Search NASA⌕ Search

SEARCH · Search NASA

Results for “device packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Proof-of-principle experiment for FEL-based coherent electron cooling

Coherent electron cooling (CEC) has a potential to significantly boost luminosity of high-energy, high-intensity hadron-hadron and electron-hadron colliders. In a CEC system, a hadron beam interacts with a cooling electron beam. A perturbation of the electron density caused by ions is amplified and fed back to the ions to reduce the energy spread and the emittance of the ion beam. To demonstrate the feasibility of CEC we propose a proof-of-principle experiment at RHIC using SRF linac. In this paper, we describe the setup for CeC installed into one of RHIC's interaction regions. We present results of analytical estimates and results of initial simulations of cooling a gold-ion beam at 40 GeV/u energy via CeC. We plan to complete the program in five years. During first two years we will build coherent electron cooler in IP2 of RHIC. In parallel we will develop complete package of computer simulation tools for the start-to-end simulation predicting exact performance of a CeC. The later activity will be the core of Tech X involvement into the project. We will use these tools to predict the performance of our CeC device. The experimental demonstration of the CeC will be undertaken in years three to five of the project. The goal of this experiment is to demonstrate the cooling of ion beam and to compare its measured performance with predictions made by us prior to the experiments.

43 PARTICLE ACCELERATORS↗

Coherent electron cooling demonstration experiment

Coherent electron cooling (CEC) has a potential to significantly boost luminosity of high-energy, high-intensity hadron-hadron and electron-hadron colliders. In a CEC system, a hadron beam interacts with a cooling electron beam. A perturbation of the electron density caused by ions is amplified and fed back to the ions to reduce the energy spread and the emittance of the ion beam. To demonstrate the feasibility of CEC we propose a proof-of-principle experiment at RHIC using SRF linac. In this paper, we describe the setup for CeC installed into one of RHIC's interaction regions. We present results of analytical estimates and results of initial simulations of cooling a gold-ion beam at 40 GeV/u energy via CeC. We plan to complete the program in five years. During first two years we will build coherent electron cooler in IP2 of RHIC. In parallel we will develop complete package of computer simulation tools for the start-to-end simulation predicting exact performance of a CeC. The later activity will be the core of Tech X involvement into the project. We will use these tools to predict the performance of our CeC device. The experimental demonstration of the CeC will be undertaken in years three to five of the project. The goal of this experiment is to demonstrate the cooling of ion beam and to compare its measured performance with predictions made by us prior to the experiments.

43 PARTICLE ACCELERATORS↗

Graph Neural Network-based Tracking as a Service

Recent studies have shown promising results for track finding in dense environments using Graph Neural Network (GNN)-based algorithms. However, GNN-based track finding is computationally slow on CPUs, necessitating the use of coprocessors to accelerate the inference time. Additionally, the large input graph size demands a large device memory for efficient computation, a requirement not met by all computing facilities used for particle physics experiments, particularly those lacking advanced GPUs. Furthermore, deploying the GNN-based track-finding algorithm in a production environment requires the installation of all dependent software packages, exclusively utilized by this algorithm. These computing challenges must be addressed for the successful implementation of GNN-based track-finding algorithm into production settings. In response, we introduce a ``GNN-based tracking as a service'' approach, incorporating a custom backend within the NVIDIA Triton inference server to facilitate GNN-based tracking. This paper presents the performance of this approach using the Perlmutter supercomputer at NERSC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser Safety Device

A major focus of work done at Air Products and Chemicals' Laser Application Laboratory is on use of ultraviolet radiation using high energy excimer lasers. Because light within the wavelength of excimer lasers is invisible, it can cause serious damage to eyes and tissue. To contain the laser beam, Air Products Incorporated a Jet Propulsion Laboratory invention described in a technical support package into its beam stops. The technology interrupts the laser pathway and allows workers to remain in the target area without shutting off the laser.

Source record↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

SiC vs. Si for High Radiation Environments: NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

Commercial silicon carbide and silicon Schottky barrier power diodes have been subjected to 203 MeV proton irradiation and the effects of the resultant displacement damage on the I-V characteristics have been observed. Changes in forward bias I-V characteristics are reported for fluences up to 4 x 10(exp 14) p/cm2. For devices of both material types, the series resistance is observed to increase as the fluence increases. The changes in series resistance result from changes in the free carrier concentration due to carrier removal by the defects produced. A simple model is presented that allows calculation of the series resistance of the device and then relates the carrier removal rate to the changes in series resistance. Using this model to calculate the carrier removal rate in both materials reveals that the carrier removal rate in silicon is less than that in silicon carbide, indicating that silicon is the more radiation tolerant material.

Schottky barrier power diodes↗

Diode laser absorption sensors for gas-dynamic and combustion flows

Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.

