extent of oxidation, and the presence of hydroxyl/carboxyl groups. Composites from plasma-treated tapes showed a 7.6% increase in tensile strength, 8% in tensile modulus, 18% in flexural strength, and 8.3% in flexural modulus. Further, the interlaminar shear strength improved by 18.7%. Failure analysis showed untreated composites failed via inter-ply and fiber-matrix delamination, while treated composites experienced matrix cracking and fiber breakage. This study highlights atmospheric plasma treatment as a solution to ATP’s limitations, significantly enhancing LMPAEK/CF UD tape composites’ properties.

36 MATERIALS SCIENCE↗

Fiber orientation and porosity in large-format extrusion process: The role of processing parameters

Controlling fiber orientation and porosity in short-fiber thermoplastic composites is important for enhancing mechanical, electrical and thermal properties in large-format additive manufacturing. This study employs a factorial design of experiments (DoE) to assess the effects of nozzle diameter (5.08 mm–10.16 mm), temperature (230–250 °C), and extruder screw speed (150–280 rpm) on flow rate, shear rate, porosity, fiber orientation, fiber length and tensile strength in 20 % carbon fiber-filled acrylonitrile butadiene styrene. ANOVA results show that screw speed significantly impacts flow rate, while nozzle diameter and temperature have lesser effects. Shear rate increases with smaller nozzles and higher speeds. Porosity decreases from 5.58 % with a 10.16 mm nozzle to 3.11 % with a 5.08 mm nozzle at 150 rpm due to increased shear rates, which induce shear thinning, reducing viscosity and facilitating gas escape. Larger nozzles (10.16 mm) produce larger, more heterogeneous pores, while smaller nozzles (5.08 mm) yield smaller, uniform pores. Beads produced with the 5.08 mm nozzle exhibit longer fiber lengths due to reduced residence time, lower shear stress, and better alignment. Fiber orientation improves with smaller nozzles due to higher shear rates but decreases with higher screw speeds (280 rpm) due to shorter residence times. The highest fiber alignment (A xx ∼ 0.65) and low porosity (∼3%) were achieved with a 5.08 mm nozzle at 150 rpm, while equivalent additive manufacturing-compression molding samples exhibited better tensile strength (∼93 MPa) under these conditions. In conclusion, these findings emphasize the importance of optimizing processing parameters to enhance fiber alignment and reduce porosity for improved mechanical performance.

Design of experiments↗

Sizing comingled CF/PA 6 fibers with cellulose nanofibrils for enhanced performance properties

Compatibility between the reinforcing phase and the polymer matrix is critical to achieving the desired mechanical and thermal performance of composite materials. Several mechanisms can enhance this interfacial interaction, including surface treatments (e.g., oxidation, plasma, or irradiation), in-situ nanoparticle deposition, and fiber sizing. Here, in this study, cellulose nanofibrils (CNF) were employed as a sustainable sizing agent to modify the interface in commingled carbon fiber (CF)/polyamide 6 (PA 6) yarns, in which CF and PA6 filaments are intimately blended to enable simultaneous consolidation. A 0.25 wt% CNF aqueous suspension was applied under bath sonication to ensure uniform dispersion and minimize agglomeration. CNF-sized and unsized yarns were used to fabricate unidirectional composite plates via filament winding on a flat mandrel, followed by compression molding. Scanning electron microscopy confirmed CNF presence on both CF and PA6 filaments. CNF-sized composites exhibited increments in interlaminar shear strength (ILSS) by 50%, flexural strength by 11%, and tensile strength by 2.5% compared to unsized composites. Thermal analysis showed minimal changes in degradation temperature and crystallinity. These findings demonstrate that CNF sizing enhances interfacial bonding and mechanical performance, offering a scalable and environmentally friendly strategy for thermoplastic composite manufacturing along with yarn/tow handleability.

