Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Modified thermal-optical analysis using spectral absorption selectivity to distinguish black carbon from pyrolized organic carbon

Black carbon (BC), a main component of combustion-generated soot, is a strong absorber of sunlight and contributes to climate change. Measurement methods for BC are uncertain, however. This study presents a method for analyzing the BC mass loading on a quartz fiber filter using a modified thermal-optical analysis method, wherein light transmitted through the sample is measured over a spectral region instead of at a single wavelength as the sample is heated. Evolution of the spectral light transmission signal depends on the relative amounts of light-absorbing BC and char, the latter of which forms when organic carbon in the sample pyrolyzes during heating. Absorption selectivities of BC and char are found to be distinct and are used to apportion the amount of light attenuated by each component in the sample. Light attenuation is converted to mass concentration based on derived mass attenuation efficiencies (MAE) of BC and char. The fraction of attenuation due to each component are scaled by their individual MAE values and added together as the total mass of light absorbing carbon (LAC). An iterative algorithm is used to find the MAE values for both BC and char that provide the best fit to the carbon mass remaining on the filter (derived from direct measurements of thermally evolved CO{sub 2}) at temperatures higher than 480 C. This method was applied to measure the BC concentration in precipitation samples collected from coastal and mountain sites in Northern California. The uncertainty in measured BC concentration of samples that contained a high concentration of organics susceptible to char ranged from 12 to 100 percent, depending on the mass loading of BC on the filter. The lower detection limit for this method was approximately 0.35 {micro}g BC and uncertainty approached 20 percent for BC mass loading greater than 1.0 {micro}g BC.

54 ENVIRONMENTAL SCIENCES↗

Improved methods of performing coherent optical correlation

Coherent optical correlators are described in which complex spatial filters are recorded by a quasi-Fourier transform method. The high-pass spatial filtering effects (due to the dynamic range of photographic films) normally encountered in Vander Lugt type complex filters are not present in this system. Experimental results for both transmittive as well as reflective objects are presented. Experiments are also performed by illuminating the object with diffused light. A correlator using paraboloidal mirror segments as the Fourier-transforming element is also described.

Husain-Abidi, A. S.↗

Estimation of the weighted CTDI{sub {infinity}} for multislice CT examinations

Purpose: The aim of this study was to examine the variations of CT dose index (CTDI) efficiencies, {epsilon}(CTDI{sub 100})=CTDI{sub 100}/CTDI{sub {infinity}}, with bowtie filters and CT scanner types. Methods: This was an extension of our previous study [Li, Zhang, and Liu, Phys. Med. Biol. 56, 5789-5803 (2011)]. A validated Monte Carlo program was used to calculate {epsilon}(CTDI{sub 100}) on a Siemens Somatom Definition scanner. The {epsilon}(CTDI{sub 100}) dependencies on tube voltages and beam widths were tested in previous studies. The influences of different bowtie filters and CT scanner types were examined in this work. The authors tested the variations of {epsilon}(CTDI{sub 100}) with bowtie filters on the Siemens Definition scanner. The authors also analyzed the published CTDI measurements of four independent studies on five scanners of four models from three manufacturers. Results: On the Siemens Definition scanner, the difference in {epsilon}(CTDI{sub W}) between using the head and body bowtie filters was 2.5% (maximum) in the CT scans of the 32-cm phantom, and 1.7% (maximum) in the CT scans of the 16-cm phantom. Compared with CTDI{sub W}, the weighted CTDI{sub {infinity}} increased by 30.5% (on average) in the 32-cm phantom, and by 20.0% (on average) in the 16-cm phantom. These results were approximately the same for 80-140 kV and 1-40 mm beam widths (4.2% maximum deviation). The differences in {epsilon}(CTDI{sub 100}) between the simulations and the direct measurements of four previous studies were 1.3%-5.0% at the center/periphery of the 16-cm/32-cm phantom (on average). Conclusions: Compared with CTDI{sub vol}, the equilibrium dose for large scan lengths is 30.5% higher in the 32-cm phantom, and is 20.0% higher in the 16-cm phantom. The relative increases are practically independent of tube voltages (80-140 kV), beam widths (up to 4 cm), and the CT scanners covered in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Topology optimization of finite strain viscoplastic systems under transient loads [Dynamic topology optimization based on finite strain visco-plasticity]

