Search NASA⌕ Search

SEARCH · Search NASA

Results for “device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Compact, Controlled Resistance Exercise Device

Spaceflight leads to muscle and bone atrophy. Isoinertial (free-weight) exercises provide a sufficient stimulus to elicit increases in both muscle strength and bone mineral density in Earth-based studies. While exercise equipment is in use on the International Space Station for crewmember health maintenance, current devices are too large to place in a transport vehicle or small spacecraft. Therefore, a portable computer controlled resistance exercise device is being developed that is able to simulate the inertial loading experienced when lifting a mass on Earth. This portable device weighs less than 50 lb and can simulate the resistance of lifting and lowering up to 600 lb of free-weights. The objective is to allow crewmembers to perform resistance exercise with loads capable of maintaining muscle and bone health. The device is reconfigurable and allows for the performance of typical Earth-based free-weight exercises. Forces exerted, volume of work, range of motion, time-under-tension, and speed/ acceleration of movement are recorded and can be remotely monitored to track progress and modify individual protocols based on exercise session data. A performance evaluation will be completed and data will be presented that include ground-reaction force comparisons between the device and free-weight dead-lifts over a spectrum of resistance levels. Movement biomechanics will also be presented.

Paulus, David C.↗

Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

Zhang, Ye↗

Device for Locking a Control Knob

A simple, effective, easy-to-use device locks a control knob in a set position. In the initial application for which this device was conceived, the control knob to be locked is that of a needle valve. Previously, in that application, it was necessary for one technician to hold the knob to keep the valve at the desired flow setting while another technician secured the valve with safety wire -- a time-consuming procedure. After attachment of the wire, it was still possible to turn the knob somewhat. In contrast, a single technician using the present device can secure the knob in the desired position. in about 30 seconds, and the knob cannot thereafter be turned, even in the presence of harsh vibrations, which occur during space shuttle launch. The device includes a special-purpose clamp that fits around the control knob and its shaft and that can be tightened onto the knob, without turning the knob, by means of two thumbscrews. The end of the device opposite the clamp is a tang that contains a slot that, in turn, engages a bolt that protrudes from the panel on which the control knob and its shaft are mounted.

Grom, Dave↗

Quality Control Method for a Micro-Nano-Channel Microfabricated Device

A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

Grattoni, Alessandro↗

Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy

We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability.

Porst, J. -P.↗

Use of a Frequency Divider to Evaluate an SOI NAND Gate Device, Type CHT-7400, for Wide Temperature Applications

Frequency dividers constitute essential elements in designing phase-locked loop circuits and microwave systems. In addition, they are used in providing required clocking signals to microprocessors and can be utilized as digital counters. In some applications, particularly space missions, electronics are often exposed to extreme temperature conditions. Therefore, it is required that circuits designed for such applications incorporate electronic parts and devices that can tolerate and operate efficiently in harsh temperature environments. While present electronic circuits employ COTS (commercial-off- the-shelf) parts that necessitate and are supported with some form of thermal control systems to maintain adequate temperature for proper operation, it is highly desirable and beneficial if the thermal conditioning elements are eliminated. Amongst these benefits are: simpler system design, reduced weight and size, improved reliability, simpler maintenance, and reduced cost. Devices based on silicon-on-insulator (SOI) technology, which utilizes the addition of an insulation layer in the device structure to reduce leakage currents and to minimize parasitic junctions, are well suited for high temperatures due to reduced internal heating as compared to the conventional silicon devices, and less power consumption. In addition, SOI electronic integrated circuits display good tolerance to radiation by virtue of introducing barriers or lengthening the path for penetrating particles and/or providing a region for trapping incident ionization. The benefits of these parts make them suitable for use in deep space and planetary exploration missions where extreme temperatures and radiation are encountered. Although designed for high temperatures, very little data exist on the operation of SOI devices and circuits at cryogenic temperatures. In this work, the performance of a divide-by-two frequency divider circuit built using COTS SOI logic gates was evaluated over a wide temperature range and thermal cycling to determine suitability for use in space exploration missions and terrestrial fields under extreme temperature conditions.

Patterson, Richard L.↗

Analytic Couple Modeling Introducing Device Design Factor, Fin Factor, Thermal Diffusivity Factor, and Inductance Factor

A set of convenient thermoelectric device solutions have been derived in order to capture a number of factors which are previously only resolved with numerical techniques. The concise conversion efficiency equations derived from governing equations provide intuitive and straight-forward design guidelines. These guidelines allow for better device design without requiring detailed numerical modeling. The analytical modeling accounts for factors such as i) variable temperature boundary conditions, ii) lateral heat transfer, iii) temperature variable material properties, and iv) transient operation. New dimensionless parameters, similar to the figure of merit, are introduced including the device design factor, fin factor, thermal diffusivity factor, and inductance factor. These new device factors allow for the straight-forward description of phenomenon generally only captured with numerical work otherwise. As an example a device design factor of 0.38, which accounts for thermal resistance of the hot and cold shoes, can be used to calculate a conversion efficiency of 2.28 while the ideal conversion efficiency based on figure of merit alone would be 6.15. Likewise an ideal couple with efficiency of 6.15 will be reduced to 5.33 when lateral heat is accounted for with a fin factor of 1.0.