Cellulose nanofibrils (CNF)↗

Recycling of CF-ABS machining waste for large format additive manufacturing

Large format additive manufacturing (LFAM) necessitates the use of short fiber thermoplastic composites, such as carbon fiber filled acrylonitrile butadiene styrene, to enable printing. Currently, when LFAM parts are machined into their final shape, the machining scrap (i.e., small flake like particles and offcuts) is landfilled. Previous studies have demonstrated the viability of recycling end-of-life LFAM parts by shredding and optionally re-compounding the material back into pellets. However, there is little understanding of the value and performance of recycled material made from LFAM machining scrap, which if pursued could motivate more broad recycling of this waste stream. In this study, recycled in-process machining scrap is explored as an LFAM feedstock source. Herein, it is found that the primary degradation mechanism of the recycled material is significant fiber length attrition during surface machining. While this fiber attrition negatively impacts the mechanical performance of the material in the print direction, it seems that the changes in processing behaviors and print quality, namely the surface roughness of the printed structure associated with shorter fiber lengths, is beneficial to interlayer adhesion. The tensile strength and elastic modulus of the recycled material, in the print direction, decreased 11% and 31% respectively compared to the pristine material. However, in the layer-wise direction it was found that the recycled material exhibited no significant change in elastic modulus and a significant 21% increase in tensile strength – a surprising result. In conclusion, this work indicates that machining waste could be a viable material stream for recycled LFAM feedstock materials.

42 ENGINEERING↗

Engineering mechanical and thermomechanical performance in additive manufacturing–Compression molded composites through multiplexed extrusion

Traditional extrusion-based additive manufacturing is limited to single material systems, restricting the multifunctional properties of composites. For this work to overcome this limitation, multiplexed additive manufacturing–compression molding (AM-CM) was employed to fabricate multi-material thermoplastic composites with spatially tailored architectures. Neat acrylonitrile butadiene styrene (ABS) and 20 wt% carbon-fiber reinforced ABS (CF-ABS) were co-extruded through a core–sheath nozzle to produce hybrid composites with neat ABS as sheath (30-50 wt%) and CF-ABS as core (50 – 70 wt%). The results show that the hybrid composites have balance of mechanical and thermomechanical performance. The tensile strength and modulus of hybrid composites exhibited a 61–95% and 173–473% increase compared to neat ABS with increases in CF-ABS content whereas the impact resistance improved by 41% compared to CF-ABS at 50 wt% ABS. Additionally, hybrid composites showed significant reduction (54 - 70%) in creep strain at 100 °C compared to neat ABS. These findings demonstrate that multiplexed AM-CM enables tunable structure–property relationships, reducing CF-ABS usage up to 50 wt% while maintaining balanced stiffness, toughness, and creep resistance.

Additive manufacturing↗

Plasma surface modification coupled with thermal and step-over distance effects on significant fracture improvement of adhesively-bonded metal-$\mathrm{CFRTP}$ dissimilar materials

Here, this work proposes an approach to improve the interfacial bonding between carbon-fiber-reinforced thermoplastic polymers (CFRTP) and thermoset adhesive by using the surface modification with the combination of air plasma, thermal, and step-over effects. Thanks to the proper heating which causes the exposure of carbon fibers on the CFRTP surface, both polymer matrix and these exposed carbon fibers can have improved bonding with adhesive due to air plasma treatment. By conducting the Double Cantilever Beam (DCB) tests performed on adhesively-bonded AA5052/CFRP-PA66 dissimilar joints, it was shown in this work that the average Mode I specific fracture energy can be improved up to about 180% compared to non-treated counterparts. The foregoing improvement can be further increased by considering the step-over distance of the surface treatment, which triggers the tortuous damage path in the failure process of adhesively-bonded structures. By manipulating this treatment parameter, often overlooked in the literature, and other parameters (i.e., treatment speed, nozzle tip-to-surface distance, etc.) investigated in this study, the average Mode I specific fracture energy of adhesively-bonded AA5052/CFRP-PA66 dissimilar joints can be improved reaching up to about 410% compared to non-treatment counterparts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance assessment of 3D printed multi-material energy absorber for automotive bumper: pedestrian lower extremity protection

Designing an energy absorber for automotive bumpers involves balancing low-speed and high-speed impacts to ensure safety, reduce repair costs, and meet regulatory standards. Here, this study explores a novel design using multi-material 3D printing and structural optimization to fabricate a lightweight and cost-efficient energy absorber. The design effectively dissipates energy in low-speed collisions and minimizes force transmission in high-speed pedestrain impacts, helping to meet both safety and performance requirements. The energy absorber design combines 20% carbon fiber-reinforced acrylonitrile butadiene styrene (CF-ABS) and thermoplastic polyurethane (TPU) for optimal stiffness and flexibility. It uses 3D-printed lattice structures optimized through finite element simulations to help meet both low-speed and high-speed impact requirements. Full-scale energy absorbers were 3D-printed using optimized CF-ABS/TPU blends and tested under high-speed impact using the Flexible Pedestrian Legform Impactor (Flex-PLI). For fair comparison, a baseline bumper with a traditional triangular lattice structure, also 3D-printed from the same CF-ABS/TPU materials, was similarly tested. Interestingly, both the optimized and baseline 3D-printed energy absorbers showed nearly identical performance, successfully meeting injury limits. Their performances were also benchmarked against an injection-molded energy absorber. While both 3D-printed and injection-molded designs met injury limits, the 3D-printed absorber exhibited a higher tibia bending moment, indicating an opportunity for further optimization. A Techno-Economic Analysis compared the costs of producing energy absorbers using traditional manufacturing and 3D printing. The analysis highlighted that 3D printing offers cost benefits for low to medium production volumes, with the total cost per energy absorber at ∼ $\$$74, compared to traditional methods that become economical beyond 2000 units.

