Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Low Activity Waste Glass Waste Form Data Package for Hanford's Integrated Disposal Facility Performance Assessment - 16480

A Direct Feed Low Activity Waste (DFLAW) flowsheet has been initiated to begin immobilization of Hanford tank wastes. In the DFLAW configuration, a pretreatment system will segregate the high level and the low activity wastes (LAW). The LAW will be immobilized in the Waste Treatment Plant (WTP) and disposed of in Hanford's Integrated Disposal Facility (IDF). To obtain authorization to dispose of wastes in the IDF, a Performance Assessment (PA) must be completed in accordance with DOE Order 435.1. The PA shall include calculations of potential doses to representative future members of the public and potential releases from the facility to provide a reasonable expectation that performance objectives will not be exceeded as a result of operation and closure of the facility. To support the development of the PA, data from ILAW glass testing are needed to model the long term release of contaminants over the compliance period and verify that impacts to groundwater quality will be within performance objective limits. Washington River Protection Solutions is conducting an ILAW glass testing program to produce the required data. This program is a combined effort involving National Laboratories with known expertise in glass waste form research. The work involves accelerated testing to develop parameters that can be used in computer simulations of glass corrosion and contaminant release in the IDF environment. The results of this work will be compiled in an ILAW glass waste form performance data package for the IDF PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron yields for reactions induced by 120 GeV protons on thick copper target

We developed an experimental method to measure neutron energy spectrum for 120-GeV protons on a thick copper target at Fermilab Test Beam Facility (FTBF). The spectrum in the energy range from 16 to 1600 MeV was obtained for 60-cm long copper target by time-of-flight technique with an NE213 scintillator and 5.5-m flight path. Energy spectra of neutrons generated from an interaction with beam and materials are important to design shielding structure of high energy accelerators. Until now, the energy spectra for the incident energy up to 3 GeV have been measured by several groups, Ishibashi et al., Amian et al., and Leray et al. In the energy region above 3 GeV, few experimental data are available because of small number of facilities for neutron experiment. On the other hand, concerning simulation codes, theoretical models for particle generation and transportation are switched from intermediate to high energy one around this energy. The spectra calculated by the codes have not been examined using experimental data. In shielding experiments using 120 GeV hadron beam, experimental data shows systematic differences from calculations. Hagiwara et al. have measured leakage neutron spectra behind iron and concrete shield from 120 GeV proton on target at anti-proton target station in Fermilab by using Bonner Spheres with unfolding technique. In CERN, Nakao et al reported experimental results of neutron spectra behind iron and concrete wall from 120 GeV/c proton and pion mixed beam on copper by using NE213 liquid scintillators with unfolding technique. Both of the results reported systematic discrepancies between experimental and calculation results. Therefore, experimental data are highly required to verify neutron production part of calculations. In this study, we developed an experimental method to measure neutron energy spectrum for 120 GeV proton on target. The neutron energy was determined using time-of-flight technique. We used the Fermilab Test Beam Facility (FTBF) in Fermilab that provided 120 GeV proton beam with intensity of 2 x 10{sup 5}/4 sec in every minute. The point of this study was determination of experimental configuration to satisfy enough statistic and energy resolution of neutrons.

43 PARTICLE ACCELERATORS↗

Magnetic field map for T977 tertiary beam

This note describes the final magnetic field model and a simplified momentum reconstruction and its uncertainties being used for the analysis of the 2010 data for T977 (MINERvA test beam ex- periment) at the Fermilab Test Beam Facility. The results from analysis of those data are published in “MINERvA neutrino detector response measured with test beam data,” [Aliaga et al.(2015)] which has open access availability, and is also available as arXiv:1501.06431. The beamline used for this experiment was designed by MINERvA in collaboration with experts at the Fermilab Test Beam Facility. Support for constructing the beamline was provided by Fermilab, including support to MINERvA personnel and also a wide range of technical help from across Fermilab.

