Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Increased Subventricular Zone Radiation Dose Correlates With Survival in Glioblastoma Patients After Gross Total Resection

Purpose: Neural progenitor cells in the subventricular zone (SVZ) have a controversial role in glioblastoma multiforme (GBM) as potential tumor-initiating cells. The purpose of this study was to examine the relationship between radiation dose to the SVZ and survival in GBM patients. Methods and Materials: The study included 116 patients with primary GBM treated at the Johns Hopkins Hospital between 2006 and 2009. All patients underwent surgical resection followed by adjuvant radiation therapy with intensity modulated radiation therapy (60 Gy/30 fractions) and concomitant temozolomide. Ipsilateral, contralateral, and bilateral SVZs were contoured on treatment plans by use of coregistered magnetic resonance imaging and computed tomography. Multivariate Cox regression was used to examine the relationship between mean SVZ dose and progression-free survival (PFS), as well as overall survival (OS). Age, Karnofsky Performance Status score, and extent of resection were used as covariates. The median age was 58 years (range, 29-80 years). Results: Of the patients, 12% underwent biopsy, 53% had subtotal resection (STR), and 35% had gross total resection (GTR). The Karnofsky Performance Status score was less than 90 in 54 patients and was 90 or greater in 62 patients. The median ipsilateral, contralateral, and bilateral mean SVZ doses were 48.7 Gy, 34.4 Gy, and 41.5 Gy, respectively. Among patients who underwent GTR, a mean ipsilateral SVZ dose of 40 Gy or greater was associated with a significantly improved PFS compared with patients who received less than 40 Gy (15.1 months vs 10.3 months; P=.028; hazard ratio, 0.385 [95% confidence interval, 0.165-0.901]) but not in patients undergoing STR or biopsy. The subgroup of GTR patients who received an ipsilateral dose of 40 Gy or greater also had a significantly improved OS (17.5 months vs 15.6 months; P=.027; hazard ratio, 0.385 [95% confidence interval, 0.165-0.895]). No association was found between SVZ radiation dose and PFS and OS among patients who underwent STR or biopsy. Conclusion: A mean radiation dose of 40 Gy or greater to the ipsilateral SVZ was associated with a significantly improved PFS and OS in patients with GBM after GTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual energy CT for attenuation correction with PET/CT

Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. Methods: The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. Results: Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ∼2.6 and slightly reduced RMSE for the total image. Conclusions: When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absorbed Doses and Risk Estimates of {sup 211}At-MX35 F(ab'){sub 2} in Intraperitoneal Therapy of Ovarian Cancer Patients

Purpose: Ovarian cancer is often diagnosed at an advanced stage with dissemination in the peritoneal cavity. Most patients achieve clinical remission after surgery and chemotherapy, but approximately 70% eventually experience recurrence, usually in the peritoneal cavity. To prevent recurrence, intraperitoneal (i.p.) targeted α therapy has been proposed as an adjuvant treatment for minimal residual disease after successful primary treatment. In the present study, we calculated absorbed and relative biological effect (RBE)-weighted (equivalent) doses in relevant normal tissues and estimated the effective dose associated with i.p. administration of {sup 211}At-MX35 F(ab'){sub 2}. Methods and Materials: Patients in clinical remission after salvage chemotherapy for peritoneal recurrence of ovarian cancer underwent i.p. infusion of {sup 211}At-MX35 F(ab'){sub 2}. Potassium perchlorate was given to block unwanted accumulation of {sup 211}At in thyroid and other NIS-containing tissues. Mean absorbed doses to normal tissues were calculated from clinical data, including blood and i.p. fluid samples, urine, γ-camera images, and single-photon emission computed tomography/computed tomography images. Extrapolation of preclinical biodistribution data combined with clinical blood activity data allowed us to estimate absorbed doses in additional tissues. The equivalent dose was calculated using an RBE of 5 and the effective dose using the recommended weight factor of 20. All doses were normalized to the initial activity concentration of the infused therapy solution. Results: The urinary bladder, thyroid, and kidneys (1.9, 1.8, and 1.7 mGy per MBq/L) received the 3 highest estimated absorbed doses. When the tissue-weighting factors were applied, the largest contributors to the effective dose were the lungs, stomach, and urinary bladder. Using 100 MBq/L, organ equivalent doses were less than 10% of the estimated tolerance dose. Conclusion: Intraperitoneal {sup 211}At-MX35 F(ab'){sub 2} treatment is potentially a well-tolerated therapy for locally confined microscopic ovarian cancer. Absorbed doses to normal organs are low, but because the effective dose potentially corresponds to a risk of treatment-induced carcinogenesis, optimization may still be valuable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pore-scale intermittent velocity structure underpinning anomalous transport through 3-D porous media

