Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

High-precision measurements of the compressibility of chalcogenide glasses at a hydrostatic pressure up to 9 GPa

The volumes of glassy germanium chalcogenides GeSe{sub 2}, GeS{sub 2}, Ge{sub 17}Se{sub 83}, and Ge{sub 8}Se{sub 92} are precisely measured at a hydrostatic pressure up to 8.5 GPa. The stoichiometric GeSe{sub 2} and GeS{sub 2} glasses exhibit elastic behavior in the pressure range up to 3 GPa, and their bulk modulus decreases at pressures higher than 2–2.5 GPa. At higher pressures, inelastic relaxation processes begin and their intensity is proportional to the logarithm of time. The relaxation rate for the GeSe{sub 2} glasses has a pronounced maximum at 3.5–4.5 GPa, which indicates the existence of several parallel structural transformation mechanisms. The nonstoichiometric glasses exhibit a diffuse transformation and inelastic behavior at pressures above 1–2 GPa. The maximum relaxation rate in these glasses is significantly lower than that in the stoichiometric GeSe{sub 2} glasses. All glasses are characterized by the “loss of memory” of history: after relaxation at a fixed pressure, the further increase in the pressure returns the volume to the compression curve obtained without a stop for relaxation. After pressure release, the residual densification in the stoichiometric glasses is about 7% and that in the Ge{sub 17}Se{sub 83} glasses is 1.5%. The volume of the Ge{sub 8}Se{sub 92} glass returns to its initial value within the limits of experimental error. As the pressure decreases, the effective bulk moduli of the Ge{sub 17}Se{sub 83} and Ge{sub 8}Se{sub 92} glasses coincide with the moduli after isobaric relaxation at the stage of increasing pressure, and the bulk modulus of the stoichiometric GeSe{sub 2} glass upon decreasing pressure noticeably exceeds the bulk modulus after isobaric relaxation at the stage of increasing pressure. Along with the reported data, our results can be used to draw conclusions regarding the diffuse transformations in glassy germanium chalcogenides during compression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm-Based Fault Tolerance for Convolutional Neural Networks

Convolutional neural networks (CNNs) are becoming more and more important for solving challenging and critical problems in many fields. CNN inference applications have been deployed in safety-critical systems, which may suffer from soft errors caused by high-energy particles, high temperature, or abnormal voltage. Of critical importance is ensuring the stability of the CNN inference process against soft errors. Traditional fault tolerance methods are not suitable for CNN inference because error-correcting code is unable to protect computational components, instruction duplication techniques incur high overhead, and existing algorithm-based fault tolerance (ABFT) techniques cannot protect all convolution implementations. In this paper, we focus on how to protect the CNN inference process against soft errors as efficiently as possible, with the following three contributions. (1) We propose several systematic ABFT schemes based on checksum techniques and analyze their fault protection ability and runtime thoroughly. Unlike traditional ABFT based on matrix-matrix multiplication, our schemes support any convolution implementations. (2) We design a novel workflow integrating all the proposed schemes to obtain a high detection/correction ability with limited total runtime overhead. (3) We perform our evaluation using ImageNet with well-known CNN models including AlexNet, VGG-19, ResNet-18, and YOLOv2. Here, experimental results demonstrate that our implementation can handle soft errors with very limited runtime overhead (4%~8% in both error-free and error-injected situations).

97 MATHEMATICS AND COMPUTING↗

Uncertainty quantification of a physics-informed model based on sparse identification of a Thermal Energy Distribution System

Integrated energy systems (IES)s are crucial for enhancing the economy and efficiency of power generation sources (e.g., nuclear energy) necessary to unleash American energy dominance. These systems can be integrated with thermal energy storage (TES) and intermittent renewable energies to optimize overall energy use, peak-load regulation, and demand-side responses. However, the stabilization of energy generation, transport, and utilization introduces operational complexities that exceed the challenges of managing each sub-component individually. Currently, though IESs rely on human operators for efficiency and stability, reducing human error risk and enhancing performance through automation is highly desirable. Recent advances at Idaho National Laboratory have demonstrated successful control of the Thermal Energy Distributed System (TEDS). However, the automatic control system depends on a deterministic Sparse Identification of Nonlinear Dynamics with Control (SINDyC) model, which are trained based on simulation data from physics-based simulations. Because of uncertainties in physics-based simulation, SINDyC model results in large discrepancies against experimental data and cannot be reliably used in automatic control. In this paper, we present an innovative approach to address these discrepancies by quantifying uncertainties and developing a more robust model. We first generated trajectories by using first-principles physics codes to encapsulate the experiment. Next, we trained thousands of models by randomly sampling these trajectories. We then collapsed all those models into one probabilistic SINDyC by fitting a multivariate Gaussian distribution onto the resulting coefficient’s distribution. Despite its simplicity, our approach successfully produced 95% confidence intervals that captured the experimental trajectories. It even did so with a higher probability and better U-pooling score across six of the seven relevant quantities of interest (QoIs), as compared to other classical approaches. In conclusion, ongoing research is focusing on generating new experimental trajectories to validate this approach, and on employing Bayesian calibration to refine parametric uncertainties and guide future model development efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

