Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

Ghaffaroam. Reza↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

The Future of Vehicle Grid Integration: Harnessing the Flexibility of EV Charging

This document lays out a shared vision for a beneficial, EV-integrated future where EVs are safely and securely connected, reliably served, and harmonized with the electric grid. It was developed as part of the U.S. Department of Energy’s (DOE) EVGrid Assist initiative. Stakeholder input was gathered through individual and collective conversations, including eight listening sessions with more than 100 participants representing utilities of different sizes and operating structures, manufacturers of vehicles and chargers, national associations, standards organizations, Tribes, fleet managers, consumer advocates, charging network operators, community-based organizations, utility regulators, consultants, vendors, labor, and environmental justice organizations. This document focuses on the future of electric on-road U.S. transportation, specifically the integration of light-duty vehicles (LDV) and medium- and heavy-duty vehicles (MHDV) and their charging infrastructure with the electric grid. However, many of the insights here may apply to electrifying other transportation modes, as well as other distributed energy resources (DER).

EVGrid Assist initiative, EV-integrated future, el↗

The Future of Vehicle Grid Integration: Harnessing the Flexibility of EV Charging

This document lays out a shared vision for a beneficial, EV-integrated future where EVs are safely and securely connected, reliably served, and harmonized with the electric grid. It was developed as part of the U.S. Department of Energy’s (DOE) EVGrid Assist initiative. Stakeholder input was gathered through individual and collective conversations, including eight listening sessions with more than 100 participants representing utilities of different sizes and operating structures, manufacturers of vehicles and chargers, national associations, standards organizations, Tribes, fleet managers, consumer advocates, charging network operators, community-based organizations, utility regulators, consultants, vendors, labor, and environmental justice organizations. This document focuses on the future of electric on-road U.S. transportation, specifically the integration of light-duty vehicles (LDV) and medium- and heavy-duty vehicles (MHDV) and their charging infrastructure with the electric grid. However, many of the insights here may apply to electrifying other transportation modes, as well as other distributed energy resources (DER).

EVGrid Assist initiative, EV-integrated future, el↗

Grid Architecture 2

The report describes work done on Grid Architecture under the auspices of the Department of Electricity Office of Electricity Delivery and Reliability in 2015. As described in the first Grid Architecture report, the primary purpose of this work is to provide stakeholder insight about grid issues so as to enable superior decision making on their part. Doing this requires the creation of various work products, including oft-times complex diagrams, analyses, and explanations. This report provides architectural insights into several important grid topics and also describes work done to advance the science of Grid Architecture as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

grid-forming↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

controller hardware-in-the-loop↗

Rapidly Viable Sustained Grid

Rapid recovery of power flow, possibly after a blackout, is a crucial need arising in scenarios that are increasingly becoming more frequent; here, solutions for rapid viability of power while the grid is being restored are urgently needed to keep critical infrastructure (CI) online. Increasingly, after the initial recovery phase, sustenance of reliable power requires assistive services to the grid for long periods of time. Even though the need is urgent, there is only sparse effort present toward a comprehensive framework/strategy for making power rapidly viable with an emphasis on sustained grid ancillary services; which is the focus of this proposal. The proposed concept envisions four phases. In the first phase, when a large portion of power is disrupted (see Figure 1(a)), emphasis is on bringing CI online with the objective of maximizing the time horizon of power viability using resources available at the CI. In the second phase (Figure 1(b)), neighborhood resources are tightly coordinated that forms the CI’s central-core (CC) to provide guaranteed viability of CI over a longer horizon. In the third phase, self-organizing power networks are expanded in a distributed layer supporting the central-core (Figure 1(c)). In the fourth phase, separate CI-networks coalesce and are controlled in a coordinated fashion to provide grid ancillary services (AS), such as primary frequency control and enhancing grid resiliency. With time, system efficiencies and penetration of renewables increase, while the time-horizon of guaranteed sustenance of CI is maximized. Under proposed work, the concept will be instantiated with a focus on medical centers as CI. Comprehensive power hardware in the loop strategies and emulated field tests will guide and validate devised solutions. A strong T2M effort to commercialize resulting technology is outlined. The proposed technology will be transformative for the grid. It will fundamentally change the way large contingencies are managed where power systems and critical infrastructure transition from being fragile to being robust using intelligent, self-organizing control for coordinating resources, enhanced resiliency and use of sustainable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Predictive Scheduling for Electric Vehicles Considering Uncertainty of Load and User Behaviors