In this paper, a transient finite strain viscoplastic model is implemented in a gradient-based topology optimization framework to design impact mitigating structures. The model's kinematics relies on the multiplicative split of the deformation gradient, and the constitutive response is based on isotropic hardening viscoplasticity. To solve the mechanical balance laws, the implicit Newmark-beta method is used together with a total Lagrangian finite element formulation. The optimization problem is regularized using a partial differential equation filter and solved using the method of moving asymptotes. Sensitivities required to solve the optimization problem are derived using the adjoint method. To demonstrate the capability of the algorithm, several protective systems are designed, in which the absorbed viscoplastic energy is maximized. Finally, the numerical examples demonstrate that transient finite strain viscoplastic effects can successfully be combined with topology optimization.

42 ENGINEERING↗

Speckle-based three-dimensional velocity measurement using spatial filtering velocimetry

We present an optical method for measuring the real-time three-dimensional (3D) translational velocity of a diffusely scattering rigid object observed through an imaging system. The method is based on a combination of the motion of random speckle patterns and regular fringe patterns. The speckle pattern is formed in the observation plane of the imaging system due to reflection from an area of the object illuminated by a coherent light source. The speckle pattern translates in response to in-plane translation of the object, and the presence of an angular offset reference wave coinciding with the speckle pattern in the observation plane gives rise to interference, resulting in a fringe pattern that translates in response to the out-of-plane translation of the object. Numerical calculations are performed to evaluate the dynamic properties of the intensity distribution and the response of realistic spatial filters designed to measure the three components of the object's translational velocity. Furthermore, experimental data are presented that demonstrate full 3D velocity measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ensemble variational Fokker-Planck methods for data assimilation

Particle flow filters solve Bayesian inference problems by smoothly transforming a set of particles into samples from the posterior distribution. Particles move in state space under the flow of an McKean-Vlasov-Itˆo process. This work introduces the Variational Fokker-Planck (VFP) framework for data assimilation, a general approach that includes previously known particle flow filters as special cases. The McKean-Vlasov-Itˆo process that transforms particles is defined via an optimal drift that depends on the selected diffusion term. It is established that the underlying probability density - sampled by the ensemble of particles - converges to the Bayesian posterior probability density. For a finite number of particles the optimal drift contains a regularization term that nudges particles toward becoming independent random variables. Based on this analysis, we derive computationally-feasible approximate regularization approaches that penalize the mutual information between pairs of particles, and avoid particle collapse. Moreover, the diffusion plays a role akin to a particle rejuvenation approach that aims to alleviate particle collapse. The VFP framework is very flexible. Different assumptions on prior and intermediate probability distributions can be used to implement the optimal drift, and localization and covariance shrinkage can be applied to alleviate the curse of dimensionality. A robust implicit-explicit method is discussed for the efficient integration of stiff McKean- Vlasov-Itˆo processes. Here, the effectiveness of the VFP framework is demonstrated on three progressively more challenging test problems, namely the Lorenz ’63, Lorenz ’96 and the quasi-geostrophic equations.

97 MATHEMATICS AND COMPUTING↗

NEW METHOD FOR REMOVAL OF SPECTRAL INTERFERENCES FOR BERYLLIUM ASSAY USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY

Beryllium has been used widely in specific areas of nuclear technology. Frequent monitoring of air and possible contaminated surfaces in U.S Department of Energy (DOE) facilities is required to identify potential health risks and to protect DOE workers from beryllium-contaminated dust. A new method has been developed to rapidly remove spectral interferences prior to beryllium (Be) measurement by inductively-coupled plasma atomic emission spectrometry (ICP-AES). The ion exchange separation removes uranium (U), thorium (Th), niobium (Nb), vanadium (V), molybdenum (Mo), zirconium (Zr), tungsten (W), iron (Fe), chromium (Cr), cerium (Ce), erbium (Er) and titanium (Ti). A stacked column consisting of Diphonix Resin{reg_sign} and TEVA Resin{reg_sign} reduces the levels of the spectral interferences so that low level Be measurements can be performed accurately. If necessary, an additional anion exchange separation can be used for further removal of interferences, particularly chromium. The method has been tested using spiked filters, spiked wipe samples and certified reference material standards with high levels of interferences added. The method provides very efficient removal of spectral interferences with very good accuracy and precision for beryllium on filters or wipes. A vacuum box system is employed to reduce analytical time and reduce labor costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative 2D thermometry in turbulent sooting non-premixed flames using filtered Rayleigh scattering

