Search NASA⌕ Search

SEARCH · Search NASA

Results for “environmental sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%–70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

DESI↗

Improvement of eukaryotic protein predictions from soil metagenomes

During the last decades, metagenomics has highlighted the diversity of microorganisms from environmental or host-associated samples. Most metagenomics public repositories use annotation pipelines tailored for prokaryotes regardless of the taxonomic origin of contigs. Consequently, eukaryotic contigs with intrinsically different gene features, are not optimally annotated. Using a bioinformatics pipeline, we have filtered 7.9 billion contigs from 6,872 soil metagenomes in the JGI’s IMG/M database to identify eukaryotic contigs. We have re-annotated genes using eukaryote-tailored methods, yielding 8 million eukaryotic proteins and over 300,000 orphan proteins lacking homology in public databases. Comparing the gene predictions we made with initial JGI ones on the same contigs, we confirmed our pipeline improves eukaryotic proteins completeness and contiguity in soil metagenomes. The improved quality of eukaryotic proteins combined with a more comprehensive assignment method yielded more reliable taxonomic annotation. This dataset of eukaryotic soil proteins with improved completeness, quality and taxonomic annotation reliability is of interest for any scientist aiming at studying the composition, biological functions and gene flux in soil communities involving eukaryotes.

54 ENVIRONMENTAL SCIENCES↗

Use Of The Operational Air Quality Monitor (AQM) For In-Flight Water Testing Project

A primary requirement for manned spaceflight is Environmental Health which ensures air and water contaminants, acoustic profiles, microbial flora, and radiation exposures within the cabin are maintained to levels needed for crew health and for vehicle system functionality. The reliance on ground analyses of returned samples is a limitation in the current environmental monitoring strategy that will prevent future Exploration missions beyond low-Earth orbit. This proposal attempts to address this shortcoming by advancing in-flight analyses of water and air. Ground analysis of in-flight, air and water samples typically employ vapor-phase analysis by gas chromatography-mass spectrometry (GC-MS) to identify and quantify organic compounds present in the samples. We envision the use of newly-developed direct ionization approaches as the most viable avenue leading towards an integrated analytical platform for the monitoring of water, air, and, potentially bio-samples in the cabin environment. Development of an in-flight instrument capable of analyzing air and water samples would be the logical next step to meeting the environmental monitoring needs of Exploration missions. Currently, the Air Quality Monitor (AQM) on-board ISS provides this specific information for a number of target compounds in the air. However, there is a significant subset of common target compounds between air and water. Naturally, the following question arises, "Can the AQM be used for both air and water quality monitoring?" Previous directorate-level IR&D funding led to the development of a water sample introduction method for mass spectrometry using electrothermal vaporization (ETV). This project will focus on the integration of the ETV with a ground-based AQM. The capabilities of this integrated platform will be evaluated using a subset of toxicologically important compounds.

Macatangay, Ariel↗

Total Recoverable Aluminum: Not Totally Relevant for Water Quality Standards

Abstract A large water quality data set, representing more than 100 surface-water locations sampled from 2007 to 2017 in the Los Alamos area of New Mexico, USA's Pajarito Plateau, was assembled to evaluate Al concentrations in unfiltered and filtered samples. Aluminum concentrations often exceeded United States Environmental Protection Agency (USEPA) and New Mexico ambient water quality criteria (AWQC), regardless of filter size and sample location. However, AWQC are based on laboratory toxicity studies using soluble Al salts and do not reflect natural conditions in Pajarito Plateau surface waters. The plateau is predominately covered by glassy and recrystallized volcanic ashes (e.g., Bandelier Tuff) containing colloidal to sand-sized aluminosilicates. Samples from natural background drainages and areas downstream of developed regions exhibited similar Al concentrations, suggesting that AWQC exceedances are caused by naturally elevated Al concentrations. Solubility calculations indicated that most samples were oversaturated with respect to amorphous Al(OH)3(s). Therefore, AWQC exceedances are likely artifacts of the “total recoverable” sample preparation, which includes acidification and partial digestion, thereby liberating nonbioavailable Al from aluminosilicates. Accordingly, Al concentrations were strongly associated with suspended sediment concentrations (SSCs), implying that aluminosilicates in suspended sediment contributed to AWQC exceedances and Al oversaturation. Solid-phase particle characterization, using X-ray diffraction (XRD) and scanning electron microscopy with electron dispersive spectroscopy (SEM/EDS) did not identify potentially bioavailable amorphous Al(OH)3(s) in any sample tested. Thus, current sample collection and analysis protocols should not be used to evaluate attainment of Al AWQC on the Pajarito Plateau or locations where aluminosilicates are substantial contributors to total recoverable Al. A sample preparation method (e.g., pH 4 extraction) capable of differentiating nonbioavailable and bioavailable forms of Al is recommended. Otherwise, current New Mexico and USEPA sample preparation approaches will continue to generate artifactual AWQC exceedances in surface waters that contain aluminosilicates. Integr Environ Assess Manag 2019;00:1–14. © 2019 SETAC

