Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Spatial Description of Lithium Plating

Fast charging lithium ion batteries is a critical obstacle to overcome before widespread uptake of electric vehicles. During fast charging, lithium ion batteries in electric vehicles degrade at an accelerated rate, which is frequently caused by lithium plating. In this presentation, three different methods to spatially and temporally detect and quantify lithium plating are presented; notably, mass spectroscopy titration, operando depth profiling X-ray diffraction, and in-situ X-ray diffraction mapping of pouch cells. Each of the tree techniques successfully quantify lithium plating and provide insight into its spatial occurrence within lithium ion cells.

47 OTHER INSTRUMENTATION↗

Generation of discrete scattering cross sections and demonstration of Monte Carlo charged particle transport in the Milagro IMC code package

A new method for generating discrete scattering cross sections to be used in charged particle transport calculations is investigated. The method of data generation is presented and compared to current methods for obtaining discrete cross sections. The new, more generalized approach allows greater flexibility in choosing a cross section model from which to derive discrete values. Cross section data generated with the new method is verified through a comparison with discrete data obtained with an existing method. Additionally, a charged particle transport capability is demonstrated in the time-dependent Implicit Monte Carlo radiative transfer code package, Milagro. The implementation of this capability is verified using test problems with analytic solutions as well as a comparison of electron dose-depth profiles calculated with Milagro and an already-established electron transport code. An initial investigation of a preliminary integration of the discrete cross section generation method with the new charged particle transport capability in Milagro is also presented. (authors)

97 MATHEMATICS AND COMPUTING↗

A new set-up for in-situ probing of radiation effects in materials and electronic devices

The micro-probe facility installed at the Van de Graff accelerator at CTN/IST permits simultaneous measurements of Rutherford Backscattering Spectrometry (RBS), Particle Induced X-ray Emission (PIXE) and Iono-Luminescence (IL). Here we present a recent up-grade of the measurement chamber allowing improved optical sensitivity in IL measurements and opening the possibility to perform simultaneously electrical measurements. Combinations of all these characterization techniques make this setup a powerful tool to characterize and modify different materials with spatial resolution. In particular, it can be used to study radiation effects in different materials and electronic devices in-situ. IL is a luminescence technique that uses the ion beam as the excitation source. Compared with other luminescence techniques with spatial resolution like Cathodoluminescence, this technique has the advantage to probe deeper regions of the sample, several microns below the surface. The same ion beam used to produce luminescence, can create a high density of defects, in a controllable way and the new set-up allows monitoring optical and electrical properties in realtime. In this work we combine IL with I-V curve measurements to assess the response of Ga{sub 2}O{sub 3} and GaN to proton irradiation. Ga{sub 2}O{sub 3} and GaN are emerging materials for applications in high power electronics and are considered for radiation resistant electronics. We will present a systematic study of the changes in IL and conductivity in Ga{sub 2}O{sub 3} and GaN samples with the energy of the ion beam and with the time of exposure. In particular, it was observed that during the irradiation some luminescence bands related with intrinsic point defects decrease while other new bands appear. Simulations using the SRIM code were used to determine the depth profiles of ionization and displacement events, helping to correlate the optical and electrical response of the materials with certain radiation effects. These studies show the potentialities of measuring simultaneously IL and electrical conductivity and how these two characterization techniques can work as a sensitive tool to detect and quantify radiation effects. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Ion and Neutron Irradiations to 3 dpa at 500 deg. C in Ferritic-Martensitic Alloys