We study the nature of non-Fickian particle transport in 3-D porous media by simulating fluid flow in the intricate pore space of real rock. We solve the full Navier-Stokes equations at the same resolution as the 3-D micro-CT (computed tomography) image of the rock sample and simulate particle transport along the streamlines of the velocity field. We find that transport at the pore scale is markedly anomalous: longitudinal spreading is superdiffusive, while transverse spreading is subdiffusive. We demonstrate that this anomalous behavior originates from the intermittent structure of the velocity field at the pore scale, which in turn emanates from the interplay between velocity heterogeneity and velocity correlation. Finally, we propose a continuous time random walk model that honors this intermittent structure at the pore scale and captures the anomalous 3-D transport behavior at the macroscale.

54 ENVIRONMENTAL SCIENCES↗

Contaminant Investigation and Pre‐Processing Opportunities for Textile‐To‐Textile Recycling

Millions of metric tons of textiles are landfilled or incinerated each year in the United States, with less than 1% of textiles recycled into new clothing or fabrics. To counter this trend, a growing number of companies and researchers are exploring how a circular economy can be applied to support textile‐to‐textile recycling. A significant barrier they face comes down to quickly and efficiently extracting pure feedstock material from post‐consumer garments that feature a mix of natural and synthetic fibers. Textile recyclers prefer pure feedstocks, as working with mixed sources typically means lower throughput, higher risk of equipment failure, and diminished business margins. To facilitate a circular economy for textiles, methods, and technologies are needed that can efficiently separate out materials and contaminants from end‐of‐life textiles to increase the flow of pure feedstocks to recyclers. This paper summarizes findings from interviews with a cross section of textile recyclers and from a review of literature to define basic feedstock requirements. In addition to our qualitative research, we deconstruct a bale of post‐consumer textiles and analyze them using computer‐vision imaging, Fourier transform infrared spectroscopy (FTIR), and machine learning. The resulting data are used to set system‐level design inputs for an automated contaminant removal system to process post‐consumer clothing into appropriate feedstocks for recycling. To set the system's levels for automated real‐time near‐infrared analysis, we identify the minimum percentage of primary material that any single garment in a load of used clothing must contain for the average of the full output stream to meet the target purity levels of recyclers. Here, the envisioned automated system can also address undesirable trace materials that might contaminate the processed stream by using imaging cameras coupled with artificial intelligence to identify sections of clothing for de‐trimming. Proof‐of‐concept machine learning algorithms are evaluated to locate and identify trims or garment areas with hidden contaminant materials. Integrating these methods into automated textile cutting systems can provide a cost‐effective means for increasing feedstock purity from used clothing, which can advance circularity for textiles by helping recyclers to reach production volumes and quality targets that were not possible solely with manual dismantling operations.

Parsons, Ryan [Rochester Institute of Technology, ↗

Effect of laminae count and manufacturing methods on mechanical properties of thin‐ply woven composites

Abstract Thin‐ply woven composites exhibit exceptional mechanical performance by delaying the onset of damage, making them suitable for high‐performance structural applications. This study outlines the impact of manufacturing techniques (vacuum bagging and hot pressing), ply count, and fiber waviness on the mechanical properties of aromatic thermosetting copolyester/carbon‐fiber (ATSP/CF) composites. The analysis encompasses several different ply counts, evaluating their effects on the in‐plane elastic modulus (0°–90°) and tensile strength. Results demonstrate that reducing the waviness (or crimp) ratio significantly enhances the in‐plane elastic modulus, with improvements up to 188%, highlighting the importance of fiber alignment. Vacuum bagging produced ply thicknesses from 128 to 58 μm for 1–36 plies, with in‐plane elastic moduli from 30.3 to 87.2 GPa, and 4‐ and 8‐ply samples showed approximately 40% higher stiffness than those made by hot pressing. ATSP resin with high thermal stability (up to 400°C) and recyclability was used. Furthermore, this study highlights the microstructural enhancements achieved through vacuum bagging, as revealed by scanning electron and optical microscopy, and micro‐computed tomography imaging. This paper provides insights into damage mitigation and achieving enhanced mechanical properties by controlling fiber waviness using vacuum bagging and higher ply count in thin‐ply ATSP/CF composites. Highlights Crimp ratio reduction enhances elastic in‐plane elastic modulus up to 188%. Vacuum bagging increases modulus over the hot pressing manufacturing method by 40%. Lowering thickness‐per‐ply increases failure strain from 0.8% to 1.2%. Explored the performance of a novel ATSP matrix with high recyclability and thermal stability.