Ryan, Adam C.↗

Los Alamos National Laboratory support to IAEA environmental safeguards

The nuclear and radiochemistry group provides sample preparation and analysis support to the International Atomic Energy Agency (IAEA) Network of Analytical Laboratories (NWAL). These analyses include both non-destructive (alpha and gamma-ray spectrometry) and destructive (thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry) methods. On a bi-annual basis the NWAL laboratories are invited to meet to discuss program evolution and issues. During this meeting each participating laboratory summarizes their efforts over the previous two years. This presentation will present Los Alamos National Laboratories efforts in support of this program. Data showing results from sample and blank analysis will be presented along with capability enhancement and issues that arose over the previous two years.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Space Environmental Effects on Additively Manufactured (AM) Parts on MISSE-9/10

The Materials on International Space Station Experiment (MISSE) experiments have made a continuous presence on the ISS and allowed for testing of performance and durability of materials exposed to the Low Earth Orbit (LEO) space environment. Additive Manufacturing (AM) has been included on several MISSE flights, and many companies (Made in Space and Stratasys) and NASA centers wanted to test various AM material samples. The goal of studying Space Environmental Effects on AM Parts with MISSE 9/10 was to fly promising metal and polymer AM material samples (dogbones) that could have future manufacturing capabilities in space and conduct post-flight analysis of these materials via mechanical and optical properties. On these flights, MISSE-9 contained three Inconel and 12 polymer samples and MISSE-10 included three Inconel and 16 polymer samples. Before flying to the ISS, all the samples underwent thermal vacuum bakeout (at 60°C for 24 hours and 10-6 torr). After bakeout, control and flight experiments were weighed, and optical properties were taken. Optical properties such as solar absorptance and infrared emittance were taken on the control samples and the flight samples (preflight and postflight). To understand more about the mechanical properties of the AM samples, tensile testing was conducted on the samples to determine the yield and ultimate tensile strength of the dogbone samples against the control. Lastly, the torque on the fasteners securing the dogbone samples were loosened and measured using a torque wrench, and they were compared to their preflight torque specification required. Optical properties and masses were recorded before flight, and the postflight results were recorded and collected in June 2022 to study the effects. With the postflight analysis, NASA engineers can now better characterize how UV radiation and thermal cycling affect the material properties.

Materials on International Space Station Experimen↗

Materials International Space Station Experiment (MISSE): Overview, Accomplishments and Future Needs