This paper demonstrates the application of a thermometry method in turbulent sooting non-premixed flames using filtered Rayleigh scattering (FRS). Fuel tailoring is used to establish a specific C 2 H 2 -based fuel mixture such that temperature can be determined accurately by a single FRS measurement over the entirety of mixture fraction space, or equivalently, for all relevant thermo-chemical states. Evaluation is performed in a hierarchy of flows to establish measurement precision and accuracy. Initial assessments in a series of heated fuel mixtures; non-sooting, near-adiabatic flat flames; and laminar non-premixed sooting flames show accuracy of the approach over a full range of expected temperatures and high single-shot measurement precision (e.g., 65 < <#comment/> S N R < <#comment/> 80 ) for temperatures between 1900 and 2200 K. Subsequently, 2D temperature measurements are evaluated in a turbulent non-premixed sooting flame. For the current fuel mixture, the local mixture-averaged Rayleigh scattering cross section is nearly constant over all composition space, and thus traditional laser Rayleigh scattering (LRS) is used as a measurement standard in the absence of soot. The results show excellent agreement between the proposed FRS thermometry approach and LRS in non-sooting regions. In the presence of soot, the proposed FRS-based approach shows no signs of interference. In addition, 2D temperature imaging shows high SNR (60–74) over all temperature conditions. Thus, we believe the proposed methodology successfully provides a high-resolution 2D temperature method under turbulent sooting flame conditions.

Pu, Jinpeng↗

Radiochemical Methodology Applied To Determination of gamma-Emitting Radionuclides In Waste Samples From IEA-R1 Reactor - 17265

The Brazilian reactor IEA-R1 has been in operation since 1957. It is an open pool-type nuclear research reactor, operating at 2 to 5 MW that uses water as coolant, moderator and biological shield. Polypropylene filter cartridges are part of the water treatment system of the reactor and become radioactive as they remove suspended solid material from the cooling water during the operation of the reactor. Annually, the replacement of the filters from the reactor's water treatment system generates about 36 units. The development of a method for the characterization of the radionuclides present in the filters is required for routine operation in the Radioactive Waste Management Facility (RWMF) in order to determine the radioisotopic inventory of the waste packages. Wastes from nuclear reactors contain transuranic elements, activation and fission products, only few of them emitting gamma radiation measurable by simple gamma scanning methods. The method of the Scaling Factors (SF) uses empirically determined proportions between the concentrations of Difficult to Measure (DTM) radionuclides and that of easily measurable gamma emitters called Key Nuclide (KN), to calculate DTM concentrations. The objective of this study is to describe a method of the dissolution of the filter cartridges for determination of gamma emitting radionuclides. To determine the activity of a sample by means of of gamma spectrometry, it is necessary previous knowledge of the efficiency curve for a given geometry, which can be obtained by calibrating the efficiency and energy of the detector. The need to dissolve the filter cartridges has arisen given the difficulty in obtaining a standard source with the same filter geometry. Therefore, for this work, the calibration curve was constructed using a mixed gamma-ray standard with known activities, same geometry, density, physical state and chemical composition of the source to be analyzed. A sample with background count (BG) was prepared and analyzed under the same conditions as the samples and the result was subtracted from the results obtained for each filter sample. After many tests, it was possible to establish a method for the dissolution of filter cartridges for the determination of gamma-emitting radionuclides. A mixed gamma-ray standard was produced in liquid form, containing the following radionuclides: {sup 241}Am, {sup 137}Cs and {sup 60}Co, which have photo-peaks at the following energies: 59.54, 661.66 and 1332.49 keV, respectively. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generator Dynamic Model Validation and Parameter Calibration Using Phasor Measurements at the Point of Connection

Disturbance data recorded by phasor measurement units (PMU) offers opportunities to improve the integrity of dynamic models. However, manually tuning parameters through play-back events demands significant efforts and engineering experiences. In this paper, a calibration method using the extended Kalman filter (EKF) technique is proposed. The formulation of EKF with parameter calibration is discussed. Case studies are presented to demonstrate its validity. The proposed calibration method is cost-effective, complementary to traditional equipment testing for improving dynamic model quality.