Kushwaha, Shashank [The Grainger College of Engine↗

High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 {+-} 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 {+-} 2.5 min. Mean absolute increase in FLR volume was 68.9% {+-} 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolotherapy with N-Butyl Cyanoacrylate for Ectopic Varices

PurposeTo address technical feasibility and clinical outcome of transcatheter embolotherapy with N-butyl cyanoacrylate (NBCA) for bleeding ectopic varices.MethodsThe institutional review board approved this retrospective study and waived informed consent. From January 2004 to June 2013, a total of 12 consecutive patients received transcatheter embolotherapy using NBCA for bleeding ectopic varices in our institute. Clinical and radiologic features of the endovascular procedures were comprehensively reviewed.ResultsPreprocedural computed tomography images revealed ectopic varices in the jejunum (n = 7), stoma (n = 2), rectum (n = 2), and duodenum (n = 1). The 12 procedures consisted of solitary embolotherapy (n = 8) and embolotherapy with portal decompression (main portal vein stenting in 3, transjugular intrahepatic portosystemic shunt in 1). With regard to vascular access, percutaneous transhepatic access (n = 7), transsplenic access (n = 4), and transjugular intrahepatic portosystemic shunt tract (n = 1) were used. There was no failure in either the embolotherapy or the vascular accesses (technical success rate, 100 %). Two patients died within 1 month from the procedure from preexisting fatal medical conditions. Only one patient, with a large varix that had been partially embolized by using coils and NBCA, underwent rebleeding 5.5 months after the procedure. The patient was retreated with NBCA and did not undergo any bleeding afterward for a follow-up period of 2.5 months. The remaining nine patients did not experience rebleeding during the follow-up periods (range 1.5–33.2 months).ConclusionTranscatheter embolotherapy using NBCA can be a useful option for bleeding ectopic varices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Shallow and Deep Learning Methods on Classifying the Regional Pattern of Diffuse Lung Disease

This study aimed to compare shallow and deep learning of classifying the patterns of interstitial lung diseases (ILDs). Using high-resolution computed tomography images, two experienced radiologists marked 1200 regions of interest (ROIs), in which 600 ROIs were each acquired using a GE or Siemens scanner and each group of 600 ROIs consisted of 100 ROIs for subregions that included normal and five regional pulmonary disease patterns (ground-glass opacity, consolidation, reticular opacity, emphysema, and honeycombing). We employed the convolution neural network (CNN) with six learnable layers that consisted of four convolution layers and two fully connected layers. The classification results were compared with the results classified by a shallow learning of a support vector machine (SVM). The CNN classifier showed significantly better performance for accuracy compared with that of the SVM classifier by 6–9%. As the convolution layer increases, the classification accuracy of the CNN showed better performance from 81.27 to 95.12%. Especially in the cases showing pathological ambiguity such as between normal and emphysema cases or between honeycombing and reticular opacity cases, the increment of the convolution layer greatly drops the misclassification rate between each case. Conclusively, the CNN classifier showed significantly greater accuracy than the SVM classifier, and the results implied structural characteristics that are inherent to the specific ILD patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing inference of segmentation on high-resolution images in MLExchange

MLExchange is a machine learning (ML) operations platform providing web user-interfaces (UIs) for data visualization and analysis pipelines at synchrotron facilities. Among these UIs is the segmentation app which helps synchrotron users utilize ML algorithms to automatically segment high-resolution scientific images with minimal manual annotation effort. In this work, we share code optimizations that significantly speed up the segmentation inference workflow of large data in short time. By optimizing the sequence of CPU-GPU data transfers and introducing CPU parallelization to key operations, we improve the per-device, per-image frame computational efficiency and observe close to 3×$$\times$$ speedup over the original segmentation inference workflow run time when utilizing a single GPU. Further adaptations enabling multi-GPU inference yield more than 40×$$\times$$ speedup with 100 GPUs compared to the optimized single GPU inference workflow. This acceleration of the segmentation inference workflow will provide MLExchange users with easy access to segmentation results with little wait time.

