SEARCH · Search NASA
Results for “Tracker”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A 65 nm CMOS analog processor with zero dead time for future pixel detectors
Next generation pixel chips at the High-Luminosity (HL) LHC will be exposed to extremely high levels of radiation and particle rates. In the so-called Phase II upgrade, ATLAS and CMS will need a completely new tracker detector, complying with the very demanding operating conditions and the delivered luminosity (up to 5×10 34 cm –2 s –1 in the next decade). This work is concerned with the design of a synchronous analog processor with zero dead time developed in a 65 nm CMOS technology, conceived for pixel detectors at the HL-LHC experiment upgrades. It includes a low noise, fast charge sensitive amplifier featuring a detector leakage compensation circuit, and a compact, single ended comparator that guarantees very good performance in terms of channel-to-channel dispersion of threshold without needing any pixel-level trimming. A flash ADC is exploited for digital conversion immediately after the charge amplifier. In conclusion, a thorough discussion on the design of the charge amplifier and the comparator is provided along with an exhaustive set of simulation results.
Calorimeter development for the SuperNEMO double beta decay experiment
SuperNEMO is a double-β decay experiment, which will employ the successful tracker–calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-β decay isotope, reaching a sensitivity to the neutrinoless double-β decay (Ovββ) half-life of the order of 10 26 yr, corresponding to a Majorana neutrino mass of 50–100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, ΔE/E, around 3%/ $\sqrt{E9MeV)}$σ, or 7% $\sqrt{E9MeV)}$ FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. Here, we describe the R&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
The STAR MAPS-based PiXeL detector
The PiXeL detector (PXL) for the Heavy Flavor Tracker (HFT) of the STAR experiment at RHIC is the first application of the state-of-the-art thin Monolithic Active Pixel Sensors (MAPS) technology in a collider environment. Here, custom built pixel sensors, their readout electronics and the detector mechanical structure are described in detail. Selected detector design aspects and production steps are presented. The detector operations during the three years of data taking (2014–2016) and the overall performance exceeding the design specifications are discussed in the conclusive sections of this work.
Application of the Generic Electronics for Time Projection Chamber ($\mathrm{GET}$) readout system for heavy Radioactive isotope collision experiments
Here we have implemented the Generic Electronics for Time Projection Chamber (GET) in a SAMURAI Pion Reconstruction and Ion-Tracker (SπRIT) readout system for heavy radioactive ion collision experiments at RIKEN-RIBF. The SπRIT experiment is designed for heavy ion collision experiments with radioactive ion beams, where a Time Projection Chamber (TPC) with 12096 pixelized readout pads is employed as the main device. Since the TPC is located on the beam line, the readout electronics must handle small signals from pions as well as very large signals from beam or large fragment particles. Operation of the GET electronics during experiment functioned well using 270 time-bucket readout with 25 MHz sampling at an event Data acquisition (DAQ) rate of 60 Hz. Using the slope information of acquired signals it is possible to extend the dynamic range of dE/dx information compared to using the peak height information. However, huge signals arising from energetic δ-rays produced by un-interacted projectiles induce dead channels, which can be recovered after 70 μs on average.
Developing a diagnostic for energetic laser-Compton produced photon beams
This paper describes the design and simulation of a radiation detector system for diagnostic measurements of photon beams produced by Thomson or Compton Scattering. The photon beam is Compton scattered in a thin passive converter, and the resulting electrons are analyzed using a charge-coupled device-based tracker and classification algorithms. The flux of the scattered electrons is much lower than that of the photon beam and is additionally dispersed. This dispersal enables measurements while avoiding pileup, which is important in order to provide diagnostic information from intense 'shot’ based pulsed systems, such as those being built to leverage laser wakefield accelerators. Simulations indicate that the designed system is capable of resolving beam parameters from a single shot. The fidelity to which various beam parameters can be resolved is presented as are methods that could result in further improvement to diagnostic resolution.
Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1–1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of ~4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. Lastly, this fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.
Signals from fluorescent materials on the surface of silicon micro-strip sensors
For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.
First bulk and surface results for the ATLAS ITk Strip stereo annulus sensors
A novel microstrip sensor geometry, the stereo annulus, has been developed for use in the end-cap of the ATLAS experiment’s strip tracker upgrade at the HL-LHC. Its first implementation is in the ATLAS12EC sensors, a large-area, radiation-hard, single-sided, AC-coupled, n + -in-p design produced by the ITk Strip Sensor Collaboration and fabricated by Hamamatsu Photonics in early 2017. The results of the initial testing of two ATLAS12EC batches are presented here with a comparison to specification. The potential of the new sensor shape to reinvigorate endcap strip tracking is explained and its effects on sensor performance are isolated by comparing the bulk mechanical and electrical properties of the new sensor to the previous iteration of prototype, the conventional barrel ATLAS12A sensor. The surface properties of the new sensor are evaluated for full-size unirradiated sensors as well as for mini sensors unirradiated and irradiated with protons up to a fluence of 2.2 x 10 15 n eq cm -2 . The results show that the new stereo annulus ATLAS12EC sensors exhibit excellent performance and the expected irradiation evolution.
Results from the CBC3 readout ASIC for CMS 2S-modules
The CBC3 is the latest version of the CMS Binary Chip for readout of the outer radial region of the upgraded CMS Tracker at the High Luminosity LHC. This 254-channel, 130 nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, containing two overlaid silicon microstrip sensors, aligned with a parallel orientation. On-chip logic identifies Level-1 trigger primitives from high transverse-momentum tracks by selecting correlated clusters in the two sensors. The CBC3 was delivered in late 2016; wafer probing and performance tests have been carried out. Several prototype modules using the CBC3 have been produced and tested in the lab and in different beams. The results show that the CBC3 satisfies CMS requirements and only small corrections are needed for the final version of the chip for production.
