Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Feedback Control of an Azimuthal Oscillation in the E x B Discharge of Hall Thrusters

Feedback control of a low-frequency azimuthal wave known as a "rotating spoke" in the ExB discharge of a cylindrical Hall thruster was demonstrated. The rotating spoke is an m=1 azimuthal variation in density, electron temperature, and potential that rotates at about 10% of the local E x B electron rotation speed. It causes increased electron transport across the magnetic field and is suspected to be an ionization wave. Feedback control of this wave required special consideration because, although it causes a rotating azimuthal variation in the current density to the anode, it does not show up as a signal in the total thruster discharge current. Therefore, an extra source of information was needed to track the oscillation, which was addressed by using a special anode that was split azimuthally into four segments. The current to each segment oscillates as the rotating spoke passes over it, and feedback is accomplished by resistors connected in series with each anode segment which cause the voltage on a segment to decrease in proportion to the current through that segment. The feedback resulted in the disappearance of a coherent azimuthal wave and a decrease in the time-averaged total discharge current by up to 13.2%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigations of electron density and ion energy distributions in dual-frequency capacitively coupled plasmas for Ar/CF{sub 4} and Ar/O{sub 2}/CF{sub 4} discharges

The electron density and ion energy distribution (IED) are investigated in low-pressure dual-frequency capacitively coupled Ar/CF{sub 4} (90%/10%) and Ar/O{sub 2}/CF{sub 4} (80%/10%/10%) plasmas. The relations between controllable parameters, such as high-frequency (HF) power, low-frequency (LF) power and gas pressure, and plasma parameters, such as electron density and IEDs, are studied in detail by utilizing a floating hairpin probe and an energy resolved quadrupole mass spectrometer, respectively. In our experiment, the electron density is mainly determined by the HF power and slightly influenced by the LF power. With increasing gas pressure, the electron density first goes up rapidly to a maximum value and then decreases at various HF and LF powers. The HF power also plays a considerable role in affecting the IEDs under certain conditions and the ion energy independently controlled by the LF source is discussed here. For clarity, some numerical results obtained from a two-dimensional fluid model are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial symmetry breaking in single-frequency CCP discharge with transverse magnetic field

An independent control of the flux and energy of ions impacting on an object immersed in a plasma is often desirable for many industrial processes such as microelectronics manufacturing. We demonstrate that a simultaneous control of these quantities is possible by a suitable choice of a static magnetic field applied parallel to the plane electrodes in a standard single frequency capacitively coupled plasma device. Our particle-in-cell simulations show a 60% reduction in the sheath width (that improves control of ion energy) and a fourfold increase in the ion flux at the electrode as a consequence of the altered ion and electron dynamics due to the ambient magnetic field. A detailed analysis of the particle dynamics is presented, and the optimized operating parameters of the device are discussed. In conclusion, the present technique offers a simple and attractive alternative to conventional dual frequency based devices that often suffer from undesirable limitations arising from frequency coupling and electromagnetic effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of the frequency modulation of optical signals with a high frequency deviation parameter

A new type of an integrated optical modulator for the frequency coding of optical signals is developed and fabricated. The modulator operation is based on the original technology of the electric control of a Bragg grating. The frequency modulation of an optical signal with the frequency deviation of 25 GHz is demonstrated experimentally. The modular was used to transfer the ASCII code through an optical fibre. (optical communication)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modernization of PLC-Based Control Systems at SNS

When the SNS site was built around 20 years ago, the Conventional Facilities (CF) control systems were de-signed using 2 communication protocols to allow pro-grammable logic controllers (PLCs) to interface with motors, variable frequency drives (VFDs), and remote input and output (I/O) devices. The protocol chosen to control motors and VFDs is DeviceNet, a CANbus-based protocol developed by Allen-Bradley, a subsidiary of Rockwell Automation. The protocol chosen to communi-cate with remote I/O is ControlNet, another protocol developed by Allen-Bradley. Both of these protocols are obsolete and present reliability and maintainability is-sues, particularly DeviceNet. As the Control Systems Section at SNS is working to modernize control systems throughout the machine, a major goal for PLC-based systems is to remove the obsolete communication proto-cols in favor of standard, ubiquitous Ethernet. To this end, any new VFDs installed use Ethernet communica-tion. Many VFDs are currently being replaced in the Central Utilities Building (CUB) and the Central Exhaust Facility (CEF) and are being removed from DeviceNet in favor of Ethernet communication. Planning is underway to retrofit Eaton Intelligent Technology motor control centers (MCCs) in the Target Building to remove particu-larly troublesome DeviceNet adaptors and replace them with Ethernet adaptors for each motor starter. The Con-trolNet network in the CUB has been demolished, with I/O drops integrated into a local Ethernet network, im-proving sustainability and maintainability.

