Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

Initial assessment of the operability of the VHTR-HTE nuclear hydrogen plant.

The generation of hydrogen from nuclear power will need to compete on three fronts: production, operability, and safety to be viable in the energy marketplace of the future. This work addresses the operability of a coupled nuclear and hydrogen-generating plant while referring to other work for progress on production and safety. Operability is a measure of how well a plant can meet time-varying production demands while remaining within equipment limits. It can be characterized in terms of the physical processes that underlie operation of the plant. In this work these include the storage and transport of energy within components as represented by time constants and energy capacitances, the relationship of reactivity to temperature, and the coordination of heat generation and work production for a near-ideal gas working fluid. Criteria for assessing operability are developed and applied to the Very High Temperature Reactor coupled to the High Temperature Steam Electrolysis process, one of two DOE/INL reference plant concepts for hydrogen production. Results of preliminary plant control and stability studies are described. A combination of inventory control in the VHTR plant and flow control in the HTSE plant proved effective for maintaining hot-side temperatures near constant during quasi-static change in hydrogen production rate. Near constant electrolyzer outlet temperature is achieved by varying electrolyzer cell area to control cell joule heating. It was found that rates of temperature change in the HTSE plant for a step change in hydrogen production rate are largely determined by the thermal characteristics of the electrolyzer. It's comparatively large thermal mass and the presence of recuperative heat exchangers result in a tight thermal coupling of HTSE components to the electrolyzer. It was found that thermal transients arising in the chemical plant are strongly damped at the reactor resulting in a stable combined plant. The large Doppler reactivity component, three times greater than next reactivity component, per unit temperature, is mainly responsible. This is the case even when one of the conditions for out-of-phase oscillations between reactor inlet and outlet temperature, a large time for transport of process heat between the reactor and chemical plant, exists.

08 HYDROGEN↗

Multi-Pressure Rail System Design with Variable Pressure Control Strategy

This paper presents the design and the control method of a Multiple Pressure Rail system (MPR) with a variable pressure control logic that allows minimization of throttling loss, therefore, increasing the overall fluid power actuation efficiency. An MPR system allows controlling hydraulic actuators with a pressure control logic, as opposed to traditional flow control logics which are well established in mobile applications. A proper setting of the number of pressure rails and the pressure level in each rail permits optimizing the system efficiency of an MPR solution. MPR systems have been recently proposed with different purposes, but seldom adopt variable pressure control strategies to manage the pressure variations in the rails. Moreover, the related past work attempts to maximize the energy recovery during overrunning load conditions. This paper, instead, addresses the case of an MPR system that handles a multitude of hydraulic functions without significant overrunning loads, as it occurs in many mobile applications such as in agriculture. The paper first presents the design alternatives considered for the MPR system, including the supply, the control valves, and the controller. Second, a dedicated test rig is developed to support experimental activities and validations of a lumped parameter model developed within this research to develop the MPR control strategy. The results describe the operating features of the proposed MPR solution. By considering the case of a traditional LS system, the paper results also show how system efficiency can be highly improved, with energy savings in the order of 49%

24 POWER TRANSMISSION AND DISTRIBUTION↗

Viscous drag reduction in boundary layers

The present volume discusses the development status of stability theory for laminar flow control design, applied aspects of laminar-flow technology, transition delays using compliant walls, the application of CFD to skin friction drag-reduction, active-wave control of boundary-layer transitions, and such passive turbulent-drag reduction methods as outer-layer manipulators and complex-curvature concepts. Also treated are such active turbulent drag-reduction technique applications as those pertinent to MHD flow drag reduction, as well as drag reduction in liquid boundary layers by gas injection, drag reduction by means of polymers and surfactants, drag reduction by particle addition, viscous drag reduction via surface mass injection, and interactive wall-turbulence control.

Bushnell, Dennis M.↗

Wind Tunnel Testing of AFC over a Deflected Aileron on the High-Lift Common Research Model

Active flow control (AFC) using discrete fluidic actuators distributed along the span, just upstream of the deflected aileron of the 10% scale high-lift version of the Common Research Model (CRM-HL), was evaluated during a wind tunnel test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. For this set of experiments, a new outboard section was fabricated incorporating a deflectable aileron. Aileron deflection angles of 0, 7.5, 16, and 25 were investigated. This experimental investigation is in response to a recent study by Boeing potential to use AFC with a drooped aileron during takeoff to improve lift-to-drag ratio (L/D) by as much as 5%, depending on AFC mass flow rate. AFC is used at deflection angles above the nominal deflection of 7.5 to control the resulting flow separation that occurs and potentially improve L/D. Improvements in aircraft low-speed L/D can affect vehicle range and/or payload. Tuft flow visualization data, steady and unsteady surface pressure data, and force and moment data are used to compare the flowfields with and without AFC. Parameters varied include actuator momentum coefficient and aileron deflection angle. The surface pressure and tuft flow visualization results indicate that without AFC, the flow over a majority of the aileron upper surface is separated for aileron deflection angles larger than 7.5. When AFC is applied, the flow is reattached to the aileron. Force and moment results show that a local increase in lift leads to an increase in L/D of at least 3.5% using mass flow rates thought to be available from air sources onboard a commercial transport.