Materials and devices used on the exterior of spacecraft in low Earth orbit (LEO) are subjected to environmental threats that can cause degradation in material properties, possibly threatening spacecraft mission success. These threats include: atomic oxygen (AO), ultraviolet and x-ray radiation, charged particle radiation, temperature extremes and thermal cycling, micrometeoroid and debris impacts, and contamination. Space environmental threats vary greatly based on spacecraft materials, thicknesses and stress levels, and the mission environment and duration. For more than a decade the Materials International Space Station Experiment (MISSE) has enabled the study of the long duration environmental durability of spacecraft materials in the LEO environment. The overall objective of MISSE is to test the stability and durability of materials and devices in the space environment in order to gain valuable knowledge on the performance of materials in space, as well as to enable lifetime predictions of new materials that may be used in future space flight. MISSE is a series of materials flight experiments, which are attached to the exterior of the International Space Station (ISS). Individual experiments were loaded onto suitcase-like trays, called Passive Experiment Containers (PECs). The PECs were transported to the ISS in the Space Shuttle cargo bay and attached to, and removed from, the ISS during extravehicular activities (EVAs). The PECs were retrieved after one or more years of space exposure and returned to Earth enabling post-flight experiment evaluation. MISSE is a multi-organization project with participants from the National Aeronautics and Space Administration (NASA), the Department of Defense (DoD), industry and academia. MISSE has provided a platform for environmental durability studies for thousands of samples and numerous devices, and it has produced many tangible impacts. Ten PECs (and one smaller tray) have been flown, representing MISSE 1 through MISSE 8, yielding long-duration space environmental performance and durability data that enable material validation, processing recertification and space qualification; improved predictions of materials and component lifetimes in space; model verification and development; and correlation factors between space-exposure and ground-facilities enabling more accurate in-space performance predictions based on ground-laboratory testing. A few of the many experiment results and observations, and their impacts, are provided. Those highlighted include examples on improved understanding of atomic oxygen scattering mechanisms, LEO coating durability results, and polymer erosion yields and their impacts on spacecraft design. The MISSE 2 Atomic Oxygen Scattering Chamber Experiment discovered that the peak flux of scattered AO was determined to be 45 deg from normal incidence, not the model predicted cosine dependence. In addition, the erosion yield (E(sub y)) of Kapton H for AO scattered off oxidized-Al is 22% of the E(sub y) of direct AO impingement. These results were used to help determine the degradation mechanism of a cesium iodide detector within the Hubble Space Telescope Cosmic Origins Spectrograph Experiment. The MISSE 6 Indium Tin Oxide (ITO) Degradation Experiment measured surface electrical resistance of ram and wake ITO coated samples. The data confirmed that ITO is a stable AO protective coating, and the results validated the durability of ITO conductive coatings for solar arrays for the Atmosphere-Space Transition 2 Explorer program. The MISSE 2, 6 and 7 Polymer Experiments have provided LEO AO Ey data on over 120 polymer and composites samples. The flight E(sub y) values were found to range from 3.05 x 10(exp -26) cu cm/atom for the AO resistant polymer CORIN to 9.14 x 10(exp -26) cu cm/atom for polyoxymethylene (POM). In addition, flying the same polymers on different missions has advanced the understanding of the AO E(sub y) dependency on solar exposure for polymers containing fluorine. The MISSE polymer results are highly requested and have impacted spacecraft design for WorldView-2 & -3, the Global Precipitation Measurement-Microwave Imager, and other spacecraft. The flight data has enabled the development of an Atomic Oxygen Erosion Predictive Tool that allows the erosion prediction of new and non-flown polymers. The data has also been used to develop a new NASA Technical Standards Handbook "Spacecraft Polymers Atomic Oxygen Durability Handbook." Many intangible benefits have also been derived from MISSE. For example, over 40 students have collaborated on Glenn's MISSE experiments, which have resulted in greater than $80K in student scholarships and awards in national and international science fairs. Students have also given presentations and won poster competition awards at international space conferences.

Flight Experiment↗

An improved empirical model of electron and ion fluxes at geosynchronous orbit based on upstream solar wind conditions

In this study, a new empirical model of the electron fluxes and ion fluxes at geosynchronous orbit (GEO) is introduced, based on observations by Los Alamos National Laboratory (LANL) satellites. The model provides flux predictions in the energy range ~1 eV to ~40 keV, as a function of local time, energy, and the strength of the solar wind electric field (the negative product of the solar wind speed and the z component of the magnetic field). Given appropriate upstream solar wind measurements, the model provides a forecast of the fluxes at GEO with a ~1 h lead time. Model predictions are tested against in-sample observations from LANL satellites and also against out-of-sample observations from the Compact Environmental Anomaly Sensor II detector on the AMC-12 satellite. The model does not reproduce all structure seen in the observations. However, for the intervals studied here (quiet and storm times) the normalized root-mean-square deviation < ~0.3. It is intended that the model will improve forecasting of the spacecraft environment at GEO and also provide improved boundary/input conditions for physical models of the magnetosphere.

58 GEOSCIENCES↗

Minimization of the auxiliary reagent loading for direct arylation polymerization (DArP) of 2‐bromo‐3‐hexylthiophene

