Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols

Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatric patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.

60 APPLIED LIFE SCIENCES↗

Synthesis, characterization, and in vitro anticancer evaluation of 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles

In this series, six new 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles were synthesized and characterized by IR, {sup 1}H NMR, {sup 13}C NMR spectroscopy, elemental analysis and chromato-mass-spectrometry. The anticancer activities of the compounds were evaluated via single high dose (10{sup −5}M) against 60 cancer cell lines by the National Cancer Institute according to its own screening protocol. In the next phase, the compounds have been selected for five-dose assay. All synthesized compounds displayed growth inhibitory (GI50) and cytostatic activities (TGI) against the most sensitive cell lines at submicromolar (0.2–0.6 μM) and micromolar concentrations (1–3 μM), respectively. Cytotoxic activity (LC{sub 50}) of these compounds, with the exception of 4d, against the most sensitive cell lines was also high (5–6 μM). All compounds exhibit high selectivity towards leukemia cell lines, and among them, 4e and 4f showed the best antiproliferative and cytostatic selectivity. Compounds 4c and 4f displayed considerable cytotoxic selectivity towards the renal and breast cancer subpanels. Our results provided evidence for anticancer activities of novel 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles which could be useful for developing new anticancer drugs. These substances could also be used as an excellent framework in anticancer research that may lead to discovery of potent antitumor agents.

60 APPLIED LIFE SCIENCES↗

Aggregate attack surface management for network discovery of operational technology

Interconnectivity has become a substratum of technology as the benefits of data-driven functionality are being realized in nearly all industries. Increased connectivity of Operational Technology (OT) exacerbates cyber risks because Industrial Control Systems (ICS) are becoming exposed to the Internet. These exposures are often done inadvertently through misconfigurations as additional network devices come online. Attack surface management (ASM) platforms can be used to identify vulnerabilities by performing external network discovery over the Internet using web spiders. These web spiders enable big data analytics of Internet of Things (IoT) devices as identifiable information of Internet-exposed equipment are archived in searchable databases that are made publicly available. There are a multitude of ASM service providers on the market. Here, this study was conducted to evaluate several commonly known tools to determine the aggregate attack surface of control systems. Queries were crafted by targeting commonly known manufacturers and communication protocols found in OT networks. Identified devices were that categorized based on technology types. Each query was replicated between several tools to target identical ICS equipment. Findings in this paper suggested a significant variance in the exposures discovered by each tool, but unique contributions were identified for each tool when a merged attack surface was derived. Therefore, all tools should be used in aggregate.

97 MATHEMATICS AND COMPUTING↗

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive Circuit Learning for Quantum Metrology

Quantum sensing is an important application of emerging quantum technologies. We explore whether a hybrid system of quantum sensors and quantum circuits can surpass the classical limit of sensing. In particular, we use optimization techniques to search for encoder and decoder circuits that scalably improve sensitivity under given application and noise characteristics. Furthermore, our approach uses a variational algorithm that can learn a quantum sensing circuit based on platform-specific control capacity, noise, and signal distribution. The quantum circuit is composed of an encoder which prepares the optimal sensing state and a decoder which gives an output distribution containing information of the signal. We optimize the full circuit to maximize the Signal-to-Noise Ratio (SNR). Furthermore, this learning algorithm can be run on real hardware scalably by using the "parameter-shift" rule which enables gradient evaluation on noisy quantum circuits, avoiding the exponential cost of quantum system simulation. We demonstrate up to 13.12x SNR improvement over existing fixed protocol (GHZ), and 3.19x Classical Fisher Information (CFI) improvement over the classical limit on 15 qubits using IBM quantum computer. More notably, our algorithm overcomes the decreasing performance of existing entanglement-based protocols with increased system sizes.

42 ENGINEERING↗

A Benthic Habitat Monitoring Approach for Marine and Hydrokinetic Sites (Final Technical Report)

This final technical report summarizes the work completed as part of the Standardized and Cost-Effective Benthic Habitat Mapping and Monitoring Tools for MHK Environmental Assessments project funded by U.S. Department of Energy (DOE) under contract DE-EE007826 to Integral Consulting Inc. The overall goal of this project was to demonstrate a consistent, repeatable, and semi-automated seafloor and sediment mapping approach for rapidly characterizing benthic physical and biological/habitat conditions to support marine environmental assessments for marine and hydrokinetic energy sites. The approach evaluated combines sediment profile imaging and plan view (SPI/PV) technology with multibeam echosounder surveys as an effective and low-cost benthic habitat mapping protocol. A key innovation was the development of a semi-automated computer vision system that standardizes the extraction of data from the SPI/PV images. Other elements of the project were SPI camera hardware modifications, including the design and fabrication of a prototype “power” SPI camera to improve camera prism penetration in firm substrates, and outreach to agency regulators and other stakeholders on this habitat mapping approach. This technical report consists of five main subsections that summarize: 1) the benthic mapping approach; 2) benthic mapping results from the three areas’ surveys; 3) the development and performance of the image processing algorithms; 4) SPI camera hardware improvements and prototype testing; and 5) the regulatory outreach efforts.