The growing global demand for energy will increasingly call upon advanced nuclear fission reactors to supply safe and reliable electricity. The structural and fuel cladding components of these reactors will be subject to extreme conditions of irradiation damage up to several hundred displacements per atom (dpa) at temperatures as high as 700 deg. C. Ferritic-martensitic (F-M) steels are leading candidates for these challenging conditions due to their strength and dimensional stability under irradiation. In order to accelerate the process for evaluating F-M alloys, charged particles are increasingly being used to emulate neutron irradiations. Charged particle irradiations allow the possibility of conducting irradiation experiments within a shorter time period (i.e. at a rate up to 4 orders of magnitude faster) and with minimal radioactivation of the material, enabling lower cost and faster turnaround of post irradiation examination and analysis. However, the irradiation dose rate, damage cascade morphologies, and irradiation damage depth profiles all differ widely between protons, heavier ions, and neutrons. Currently, there is limited understanding of the significance of these physical differences and how they manifest in the irradiated microstructure and mechanical properties of F-M steels. The objective of this study is to evaluate charged particles as a surrogate for neutron irradiations in F-M alloys by assessing common irradiation conditions using Fe{sup ++} ions, protons, and neutrons. Keeping the temperature and dose consistent enables isolation of the effects of each irradiating particle and their respective dose rates and cascade morphologies. Specimens of HCM12A and HT9 were irradiated separately with protons, self-ions, and neutrons to a common dose of 3 dpa at 500 deg. C. The microstructure of each specimen was characterized with TEM and LEAP and compared to evaluate proton and self-ion irradiation as a surrogate for neutron irradiation at these conditions. - Proton, self-ion, and neutron irradiations produced consistent sizes and number densities of grains, carbides, dislocation lines, and dislocation loops. Voids were absent in all conditions. The charged particle irradiations have successfully reproduced the neutron irradiation results for these microstructural features without a temperature shift. - Nano-cluster evolution of Si-Mn-Ni-P and Cu-rich clusters was markedly different for each irradiating particle type. Some cluster morphology trends could be explained by differences in cascade volume for differing irradiating species. But dose rate likely also influences cluster evolution. - Cr-rich nanoclusters nucleated only in the neutron-irradiated HCM12A and HT9. This is likely due to thermal aging at 500 deg. C over a longer experimental time, as compared to the proton and self-ion irradiations. (authors)

36 MATERIALS SCIENCE↗

Wash Penalty Factors: Insight into the Effects of Water Wash Down of Building Materials for Radionuclide/Nuclear (Rn) Decontamination - 20153

The release of radiological material to the urban environment can have a devastating socio-economic impact. In an urban release scenario, areas around the dispersal epicenter and any areas contaminated via atmospheric deposition may require extensive decontamination. Most recently, our group reported the decontamination efficacy of pressurized water washing of common porous building materials, and compared the penetration depth of the contaminations before and after exposure to pressurized tap water. Here, we continue evaluation of the decontamination efficacy of wash solutions based on potassium (K{sup +}) salt for cesium (Cs), strontium (Sr), and europium (Eu) contaminations on common building surfaces. The surfaces included: the cement used in concrete, the aggregate used in concrete, intact concrete, roadway asphalt, asphalt shingles, and latex paint. We deposited solutions of {sup 137}Cs, {sup 85}Sr, and {sup 152}Eu onto numerous common building materials and exposed these materials to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. To aid in these analyses, we introduced a 'wash penalty factor' to quantify the degree to which contamination migrated into the bulk material by the action of the wash method. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Cs{sup +} bonded to negative charge sites on the surface of the mineral aggregate (used in concrete) so decontamination was improved by ion exchange with K{sup +}. Sr{sup 2+} is soluble and removed by water, while not bonding to aggregate or demonstrating solubility in the liquid asphalt. Eu{sup 3+} is precipitated and not removed in gentle wash but displays mobility within the pore space that suggests its presence as a colloid. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for {sup 137}Cs and {sup 152}Eu and 50- 80% for {sup 85}Sr. On concrete, Cs{sup +} bonds similarly to asphalt. Sr{sup 2+} bonds to the cement or precipitates from the alkaline pore water. Eu{sup 3+} sorbs to the cement and then precipitates. In brick, the results for Cs{sup +} and Sr{sup 2+} suggested that diffusion of ions from deeper in the coupon was important. Eu{sup 3+} is removed poorly due to precipitation. We will explain and report example wash penalty factors that vary from 0 to > 1 for the various methods and the implications for deciding when to implement wash down methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Growth of Native Oxides of Niobium Thin Films for Superconducting Qubits with Etching Chemistry

Niobium thin films have been broadly applied in building superconducting qubits for quantum computing hardware. While improvements have been made by device engineering efforts, scaling the energy-sensitive quantum system requires materials study for further improvements. In this study, we performed XPS and ToF-SIMS analysis for Nb thin films across samples with different manufacturing techniques. By varying the air exposure time of the samples, this research comparatively investigates the chemical and depth profile of native oxides before and after the etching process. We observe a rapid logarithmic growth of oxide thickness across all samples and the dominant presence and growth of Niobium pentoxide in atomic percentage concentration on the surface. This comparative study provides insight into oxides mitigation strategies and correlation with qubits performance.