Seebeck effect↗

Methods and Devices for Micro-Isolation, Extraction, and/or Analysis of Microscale Components

Provided herein are devices and methods for the micro-isolation of biological cellular material. A micro-isolation apparatus described can comprise a photomask that protects regions of interest against DNA-destroying illumination. The micro-isolation apparatus can further comprise photosensitive material defining access wells following illumination and subsequent developing of the photosensitive material. The micro-isolation apparatus can further comprise a chambered microfluidic device comprising channels providing access to wells defined in photosensitive material. The micro-isolation apparatus can comprise a chambered microfluidic device without access wells defined in photosensitive material where valves control the flow of gases or liquids through the channels of the microfluidic device. Also included are methods for selectively isolating cellular material using the apparatuses described herein, as are methods for biochemical analysis of individual regions of interest of cellular material using the devices described herein. Further included are methods of making masking arrays useful for the methods described herein.

Kartalov, Emil P.↗

Biomechanical Modeling of the Deadlift Exercise on the HULK Device to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures

Extended spaceflight typically results in the loss of muscular strength and bone density due to exposure to microgravity. Resistive exercise countermeasures have been developed to maintain musculoskeletal health during spaceflight. The Advanced Resistive Exercise Device (ARED) is the "gold standard" of available devices; however, its footprint and volume are too large for use in space capsules employed in exploration missions. The Hybrid Ultimate Lifting Kit (HULK) device, with its smaller footprint, is a prototype exercise device for exploration missions. This work models the deadlift exercise being performed on the HULK device using biomechanical simulation, with the long-term goal to improve and optimize astronauts' exercise prescriptions, to maximize the benefit of exercise while minimizing time and effort invested.

Countermeasures↗

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, and • a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Fiber↗

Food Sanitation Device for Use in Microgravity

EDEN is a transportation/orbital habitat that carries large amounts of crew members, food, and supplies from Earth to Mars and back, but can also act as a permanent, simulated-1g-environment space station in Martian orbit. The focus of the project is to create a temporary, but long-term living environment that focuses on human health and food production. The project is composed of four major habitable parts (in addition to other major components). Moving from the center out, the first is a central core that acts as a hub that connects to the structural spokes, the main propulsion rockets and serves as a place for other spacecraft to dock onto, in addition to housing some of the basic station control, navigation and automated computer systems. The second set of parts are the spokes that connect the ring to the central core; these are the primary structural components with elevators in the middle carrying people from the ring to the core. The ‘lower’ portions, near the ring and it’s 1g environment, also act as storage centers. The third part is the 2-story outer ring This project served as an engineering senior design project at Temple University, and as part of NASA’s eXploration and Habitation (X-Hab) 2018 Academic Innovation Challenge. The goal of the project was to design, construct, and test a device which would be used in microgravity to sanitize produce. This is part of a NASA’s effort to grow and sanitize fresh produce on the International Space Station (ISS), in order to provide more nutritious meal options to the astronauts. Our team designed a 3-D printed spherical device with UV-C LEDs lining the interior. The designed device consists of an 8” spherical chamber, 10 UV-C LEDs, and a touchscreen user interface to control the device. Our design meets the project requirements by offering several features: a simple user interface, minimal crew time to operate, no waste produced, and the ability to sanitize multiple types of produce. The main reductions in Salmonella bacteria and Aspergillus Flavus mold were not verified. However, the aerobic plate count requirement was greatly exceeded and validated. Testing of the device resulted in visual results confirming significant decrease in E. coli activity with increased UV-C exposure, as well as quantitative results confirming significant reduction in CFU/g for the aerobic plate count. These reductions achieved from 1.464 x 10 7 to 2 x 10 4 CFU/g (2.86 log reduction) after 5 minutes, were significantly more than the requirements given by NASA ( of the craft, which holds all of the food production along with medical bays, a control center and a few parks. This ring also integrates the rigid keystone modules, which are the interface between the spokes, the expandable-construction portions of the ring and the habitation pods. The keystone modules also incorporate redundant, distributed ECLSS systems, medical storage, airlocks, and other integral station functions. The last parts are the habitation pods; these hold the sleeping quarters along with the bathrooms, showers, kitchen space and lounge areas. These expandable modules latch onto the keystone modules of the ring, which serves as a circulatory link between the different habitation pods.