16 TIDAL AND WAVE POWER↗

The REPACT Tool: User Manual [Slides]

Reuse of Existing Pipelines for Adapted Carbon Transport (REPACT) is an Excel-based screening tool. This tool enables the user to determine whether a pipeline originally deployed for natural gas transport, can be reused for CO 2 transport. The tool along with its associated users manual walk through an intended usage statement, setup instructions, a list of inputs and outputs in the tool, and frequently used protocols. Please note that this is a first-pass screening tool. The approach presented within this tool is valid for high-level evaluation only and should not be used to make engineering, financial, and/or regulatory decisions. Access the tool here: https://www.netl.doe.gov/energy-analysis/details?id=c699a604-ded1-45cd-b1c0-247b1405aeeb

03 NATURAL GAS↗

Responses to graded lower body negative pressure after space flight

Lower body negative pressure tests (0 to -60 mm Hg) were administered 2-3 times preflight and 4 times postflight (L0 to L7), to evaluate the effect of space flight on orthostatic responses. This paper presents preliminary findings from the first 4 crew members who have completed this protocol. Overall the results suggest a greater orthostatic strain lasting approximately two days postflight, that may have been due to enhanced pooling of blood in body regions other than the calf.

Fortney, Suzanne M.↗

Carbon-Temperature-Water Change Analysis for Peanut Production Under Climate Change: A Prototype for the AgMIP Coordinated Climate-Crop Modeling Project (C3MP)

Climate change is projected to push the limits of cropping systems and has the potential to disrupt the agricultural sector from local to global scales. This article introduces the Coordinated Climate-Crop Modeling Project (C3MP), an initiative of the Agricultural Model Intercomparison and Improvement Project (AgMIP) to engage a global network of crop modelers to explore the impacts of climate change via an investigation of crop responses to changes in carbon dioxide concentration ([CO2]), temperature, and water. As a demonstration of the C3MP protocols and enabled analyses, we apply the Decision Support System for Agrotechnology Transfer (DSSAT) CROPGRO-Peanut crop model for Henry County, Alabama, to evaluate responses to the range of plausible [CO2], temperature changes, and precipitation changes projected by climate models out to the end of the 21st century. These sensitivity tests are used to derive crop model emulators that estimate changes in mean yield and the coefficient of variation for seasonal yields across a broad range of climate conditions, reproducing mean yields from sensitivity test simulations with deviations of ca. 2% for rain-fed conditions. We apply these statistical emulators to investigate how peanuts respond to projections from various global climate models, time periods, and emissions scenarios, finding a robust projection of modest (<10%) median yield losses in the middle of the 21st century accelerating to more severe (>20%) losses and larger uncertainty at the end of the century under the more severe representative concentration pathway (RCP8.5). This projection is not substantially altered by the selection of the AgMERRA global gridded climate dataset rather than the local historical observations, differences between the Third and Fifth Coupled Model Intercomparison Project (CMIP3 and CMIP5), or the use of the delta method of climate impacts analysis rather than the C3MP impacts response surface and emulator approach.

climate change↗

Increasing Cognitive Ability/Reserve Using Software – Pilot (ICARUS-Pilot)