Lei, Zhicheng↗

Ambient Aging of Epitaxial and Polycrystalline Rhenium Thin Films

Extending the lifetime of superconducting qubits requires materials that are resistant to surface oxidation. Rhenium has emerged as one such promising candidate that forms a sub-nanometer oxide. Grain boundaries are known to promote material degradation, and thus, we compare epitaxial (single crystal, no grain boundaries) and polycrystalline (many grain boundaries) rhenium thin films after three years of ambient environmental exposure. Epitaxial rhenium remained free of undesired particles, while polycrystalline rhenium developed surface oxide crystallites. Surface characterization using scanning electron microscopy, energy dispersive x-ray spectroscopy, and x-ray photoelectron spectroscopy reveals localized oxygen and nitrogen enrichment, together with a Re⁷⁺ oxidation state in the polycrystalline surface particles, consistent with the proposed formation of ammonium perrhenate. Epitaxial rhenium demonstrated greater resistance to aging and oxidation, making it a more promising candidate for superconducting qubits. Ongoing cleaning and XPS depth profiling will further determine the identity and origin of the surface crystallites.

Wiacek, Wiktoria [Fermilab]↗

Ambient Aging of Epitaxial and Polycrystalline Rhenium Thin Films

Extending the lifetime of superconducting qubits requires materials that are resistant to surface oxidation. Rhenium has emerged as one such promising candidate that forms a sub-nanometer oxide. Grain boundaries are known to promote material degradation, and thus we compared epitaxial (single crystal, no grain boundaries) and polycrystalline (many grain boundaries) rhenium thin films after three years of ambient environmental exposure. Epitaxial rhenium remained free of undesired particles, while polycrystalline rhenium developed surface oxide crystallites. Surface characterization using scanning electron microscopy, energy dispersive x-ray spectroscopy, and x-ray photoelectron spectroscopy reveals localized oxygen and nitrogen enrichment together with a Re⁷⁺ oxidation state in the polycrystalline surface particles, consistent with the proposed formation of ammonium perrhenate. Epitaxial rhenium demonstrated greater resistance to aging and oxidation, making it a more promising candidate for superconducting qubits. Ongoing cleaning and XPS depth profiling will further determine the identity and origin of the surface crystallites.

Wiacek, Wiktoria [William Rainey Harper Coll.]↗

Critical issues in the formation of quantum computer test structures by ion implantation

The formation of quantum computer test structures in silicon by ion implantation enables the characterization of spin readout mechanisms with ensembles of dopant atoms and the development of single atom devices. We briefly review recent results in the characterization of spin dependent transport and single ion doping and then discuss the diffusion and segregation behaviour of phosphorus, antimony and bismuth ions from low fluence, low energy implantations as characterized through depth profiling by secondary ion mass spectrometry (SIMS). Both phosphorus and bismuth are found to segregate to the SiO2/Si interface during activation anneals, while antimony diffusion is found to be minimal. An effect of the ion charge state on the range of antimony ions, 121Sb25+, in SiO2/Si is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Water adsorption on alpha-Fe2O3(0001) at near ambient conditions

We have investigated hydroxylation and water adsorption on {alpha}-Fe{sub 2}O{sub 3}(0001) at water vapor pressures up to 2 Torr and temperatures ranging from 277 to 647 K (relative humidity (RH) {<=} 34%) using ambient-pressure x-ray photoelectron spectroscopy (XPS). Hydroxylation occurs at the very low RH of 1 x 10{sup -7}% and precedes the adsorption of molecular water. With increasing RH, the OH coverage increases up to one monolayer (ML) without any distinct threshold pressure. Depth profiling measurements showed that hydroxylation occurs only at the topmost surface under our experimental conditions. The onset of molecular water adsorption varies from {approx}2 x 10{sup -5} to {approx}4 x 10{sup -2}% RH depending on sample temperature and water vapor pressure. The coverage of water reaches I ML at {approx} 15% RH and increases to 1.5 ML at 34% RH.