Additive manufacturing↗

Multigraft Copolymer Superelastomers: Synthesis Morphology, and Properties

The synthesis of well-defined multigraft copolymers having a polydiene backbone with polystyrene side chains is briefly reviewed, with particular focus on controlling branch point spacing and branch point functionality. Use of living anionic polymerization and chlorosilane linking chemistry has led to the synthesis of series of materials having regularly spaced trifunctional (comb), tetrafunctional (centipede), and hexafunctional (barbwire) branch points. The morphologies of these materials were characterized by transmission electron microscopy and small-angle X-ray scattering, and it was found that the morphologies were controlled by the local architectural asymmetry associated with each branch point. Mechanical properties studies revealed that such multigraft copolymers represent a new class of thermoplastic elastomers (TPEs) with superior elongation at break and low residual strains as compared to conventional TPEs.

Uhrig, David↗

Electromagnetic Tracking of Intrafraction Prostate Displacement in Patients Externally Immobilized in the Prone Position

Purpose: To evaluate intrafraction prostate displacement among patients immobilized in the prone position using real-time monitoring of implanted radiofrequency transponders. Methods and Materials: The Calypso localization system was used to track prostate motion in patients receiving external beam radiation therapy (XRT) for prostate cancer. All patients were treated in the prone position and immobilized with a thermoplastic immobilization device. Real-time measurement of prostate displacement was recorded for each treatment fraction. These measurements were used to determine the duration and magnitude of displacement along the three directional axes. Results: The calculated centroid of the implanted transponders was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 38.0%, 13.9%, and 4.5% of the time. In the lateral dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 2.7%, 0.4%, and 0.06% of the time. In the superior-inferior dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 16.1%, 4.7%, and 1.5% of the time, respectively. In the anterior-posterior dimension, the centroid was offset from the treatment isocenter by >=2 mm, >=3 mm, and >=4 mm for 13.4%, 3.0%, and 0.5% of the time. Conclusions: Intrafraction prostate displacement in the prone position is comparable to that in the supine position. For patients with large girth, in whom the supine position may preclude accurate detection of implanted radiofrequency transponders, treatment in the prone position is a suitable alternative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assessment of Frameless Fractionated Stereotactic Radiotherapy Using Cone Beam Computed Tomography

Purpose: A quality assessment of intracranial stereotactic radiotherapy was performed using cone beam computed tomography (CBCT). Setup errors were analyzed for two groups of patients: (1) those who were positioned using a frameless SonArray (FSA) system and immobilized with a bite plate and thermoplastic (TP) mask (the bFSA group); and (2) those who were positioned by room laser and immobilized using a TP mask (the mLAS group). Methods and Materials: A quality assurance phantom was used to study the system differences between FSA and CBCT. The quality assessment was performed using an Elekta Synergy imager (XVI) (Elekta Oncology Systems, Norcross, GA) and an On-Board Imager (OBI) (Varian Medical Systems, Palo Alto, CA) for 25 patients. For the first three fractions, and weekly thereafter, the FSA system was used for patient positioning, after which CBCT was performed to obtain setup errors. Results: (1) Phantom tests: The mean differences in the isocenter displacements for the two systems was 1.2 {+-} 0.7 mm. No significant variances were seen between the XVI and OBI units (p{approx}0.208). (2)Patient tests: The mean of the displacements between FSA and CBCT were independent of the CBCT system used; mean setup errors for the bFSA group were smaller (1.2 mm) than those of the mLAS group (3.2 mm) (p < 0.005). For the mLAS patients, the 90th percentile and the maximum rotational displacements were 3{sup o} and 5{sup o}, respectively. A 4-mm drift in setup accuracy occurred over the treatment course for 1 bFSA patient. Conclusions: System differences of less than 1 mm between CBCT and FSA were seen. Error regression was observed for the bFSA patients, using CBCT (up to 4 mm) during the treatment course. For the mLAS group, daily CBCT imaging was needed to obtain acceptable setup accuracies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the viscoplastic behavior of a semicrystalline polymer

