Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Update on the Fabrication and Performance of 2-D Arrays of Superconducting Magnesium Diboride (MgB2) Thermal Detectors for Outer-Planets Exploration

Detectors with better performance than the current thermopile detectors that operate at room temperature will be needed at the focal plane of far-infrared instruments on future planetary exploration missions. We will present an update on recent results from the 2-D array of MgB2 thermal detectors being currently developed at NASA Goddard. Noise and sensitivity results will be presented and compared to thermal detectors currently in use on planetary missions.

Lakew, Brook↗

Photonic Diagnostic Technique For Thin Photoactive Films

Photonic diagnostic technique developed for use in noninvasive, rapid evaluation of thin paraelectric/ferroelectric films. Method proves useful in basic research, on-line monitoring for quality control at any stage of fabrication, and development of novel optoelectronic systems. Used to predict imprint-prone memory cells, and to study time evolution of defects in ferroelectric memories during processing. Plays vital role in enabling high-density ferroelectric memory manufacturing. One potential application lies in use of photoresponse for nondestructive readout of polarization memory states in high-density, high-speed memory devices. In another application, extension of basic concept of method makes possible to develop specially tailored ferrocapacitor to act as programmable detector, wherein remanent polarization used to modulate photoresponse. Large arrays of such detectors useful in optoelectronic processing, computing, and communication.

Thakoor, Sarita↗

Use of Photoelastic Modulators for High-accuracy Spectropolarimetric Imaging of Aerosols

Passive multiangular, multispectral, and polarimetric sensing approaches each have unique strengths for the measurement of tropospheric aerosol column abundances and microphysical properties. Current spaceborne multispectral and multiangular aerosols sensors operate at approximately 1 km resolution. Under NASA's Instrument Incubator Program, we are developing an electro-optic imaging approach that will enable adding high-accuracy polarimetry to such observations. To achieve a degree of linear polarization (DOLP) uncertainty of 0.5%, our approach temporally modulates the linear-polarization component of incoming light at a rapid rate, enabling each detector within a focal-plane array, combined with polarization analyzers, to measure the relative proportions of the linear Stokes components Q or U to the total intensity. Our system uses tandem photoelastic modulators (PEMs) within a high-reflectance, low diattenuation camera design. The two PEMs vibrate at slightly different resonant frequencies, leading to modulation of the polarized light at a heterodyne frequency of ~25 Hz. High-speed (1 kHz) readout of the detector arrays samples the output waveforms from which Q/I and U/I are derived. We report on experimental and theoretical analyses of PEM and optical system performance, along with plans for developing ruggedized PEMs capable of withstanding launch and on-orbit stresses.

photoelastics↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Focal Plane Array Shutter Mechanism of the JWST NIRSpec Detector System

This viewgraph presentation reviews the requirements, chamber location, shutter system design, stepper motor specifications, dry lubrication, control system, the environmental cryogenic function testing and the test results of the Focal Plane Array Shutter mechanism for the James Webb Space Telescope Near Infrared Spectrum Detector system. Included are design views of the location for the Shutter Mechanism, lubricant (lubricated with Molybdenum Di Sulfide) thickness, and information gained from the cryogenic testing.

Hale, Kathleen↗

A Compact, Modular Superconducting Bolometer Array Package

We have designed a detector package to house a superconducting bolometer array, SQUID multiplexers, bias and integration circuitry, optical filtering, electrical connectors, and thermal/mechanical interfaces. This package has been used successfully in the GISMO 2mm camera, a 128-pixel camera operating at a base temperature of 270mK. Operation at lower temperatures is allowed by providing direct heat sinking to the SQUIDS and bias resistors, which generate the bulk of the dissipation in the package. Standard electrical connectors provide reliable contact while enabling quick installation and removal of the package. Careful design has gone into the compensation for differing thermal expansions, the need for heat sinking of the bolometer array, and the placement of magnetic shielding in critical areas. In this presentation, we detail the design and performance of this detector package and describe its scalability to 1280- pixel arrays in the near future.