36 MATERIALS SCIENCE↗

The use of low-energy SIMS (LE-SIMS) for nanoscale fuel cell material development

Low-energy secondary ion mass spectrometry has been used to investigate the matrix structure and interface attributes of a novel Ce0.85Sm0.15O2/CeO2 multilayer fuel cell material. Nanoscale oxide systems have shown enhanced ionic conductivities when produced to form highly oriented epitaxial structures. The Sm-doped CeO2 material system is of particular interest for fuel cell technology because of its inherently high ionic conductivity at low operating temperatures (600-800 C). For this study, a nanometer-scale Ce0.85Sm0.15O2/CeO2 multilayer was grown by pulsed laser deposition. The sample was annealed at 700 C in an oxygen ambience. High-resolution, low-energy depth profiling using Cs revealed some diffusion of the multilayer structure after annealing, along with a possible volume change for the Sm-doped layers. Changes in layer volume will lead to an increase in the mechanical strain and may cause the material to crack. The findings presented here suggest that the Ce0.85Sm0.15O2/CeO2 multilayer structure in its current form may not possess the level of thermal stability required for use within a fuel cell environment.

30 DIRECT ENERGY CONVERSION↗

Lidar Ratios for Dust Aerosols Derived From Retrievals of CALIPSO Visible Extinction Profiles Constrained by Optical Depths from MODIS-Aqua and CALIPSO/CloudSat Ocean Surface Reflectance Measurements

CALIPSO's (Cloud Aerosol Lidar Infrared Pathfinder Satellite Observations) analysis algorithms generally require the use of tabulated values of the lidar ratio in order to retrieve aerosol extinction and optical depth from measured profiles of attenuated backscatter. However, for any given time or location, the lidar ratio for a given aerosol type can differ from the tabulated value. To gain some insight as to the extent of the variability, we here calculate the lidar ratio for dust aerosols using aerosol optical depth constraints from two sources. Daytime measurements are constrained using Level 2, Collection 5, 550-nm aerosol optical depth measurements made over the ocean by the MODIS (Moderate Resolution Imaging Spectroradiometer) on board the Aqua satellite, which flies in formation with CALIPSO. We also retrieve lidar ratios from night-time profiles constrained by aerosol column optical depths obtained by analysis of CALIPSO and CloudSat backscatter signals from the ocean surface.

Young, Stuart A.↗

Microdosimetry of proton and carbon ions

Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u{sup 12}C ion beams in small volumes of diameters 10–100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10–100 nm, dose distributionsyd(y) in lineal energy y, and dose-mean lineal energies y{sup ¯}{sub D}. For monoenergetic ions, the y{sup ¯}{sub D} was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the y{sup ¯}{sub D} depth profile for the 160 MeV proton beam was located at ∼0.5 cm behind the Bragg peak maximum, while the y{sup ¯}{sub D} peak of the 290 MeV/u {sup 12}C beam coincided well with the peak of the absorbed dose profile. Differences between the y{sup ¯}{sub D} and dose-averaged linear energy transfer (LET{sub D}) were large in the proton beam for both target volumes studied, and in the {sup 12}C beam for the 10 nm diameter cylindrical volumes. The y{sup ¯}{sub D} determined for 100 nm diameter cylindrical volumes in the {sup 12}C beam was approximately equal to the LET{sub D}. The contributions from secondary particles to the y{sup ¯}{sub D} of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1–6 in the {sup 12}C beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRD-04: Development of a Secondary MU Calculation Tool for An Integrated MR-LINAC