In this study, a complex constitutive relation is identified using inverse modeling with the nominal mechanical response as sole experimental input. The methodology is illustrated for a semicrystalline thermoplastic in the presence of strain localization at finite deformations. The experimental database includes cylindrical tensile bars, compression pins and round notched bars loaded at strain rates spanning up to five decades and temperatures below and above T g . The data is organized into a calibration set and a validation set. The response of tensile specimens is determined using finite element analyses and a two-phase constitutive relation for semicrystalline polymers that accounts for temperature- and rate-sensitive plastic flow, pressure-sensitivity, small-strain softening and large-strain orientational hardening of the amorphous phase, along with the evolution of crystallinity. The large number of constitutive parameters is identified using an optimization tool coupled with the finite element solver and the calibration set from experiments. The methodology is shown to be successful in predicting the response of round notched bars and replicating the effects of temperature and strain rate on the severity of necking in tensile bars. The proposed model identification strategy is both simple and effective in comparison with other elaborate methods that attempt to access intrinsic behavior directly from high-fidelity experimental measurements.

36 MATERIALS SCIENCE↗

Simulation-driven design optimization of reaction injection molding (RIM) process for polydicyclopentadiene (pDCPD): Minimizing cycle time, defects, and warpage

Replacing metal components in trucks, trailers, and buses with lightweight polymer composites is challenging due to high temperatures and complex manufacturing. The Reaction Injection Molding (RIM) process using Dicyclopentadiene (DCPD) resin offers a solution by producing robust parts with excellent stiffness, impact strength, and resistance properties. Simulations are essential for optimizing this process, predicting defects, and improving quality. However, most commercial software is tailored for thermoplastics, requiring thermoset users to generate their own datasets. In this study, a material data card for DCPD was developed to perform RIM simulations. Design of Experiments (DOE) was used to identify key factors affecting filling, curing, and warpage, aiming to minimize cycle time and defects. The simulations explored varying injection gate parameters (size, location, number) and process conditions (mold/resin temperature, injection/curing pressure). Results showed that gate design significantly impacts filling behavior and defects. A single central gate provided balanced flow with fewer defects, while two corner gates led to more defects. Additionally, lower injection pressure increased filling time, while higher mold temperature accelerated curing but led to more warpage. In conclusion, this optimization framework aims to enhance DCPD part performance and promote sustainable manufacturing by reducing waste and energy consumption.

42 ENGINEERING↗

Comparison of Bolus Materials to Highly Absorbent Polypropylene and Rayon Cloth

This study assesses the utility of a highly absorbent polypropylene and rayon cloth (HAPRC) as a bolus material in radiation therapy. A comparison of various bolus materials used clinically at our center to the test bolus material, water-saturated HAPRC, was conducted. The reproducibility of the physical density was assessed by computerized tomography (CT) scanning the water-saturated HAPRC on a uniform density block phantom on multiple occasions, allowing the cloth to dry fully between subsequent CT scans. The cloth was found to have a consistent physical density between 0.8 and 1.0 g/cm{sup 3}. To evaluate the dosimetric impact of the various bolus materials, metal oxide semiconductor field effect transistor dosimetry measurements were performed for a 6 MV treatment beam on the anterior surface of an anthropomorphic thorax phantom. The ability of the bolus material to conform to an irregular surface was assessed by CT scanning the various bolus materials overlaying the nose of an anthropomorphic head phantom and another irregularly shaped test object. The HAPRC conforms well to irregular contours and is relatively inexpensive compared to Superflab and thermoplastic sheets. Before implementing the material into the clinical setting, an appropriate process for laundering the material should be determined, for hygienic reasons.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structural manipulation approaches towards enhanced sodium ionic conductivity in Na-rich antiperovskites