Data Evaluation of Actinide Cross Sections: 240 Am, 241 Am, and 242 Am

Evaluations for neutron-induced reactions on the isotopes 240 Am, 241 Am, and 242 Am were per formed by optimizing reaction-model calculations based on existing experimental data from both direct measurements and surrogate reactions. The evaluated data were based on results obtained from the LLNL reaction codes YAHFC and FRESCO using up-to-date nuclear models; including an improvement upon some previous treatments for inelastic processes. Nuclear reaction codes generated data for all relevant reaction channels, which were then translated into Generalized Nu clear Data Structure and LLNL’s Evaluated Neutron Data Libraries (ENDL). These data libraries were tested for potential errors and applied to verification and validation (V&V) tests suites where applicable for comparisons.

42 ENGINEERING↗

Characterizing particle-scale equilibrium adsorption and kinetics of uranium(VI) desorption from U-contaminated sediments

Rates of contaminant U(VI) release from individual size fractions of a composite sediment from the seasonally saturated lower vadose zone of the Hanford 300-Area were examined in flow-through batch reactors to maintain quasi-constant chemical conditions. Variability in equilibrium adsorption among the various size fractions was determined in static batch reactors and analyzed using the surface complexation modeling approach. The estimated stoichiometric coefficients of U(VI) surface complexation reactions with respect to pH and carbonate concentrations varied with size fractions. This source of variability significantly increased the uncertainty in U(VI) conditional equilibrium constants over that estimated from experimental errors alone. A minimum difference between conditional equilibrium constants was established in order to evaluate statistically significant differences between sediment adsorption properties. A set of equilibrium and kinetic expressions for cation exchange, calcite dissolution, aerobic respiration, and silica dissolution were incorporated in a reaction-rate model to describe the temporal evolution of solute concentrations observed during the flow-through batch experiments. Parameters in the reaction-rate model, calibrated using experimental data for select size fractions, predicted the changes in solute concentrations for the bulk, <2 mm, sediment sample. Kinetic U(VI) desorption was well described using a multi-rate surface complexation model with an assumed lognormal distribution for the rate constants. The estimated mean and standard deviation were the same for all < 2mm size fractions, but differed in the 2-8mm size fraction. Micropore volumes in the varied size fractions were also similar as assessed using t-plots to analyze N2 desorption data. These findings provide further support for the link between microporosity and particle-scale mass transfer rates controlling kinetic U(VI) adsorption/desorption and for the utility of N2 desorption isotherms for characterizing pore networks that influence mass transfer rates.

Stoliker, Deborah L.↗

A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-Invasive Electrode Impedance Estimation for Optimized Charge Profile Parameterization of Lithium-Ion Batteries

This work presents a non-invasive method for parameterizing a physically motivated equivalent circuit model of lithium-ion batteries using operando electrochemical impedance spectroscopy and time-domain data. The proposed model consists exclusively of linear circuit elements, enabling computationally efficient simulation and real-time implementation on battery management system chips. By integrating frequency- and time-domain measurements, the model accurately estimates internal states such as the negative electrode potential, achieving a root mean square error of 12.3 mV during fast charging validation. Parameterization requires only rate tests with sinusoidal perturbations at three different ambient temperatures, making the approach experimentally accessible. The model reveals key insights into battery behavior, including rate-dependent overpotentials primarily governed by charge transfer kinetics at the positive electrode, and temperature-dependent impedance contributions from both charge transfer and solid-state diffusion processes. Validation using reference electrodes confirms the model’s ability to detect lithium plating onset and reproduce impedance behavior across a wide range of operating conditions. The approach enables in situ optimization of fast charging profiles and lays the foundation for future extensions incorporating aging effects and plating dynamics.