ABSTRACT In this work, we present a powerful set of synthetic strategies aimed at minimization of auxiliary reagent loading for direct arylation polymerization (DArP) of 2‐bromo‐3‐hexylthiophene. As such, we report efficient lowering of Pd(OAc) 2 catalyst loading as well as loading of other auxiliary reagents, such as neodecanoic acid and N , N ‐dimethylacetamide. Unprecedented low loadings of catalyst down to 0.0313% (313 ppm) were achieved, while producing polymer in high yield (91% after Soxhlet extraction), with a high molecular weight (24.2 kDa) and carefully controlled chemical structure thus making the optimized DArP protocol significantly more cost‐effective, convenient, sustainable, and environmentally friendly. The resulting polymer samples were thoroughly investigated in terms of their chemical structure as well as optical, thermal, chain ordering and electronic properties using GPC analysis, 1 H NMR, MALDI, UV–vis, GIXRD spectroscopy, DSC, and SCLC hole mobility measurements. The results demonstrate that the reagent lowering strategies increase the polymer regioregularity from 94.6 to 96.5% as evidenced by 1 H NMR spectra and corroborated by GIXRD, DSC, and UV–vis measurements. Additionally, polymer samples obtained at low reagent loading are more uniformly proton‐terminated as evidenced by 1 H NMR and MALDI end‐group analysis. © 2015 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2015 , 53 , 1492–1499

Rudenko, Andrey E.↗

Indentation size effect in unirradiated and ion-irradiated 800H steel at high temperatures

Nanoindentation is a widespread and useful method for evaluating mechanical properties at the sub-micron length scale. However, the indentation size effect remains a major obstacle to obtain meaningful macroscopic mechanical properties from small volume testing. Here, this work systematically addresses the Indentation Size Effect (ISE) phenomenon as a function of temperature and defect density in an austenitic Fe-Cr-Ni alloy (800H) to establish the baseline for nanoindentation testing of ion-irradiated alloys in environmental conditions. The 800H steel sample was irradiated with 70 MeV Fe 9+ at 450 °C to the total dose of 20.68 dpa. All samples were tested up to 300 °C in order to quantify the effect of temperature on the indentation size effect. It was found that in all cases, the ISE is less pronounced at high temperatures due to the increase of the plastic zone size. For the same grain orientation, the ISE is less pronounced in the irradiated 800H at all temperatures.

36 MATERIALS SCIENCE↗

Experimental determination of Zn isotope fractionation during evaporative loss at extreme temperatures

We report that zinc isotopes fractionate during evaporation, and thus can potentially be used to calculate the proportion of volatile elemental loss from objects such as tektites, nuclear fallout melt glasses formed from silicate soils, and rocks from the Moon. The utility of the Zn isotope system in constraining the magnitude of volatile loss depends on accurate knowledge of its fractionation behavior during evaporation, i.e., the Zn isotope fractionation factor. In this work, we present new results of Zn isotope analyses of experimentally heated soil samples, together with analyses of environmentally derived fallout melt glasses, and australite tektites, to better constrain how and to what extent Zn isotopes fractionate during thermally-driven evaporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated aging test of new plastic scintillators

Fogging in plastic scintillators is a degradation mechanism that reduces light collection efficiency. In an effort to reduce maintenance costs, multiple groups have attempted to understand and prevent this problem by changing plastic compositions and system level designs. New formulations have been produced that are promising with respect to fogging resistance. In this paper, we study a variety of new compositions by subjecting them to an accelerated aging experiment with varying temperature and humidity profiles. Compositions are analyzed for their resistance to degradation after saturation periods, with those containing polymethyl methacrylate and divinyl benzene being the most promising. Pulse height spectra revealed that after environmental aging, many of the samples suffered a reduction in light yield to different degrees, a result that could be due to heating of the samples and may be prevented by further production optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Terrestrial Ecosystem Science With a Novel Automated Measurement System for Sun‐Induced Chlorophyll Fluorescence for Integration With Eddy Covariance Flux Networks

Abstract Sun‐induced chlorophyll fluorescence (SIF) provides critical information on the dynamics of gross primary productivity, a unique role not readily achievable using other methods. Long‐term continuous SIF observations have the potential to advance terrestrial ecosystem science. Realizing this potential, however, requires synergistic implementation of SIF measurements within eddy covariance (EC) flux networks. There is a need for SIF systems that can integrate seamlessly with EC instrumentation to maximize synergistic use of obtained data. Here we introduce the Fluorescence Auto‐Measurement Equipment (FAME) and protocol that fulfill such a purpose. FAME is designed specifically for plug‐and‐play integration with existing EC data acquisition systems. Its innovative hardware and software designs provide versatility, extensibility, autonomous operation, and ease of maintenance for acquiring SIF data of high quality and quantity. A major novel feature of FAME is its synchronized sampling of spectral irradiance and environmental variables, allowing for more precise interpretation of the SIF signal. FAME has been deployed since September 2016 at the Missouri Ozark AmeriFlux site, providing high‐quality measurements even when air temperatures approached 40 °C. Results reveal that canopy SIF saturated or even slightly decreased at high light, similar to leaf‐level photosynthesis. Clear diurnal hysteresis was observed: For the same light, morning SIF was higher than afternoon. Dynamic energy dissipation processes and stress‐induced movements of chloroplasts and leaves may explain the observed pattern. The technology and measurement protocol introduced here advances the coordinated observation of SIF and EC fluxes and represents a step change in observational ecosystem and carbon cycle science research.