BACKGROUND This research study was competitively awarded under the 2022 JSC Innovation Charge Account (ICA) program administered by NASA Johnson Space Center’s Joint Technology Working Group. Study period of performance was May through September 2022, with a maximum allowed procurement budget of $10K. The study sought to quantify and assess the potential benefit of using commercial-off-the-shelf (COTS) cognitive training software to improve cognitive performance in an astronaut-like terrestrial population. METHODS Five volunteer research participants were recruited from the JSC employee population to mimic certain demographic characteristics of the NASA astronaut population (age, education/discipline). Participant cognitive performance was assessed before and after executing eighteen sessions of remote cognitive training executed nominally three times per week using six exercises within an adaptive app-based COTS software package (BrainHQ, Posit Science) on study-provided tablets. Pre- and post-training cognitive performance was measured using internal assessments in BrainHQ as well as Cognition Test Battery (CTB) version ISS B01 v3 (3.0.9-201710021500), an independent software test developed specifically for NASA and used currently in research studies on astronauts. BrainHQ exercises were posited to map well or partially to several CTB sub-tests. Participants provided feedback on their study experience formally via semi-structured interview at the conclusion of testing and informally throughout the study if they encountered issues. RESULTS The enrolled ICARUS-Pilot study participants generally matched Artemis crew demographic characteristics. Four of five participants have completed study training and assessment activities as of the writing of this abstract. These test participants complied well with desired training session frequency and duration yielding an average cumulative active training duration of 15 hours over an average of 45 days; participants showed 78% average improvement in metric performance for the six trained exercises, with an associated overall 33%ile ranking increase against performance of the entire BrainHQ subscribing population for internal pre/post assessment, agreeing with post-study survey self-reported performance increases. CTB overall feedback scoring, not corrected for learning effects, showed an average of 19% performance improvement across its 10 performance measures over the training period for the completed participants. Detailed analyses will be conducted once participant data collection for the study is complete and the resulting dataset is fully populated. DISCUSSION These preliminary results provide a positive trend for the effectiveness of the training approach, but further analysis will be needed to establish significance, investigate far transfer, and suggest the needed participant pool size for subsequent efforts to achieve statistically significant outcomes given similar results. The pilot study has already been helpful by allowing the study team to learn a great deal about the capabilities and limitations of the COTS software package that will be reflected in future proposals along with revised timelines for study execution and test participant management. From participant feedback, one common thread regarding the COTS training was that it felt overly repetitive – future proposals should reassess overall training duration, available levels for each trained exercise, and the behavior of the BrainHQ internal scheduler in determining which exercises should be trained and for how long. If the final analysis of this feasibility study ultimately supports it, the study team will recommend further investigation to fully evaluate this potential countermeasure and optimize its implementation. Future proposals would cite this feasibility study’s outcome and would seek to refine the training protocol and obtain statistically significant results for cognitive performance increases as well as retention data.

cognitive training↗

Increasing Cognitive Ability/Reserve Using Software – Pilot (ICARUS-Pilot)

Background: This research study was competitively awarded under the 2022 JSC Innovation Charge Account (ICA) program administered by NASA Johnson Space Center’s Joint Technology Working Group. Study period of performance was May through September 2022, with a maximum allowed procurement budget of $10K. The study sought to quantify and assess the potential benefit of using commercial-off-the-shelf (COTS) cognitive training software to improve cognitive performance in an astronaut-like terrestrial population. Methods: Five volunteer research participants were recruited from the JSC employee population to mimic certain demographic characteristics of the NASA astronaut population (age, education/discipline). Participant cognitive performance was assessed before and after executing eighteen sessions of remote cognitive training executed nominally three times per week using six exercises within an adaptive app-based COTS software package (BrainHQ, Posit Science) on study-provided tablets. Pre- and post-training cognitive performance was measured using internal assessments in BrainHQ as well as Cognition Test Battery (CTB) version ISS B01 v3 (3.0.9-201710021500), an independent software test developed specifically for NASA and used currently in research studies on astronauts. BrainHQ exercises were posited to map well or partially to several CTB sub-tests. Participants provided feedback on their study experience formally via semi-structured interview at the conclusion of testing and informally throughout the study if they encountered issues. Results: The enrolled ICARUS-Pilot study participants generally matched Artemis crew demographic characteristics. Four of five participants have completed study training and assessment activities as of the writing of this abstract. These test participants complied well with desired training session frequency and duration yielding an average cumulative active training duration of 15 hours over an average of 45 days; participants showed 78% average improvement in metric performance for the six trained exercises, with an associated overall 33%ile ranking increase against performance of the entire BrainHQ subscribing population for internal pre/post assessment, agreeing with post-study survey self-reported performance increases. CTB overall feedback scoring, not corrected for learning effects, showed an average of 19% performance improvement across its 10 performance measures over the training period for the completed participants. Detailed analyses will be conducted once participant data collection for the study is complete and the resulting dataset is fully populated. Discussion: These preliminary results provide a positive trend for the effectiveness of the training approach, but further analysis will be needed to establish significance, investigate far transfer, and suggest the needed participant pool size for subsequent efforts to achieve statistically significant outcomes given similar results. The pilot study has already been helpful by allowing the study team to learn a great deal about the capabilities and limitations of the COTS software package that will be reflected in future proposals along with revised timelines for study execution and test participant management. From participant feedback, one common thread regarding the COTS training was that it felt overly repetitive – future proposals should reassess overall training duration, available levels for each trained exercise, and the behavior of the BrainHQ internal scheduler in determining which exercises should be trained and for how long. If the final analysis of this feasibility study ultimately supports it, the study team will recommend further investigation to fully evaluate this potential countermeasure and optimize its implementation. Future proposals would cite this feasibility study’s outcome and would seek to refine the training protocol and obtain statistically significant results for cognitive performance increases as well as retention data.