AFC↗

Wind Tunnel Testing of AFC over a Deflected Aileron on the High-Lift Common Research Model

Active flow control (AFC) using discrete fluidic actuators distributed along the span, just upstream of the deflected aileron of the 10% scale high-lift version of the Common Research Model (CRM-HL), was evaluated during a wind tunnel test in the NASA Langley 14- by 22-Foot Subsonic Tunnel. For this set of experiments, a new outboard section was fabricated incorporating a deflectable aileron. Aileron deflection angles of 0, 7.5, 16, and 25 were investigated. This experimental investigation is in response to a recent study by Boeing potential to use AFC with a drooped aileron during takeoff to improve lift-to-drag ratio (L/D) by as much as 5%, depending on AFC mass flow rate. AFC is used at deflection angles above the nominal deflection of 7.5 to control the resulting flow separation that occurs and potentially improve L/D. Improvements in aircraft low-speed L/D can affect vehicle range and/or payload. Tuft flow visualization data, steady and unsteady surface pressure data, and force and moment data are used to compare the flowfields with and without AFC. Parameters varied include actuator momentum coefficient and aileron deflection angle. The surface pressure and tuft flow visualization results indicate that without AFC, the flow over a majority of the aileron upper surface is separated for aileron deflection angles larger than 7.5. When AFC is applied, the flow is reattached to the aileron. Force and moment results show that a local increase in lift leads to an increase in L/D of at least 3.5% using mass flow rates thought to be available from air sources onboard a commercial transport.

AFC↗

Petascale Adaptive CFD (ALCF ESP Technical Report)

The aerodynamic simulations of this project involve modeling of active flow control based on synthetic jet actuation that has been shown experimentally to produce large-scale flow changes (e.g., re-attachment of separated flow or virtual aerodynamic shaping of lifting surfaces) from micro-scale input. This micro-scale input consists for instance in 0.1 W piezoelectric disk which resonate in a cavity alternately and pushes/pulls out/in the fluid through a small slit to create small-scale vortical structures that interact with, and thereby dramatically alter, the cross flow. This process has yet to be understood fundamentally. Synthetic jet actuators offer the prospect of not only augmenting lift but also other forces and moments in a dynamic and controlled fashion for a range of operating conditions. They have been demonstrated to restore and maintain flow attachment and reduce vibrations in wind turbine blades during dynamic pitch, thereby reducing unsteady loads on gearboxes that are currently the prime failure point. In virtual-shape flight control surfaces for aerial vehicles (including commercial airplanes), conventional control surfaces (e.g., flaps, rudder, etc.) can be augmented or even replaced with active flow control, thus improving their lift-to-drag ratio and/or control power. The goal of the numerical simulations proposed in this project is to provide a complementary and detailed view of the flow interactions at a much higher Reynolds number, approaching engineering application scales for the first time.

Jansen, Kenneth E.↗

Dynamics of Three-Dimensional Shock-Wave/Boundary-Layer Interactions

Advances in measuring and understanding separated, nominally two-dimensional (2D) shock-wave/turbulent-boundary-layer interactions (STBLI) have triggered recent campaigns focused on three-dimensional (3D) STBLI, which display far greater configuration diversity. Nonetheless, unifying properties emerge for semi-infinite interactions, taking the form of conical asymptotic behavior where shock-generator specifics become insignificant. The contrast between 2D and 3D separation is substantial; the skewed vortical structure of 3D STBLI reflects the essentially 2D influence of the boundary layer on the 3D character of the swept shock. As with 2D STBLI, conical interactions engender prominent spectral content below that of the turbulent boundary layer. However, the uniform separation length scale, which is crucial to normalizing the lowest-frequency dynamics in 2D STBLI, is absent. Comparatively, the spectra of 3D STBLI are more representative of the mid-frequency, convective, shear-layer dynamics in 2D, while phenomena associated with 2D separation-shock breathing are muted. Asymptotic behavior breaks down in many regions important to 3D-STBLI dynamics, occurring in a configuration-dependent manner. Aspects of inceptive regions near shock generators and symmetry planes are reviewed. Focused efforts toward 3D modal and nonmodalanalyses, moving-shock/boundary-layer interactions, fluid/structure interactions, and flow control are suggested as directions for future work.