Benford, Dominic J.↗

Hard X-Ray Telescope (HXT) with Simultaneous Multiwavelength Observing from UV to 1 MeV

The scientific instrumentation associated with this study includes three coaligned telescope systems: an array of grazing incidence telescopes with graded d-spacing multilayers to enhance reflectivity above 10 keV and a compound detector in their focal planes that covers the 0.1 to 100 keV band; a single laue crystal telescope that concentrates selected narrow regions in the 150 to 1300 keV bands containing interesting lines onto a cooled segmented high energy resolution germanium detector; and an array of three small UV telescopes with detectors and filters to isolate various bands in the 1000 to 2500 A region. The principal objectives of the study is to define what technology developments are required for these instruments to be built, refine the specifications of each instrument component, and identify what type of mission is needed for an HXT observatory. One key question is whether this set of instruments should be located together as an ensemble observing simultaneously aboard a single dedicated mission or distributed among multiple missions with other instrumentation.

Goenstein, Paul↗

Photodetectors on Coronagraph Mask for Pointing Control

It has been proposed to install a symmetrical array of photodetectors about the center of the mask of a coronagraph of the type used to search for planets orbiting remote stars. The purpose of this installation is to utilize the light from a star under observation as a guide in pointing the telescope. Simple arithmetic processing of the outputs of the photodetectors would provide indications of the lateral position of the center of the mask relative to the center of the image of the star. These indications could serve as pointing-control feedback signals for adjusting the telescope aim to center the image of the star on the mask. The widths of central mask areas available for placement of photodetectors differ among coronagraph designs, typically ranging upward from about 100 m. Arrays of photodetectors can readily be placed within areas in this size range. The number of detectors in an array could be as small as 4 or as large as 64. The upper limit on the number of detectors would be determined according to the extent of the occulting pattern and the number of functionalities, in addition to pointing control, to be served by the array.

Balasubramanian, Kunjithapatham↗

Astrophysics and Technical Study of a Solar Neutrino Spacecraft: NIAC (NASA Innovative Advanced Concepts) Grant - NASA 2018-Phase-1

We report on our study of the design of a neutrino detector, shielding and veto array needed to operate a neutrino detector in space close to the Sun. This study also took into account the expected rates of Galactic gamma and cosmic rays in addition to the particles from the Sun.These preliminary studies show that we can devise a detector such that a small signal of neutrino interactions can be extracted from a large random number of events from the background sources using a double timing method from the conversion electron produced in the neutrino interaction and a secondary delayed signal from the nuclear excited state produced from the initial neutrino interaction; in our case the conversion of Ga 69 or 71 into Ge 69 or 71, but this method could apply to other nuclei with large neutrino cross sections such as Ir 115. Although these types of events need to be above 0.405 megaelectronvolt (MeV) neutrino energy and are only 66 percent of all conversion neutrino interactions on Gallium, this is a small price to pay for an increase of 10,000 by going close to the Sun to enhance the neutrino rate over the background combatorical fake-signal events. The conclusion of this Phase-1 study is very positive in that we can get the backgrounds less than 20 percent fake signals, and in addition to this we have devised another shielding method that makes the Galactic gamma-ray rate a hundred fold less which will make further improvements over these initial estimates. Although these studies are very encouraging it suggests that the next step is a NIAC Phase-II to actually build a test device,measuring basic principles such as light attention within the scintillator with high dopants and to take data in the lab with a cosmic-ray test stand and triggered X-ray source for comparison with simulated expected performance of the detector. This would be the perfect lead into a future proposal beyond a NIAC (NASA Innovative Advanced Concepts) Phase-II for a test flight of a small one-pint detector in orbit of the detector concept beyond Earth outside of the radiation belts.