43 PARTICLE ACCELERATORS↗

Compact, energy EFFICIENT neutron source: enabling technology for various applications

A novel neutron source comprising of a deuterium beam (energy of about 100 KeV) injected into a tube filled with tritium gas and/or tritium plasma that generates D-T fusion reactions, whose products are 14.06 MeV neutrons and 3.52 MeV alpha particles, is described. At the opposite end of the tube, the energy of deuterium ions that did not interact is recovered. Beryllium walls of proper thickness can be utilized to absorb 14 MeV neutrons and release 2-3 low energy neutrons. Each ion source and tube forms a module. Larger systems can be formed from multiple units. Unlike currently proposed methods, where accelerator-based neutron sources are very expensive, large, and require large amounts of power for operation, this neutron source is compact, inexpensive, easy to test and to scale up. Among possible applications for this neutron source concept are sub-critical nuclear breeder reactors and transmutation of radioactive waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEVELOPMENT QUALIFICATION AND DISPOSAL OF AN ALTERNATIVE IMMOBILIZED LOW-ACTIVITY WASTE FORM AT THE HANFORD SITE

Demonstrating that a waste form produced by a given immobilization process is chemically and physically durable as well as compliant with disposal facility acceptance criteria is critical to the success of a waste treatment program, and must be pursued in conjunction with the maturation of the waste processing technology. Testing of waste forms produced using differing scales of processing units and classes of feeds (simulants versus actual waste) is the crux of the waste form qualification process. Testing is typically focused on leachability of constituents of concern (COCs), as well as chemical and physical durability of the waste form. A principal challenge regarding testing immobilized low-activity waste (ILAW) forms is the absence of a standard test suite or set of mandatory parameters against which waste forms may be tested, compared, and qualified for acceptance in existing and proposed nuclear waste disposal sites at Hanford and across the Department of Energy (DOE) complex. A coherent and widely applicable compliance strategy to support characterization and disposal of new waste forms is essential to enhance and accelerate the remediation of DOE tank waste. This paper provides a background summary of important entities, regulations, and considerations for nuclear waste form qualification and disposal. Against this backdrop, this paper describes a strategy for meeting and demonstrating compliance with disposal requirements emphasizing the River Protection Project (RPP) Integrated Disposal Facility (IDF) at the Hanford Site and the fluidized bed steam reforming (FBSR) mineralized low-activity waste (LAW) product stream.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LDRD for a high-current polarized-beam photogun

The electron accelerator driving the Ce+BAF conversion target requires a spin-polarized photogun capable of delivering a CW beam current of at least 1 mA. As the high beam current limits the useful operating time of the gun between photocathode reactivations due to ion back-bombardment, it is critical to increase the charge lifetime. A Jefferson Lab LDRD project aims to calibrate the simulation models needed to predict photocathode lifetime as a function of electrostatic optics and drive laser parameters in order to design a gun providing at least 1000 C charge lifetime. A prototype gun demonstrating the validity of the scaling predictions will be built and tested at the Gun Test Stand. I will describe the background and progress of this project and give an outlook on the expected performance.

Bruker, Max [Thomas Jefferson National Accelerator↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

The Connection between the Presence of Melanoma and Changes in Fibre Diffraction Patterns

An accurate diagnosis of melanomas at an early stage correlates directly with a better prognosis. However the incidence of melanoma is still increasing along with the number of related deaths. Melanoma cells grow extremely fast, with the result that many patients present after metastasis has occurred, too late for effective treatment. This paper describes the changes in the fibre diffraction patterns of skin that indicate the presence of a melanoma. Identification of these changes would provide an alternative early low-cost, reliable diagnostic test which could be conducted on a regular basis in local radiology facilities using rotating anode X-ray generators or as a mass screening test using suitable small angle x-ray beam-lines at synchrotrons.

43 PARTICLE ACCELERATORS↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Feasibility of Using Steel Drums for the Confinement of Burned Low-Level Radioactive Waste Ashes

The selection of suitable materials to construct a facility for the final disposal of radioactive wastes (repository) is a challenge in materials science, since these facilities must be designed to provide confinement to the radionuclides for long periods of time. In the case of the low-level radioactive waste (LLRW) repository, the confinement of the species must be guaranteed for more than 300 years. In this context, the evaluation of the proposed materials must be performed under accelerated laboratory tests. One type of LLRW consists of ashes that result from the incineration of solid combustible radioactive waste. In Argentina, one of the proposed projects is to place these ashes inside steel drums and immobilized them by a cementation process. The issue to be resolved is whether the steel drums will undergo internal corrosion depending on the presence of certain deleterious species. The aim of the present work is to evaluate the corrosion susceptibility of steel drums containing simulated cemented incineration ashes. To this purpose, a special type of specimen was designed and the corrosion process was followed up for almost 4 years. It was found that, although the deleterious effect of chloride is undeniable, corrosion rates are not as high as to compromise the integrity of the steel drums for a design period of 300 years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cu/Al Through Au Diffusion Characterized by KPFM