54 ENVIRONMENTAL SCIENCES↗

Establishing a Proficiency Testing Scheme for Drinking Water Radiochemistry

As part of its international water proficiency testing (PT) scheme, 'Aquacheck', the LGC Proficiency Testing Group has established a new water radiochemistry PT scheme. The PT scheme is aimed at laboratories who undertake radiochemical analysis on drinking water samples as part of an environmental monitoring programme. Following a scheme design and feasibility study, the new scheme was established to monitor the laboratory performance of participants undertaking the determination of gross alpha, gross beta and tritium activity. Three rounds of the new water radiochemistry PT scheme are now complete. This paper explains the process of establishing such a scheme, reviews the results so far, and addresses future development of the scheme.

54 ENVIRONMENTAL SCIENCES↗

Higher Order Suppressor (HOS) for the PolLux Microspectroscope Beamline at the Swiss Light Source SLS

The mechanical design and performance of a device to suppress higher orders of a spherical grating monochromator at a constant deviation angle is described. The higher order suppressor (HOS) is used for a scanning transmission x-ray microspectroscope beamline (PolLux) at a bending magnet of the Swiss Light Source (SLS). The instruments allow microspectroscopy in polymer science, of biological samples in the water window as well as the study of magnetic materials with circular or linear polarized light in a photon energy range of 200 eV to 1400 eV. The HOS uses three mirrors acting as a low pass filter for soft x-rays to improve the absorption spectroscopy of carbon, oxygen and nitrogen 1s core levels. The successful installation and operation of the HOS located after the monochromator is reported. First results obtained using samples from materials research and environmental sciences exemplify the improved spectroscopy capabilities of the instrument.

43 PARTICLE ACCELERATORS↗

Influence of substrate miscut angle on surface morphology and luminescence properties of AlGaN

The influence of substrate miscut on Al{sub 0.5}Ga{sub 0.5} N layers was investigated using cathodoluminescence (CL) hyperspectral imaging and secondary electron imaging in an environmental scanning electron microscope. The samples were also characterized using atomic force microscopy and high resolution X-ray diffraction. It was found that small changes in substrate miscut have a strong influence on the morphology and luminescence properties of the AlGaN layers. Two different types are resolved. For low miscut angle, a crack-free morphology consisting of randomly sized domains is observed, between which there are notable shifts in the AlGaN near band edge emission energy. For high miscut angle, a morphology with step bunches and compositional inhomogeneities along the step bunches, evidenced by an additional CL peak along the step bunches, are observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using elliptical galaxy kinematics to compare the strength of gravity in cosmological regions of differing gravitational potential – a first look

ABSTRACT Various models of modified gravity invoke ‘screening’ mechanisms that are sensitive to the value of the local gravitational potential. This could have observable consequences for galaxies. These consequences might be seen by comparing two proxies for galaxy mass – their luminosity and their internal kinematics – as a function of local galaxy density. Motivated by this prospect, we have compared the observed properties of luminous red galaxies (LRGs) inside and outside of voids in the cosmic large scale structure. We used archival measurements of line widths, luminosities, redshifts, colours, and positions of galaxies in conjunction with recent void catalogues to construct comparison LRG samples inside and outside of voids. We fitted these two samples to the well-established fundamental plane of elliptical galaxies to constrain any differences between the inferred value of the Newtonian gravitational constant G for the two samples. We obtained a null result, with an upper limit on any fractional difference in G within and outside of cosmological voids to be α = δG/G ∼ 40 per cent. This upper bound is dominated by the small-number statistics of our N ∼ 100 within-void LRG sample. With the caveat that environmental effects could influence various parameters such as star formation, we estimate that a 1 per cent statistical limit on α could be attained with data from 105 elliptical galaxies within voids. This is within the reach of future photometric and spectroscopic surveys, both of which are required to pursue this method.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