Astrophysics↗

Electromagnetic Considerations for Planar Bolometer Arrays in the Single Mode Limit

Filled arrays of planar bolometers are finding astronomical applications at wavelengths as long as several millimeters. In an effort to keep focal planes to a reasonable size while maintaining large numbers of detectors, a common strategy is to push these arrays to operate close to or at the single mode limit. Doing so introduces several new challenges that are not experienced in the multi-mode case of far-infrared detectors having similar pixel sizes. First, diffractive effects of the pixels themselves are no longer insignificant and will ultimately contribute to the resolution limit of the optical system in which they reside. We use the method of Withlngton et al. (2003) to model the polarized diffraction in this limit. Second, it is necessary to re-examine the coupling between the radiation and the absorbing element that is thermally connected to the bolometers. The small f-numbers that are often employed to make use of large focal planes makes backshort construction problematic. We introduce a new strategy to increase detector efficiency that uses an antireflective layer on the front side of the detector array. In addition, typical methods for stray light control that rely on multiple reflections in a lossy medium fail due to physical size constraints. For this application, we find that resonant absorbers are a more effective strategy that can be implemented in the space available.

Wollack, Edward J.↗

NASA AMES infrared detector assemblies

Silicon: Gallium infrared detector assemblies were designed, fabricated, and tested using techniques representative of those employed for hybrid arrays to determine the suitability of this candidate technology for infrared astronomical detector array applications. Both the single channel assembly and the assembly using a 32 channel CMOS multiplexer are considered. The detector material was certified to have a boron background of less than 10 to the 13th power atoms/sq cm counter doped with phosphorus. The gallium concentration is 2 x 10 to the 16th power atoms/cu cm.

Source record↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

High Operating Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength

A barrier infrared detector with absorber materials having selectable cutoff wavelengths and its method of manufacture is described. A GaInAsSb absorber layer may be grown on a GaSb substrate layer formed by mixing GaSb and InAsSb by an absorber mixing ratio. A GaAlAsSb barrier layer may then be grown on the barrier layer formed by mixing GaSb and AlSbAs by a barrier mixing ratio. The absorber mixing ratio may be selected to adjust a band gap of the absorber layer and thereby determine a cutoff wavelength for the barrier infrared detector. The absorber mixing ratio may vary along an absorber layer growth direction. Various contact layer architectures may be used. In addition, a top contact layer may be isolated into an array of elements electrically isolated as individual functional detectors that may be used in a detector array, imaging array, or focal plane array.

Ting, David Z.↗

Small Aperture Telescopes for the Simons Observatory

The Simons Observatory (SO) is an upcoming cosmic microwave background(CMB) experiment located on Cerro Toco, Chile, that will map the microwave sky in temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO will consist of one 6-meter Large Aperture Telescope (LAT) fielding∼30,000 detectors and an array of three 0.42-meter Small Aperture Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will allow for the extremely sensitive characterization of the CMB over an-gular scales ranging from an arcmin to tens of degrees, enabling a wide range of scientific output. Here we focus on the SATs targeting degree angular scales with successive dichroic instruments observing at Mid-Frequency (MF: 93/145 GHz), Ultra-High-Frequency (UHF:225/285 GHz), and Low-Frequency (LF: 27/39 GHz). The three SATs will be able to map∼10% of the sky to a noise level of∼2 μK-arcmin when combining 93 and 145 GHz. The multiple frequency bands will allow the CMB to be separated from galactic foregrounds (primarily synchrotron and dust), with the primary science goal of characterizing the primordial tensor-to-scalar ratio, r, at a target level ofσ(r)≈0.003.

Small aperature telescope↗

Performance of the JWST/MIRI Si:As Detectors

The Mid-Infrared Instrument (MIRI) is a 5 to 28 micron imager and spectrometer that is slated to fly aboard the JWST in 2013. Each of the flight arrays is a 1024x1024 pixel Si:As impurity band conductor detector array, developed by Raytheon Vision Systems. JPL, in conjunction with the MIRI science team, has selected the three flight arrays along with their spares. We briefly summarize the development of these devices, then describe the measured performance of the flight arrays along with supplemental data from sister flight-like parts.

arsenic-doped silicon↗

CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