The nanometer scale characterization technique of Frequency Modulated Kelvin Probe Force Microscopy (FM-KPFM) will be used to assess a diffusion study on thin metal films that undergo accelerated aging. The KPFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. The KPFM technique will be exercised in an effort to explore its capacity to map surface potential contrast caused by diffusion in a manner that allows for a qualitative assessment of diffusion of Cu or Al through Au. Supporting data will be obtained from traditional techniques: AES, XPS and UPS. An aging study was conducted on thin metal test specimens comprised of 500nm Cu or Al then 500nm Au on Si. The accelerated aging process was performed under inert conditions at aging temperatures of 100°C for Cu/Au film stack and 175°C for Al/Au film stack at aging times of 8 hours, 24 hours, 96 hours (4 days), and 216 hours (9 days).A calibration method was developed using Au, Al and Cu standards to establish precision and repeatability of the KPFM technique. The average Contact Potential Difference (CPD)s and standard deviations for each metal were found and summarized. Averages from surface roughness of the AFM topography images and roughness analysis of KPFM potential images which yield an average CPD of each area of unaged vs aged coupon surfaces were compared and show trends that indicate surface chemistry.

36 MATERIALS SCIENCE↗

Formation of Imploding Plasma Liners for HEDP and MIF Application

Plasma jets with high density and velocity have a number of important applications in fusion energy and elsewhere, including plasma refueling, disruption mitigation in tokamaks, magnetized target fusion, injection of momentum into centrifugally confined mirrors, plasma thrusters, and high energy density plasmas (HEDP). In Magneto-Inertial Fusion (MIF), for example, an imploding material liner is used to compress a magnetized plasma to fusion conditions and to confine the resulting burning plasma inertially to obtain the necessary energy gain. The imploding shell may be solid, liquid, gaseous, or a combination of these states. The presence of the magnetic field in the target plasma suppresses thermal transport to the plasma shell, thus lowering the imploding power needed to compress the target to fusion conditions. This allows the required imploding momentum flux to be generated electromagnetically using off-the-shelf pulsed power technology. Practical schemes for standoff delivery of the imploding momentum flux are required and are open topics for research. One approach for accomplishing this, called plasma jet driven magneto-inertial fusion (PJMIF), uses a spherical array of pulsed plasma guns to create a spherically imploding shell of very high velocity, high momentum flux plasma. This approach requires development of plasma jet accelerators capable of achieving velocities of 50-200 km/s with very precise timing and density profiles, and with high total mass and density. Low-Z plasma jets would require the higher velocities, whereas very dense high-Z plasma shells could achieve the goal at velocities of only 50-100 km/s. In this report, we describe our work to develop the pulsed plasma gun technology needed for an experimental scientific exploration of the PJMIF concept, and also for the other applications mentioned earlier. The initial goal of a few hundred of hydrogen at 200 km/s was eventually replaced with accelerating 8000 μg of argon or xenon to 50 km/s for the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). Initial work used existing computational and analytical tools to develop and refine a specific plasma gun concept having a novel tapered coaxial electromagnetic accelerator contour with an array of symmetric ablative plasma injectors. The profile is designed to suppress the main barrier to success in coaxial guns, namely the blow-by instability in which the arc slips past and outruns the bulk of the plasma mass. Efforts to begin developing a set of annular non-ablative plasma injectors for the coaxial gun, in order to accelerate pure gases, resulted in development of linear parallel-plate MiniRailguns that turned out to work well as plasma guns in their own right and we subsequently chose them for an initial plasma liner experiment on the PLX facility at LANL. This choice was mainly driven by cost and schedule for that particular experiment, while longer term goals still projected use of coaxial guns for reactor-relevant applications for reasons of better symmetry, lower impurities, more compact plasma jet formation, and higher gun efficiency. Our efforts have focused mainly on 1) developing various plasma injection systems for both coax and linear railguns and ensuring they work reliably with the accelerator section, 2) developing a suite of plasma and gun diagnostics, 3) performing computational modeling to design and refine the plasma guns, 4) establishing a research facility dedicated to plasma gun development, and finally, 5) developing plasma guns and associated pulse power systems capable of achieving these goals and installing and testing the first two gun sets on the PLX facility at LANL. During the second funding cycle for this program, HyperV joined in a collaborative effort with LANL, the University of Alabama at Huntsville, and the University of New Mexico to perform a plasma liner experiment (PLX) to investigate the physics and technology of forming spherically imploding plasma liners. HyperV’s tasks focused on developing the plasma guns and associated pulse power systems required for the 30 gun experiment at LANL. Unfortunately, funding for the entire PLX collaborative project was terminated after only two years of the four year project due to program funding realignments which necessitated recompeting the project in midstream. Despite the loss of funding, HyperV installed two Mark1 guns and pulsed power systems on PLX, and jet characterization and merging experiments were subsequently successfully performed at LANL by the PLX Team. In parallel with those PLX experiments, HyperV continued its efforts to develop a plasma gun capable of meeting the PLX goal of 8 mg of argon at 50 km/s. HyperV was ultimately successful in this effort, demonstrating 10.8 mg at 52.8 km/s and 7.5 mg at 62.4 km/s with the Mark2 MiniRailgun.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-height seismic isolation of equipment in nuclear power plants: Numerical simulations and design recommendations