Non-NASA Center↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High finesse buckled microcavities

Optical cavities are widely used in modern science and technology to enable a wide range of both quantum and classical applications. Recently, the growing demand for miniaturization and high performance has fueled the exploration of new fabrication methods beyond traditional polishing techniques and macroscopic mirrors. Visible and near-infrared (NIR) wavelengths are particularly important for quantum applications, where achieving low-loss resonators is also more challenging than in the telecom range, presenting unique challenges and opportunities for microscopic cavity systems. Here, we present a fabrication method for making NIR microcavities using buckled dielectric membrane mirrors, achieving a record finesse of 0.9 million at 780 nm for microcavities. We demonstrated flexible device geometries—including singular mirrors and mirror arrays, featuring radii of curvature ranging from 1 to 10 mm. The fabrication process offers high uniformity, high yield, and robust performance across a wide range of cavity lengths. Additionally, we can produce easy-to-assemble microcavity packages, with a total volume of ~2(4) mm 3 , featuring optical modes with a linewidth of 5.16 MHz (570 kHz) and a free spectral range (FSR) of 3.18 THz (150 GHz). Our results extend the frontier of microcavity fabrication for classical and quantum photonic technologies.

Ding, Sophie Weiyi [Harvard Univ., Cambridge, MA (↗

A Soft-Switching Inverter for High-Temperature Advanced Hybrid Electric Vehicle Traction Motor Drives

The state-of-the-art hybrid electric vehicles (HEVs) require the inverter cooling system to have a separate loop to avoid power semiconductor junction over temperatures because the engine coolant temperature of 105°C does not allow for much temperature rise in silicon devices. The proposed work is to develop an advanced soft-switching inverter that will eliminate the device switching loss and cut down the power loss so that the inverter can operate at high-temperature conditions while operating at high switching frequencies with small current ripple in low inductance based permanent magnet motors. The proposed tasks also include high-temperature packaging and thermal modeling and simulation to ensure the packaged module can operate at the desired temperature. The developed module will be integrated with the motor and vehicle controller for dynamometer and in-vehicle testing to prove its superiority. This report will describe the detailed technical design of the soft-switching inverters and their test results. The experiments were conducted both in module level for the module conduction and switching characteristics and in inverter level for its efficiency under inductive and dynamometer load conditions. The performance will be compared with the DOE original specification.

33 ADVANCED PROPULSION SYSTEMS↗

Transistor screening evaluation SJ6708H

A manufacturer was contracted to screen 125 transistors capable of withstanding the high level inductive voltages obtained when switching inductive loads. Planned differences included a change in die bonding to comply with NASA's desire for hard solder die attachment which further necessitated a change in package to conform to the required die mounting system. Evaluation of the electrical performance and recommended changes were made during the preliminary build phase of the program. The following sections are outlined: (1) narrative outline; (2) customer data summary and X-ray reports; (3) device specification; (4) failure analysis reports; (5) test facilities list; and (6) test measurement data.

Barton, J. L.↗

Submillimeter local oscillators for heterodyne spectroscopy

The major technological innovations in continuous wave (CW) submillimeter sources which are specifically suitable for application as local oscillators in heterodyne systems are reviewed. A description of the various sources is given which underscores the general principles and operating features for each type of device. Particular emphasis is placed on CW optically pumped lasers, which have had a dramatic impact as widely available sources of narrow linewidth coherent radiation. The state-of-the-art is summarized for these lasers and performance data are presented for several local oscillator packages. Optically pumped lasers are then compared and contrasted with other competing sources such as backward wave oscillators, IMPATT diodes, and Josephson junctions. By comparing their advantages and limitations for use as local oscillators, the potential applications of these different sources are projected. The prospects for increased tunability, reliability, and scalability are briefly considered, and several novel techniques for generating partially tunable radiation using Schottky diode mixers or CW Raman lasers are highlighted.

Danielewicz, E. J., Jr.↗

Adapter for mounting a microphone flush with the external surface of the skin of a pressurized aircraft

A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.

Cohn, R. B.↗

Space Qualified 200-Watt Q-band Linearized Traveling-Wave Tube Amplifier

L3 Technologies Electron Devices Division, (L3 EDD) and L3 Technologies Narda Microwave West (L3 NMW), are completing space-flight qualification for a 200-watt Q-band linearized channelized traveling-wave tube amplifier (LCTWTA) capable of over 5 GHz instantaneous bandwidth in a conduction-cooled package. This paper will discuss the LCTWTA performance, manufacturing and flight qualification test results.

Traveling-Wave Tube Amplifier↗

Space Qualified 200-Watt Q-Band Linearized Traveling-Wave Tube Amplifier

L3 Technologies Electron Devices Division, (L3 EDD) and L3 Technologies Narda Microwave West (L3 NMW), are completing space-flight qualification for a 200-watt Q-band linearized channelized traveling-wave tube amplifier (LCTWTA) capable of over 5 GHz instantaneous bandwidth in a conduction-cooled package. This paper will discuss the LCTWTA performance, manufacturing and flight qualification test results.

Q-band↗

Microbial Air Sampler Payload - Astrobee

The following package 2020-09-28 Microbial Air Sampler folders consist of a prototype design of a microbial air sample payload to fit in the bays of Astrobee free-flyer. There are several CAD designs prototypes and documentation about the concept and the current air sampler device.

Jose Cortez↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