Purpose: To develop a fast secondary MU calculation tool for an integrated MR-Linac, an emerging technology for delivering image-guided on-line adaptive therapy. Methods: A software tool was developed to implement a modified Clarkson integration algorithm for point-dose calculation, considering the dosimtric effect of a magnetic field. A research planning system, considering the presence of a perpendicular 1.5 T magnetic field, was used to extract the beam data (e.g., depth doses and beam profiles) required for the MU calculation in homogeneous phantom of 60×60×40 cm3 for a prototype of MR-Linac integrating a 1.5 T MR scanner with 6MV photon beams. These dosimetric data may be replaced with those to be collected during the commissioning measurement of the MR-Linac. Results: The presence of the magnetic field resulted in noticeable changes including (1) shifts in beam profiles for small fields (< 2×2 cm2), and (2) changes in central-axis doses when one of field edges is < 2 cm away from the central axis. For example, the maximum change in central-axis dose was up to 8% for one of the field borders with a distance away from the central axis of <1 cm. These changes are relevant for the MU calculation particularly for IMRT and VMAT, where most of segments are small. These magnetic field affected beam profiles and depth doses were included in the software tool. The MU calculations from the software tool for selective representative plans were found to agree with those from the research planning system within 10%. Conclusion: The presence of a perpendicular magnetic field results in noticeable changes in beam profiles and depth doses for small fields. These changes are included in the secondary MU calc{sup 33}u{sup 3}lation to be used as a redundancy check for an integrated MR-Linac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDP and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-386: A Monte Carlo Dose Calculation Framework for Electron Beams On Varian TrueBeam

Purpose: The design of the linac head is different for TrueBeam than Clinac, and there are differences in measured dose distributions in water phantoms between TrueBeam and Clinac for electron beams. Therefore, MC models for Clinac may not be applied directly to the Truebeam linac. The purpose of this study is to validate a Monte Carlo (MC) dose calculation framework for electron beams on Varian TrueBeam with phase space files provided by Varian. Methods: The particle histories from the phase space file were used as input for the down-stream simulation including jaws, applicators, and water phantom. MC packages BEAMnrc/DOSYXZnrc were used. The down-stream beam components were modeled according to manufacturer specifications and the dose distributions were compared with the measured data of standard cones. The measurements were performed in a water phantom with a p-type electron field diode (diameter 0.2cm) and ion chamber (CC13). Depth dose and orthogonal profiles at depths defined by R{sub 1} {sub 0} {sub 0}, R{sub 5} {sub 0}, Rp were compared. Results: Preliminary results for a 16 MeV phase space and 10x10, 15x15, and 20x20 cm{sup 2} applicator are presented. Simulations were run for a statistical uncertainty of <2% at depth of maximum dose for a voxel resolution of 0.5x0.5x0.2cm{sup 2}. Dose and range differences for the PDD profiles were within 2% and 1 mm, respectively. Dose differences within the central 80% of the beam width for the orthogonal profiles at depth of maximum dose were less than 2% for the 10x10, 15x15, and 20x20 cm{sup 2} applicator, respectively. Conclusion: Varian electron phase space files simulations are in agreement with measured commissioning data. These phase space files can be used in the simulation of TrueBeam linacs, and will provide reproducibility across publications. Analyses for all electron energies and standard applicators are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Global soil profiles indicate depth-dependent soil carbon losses under a warmer climate

Soil organic carbon (SOC) changes under future climate warming are difficult to quantify in situ. Here we apply an innovative approach combining space-for-time substitution with meta-analysis to SOC measurements in 113,013 soil profiles across the globe to estimate the effect of future climate warming on steady-state SOC stocks. We find that SOC stock will reduce by 6.0 ± 1.6% (mean±95% confidence interval), 4.8 ± 2.3% and 1.3 ± 4.0% at 0–0.3, 0.3–1 and 1–2 m soil depths, respectively, under 1 °C air warming, with additional 4.2%, 2.2% and 1.4% losses per every additional 1 °C warming, respectively. The largest proportional SOC losses occur in boreal forests. Existing SOC level is the predominant determinant of the spatial variability of SOC changes with higher percentage losses in SOC-rich soils. Our work demonstrates that warming induces more proportional SOC losses in topsoil than in subsoil, particularly from high-latitudinal SOC-rich systems.

54 ENVIRONMENTAL SCIENCES↗

Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional ''two-voltage'' method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12x12 and 20x20 cm{sup 2} field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening {<=}0.6 mm) EDR2 film results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