25 ENERGY STORAGE↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data: The first iteration

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Bayesian calibration of irradiated graphite property models under high temperatures

Graphite under high temperatures and irradiation is central to advanced reactors. We develop a Bayesian calibration framework for graphite property models that explicitly represents model-data mismatch via a Gaussian-process discrepancy. The approach propagates uncertainty from parameters, experimental noise, and model form, with a hierarchical variance structure to capture group and cross-group noise. Using two predictive models across five grades (IG-110, NBG-18, PCEA, NBG-17, 2114) and four properties-irradiation-induced dimension change, creep, Young’s modulus change ratio, and coefficient of thermal expansion change ratio-we obtain average predictive-error reductions of 54%, 65%, 17%, and 17% when discrepancy is included. We illustrate engineering impact with a multiphysics model of a very-high-temperature reactor prismatic reflector brick, analyzing stresses under high fluence and temperature. Accounting for model discrepancy markedly improves predictive accuracy and provides a robust basis for reliable graphite component design in advanced reactors.

36 - MATERIALS SCIENCE↗

A new emissive-probe method for electron temperature measurement in radio-frequency plasmas

A new method to measure electron temperature by an emissive probe has been proposed. The method is based on measurement of the functional relationship between the floating potential and the heating voltage of emissive probe. From the measured data of the floating potential change as a function of the heating voltage, the electron temperature could be determined by comparing with the theoretical curve obtained under the assumption of Maxwellian distribution. The overall characteristic of the floating potential change could be explained as a function of the heating voltage. The electron temperatures obtained by the present method were consistent with those measured by the rf-compensated Langmuir probe within the error. These experimental verifications were made in the electron density range of 2.6x10{sup 11}-2.8x10{sup 12} cm{sup -3}. It was stressed that the present method is advantageous in that the probe is operated in a floating condition, hence applicable to plasmas produced in an insulated container.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Muon Lifetime Measurement and Introduction to the use of FPGAs in Experimental Physics

During the laboratory sessions at the Workshop, the students used a simple experimental setup to measure the muon lifetime with a 10% statistical error. The muon detector consisted of a sealed container, filled with liquid scintillator, coupled to a 2.5'' photomultiplier (PMT). A personal computer (PC) was used to control a digital oscilloscope which directly measured the time interval between two consecutive PMT pulses in a time window of 20 {mu}s. The students were also introduced to the use of root to analyze the muon data and to measure the muon lifetime. They were also presented with a basic introduction to the application of field-programmable gate arrays (FPGAs) in data acquisition (DAQ) systems by means of examples. We started with a brief introduction to the VHDL language and the software package used to program FPGAs and PROMs on a commercial FPGA development board. They learned to program FPGAs for handling data transfers using the RS-232 port of a PC. They were also introduced to the concepts of circular RAMs (Random Access Memory) and FIFO (First-In First-Out) memories in the context of fast and efficient DAQ systems. We emphasized the way in which inexpensive FPGA-based electronics replaces the use of traditionally used electronics modules, such as NIM, CAMAC, FASTBUS, VME, etc., to construct fast and powerful DAQ systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of Cutting Forces Using ANNs Approach in Hard Turning of AISI 52100 steel

In this study, artificial neural networks (ANNs) was used to predict cutting forces in the case of machining the hard turning of AISI 52100 bearing steel using cBN cutting tool. Cutting forces evolution is considered as the key factors which affect machining. Predicting cutting forces evolution allows optimizing machining by an adaptation of cutting conditions. In this context, it seems interesting to study the contribution that could have artificial neural networks (ANNs) on the machining forces prediction in both numerical and experiment studies. Feed-forward multi-layer neural networks trained by the error back-propagation (BP) algorithm are used. Levenberg-Marquardt (LM) optimization algorithm was used for finding out weights. The training of the network is carried out with experimental machining data.The input dataset used are cutting speed, feed rate, cutting depth and hardness of the material. The output dataset used are cutting forces (Ft-cutting force, Fa- feed force and Fr- radial force).Results of the neural networks approach, in comparison with experimental data are discussed in last part of this paper.

36 MATERIALS SCIENCE↗