Feasibility of hard X-ray imaging using monolithic active pixel sensors (MAPS)
Silicon detectors have been widely used in high energy physics (HEP) experiments. The outstanding properties of silicon detectors include radiation hardness, small material budget, fine spatial resolution, high speed and low cost. In this paper, we report initial results of using a single-bit Monolithic Active Pixel Sensor (MAPS), a leading candidate for the next generation trackers in high luminosity colliders, for hard X-ray imaging. The MAPS responses to X-ray with different energies are obtained and compared with simulation. The observed cluster sizes are larger than that predicted by the Continuous Slowing Down Approximation (CSDA) model, indicating that the charge diffusion process might play an important in the MAPS response to low energy electrons. In conclusion, this work paves the way towards multiple layer ultrafast silicon sensor applications in synchrotrons and XFEL beamlines.
Test results and prospects for RD53A, a large scale 65 nm CMOS chip for pixel readout at the HL-LHC
The CERN RD53 collaboration was founded to tackle the extraordinary challenges associated with the design of pixel readout chips for the innermost layers of particle trackers at future high energy physics experiments. Around 20 institutions are involved in the collaboration, which has the support of both ATLAS and CMS experiments. The goals of the collaboration include the comprehensive understanding of radiation effects in the 65 nm technology, the development of tools and methodology to efficiently design large complex mixed signal chips and, ultimately, the development of a full size readout chip featuring a 400 × 400 pixel array with 50μm pitch. In August 2017, the collaboration submitted the large scale chip RD53A, integrating a matrix of 400 × 192 pixels and embodying three different analog front-end designs. Here, this work discusses the characteristic of the RD53A chip, with some emphasis on the analog processors, and presents the first test results on the pixel array.
A HV silicon vertical JFET: TCAD simulations
In the future ATLAS Inner Tracker detector (ITk), several silicon strip modules will be biased by a single High-Voltage (HV) line, so that a switch between each strip sensor and the HV line is required to disconnect faulty sensors. Such a switch must satisfy strict requirements, such as being radiation hard, being able to sustain high voltages in the OFF state and being able to operate in a high magnetic field. At Brookhaven National Laboratory we conceived a new kind of solid-state switch that can potentially meet all the specs: it is a HV silicon vertical JFET. Before designing and fabricating the JFET, we did a study using numerical TCAD simulations that demonstrate the feasibility of fabricating the device in a standard planar technology. As a result, we report such simulations, highlighting in particular a few key parameters to which the JFET performances are most sensitive.
Performance of thin planar n-on-p silicon pixels after HL-LHC radiation fluences
The tracking detector of ATLAS, one of the experiments at the Large Hadron Collider (LHC), will be upgraded in 2024–2026 to cope with the challenging environment conditions of the High Luminosity LHC (HL-LHC). The LPNHE, in collaboration with FBK and INFN, has produced 130 μm thick n-on-p silicon pixel sensors which can withstand the expected large particle fluences at HL-LHC, while delivering data at high rate with excellent hit efficiency. Such sensors were tested in beam before and after irradiation both at CERN-SPS and at DESY, and their performance are presented in this paper. Here, beam test data indicate that these detectors are suited for all the layers where planar sensors are foreseen in the future ATLAS tracker: hit-efficiency is greater than 97% for fluences of Φ≲7x10 15 n eq /cm 2 and module power consumption is within the specified limits. Additionally, at a fluence of Φ=1.3x10 16 n eq /cm 2 , hit-efficiency is still as high as 88% and charge collection efficiency is about 30%.
A new Transition Radiation detector based on GEM technology
Transition Radiation Detectors (TRD) have the potential feature of separating particles by their gamma factor. Classical TRDs are based on Multi-Wire Proportional Chambers (MWPC) or straw tubes, using a Xenon based gas mixture to efficiently absorb transition radiation photons. These detectors operate well in experiments with relatively low particle multiplicity. The performance of MWPC-TRD in experiments with luminosity of order 10 34 cm 2 s –1 and above, is significantly deteriorated due to the high particle multiplicity and channel occupancy. Replacing MWPC or straw tubes with a high granularity Micro Pattern Gas Detectors (MPGD) like Gas Electron Multipliers (GEMs), could improve the performance of the TRD. In addition, GEM technology allows one to combine a tracker with TRD identification (GEM-TRD/T). This report presents a new TRD development based on GEM technology for the future Electron Ion Collider (EIC). The first beam test was performed at Jefferson Lab (Hall-D) using 3–6 GeV electrons. A GEM-TRD/T module has been exposed to electrons with and without a fiber radiator. First results of test beam measurements and comparison with Geant4 Monte Carlo are introduced here.
Extending the dynamic range of electronics in a Time Projection Chamber
When Time Projection Chambers (TPCs) are used in low to intermediate heavy ion collisions, the mass and momentum range of the emitted particles cover a wide range in energy losses. Many TPC readout electronics currently only have a single gain output with a fixed dynamic range. In a recent set of experiments using the SAMURAI Pion-Reconstruction and Ion-Tracker (StrRIT) TPC, it was important to simultaneously measure relativistic pions and heavy ion tracks from the same collisions. As the ionization from a track's energy loss is collected and multiplied by the anode wires, a distribution of image charges is induced on the TPC read-out pads. If the avalanche on a wire is large enough, the charge collected by pads directly underneath will saturate the readout electronics; pads farther away in the distribution will not be saturated. Using these unsaturated pads and the known pad distribution function, we can estimate the charge on saturated pads, increasing the dynamic range by a factor of 5.
The CLAS12 Forward Tagger
This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.
Radiation-hard miniature optical engine with high bandwidth
Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.