cognitive training↗

ETF Grout Expansion: Effects of Different Slags and Struvite Precipitation Protocols (Stirring Time)

The ETF ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during solidification of an ammonium-rich, concentrated sodium sulfate aqueous waste stream generated at the Hanford Effluent Treatment Facility (ETF). VSL personnel did not observe expansion in samples prepared during the waste form development work. However, Savannah River National Laboratory (SRNL) personnel detected expansion, in a few ETF grout samples, up to ~ 20 percent vertical expansion, while preforming work scope to evaluate the effect of ETF brine compositional ranges on the precipitation and solidification processes. The initial work requests can be found in Washington River Protection Services (WRPS) Statement of Work (SOW, Requisitions #: 339922 Revisions 0 and 1, March 11, 2021, and November 2021, respectively. As a result of the waste form expansion observed by SRNL, additional evaluation was requested by WRPS SOW Requisitions #: 356730 Revision 0 and Revision 1, February 1, 2022, and July 11, 2022, respectively. The goal of these requests was to determine whether differences in the slags and / or in sample preparation protocols used by VSL and SRNL were the cause of the expansion observed in the SRNL samples. G. Chen, WRPS, arranged a materials exchange between VSL and SRNL and coordinated the VSL protocol(s) for grouting and curing 1L batches of Base Case ETF base case simulant. Materials were exchanged between VSL and SRNL. Both laboratories performed the VSL struvite precipitation-solidification protocol and cured samples for at least 28 days. Differences in VSL and SRNL slag compositions, mineralogy and particle size results in themselves or combined were determined to not be the cause of the expansion because all samples expanded regardless of whether the VSL or SRNL slags were used. The fundamental cause of the observed expansion could not be attributed to minor variations in the following: 1) chemistry of the slag and other reagents, 2) container wall thickness, 3) ambient bench top curing conditions at VSL and SRNL, 4) pH adjustments to 7 ± a few tenths of unit, nor 5) stirring time between the precipitation and solidification process steps. Additional observations include: grout samples prepared with VSL slag expanded less than those prepared with the SRNL slag and, based on a very limited sample set, some samples stirred for longer times expanded less than those stirred for 20 minutes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Concurrent Cardiovascular Information to Augment Survival Time Data for Evaluating Orthostatic Tilt Test Performance

Head-up tilt (HUT) tests often are used in research to measure orthostatic intolerance (OI) (inability to appropriately control blood pressure while upright) in clinical populations and otherwise healthy individuals after interventions. Post-space flight orthostatic intolerance is a well-known phenomenon, and countermeasures to its development has been an active area of research at NASA. In the NASA HUT protocol, subjects lie horizontally on an automatic tilt table for baseline measurements before being raised to 80deg head-up tilt for a defined period of time or until signs or symptoms of presyncope ensues (light-headedness, nausea, dizziness, sweating, weakness or fainting). Multiple measures are collected to evaluate the cardiovascular system's ability to respond appropriately to the orthostatic challenge. However if the intended duration of the HUT is short, the ability to detect changes in OI due to an intervention or its prevention by a countermeasure may be limited by a small number of failures to permit comparisons based on survival time alone. Thus, the time-trajectory of the cardiovascular data becomes an important additional source of information. In particular, we will show how various measures of trajectory variability can effectively augment survival analysis for the assessment of OI in a joint model when high censoring rates are present.