Seismic isolation can mitigate earthquake demands on safety-class equipment and is being considered for application to some advanced nuclear reactors. For tall, slender vessels that could represent an advanced reactor, a steam generator or a heat exchanger, mid-height seismic isolation has been shown to be beneficial and practical. Here, this paper focuses on numerical modeling of a mid-height isolated tall, slender vessel with two primary goals 1) investigate and quantify the benefits of mid-height seismic isolation for a range of support structure stiffnesses, isolation systems, and seismic inputs, and 2) provide analysis and design recommendations for isolation of safety-class equipment. Results of response-history analysis were in good agreement with experimental measurements and demonstrated that mid-height isolation can substantially reduce seismic demands on tall, slender vessels for a range of support structure stiffnesses, isolation systems, and seismic inputs. Importantly, the reductions in horizontal spectral accelerations in the mid-height isolated vessel from the non-isolated condition were not affected by the stiffness of the support structure. Recommendations are made for analysis and design of isolated equipment and testing of isolators used for equipment protection in nuclear facilities, which are also applicable to other industries.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visualization of water on through-plane direction of GDL using X-ray radiography

In this investigation, we visualized water distribution and behavior of water on through plane direction of GDL (Gas Diffusion Layer), which is one of components of PEMFC, using X-ray radiography. In order to investigate water distribution and behavior at GDL of PEMFC, the facilities was set up at the 7B2 beam line in Pohang Accelerator Laboratory. The phenomena of cathode side GDL is more important because the cathode side GDL has more water than the anode side. For this reason, the cathode side GDL was targeted and test section (Figure 1) was made to make similar boundary condition with a cathode side GDL of operating PEMFC. GDL faced two single channels. One is air channel as cathode gas channel of PEMFC and the other is liquid channel as cathode catalyst layer. Water is produced in cathode catalyst layer and almost of this water transport through cathode GDL. Because of this, liquid channel was adopted as catalyst layer. Images of water distribution were recorded per 4 second under various liquid pressure conditions. Water content was calculated from these images using mathematic process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary flight test results of the F100 EMD engine in an F-15 airplane

An assessment is given of results from a 17-flight evaluation of the F100 Engine Model Derivative (EMD) powerplant in an F-15 fighter. The EMD variant of the F100 engine incorporates a larger fan, a higher temperature turbine, a digital control system, and a 16-segment afterburner. These modifications result in a 15 to 20 percent increase in thrust which is exhibited in the reduction of F-15 acceleration time to Mach 2.0 by 23 percent. The only uncorrected shortcoming of the engine upon completion of the 17-flight test course was the occurrence of compressor stalls at the throttle's idle setting. These stalls had not been predicted by either ground facility tests or compressor stability assessments.