42 ENGINEERING↗

A two-dimensional adaptive-wall test section with ventilated walls in the Ames 2- by 2-foot transonic wind tunnel

The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attach of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

Schairer, Edward T.↗

Two-dimensional adaptive-wall tests in the NASA Ames two- by two-foot transonic wind tunnel

The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attack of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

Schairer, Edward T.↗

Advanced Flexible Transformers

Advanced grid solutions are comprised of advanced transmission technologies and grid enhancing technologies. In this webinar, experts will provide participants with insights into eight advanced grid solutions. The advanced transmission technologies that will be discussed include point-to-point high voltage direct current and advanced conductoring and the grid enhancing technologies that experts will explore include topology optimization, advanced power flow control, dynamic line rating, energy storage, virtual power plants, and advanced flexible transformers

flexible power transformer, power flow controller,↗

Microcomputer based controller for the Langley 0.3-meter Transonic Cryogenic Tunnel

Flow control of the Langley 0.3-meter Transonic Cryogenic Tunnel (TCT) is a multivariable nonlinear control problem. Globally stable control laws were generated to hold tunnel conditions in the presence of geometrical disturbances in the test section and precisely control the tunnel states for small and large set point changes. The control laws are mechanized as four inner control loops for tunnel pressure, temperature, fan speed, and liquid nitrogen supply pressure, and two outer loops for Mach number and Reynolds number. These integrated control laws have been mechanized on a 16-bit microcomputer working on DOS. This document details the model of the 0.3-m TCT, control laws, microcomputer realization, and its performance. The tunnel closed loop responses to small and large set point changes were presented. The controller incorporates safe thermal management of the tunnel cooldown based on thermal restrictions. The controller was shown to provide control of temperature to + or - 0.2K, pressure to + or - 0.07 psia, and Mach number to + or - 0.002 of a given set point during aerodynamic data acquisition in the presence of intrusive geometrical changes like flexwall movement, angle-of-attack changes, and drag rake traverse. The controller also provides a new feature of Reynolds number control. The controller provides a safe, reliable, and economical control of the 0.3-m TCT.

Balakrishna, S.↗

Large-Scale Wind-Tunnel Tests and Evaluation of the Low-Speed Performance of a 35 deg Sweptback Wing Jet Transport Model Equipped with a Blowing Boundary-Layer-Control Flap and Leading-Edge Slat

A wind-tunnel investigation was conducted to determine the effect of trailing-edge flaps with blowing-type boundary-layer control and leading-edge slats on the low-speed performance of a large-scale jet transport model with four engines and a 35 deg. sweptback wing of aspect ratio 7. Two spanwise extents and several deflections of the trailing-edge flap were tested. Results were obtained with a normal leading-edge and with full-span leading-edge slats. Three-component longitudinal force and moment data and boundary-layer-control flow requirements are presented. The test results are analyzed in terms of possible improvements in low-speed performance. The effect on performance of the source of boundary-layer-control air flow is considered in the analysis.

Hickey, David H.↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Active Control of Separation From the Flap of a Supercritical Airfoil

Active flow control in the form of periodic zero-mass-flux excitation was applied at several regions on the leading edge and trailing edge flaps of a simplified high-lift system t o delay flow separation. The NASA Energy Efficient Transport (EET) supercritical airfoil was equipped with a 15% chord simply hinged leading edge flap and a 25% chord simply hinged trailing edge flap. Detailed flow features were measured in an attempt to identify optimal actuator placement. The measurements included steady and unsteady model and tunnel wall pressures, wake surveys, arrays of surface hot-films, flow visualization, and particle image velocimetry (PIV). The current paper describes the application of active separation control at several locations on the deflected trailing edge flap. High frequency (F(+) approx.= 10) and low frequency amplitude modulation (F(+)AM approx.= 1) of the high frequency excitation were used for control. Preliminary efforts to combine leading and trailing edge flap excitations are also reported.

Melton, La Tunia Pack↗

Control of Meridional Flow by a Non-Uniform Rotational Magnetic Field

The diffusive mass transfer of species during crystal growth in vertical ampoules is significantly affected by fluid flow in the liquid mother phase (melt). For electrically conductive melts, an elegant way of remotely inducing and controlling this flow is by utilizing a uniform rotational magnetic field (RMF) in the transverse direction. It induces an azimuthal flow which tends to homogenize the thermal and solutal fields. The rotating field also reduces the diffusion boundary layer, stabilizes temperature fluctuations, and promotes better overall crystal growth. For moderate strengths of the applied magnetic field (2-20 m Tesla) with frequencies of up to 400 Hz, the induced secondary meridional flow becomes significant. It typically consists of one roll at the bottom of the liquid column and a second roll (vortex) at the top. The flow along the centerline (ampoule axis) is directed from the growing solid (interface) towards the liquid (melt). In case of convex interfaces (e.g. in floating zone crystal growth) such flow behavior is beneficial since it suppresses diffusion at the center. However, for concave interfaces (e.g. vertical Bridgman crystal growth) such a flow tends to exacerbate the situation in making the interface shape more concave. It would be beneficial to have some control of this meridional flow- for example, a single recirculating cell with controllable direction and flow magnitude will make this technique even more attractive for crystal growth. Such flow control is a possibility if a non-uniform PNE field is utilized for this purpose. Although this idea has been proposed earlier, it has not been conclusively demonstrated so far. In this work, we derive the governing equations for the fluid dynamics for such a system and obtain solutions for a few important cases. Results from parallel experimental measurements of fluid flow in a mercury column subjected to non-uniform RMF will also be presented.

Mazuruk, Konstantin↗