Beaushaw, Isaiah [ORNL]↗

Differential Light-Shift Cancellation in a Magnetic-Field-Insensitive Transition of {sup 87}Rb

The precise measurement of transition frequencies of trapped atomic samples is susceptible to inaccuracy arising from the inhomogeneous differential shift of the relevant energy levels in the presence of the trapping fields. We demonstrate near-complete cancellation of the differential ac Stark shift (''light shift'') of a two-photon magnetic-field-insensitive microwave hyperfine (clock) transition in {sup 87}Rb atoms trapped in an optical lattice. Up to 95(2)% of the differential light shift is cancelled while maintaining magnetic-field insensitivity. This technique should have applications in quantum information and frequency metrology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feedback control of an azimuthal oscillation in the E Multiplication-Sign B discharge of Hall thrusters

Feedback control of a low-frequency azimuthal wave known as a 'rotating spoke' in the E Multiplication-Sign B discharge of a cylindrical Hall thruster was demonstrated. The rotating spoke is an m = 1 azimuthal variation in density, electron temperature, and potential that rotates at about 10% of the local E Multiplication-Sign B electron rotation speed. It causes increased electron transport across the magnetic field and is suspected to be an ionization wave. Feedback control of this wave required special consideration because, although it causes a rotating azimuthal variation in the current density to the anode, it does not show up as a signal in the total thruster discharge current. Therefore, an extra source of information was needed to track the oscillation, which was addressed by using a special anode that was split azimuthally into four segments. The current to each segment oscillates as the rotating spoke passes over it, and feedback is accomplished by resistors connected in series with each anode segment which causes the voltage on a segment to decrease in proportion to the current through that segment. The feedback resulted in the disappearance of a coherent azimuthal wave and a decrease in the time-averaged total discharge current by up to 13.2%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron beam energy stabilization using a neural network hybrid controller at the Australian Synchrotron Linac.

This paper describes the implementation of a neural network hybrid controller for energy stabilization at the Australian Synchrotron Linac. The structure of the controller consists of a neural network (NNET) feed forward control, augmented by a conventional Proportional-Integral (PI) feedback controller to ensure stability of the system. The system is provided with past states of the machine in order to predict its future state, and therefore apply appropriate feed forward control. The NNET is able to cancel multiple frequency jitter in real-time. When it is not performing optimally due to jitter changes, the system can successfully be augmented by the PI controller to attenuate the remaining perturbations. With a view to control the energy and bunch length at the FERMI{at}Elettra Free Electron Laser (FEL), the present study considers a neural network hybrid feed forward-feedback type of control to rectify limitations related to feedback systems, such as poor response for high jitter frequencies or limited bandwidth, while ensuring robustness of control. The Australian Synchrotron Linac is equipped with a beam position monitor (BPM), that was provided by Sincrotrone Trieste from a former transport line thus allowing energy measurements and energy control experiments. The present study will consequently focus on correcting energy jitter induced by variations in klystron phase and voltage.

43 PARTICLE ACCELERATORS↗

Real-Time Digital Simulation of Inertial Response with Hardware-in-the-Loop Implementation on the CART3 Wind Turbine at the National Wind Technology Center

