Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

Status and Performance of an AGATA asymmetric detector

High-resolution gamma-ray detectors based on high-purity germanium crystals (HPGe) are one of the key workhorses of experimental nuclear science. The technical development of such detector technology has been dramatic in recent years. Large volume, high-granularity, electrically segmented HPGe detectors have been realised and a methodology to improve position sensitivity using pulse-shape analysis coupled with the novel technique of gamma-ray tracking has been developed. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of an AGATA asymmetric detector

Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4{pi} ball of germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a He{sup 3}−He{sup 4} sub Kelvin active magnetic regenerative refrigerator (AMRR) with no moving parts

Current state of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin cooling over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. We propose an active Magnetic Regenerative Refrigerator (AMRR) that uses a Superfluid Magnetic Pump (SMP) to circulate liquid He{sup 3}−He{sup 4} through a magnetic regenerator to provide the necessary cooling at sub-Kelvin temperatures. Such system will be capable of distributing the cooling load to a relatively large array of objects. One advantage of using a fluid for heat transfer in such systems is to isolate components such as the superconducting magnets from detectors that are sensitive to magnetic fields. Another advantage of the proposed tandem AMRR is that it does not need Gas Gap Heat Switches (GGHS) to transfer heat during various stages of the magnetic cooling. Our proposed system consists of four superconducting magnets, one superleak, and three heat exchangers. It will operate continuously with no moving parts and it will be capable of providing the necessary cooling at sub-Kelvin temperatures for future space science applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System for outputting a spectrum of light of a scene having optical detectors to receive light of different spectral transmittance from respective filters

Technologies pertaining to a compressive sensing snapshot spectrometer are described herein. Light is focused through an array of filters onto an array of optical detectors by way of an optical objective. Each detector in the array receives light from a single respective filter in the filters. Each filter in the filters has a spectral transmittance function that overlaps a spectral transmittance function of at least one other filter. A compressive sensing algorithm is executed over outputs of the detectors based upon the known spectral transmittance functions of the filters. Based upon the execution of the compressive sensing algorithm, intensity values of the light are identified for a number of spectral bins that is greater than a number of detectors in the array.

Shields, Eric A.↗

Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors

The Majorana Demonstrator searches for neutrinoless double-beta decay of 76 Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular detector arrays is posed by alpha particles. In the Majorana Demonstrator, events have been observed that are consistent with energy- degraded alphas originating on the passivated surface, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, charges drift through the bulk onto that surface, and then drift along it with greatly reduced mobility. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. In this contribution we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery, allowing for the efficient rejection of passivated surface alpha events in analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of OMT-Coupled Kinetic Inductance Detector for CMB Detection

Future cosmic microwave background (CMB) experiments, including the large scale ground-based Stage Four CMB Experiment (CMB-S4), satellites, and balloons, aim to map the CMB to an unprecedented precision in order to answer several key questions in cosmology. However, to reach the target noise sensitivity, more than 100,000 detectors will be needed. Arrays of kinetic inductance detectors (KIDs) are a promising alternative for experiments that require large number of detectors due to the intrinsic multiplexing capabilities. We present the fabrication procedure for a prototype planar orthomode transducer (OMT)-coupled multi-color KID array optimized for 220/270 GHz frequency bands. These devices are made from silicon-on-insulator wafers to provide a low-loss substrate for the KIDs. The OMT couples the two polarizations of light from a wide-band feedhorn to separate Nb/SiN/Nb microstrip lines, which are then coupled to Al/Nb lumped-element KIDs (LEKIDs). The silicon on the backside of the OMT is etched away using deep reactive ion etch to release the OMT membrane to enable operation over a wide bandwidth. Finally, the buried oxide is removed underneath the KID capacitors in order to minimize two-level system noise and loss mitigation. We achieved a good yield (> 80%) on our prototype devices.

47 OTHER INSTRUMENTATION↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 488: MUSiC Accomplishments and Goals [Slides]

IER-488: Measurement of Uranium Subcritical and Critical (MUSiC) consists of measurements of bare, HEU systems covering a large range of reactivities. Multiple detector systems and analysis methods are being used to obtain detector-independent results. Massive amounts of data and information available. Substantial analysis has been completed for both critical and subcritical configurations. Work in progress is largely novel research and will result in several conference proceedings, journal publications, and a subcritical benchmark. There is still a large amount of data that has not been analyzed and much more to come from the analysis of the Measurements of Uranium Subcritical and Critical.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Localization of polyhydroxybutyrate in sugarcane using Fourier-transform infrared microspectroscopy and multivariate imaging

Background: Slow-degrading, fossil fuel-derived plastics can have deleterious effects on the environment, especially marine ecosystems. The production of bio-based, biodegradable plastics from or in plants can assist in supplanting those manufactured using fossil fuels. Polyhydroxybutyrate (PHB) is one such biodegradable polyester that has been evaluated as a possible candidate for relinquishing the use of environmentally harmful plastics. Results: PHB, possessing similar properties to polyesters produced from non-renewable sources, has been previously engineered in sugarcane, thereby creating a high-value co-product in addition to the high biomass yield. This manuscript illustrates the coupling of a Fourier-transform infrared microspectrometer, equipped with a focal plane array (FPA) detector, with multivariate imaging to successfully identify and localize PHB aggregates. Principal component analysis imaging facilitated the mining of the abundant quantity of spectral data acquired using the FPA for distinct PHB vibrational modes. PHB was measured in the chloroplasts of mesophyll and bundle sheath cells, acquiescent with previously evaluated plant samples. Conclusion: This study demonstrates the power of IR microspectroscopy to rapidly image plant sections to provide a snapshot of the chemical composition of the cell. While PHB was localized in sugarcane, this method is readily transferable to other value-added co-products in different plants.

36 MATERIALS SCIENCE↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the reliability of the NIST library during routine GC-MS analyses: Structure and spectral data corroboration for 5,5-diphenyl-1,3-dioxolan-4-one during a recent OPCW proficiency test

In the field of analytical chemistry, it is the nature of the available instrumentation that makes a specific technique uniquely suited for answering a specific challenge. Often times, instruments equipped with ultrasensitive array of detectors and state-of-the-art separation components have served to highlight their invaluable role in the field. Nonetheless, it is their ultimate ability to predict the structure of an unknown material on the basis of mass spectral data that exponentially magnifies their value. Their efficacy in achieving this prediction is largely based on the size of their internal mass spectral library that conveniently can be accessed by using the software. The library can thus exhaustively correlate an unknown compound's mass spectrum to known compounds in a database and provide the analytical chemist with a probable structure for the unknown analyte. During routine analysis, it is customary that after the appropriate collection of the compound's mass spectrum, the next step involves its comparison with a compound in the instrument's National Institute of Standards and Technology (NIST) library.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt fission gamma-ray studies at DANCE

Measurements of correlated data on prompt-fission γ-rays (PFG) have been carried out for various actinide isotopes in recent years using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL). We have developed a model that conveniently parametrizes the correlated data of γ-ray multiplicity and energy. New results on two- dimensional prompt-fission γ-ray multiplicity versus energy distributions from spontaneous fission on ²⁵²Cf and neutron-induced fission on 242m Am are presented together with previously obtained results on 233,235 U and ²³⁹Pu. Correlated PFG data from ²⁵²Cf are also compared to results of the detailed theoretical model developed at LANL, for different thresholds of PFG energies. Future plans to measure correlated data on fission fragments, prompt fission neutrons and γ-rays at DANCE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