High-performance solid electrolytes are critical for realizing all-solid-state batteries with enhance safety and cycling efficiency. However, currently available candidates (sulfides and the NASICON-typ ceramics) still suffer from drawbacks such as inflammability, high-cost and unfavorable machinability Here we present the structural manipulation approaches to improve the sodium ionic conductivity in series of affordable Na-rich antiperovskites. Experimentally, the whole solid solutions of Na 3 OX (X ¼ Cl Br, I) are synthesized via a facile and timesaving route from the cheapest raw materials (Na, NaOH an NaX). The materials are nonflammable, suitable for thermoplastic processing due to low melting temperature (<300° C) without decomposing. Notably, owing to the flexibility of perovskite-type structure it's feasible to control the local structure features by means of size-mismatch substitution an unequivalent-doping for a favorable sodium ionic diffusion pathway. Enhancement of sodium ioni conductivity by 2 magnitudes is demonstrated by these chemical tuning methods. The optimized sodiu ionic conductivity in Na 2.9 Sr 0.05 OBr 0.6 I 0.4 bulk samples reaches 1.9 10 - 3 S/cm at 200° C and even highe at elevated temperature. Here, we believe further chemical tuning efforts on Na-rich antiperovskites wil promote their performance greatly for practical all-solid state battery applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure and plasticity in hot deformed FeAl intermetallic phase base alloy

This paper constitutes part of research conducted on the possibility of forming alloys based on intermetallic phases from the Fe-Al system via thermoplastic processing. Insufficient plasticity, which is an inhibitor of further development of these intermetallics as construction materials, makes the range of their applications limited. In the paper, an analysis is conducted of the influence of deformation parameters on the structure of an alloy of Fe-Al with the B2 type structure. Axi-symmetric compression tests were carried out at temperatures ranging from 600 deg. C to 1200 deg. C and at a deformation rate from 0.001 s{sup 1} to 10 s{sup -1}. Structural examination was carried out using light microscopy and transmission electron microscopy. A quantitative evaluation of the structure was made with the use of 'Met-Ilo'. The results obtained will be used for the development of mathematical models determining the influence of deformation parameters on the alloy structure.

36 MATERIALS SCIENCE↗

Property optimized energy absorber for automotive bumpers utilizing multi-material and structural design strategies

This study proposes a novel design for automotive bumper using optimized lattice structures and multi-materials to balance low-speed collision and high-speed pedestrian impact performance. Different blends of 20 % carbon fiber-reinforced acrylonitrile butadiene styrene with thermoplastic polyurethane were used to tailor material properties. The energy absorber features lattice structures with customized mechanical responses, created by varying the incline angle θ from 0 to 180°. We conducted 576 finite element simulations on a half-scale model to optimize energy absorption and stiffness, leading to 66 optimized designs that met both low-speed and high-speed impact criteria. Two sub-scale optimized energy absorbers with different peak forces—both meeting low-speed impact requirements—were 3D printed and validated through drop-weight testing. The one with lower peak stress demonstrated a more compliant response, exhibiting approximately 90 % lower initial peak force and an increase in energy absorption of around 33 % (from 24 J to 32 J). Compared to the baseline triangular lattice, the optimized absorber increased energy absorption by 68 % from (19 J to 32 J) and reduced peak stress by 70 %. It also showed near-complete recovery with minimal fractures, making it suitable for repeated use. This design improves safety while offering a lightweight, durable, and cost-effective bumper system.

36 MATERIALS SCIENCE↗

A Device and Procedure for Immobilization of Patients Receiving Limb-Preserving Radiotherapy for Soft Tissue Sarcoma

The purpose of this study was to determine the accuracy and efficiency of a custom-designed immobilization device for patients with extremity soft-tissue sarcoma. The custom device consisted of a thermoplastic shell, vacuum pillow, and adaptable baseplate. The study included patients treated from January 2005 to March 2007, with 92 patients immobilized with the custom device and 98 with an established standard. Setup times for these cohorts were analyzed retrospectively for conformal and intensity modulated radiotherapy techniques (IMRT). Thigh tumor setup times were analyzed independently. A subset of patients treated with IMRT was analyzed for setup error using the radiographically verified isocenter position measured daily with electronic portal imaging and cone-beam computed tomography. Mean setup time was reduced by 2.2 minutes when using the custom device for conformal treatment (p = 0.03) and by 5.8 min for IMRT of thigh tumors (p = 0.009). All other setup time comparisons were not significant. A significant systematic error reduction was seen in all directions using the custom device. Random error standard deviations favored the custom device. The custom device offers immobilization advantages. Patient setup time was reduced for conformal techniques and IMRT of thigh tumors. Positioning uncertainty was improved, permitting a reduction of the planning target volume margin by 2 to 4 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