With increasing penetrations of wind power on electric grids, the stability and reliability of interconnected power systems may be impacted. In some countries that have developed renewable energy sources and systems, grid codes have been revised to require wind power plants (WPPs) to provide ancillary services to support the power system frequency in case of severe grid events. To do this, wind turbine generators (WTGs) should be deloaded to reserve a certain amount of active power for primary frequency response; however, deloading curtails annual energy production, and the market for this type of service needs to be further developed. In this report, we focus on the temporary frequency support provided by WTGs through inertial response. WTGs have potential to provide inertial response, but appropriate control methods should be implemented. With the implemented inertial control methods, wind turbines are capable of increasing their active power output by releasing some of their stored kinetic energy when a frequency excursion occurs. Active power can be temporarily boosted above the maximum power points, after which the rotor speed decelerates, and subsequently an active power output reduction restores the kinetic energy. In this report, we develop two types of models for wind power systems: the first is common, based on the wind power aerodynamic equation, and the power coefficient can be regressed using nonlinear functions; the second is much more complicated, wherein the wind turbine system is modeled using the Fatigue, Aerodynamics, Structures, and Turbulence Modeling (FAST) tool with several degrees of freedoms. A nine-bus test power system is built in Simulink and the Real-Time Digital Simulator, respectively, which are used to evaluate the frequency support performance of the WPPs. We implement two distinct types of inertial control methods in the modeled wind turbines: frequency-based inertial control (FBIC) and stepwise inertial control (SIC). We compare the performances of the two methods in terms of their frequency nadirs, rates of change of frequency, and recovery times. We conclude the results under various wind speeds and penetration cases, which provide insight into designing the inertial response of WTGs. Further, we discuss the impact of the parameters on the performance of the inertial control methods. We evaluate both the scaling factors for the FBIC method and the slope values for the TLIC methods. The simulation work shows the characteristics of different inertial responses compared to conventional synchronous generators. Based on the simulation results, we modify, improve, and test the inertial control methods under a more realistic wind turbine model based on FAST. We then validate the inertial responses under highly turbulent wind conditions generated by TurbSim, and we examine their influences on the turbine mechanical components. The extensive simulation proves the effectiveness of the proposed inertial control methods as well as the nine-bus test power system. We then reconsider the parameters. We rebuild the same test power system using Real time Simulator Computer Aided Design (RSCAD), and we implement the inertial control methods in the real Controls Advanced Research Turbine (CART3), which is prepared for the hardware-in-the-loop field-test simulation. After the setups for the hardware and software hybrid simulation platform are complete, the inertial response is further tested on a real wind turbine for the first time, in which CART3 release the controlled inertial response against the emulated frequency excursion, provided by the real-time simulated power system test bed in RTDS.

17 WIND ENERGY↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CERTS Microgrid Laboratory Test Bed

The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2) an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources. These techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations,and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers Standard 1547 and power quality requirements. The electrical protection system was able to distinguish between normal and faulted operation. The controls were found to be robust under all conditions, including difficult motor starts and high impedance faults. The results from these tests are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or more of the CERTS Microgrid concepts. Future planned microgrid work involves unattended continuous operation of the microgrid for 30 to 60 days to determine how utility faults impact the operation of the microgrid and to gage the power quality and reliability improvements offered by microgrids.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pacific Northwest GridWise™ Testbed Demonstration Projects; Part II. Grid Friendly™ Appliance Project

Fifty residential electric water heaters and 150 new residential clothes dryers were modified to respond to signals received from underfrequency, load-shedding appliance controllers. Each controller monitored the power-grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances were installed and monitored for more than a year at residential sites at three locations in Washington and Oregon. The controllers and their appliances responded reliably to each shallow underfrequency event—an average of one event per day—and shed their loads for the durations of these events. Appliance owners reported that the appliance responses were unnoticed and caused little or no inconvenience for the homes’ occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

Analysis of Power-Maximizing Region 2 Controllers for Wind and Marine Turbines

Wind and marine energy are rapidly growing and complementary technologies that share some techniques for simplified modeling and control, particularly in below-rated flow speeds. A turbine operator has several choices of controller for maximizing power in Region 2. The simple and ubiquitous KΩ 2 control law is often effective but limited in its flexibility. Alternative controllers use reference tracking to split the control objectives into a low-bandwidth optimal tip-speed ratio tracking loop to maximize steady-state power and a higher-bandwidth proportional-integral control loop to reject inflow turbulence. Several options exist for identifying the slowly varying optimal set point during operation, based on estimating the inflow velocity or filtering the power or torque signals. This study compares the trade-offs between performance and other design priorities for a few choices of reference-tracking controller in the literature for reference wind and marine turbines. Analysis is performed in the frequency domain using the linearization of each controller, and the impact of turbulent disturbances on the closed-loop system is described. The controllers are simulated in OpenFAST to analyze their performance with higher-order nonlinear turbine dynamics.

17 WIND ENERGY↗