Myers, L. P.↗

Vertical drop test of a transport fuselage section located aft of the wing

A 12-foot long Boeing 707 aft fuselage section with a tapering cross section was drop tested at the NASA Langley Research Center to measure structural, seat, and occupant response to vertical crash laods and to provide data for nonlinear finite element modeling. This was the final test in a series of three different transport fuselage sections tested under identical conditions. The test parameters at impact were: 20 ft/s velocity, and zero pitch, roll, and yaw. In addition, the test was an operational shock test of the data acquisition system used for the Controlled Impact Demonstration (CID) of a remotely piloted Boeing 720 that was crash tested at NASA Ames Dryden Flight Research Facility on December 1, 1984. Post-test measurements of the crush showed that the front of the section (with larger diameter) crushed vertically approximately 14 inches while the rear crushed 18 inches. Analysis of the data traces indicate the maximum peak normal (vertical) accelerations at the bottom of the frames were approximately 109 G at body station 1040 and 64 G at body station 1120. The peak floor acceleration varied from 14 G near the wall to 25 G near the center where high frequency oscillations of the floor were evident. The peak anthropomorphic dummy pelvis normal (vertical) acceleration was 19 G's.

Fasanella, E. L.↗

Radiation Beamline Testbeds for the Simulation of Planetary and Spacecraft Environments for Human and Robotic Mission Risk Assessment

The Center for Radiation Engineering and Science for Space Exploration (CRESSE) at Prairie View A&M University, Prairie View, Texas, USA, is establishing an integrated, multi-disciplinary research program on the scientific and engineering challenges faced by NASA and the international space community caused by space radiation. CRESSE focuses on space radiation research directly applicable to astronaut health and safety during future long term, deep space missions, including Martian, lunar, and other planetary body missions beyond low earth orbit. The research approach will consist of experimental and theoretical radiation modeling studies utilizing particle accelerator facilities including: 1. NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory; 2. Proton Synchrotron at Loma Linda University Medical Center; and 3. Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory. Specifically, CRESSE investigators are designing, developing, and building experimental test beds that simulate the lunar and Martian radiation environments for experiments focused on risk assessment for astronauts and instrumentation. The testbeds have been designated the Bioastronautics Experimental Research Testbeds for Environmental Radiation Nostrum Investigations and Education (BERT and ERNIE). The designs of BERT and ERNIE will allow for a high degree of flexibility and adaptability to modify experimental configurations to simulate planetary surface environments, planetary habitats, and spacecraft interiors. In the nominal configuration, BERT and ERIE will consist of a set of experimental zones that will simulate the planetary atmosphere (Solid CO2 in the case of the Martian surface.), the planetary surface, and sub-surface regions. These experimental zones can be used for dosimetry, shielding, biological, and electronic effects radiation studies in support of space exploration missions. BERT and ERNIE are designed to be compatible with the experimental areas associated with the above facilities. CRESSE has broad expertise in space radiation in the areas of space radiation environment modeling, Monte-Carlo radiation transport modeling, space radiation instrumentation and dosimetry, radiation effects on electronics, and multi-functional composite shielding materials. The BERT and ERNIE testbeds will be utilized in individual and collaborative research incorporating this expertise. The research goal is to maximize the technical readiness level (TRL) of radiation instrumentation for human and robotic missions, optimizing the return value of CRESSE for NASA exploration and international co-operative missions. Outcomes and knowledge from research utilizing BERT and ERNIE will be applied to a variety of scientific and engineering disciplines vital for safe and reliable execution of future space exploration missions, which can be negatively impacted by the space radiation environment. The testbeds will be central to a variety of university educational activities and educational goals of NASA. Specifically, BERT and ERNIE will enhance educational opportunities in science, technology, engineering and mathematics (STEM) disciplines for engineering and science students at PVAMU, a historically black college/university. Preliminary data on prototype testbed configurations, including simulated lunar regolith (JSC-1A stimulant based on Apollo 11 samples), regolith/polyethylene composites, and dry ice, will be presented to demonstrate the usefulness of BERT and ERNIE in radiation beam line experiments.

Wilkins, Richard↗