Lu, Shizhao↗

Computer Model Calibration Based on Image Warping Metrics: An Application for Sea Ice Deformation

Arctic sea ice plays an important role in the global climate. Sea ice models governed by physical equations have been used to simulate the state of the ice including characteristics such as ice thickness, concentration, and motion. More recent models also attempt to capture features such as fractures or leads in the ice. These simulated features can be partially misaligned or misshapen when compared to observational data, whether due to numerical approximation or incomplete physics. In order to make realistic forecasts and improve understanding of the underlying processes, it is necessary to calibrate the numerical model to field data. Traditional calibration methods based on generalized least-square metrics are flawed for linear features such as sea ice cracks. We develop a statistical emulation and calibration framework that accounts for feature misalignment and misshapenness, which involves optimally aligning model output with observed features using cutting-edge image registration techniques. Here, this work can also have application to other physical models which produce coherent structures.

54 ENVIRONMENTAL SCIENCES↗

Biophysical Perspective on the Cellulosome: New Opportunities for Biomass Conversion

The cellulosome is a multiprotein complex, produced primarily by anaerobic microorganisms, which functions to degrade lignocellulosic materials. An important topic of current debate is whether cellulosomal systems display greater ability to deconstruct complex biomass materials (e.g. plant cell walls) than nonaggregated enzymes, and in so doing would be appropriate for improved, commercial bioconversion processes. To sufficiently understand the complex macromolecular processes between plant cell wall polymers, cellulolytic microbes, and their secreted enzymes, a highly concerted research approach is required. Adaptation of existing biophysical techniques and development of new science tools must be applied to this system. This review focuses on strategies likely to permit improved understanding of the bacterial cellulosome using biophysical approaches, with emphasis on advanced imaging and computational techniques.

09 BIOMASS FUELS↗

Uncertainty quantification and propagation in lithium-ion battery electrodes using bayesian convolutional neural networks

The complex nature of manufacturing processes stipulates electrodes to possess high variability with increased heterogeneity during production. X-ray computed tomography imaging has proved to be critical in visualizing the complicated stochastic particle distribution of as-manufactured electrodes in lithium-ion batteries. However, accurate prediction of their electrochemical performance necessitates precise evaluation of kinetic and transport properties from real electrodes. Image segmentation that characterizes voxels to particle/pore phase is often meticulous and fraught with subjectivity owing to a myriad of unconstrained choices and filter algorithms. Here we utilize a Bayesian convolutional neural network to tackle segmentation subjectivity and quantify its pertinent uncertainties. Otsu inter-variance and Blind/Referenceless Imaging Spatial Quality Evaluator are used to assess the relative image quality of grayscale tomograms, thus evaluating the uncertainty in the derived microstructural attributes. We analyze how image uncertainty is correlated with the uncertainties and magnitude of kinetic and transport properties of an electrode, further identifying pathways of uncertainty propagation within microstructural attributes. The coupled effect of spatial heterogeneity and microstructural anisotropy on the uncertainty quantification of transport parameters is also understood. This work demonstrates a novel methodology to extract microstructural descriptors from real electrode images through quantification of associated uncertainties and discerning the relative strength of their propagation, thus facilitating feedback to manufacturing processes from accurate image based electrochemical simulations.

25 ENERGY STORAGE↗

CO 2 storage in the Paluxy formation at the Kemper County CO 2 storage complex: Pore network properties and simulated reactive permeability evolution

The Paluxy formation is being considered as a prospective CO 2 reservoir at the Kemper County CO 2 Storage Complex. Herein, the pore and pore-throat size distributions and connectivity of the Paluxy formation is evaluated through analysis of 3D X-ray Computed Tomography images. In spite of resolution limitations that constrain the pore-throat sizes detectable by imaging, the permeability contributing pore-throats are successfully characterized through 3D imaging analysis. Image-obtained pore and pore-throat size distributions and pore connectivity are then utilized to construct pore network models and simulate permeability. After CO 2 is injected, it will dissolve into formation brine and create conditions favorable for dissolution of primary minerals and precipitation of secondary minerals. These reactions will alter the porosity and permeability of the system to varying degrees depending on the spatial location of reactions. In this research, the possible porosity-permeability evolution is simulated using pore network models considering mineral reactions occurring uniformly and non-uniformly throughout the network. For a given change in porosity, there is a large range of possible permeability outcomes. Depending on the extent and spatial location of mineral reactions, permeability may decrease by more than one order of magnitude as minerals precipitate. During dissolution, simulated permeability increases as much as 500%.

03 NATURAL GAS↗