Huang, Zhenyu↗

Representation of Probability Density Functions from Orbit Determination using the Particle Filter

Statistical orbit determination enables us to obtain estimates of the state and the statistical information of its region of uncertainty. In order to obtain an accurate representation of the probability density function (PDF) that incorporates higher order statistical information, we propose the use of nonlinear estimation methods such as the Particle Filter. The Particle Filter (PF) is capable of providing a PDF representation of the state estimates whose accuracy is dependent on the number of particles or samples used. For this method to be applicable to real case scenarios, we need a way of accurately representing the PDF in a compressed manner with little information loss. Hence we propose using the Independent Component Analysis (ICA) as a non-Gaussian dimensional reduction method that is capable of maintaining higher order statistical information obtained using the PF. Methods such as the Principal Component Analysis (PCA) are based on utilizing up to second order statistics, hence will not suffice in maintaining maximum information content. Both the PCA and the ICA are applied to two scenarios that involve a highly eccentric orbit with a lower apriori uncertainty covariance and a less eccentric orbit with a higher a priori uncertainty covariance, to illustrate the capability of the ICA in relation to the PCA.

Mashiku, Alinda K.↗

Modeling of a negative ion source. II. Plasma-gas coupling in the extraction region

The production, destruction, and transport of H{sup -} in the extraction region of a negative ion source are investigated with a 1D(z)-3V particle-in-cell electrostatic code. The motion of charged particles (e, H{sup +}, H{sub 2}{sup +}, and H{sup -}) in their self-consistent electric field is coupled with the neutral particles [H(n=1) and H{sub 2}(X{sup 1}{sigma}{sub g}{sup +}, v=0,...,14)] dynamics and vibrational kinetics of H{sub 2}. Neutral influxes into the domain are determined by the simulation of the expansion region. Surface and volumetric processes involving plasma and neutrals have been included by using different Monte Carlo collision methods. Calculations show the influence of the plasma grid bias and of the magnetic filter on the plasma parameter profiles. In particular, a transition from classical to complete reverse sheath is observed using a positively biased plasma grid. The influence of the magnetic filter is small. The importance of the hot-atom mechanism on the surface negative ion production is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Navigation strategy and filter design for solar electric missions

Methods which have been proposed to improve the navigation accuracy for the low-thrust space vehicle include modifications to the standard Sequential- and Batch-type orbit determination procedures and the use of inertial measuring units (IMU) which measures directly the acceleration applied to the vehicle. The navigation accuracy obtained using one of the more promising modifications to the orbit determination procedures is compared with a combined IMU-Standard. The unknown accelerations are approximated as both first-order and second-order Gauss-Markov processes. The comparison is based on numerical results obtained in a study of the navigation requirements of a numerically simulated 152-day low-thrust mission to the asteroid Eros. The results obtained in the simulation indicate that the DMC algorithm will yield a significant improvement over the navigation accuracies achieved with previous estimation algorithms. In addition, the DMC algorithms will yield better navigation accuracies than the IMU-Standard Orbit Determination algorithm, except for extremely precise IMU measurements, i.e., gyroplatform alignment .01 deg and accelerometer signal-to-noise ratio .07. Unless these accuracies are achieved, the IMU navigation accuracies are generally unacceptable.

Tapley, B. D.↗

Recursive Filtering And Smoothing In Robot Dynamics

Techniques developed originally for electronic systems also useful for multibody mechanical systems. Report summarizes methods developed to solve nonlinear forward-dynamics problem for robot of multiple-link arms connected by joints. Primary objective to show equivalence between recursive methods of dynamical analysis and some filtering and smoothing techniques from state-estimation theory.

Rodriguez, Guillermo↗

Filter casting nanoscale porous materials

A method of producing nanoporous material includes the steps of providing a liquid, providing nanoparticles, producing a slurry of the liquid and the nanoparticles, removing the liquid from the slurry, and producing monolith.

36 MATERIALS SCIENCE↗