Feiveson, Alan H.↗

Implementation Plan for Qualification of Sodium-Cooled Fast Reactor Technology Information

This document identifies and discusses implementation elements that can be used to facilitate consistent and systematic evaluation processes relating to quality attributes of technical information (with focus on SFR technology) that will be used to support licensing of advanced reactor designs. Information may include, but is not limited to, design documents for SFRs, research-and-development (R&D) data and associated documents, test plans and associated protocols, operations and test data, international research data, technical reports, and information associated with past U.S. Nuclear Regulatory Commission (NRC) reviews of SFR designs. The approach for determining acceptability of test data, analysis, and/or other technical information is based on guidance provided in INL/EXT-15-35805, “Guidance on Evaluating Historic Technology Information for Use in Advanced Reactor Licensing.” The implementation plan can be adopted into a working procedure at each of the national laboratories performing data qualification, or by applicants seeking future license application for advanced reactor technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emissions Merit Function for Evaluating Multifunctional Catalyst Beds

With emission control regulations getting stricter, multi-functional catalyst systems are increasingly important for low-temperature operation. We investigate a wide range of multi-component catalyst systems, as physical mixtures and in multi-bed configurations, while varying the ratios of hydrocarbon traps (HCT), passive NOx adsorbers (PNAs), and diesel oxidation catalysts (DOC). Using industrially guided protocols, we measured the ability of these complex catalyst systems to reduce emissions during a 40 °C/min temperature ramp to simulate cold-start conditions. Using a temperature boundary condition of 250 °C, the average conversion was calculated for each regulated pollutant: CO, NOx, and total hydrocarbons (THC). An emissions merit function was developed to evaluate the effectiveness of each system relative to the relevant emission standards and expected engine exhaust concentrations. This merit function identified that a 1:1:4 ratio of PNA:HCT:DOC was the most effective emissions reduction configuration and had similar reactivity as a physical mixture or as a PNA→HCT→DOC multi-bed reactor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods to Calculate Electronic Excited-State Dynamics for Molecules on Large Metal Clusters with Many States: Ensuring Fast Overlap Calculations and a Robust Choice of Phase

Here, we present an efficient set of methods for propagating excited-state dynamics involving a large number of configuration interaction singles (CIS) or Tamm-Dancoff approximation (TDA) single-reference excited states. Specifically, (i) following Head-Gordon et al., we implement an exact evaluation of the overlap of singly-excited CIS/TDA electronic states at different nuclear geometries using a biorthogonal basis and (ii) we employ a unified protocol for choosing the correct phase for each adiabat at each geometry. For many-electron systems, the combination of these techniques significantly reduces the computational cost of integrating the electronic Schrodinger equation and imposes minimal overhead on top of the underlying electronic structure calculation. As a demonstration, we calculate the electronic excited-state dynamics for a hydrogen molecule scattering off a silver metal cluster, focusing on high-lying excited states, where many electrons can be excited collectively and crossings are plentiful. Interestingly, we find that the high-lying, plasmon-like collective excitation spectrum changes with nuclear dynamics, highlighting the need to simulate non-adiabatic nuclear dynamics and plasmonic excitations simultaneously. In the future, the combination of methods presented here should help theorists build a mechanistic understanding of plasmon-assisted charge transfer and excitation energy relaxation processes near a nanoparticle or metal surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-486: In Vivo Skin Dosimetry Using the Exradin W1 Plastic Scintillation Detector for Passively Scattered Proton Beam Therapy

Purpose: To evaluate the accuracy and usefulness of plastic scintillation detectors used for skin dosimetry of patients undergoing passive scatter proton therapy. Methods: Following an IRB approved protocol, six patients undergoing passively scattered proton beam therapy for prostate cancer were selected for in vivo skin dosimetry using the Exradin W1 plastic scintillator. The detector was calibrated on a Cobalt-60 unit, and phantom measurements in the proton beam with the W1 and a calibrated parallel plate ion chamber were used to account for the under-response due to high LET at energies used for treatment. Measurements made in a heated water tank were used to account for temperature dependence. For in vivo measurements, the W1 is fixed to the patient’s skin with medical tape in the center of each of two laterally opposed treatment fields. Measurements will be performed once per week for each patient for the duration of treatment, for a total of thirty six measurements. The measured dose will be compared to the expected dose, extracted from the Eclipse treatment planning system. The average difference over all measurements and per-patient will be computed, as well as standard deviations. Results: The calibrated detector exhibited a 7% under-response in 225 and 250 MeV beams, and a 4% under-response when used at 37 °C (relative to the response at the calibration temperature of 20 °C). Patient measurements are ongoing. Conclusion: The Exradin W1 plastic scintillator detector is a strong candidate for in vivo skin dosimetry in passively scattered proton beams as PSDs are water equivalent and very small (2mm in diameter), permitting accurate measurements that do not perturb the delivered dose. This project was supported in part by award number CA182450 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