Damien Gordon↗

Device for wavelength-selective imaging

An imaging device captures both a visible light image and a diagnostic image, the diagnostic image corresponding to emissions from an imaging medium within the object. The visible light image (which may be color or grayscale) and the diagnostic image may be superimposed to display regions of diagnostic significance within a visible light image. A number of imaging media may be used according to an intended application for the imaging device, and an imaging medium may have wavelengths above, below, or within the visible light spectrum. The devices described herein may be advantageously packaged within a single integrated device or other solid state device, and/or employed in an integrated, single-camera medical imaging system, as well as many non-medical imaging systems that would benefit from simultaneous capture of visible-light wavelength images along with images at other wavelengths.

Frangioni, John V↗

Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture

Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture are described. In one aspect, a communications device identification method includes providing identification information regarding a group of wireless identification devices within a wireless communications range of a reader, using the provided identification information, selecting one of a plurality of different search procedures for identifying unidentified ones of the wireless identification devices within the wireless communications range, and identifying at least some of the unidentified ones of the wireless identification devices using the selected one of the search procedures.

47 OTHER INSTRUMENTATION↗

Radioisotope Detection Device and Methods of Radioisotope Collection

A device for collection of radionuclides includes a mixture of a polymer, a fluorescent organic scintillator and a chemical extractant. A radionuclide detector system includes a collection device comprising a mixture of a polymer, a fluorescent agent and a selective ligand. The system includes at least one photomultiplier tube (PMT). A method of detecting radionuclides includes providing a collector device comprising a mixture comprising a polymer, a fluorescent organic scintillator and a chemical extractant. An aqueous environment is exposed to the device and radionuclides are collected from the environment. Radionuclides can be concentrated within the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar electrochemical device assembly

A pre-fabricated electrochemical device having a dense electrolyte disposed between an anode and a cathode preferably deposited as thin films is bonded to a porous electrically conductive support. A second porous electrically conductive support may be bonded to a counter electrode of the electrochemical device. Multiple electrochemical devices may be bonded in parallel to a single porous support, such as a perforated sheet to provide a planar array. Planar arrays may be arranged in a stacked interconnected array. A method of making a supported electrochemical device is disclosed wherein the method includes a step of bonding a pre-fabricated electrochemical device layer to an existing porous metal or porous metal alloy layer.

Jacobson, Craig P.↗

Device for cutting protrusions

An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

47 OTHER INSTRUMENTATION↗

Interfacial modifications in organic optoelectronic devices.

In the past decade, organic optoelectronic devices have made much advances that they become viable technologies. These organic optoelectronic devices involve integration of organics with highly dissimilar materials, e.g. metals, semiconductors, and oxides, with critical device actions taking places at the organic-inorganic interfaces. For examples, in organic photovoltaics, exciton dissociation and carrier separation occur at the donor-acceptor heterojunctions; careful design of junction area and band alignment is critical for optimizing device performance. In this talk, I will show two examples of modifying organic-inorganic interfaces with alkanethiol self-assembled monolayers (SAMs) to improve device performance. Alkanethiols are large band gap molecules that are expected to act as a transport barrier. When the Au cathode in polyfluorene OLEDs is modified with alkanethiol SAMs, the current is found to be lower while the output luminescent intensity higher, leading to higher external quantum efficiency at a given current density. In ZnO-polythiophene hybrid solar cells, increasing alkanethiol SAM length surprisingly leads to higher photocurrent, despite the SAM reduces electron transfer. I will discuss the mechanisms behind these unexpected improvements.

14 SOLAR ENERGY↗

Unproven screening devices threaten the lives of police and military.

In a world plagued with improvised explosive devices, drugs and dangerous people, the desire to field technology to protect our police and military is providing a fertile market for the proliferation of protection technologies that range from the unproven to the disproven. The market place is currently being flooded with detection equipment making inflated and inaccurate marketing claims of high reliably, high detection probabilities, and ease of operation - all while offering detection capabilities at safe distances. The manufacturers of these devices have found a willing global marketplace, which includes some of the most dangerous places in the world. Despite a wealth of contradictory performance and testing data available on the Internet, sales of these devices remain brisk and profitable. Rather than enhancing the security of police and military personnel, the reliance on these unproven and disproven devices is creating a sense of false security that is actually lowering the safety of front-line forces in places like Iraq and Afghanistan. This paper addresses the development and distribution history of some of these devices and describes the testing performed by Sandia National Laboratories in Albuquerque, and other reputable testing agencies that illustrate the real danger in using this kind of unproven technology.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