Un-coordinated Electric Vehicle (EV) charging can create unexpected load in local distribution grid, which may degrade the power quality and system reliability. The uncertainty of EV load, user behaviors and other baseload in distribution grid, is one of challenges that impedes optimal control for EV charging problem. Previous researches did not fully solve this problem due to lack of real-world EV charging data and proper stochastic model to describe these behaviors. In this paper, we propose a new predictive EV scheduling algorithm (PESA) inspired by Model Predictive Control (MPC), which includes a dynamic load estimation module and a predictive optimization module. The user-related EV load and base load are dynamically estimated based on the historical data. At each time interval, the predictive optimization program will be computed for optimal schedules given the estimated parameters. Only the first element from the algorithm outputs will be implemented according to MPC paradigm. Current-multiplexing function in each Electric Vehicle Supply Equipment (EVSE) is considered and accordingly a virtual load is modeled to handle the uncertainties of future EV energy demands. This system is validated by the real-world EV charging data collected on UCLA campus and the experimental results indicate that our proposed model not only reduces load variation up to 40% but also maintains a high level of robustness. Finally, IEC 61850 standard is utilized to standardize the data models involved, which brings significance to more reliable and large-scale implementation.

Wang, Bin↗

Grid Capacity – What is it, what determines it, does one number work, and how does it relate to electric vehicles?

Grid capacity is effectively how much power the system can reliably deliver, whether that is to serve loads (load service capacity) or accept generation (hosting capacity). Grid capacity can also mean different things at different scales. On the whole power system, grid capacity may be the maximum amount of power generation available. For a specific region, grid capacity may be limited by how much power the transmission and distribution lines can safely carry to that region. At the feeder level, it may be how much photovoltaic generation can be included before reliability or operations are impacted. At the end-use or residential level, grid capacity may be the size of the service breaker for that house.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomembranes for Pumped Storage Hydro

Energy storage is fundamental to ensuring the reliability, stability, and resilience of the grid, essential for meeting the energy demands now and in the future. Pumped storage stands out as a proven energy storage solution. There are 43 pumped-storage plants operating in the USA today, and they offer unparalleled scalability, rapid-response capabilities, and long-term reliability at a competitive cost. With a history of successful operation spanning decades, and approximately 60 sites proposed at various stages of permitting and development, this technology is a critical component for the US energy sector. However, its development involves some complex engineering and regulatory challenges.

13 HYDRO ENERGY↗

Cyber–Physical System Security of Distribution Systems

The Information and Communications Technology (ICT) for control and monitoring of power systems is a layer on top of the physical power system infrastructure. The cyber system and physical power system components form a tightly coupled Cyber–Physical System (CPS). Sources of vulnerabilities arise from the computing and communication systems of the cyber–power grid. Cyber intrusions targeting the power grid are serious threats to the reliability of electricity supply that is critical to society and the economy. In a typical Information Technology environment, numerous attack scenarios have shown how unauthorized users can access and manipulate protected information from a network domain. The need for cyber security has led to industry standards that power grids must meet to ensure that the monitoring, operation, and control functions are not disrupted by cyber intrusions. Cyber security technologies such as encryption and authentication have been deployed on the CPS. Intrusion or anomaly detection and mitigation tools developed for power grids are emerging. Furthermore, this survey paper provides the basic concepts of cyber vulnerabilities of distribution systems and CPS security. The important ICT subjects for distribution systems covered in this paper include Supervisory Control And Data Acquisition, Distributed Energy Resources, including renewable energy and smart meters.

97 MATHEMATICS AND COMPUTING↗

A Framework for Testing Automated Detection, Diagnosis, and Remediation Systems on the Smart Grid

America's electrical grid is currently undergoing a multi-billion dollar modernization effort aimed at producing a highly reliable critical national infrastructure for power - a Smart Grid. While the goals for the Smart Grid include upgrades to accommodate large quantities of clean, but transient, renewable energy and upgrades to provide customers with real-time pricing information, perhaps the most important objective is to create an electrical grid with a greatly increased robustness.

autonomous detection, diagnosis, and remediation (↗

Robust and resilient coordination of feeders with uncertain distributed energy resources: from real-time control to long-term planning

To enable flexible demand and ensure reliable and economical operation of distribution systems, we present a novel hierarchical scheme that actively coordinates responsive behind-the-meter grid resources, including distributed energy resources (DERs), to reliably manage each unbalanced distribution feeder and exploits the available flexibility to economically optimize the entire network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

14 SOLAR ENERGY↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-based Inverters

Grid-forming inverters rely upon an internal reference to regulate the grid 's voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller's clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller's clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