Search NASA⌕ Search

SEARCH · Search NASA

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from a medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

Technology Advancement and Insertion into Operating Nuclear Facilities

Key challenges in the NNSA modernization effort are centered around the selection of new processing / production technologies to deploy in existing, operating, and oftentimes, aging nuclear facilities. New uranium processing technologies may offer significant improvements in worker and environmental safety, material control and accountability, and production efficiencies, but adaptation of these technologies into existing facilities presents unique (and usually, difficult) engineering solutions for each new technology. This presentation discusses approaches utilized at Y-12 to mature and demonstrate new processing and production technologies for deployment into nuclear facilities. The technology advancement lifecycle (from concept to deployment) of uranium electrorefining technologies will be reviewed, as a prototypical example, to describe steps and approaches utilized at Y-12 (and NNSA Sites) to (i) mature technologies and manufacturing strategies, (ii) establish testbed capabilities for full-scale process demonstrations, and (iii) reduce risks associated with operational disruptions when commissioning new uranium processing technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Layered hydroxides as anion insertion materials

Further described herein are extensions to the basic concept of LHs as electrode materials, include both new materials for use with LHs and higher order poly-layer hydroxides (PLHs) as well as methods for synthesizing improved LH material such as with conductive supports or through the use of cross-linking. Finally, also described herein are embodiments enabling the use of LHs as flow electrodes as well as the use of 2-d LH materials for surface redox reactions.

Young, Matthias J.↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

SU-E-J-103: Propagation of Rectum and Bladder Contours for Tandem and Ring (T&R) HDR Treatment Using Deformable Image Registration

Purpose: To investigate the feasibility of using DIR to propagate the manually contoured rectum and bladder from the 1st insertion to the new CT images on subsequent insertions and evaluate the segmentation performance. Methods: Ten cervical cancer patients, who were treated by T&R brachytherapy in 3–4 insertions, were retrospectively collected. In each insertion, rectum and bladder were manually delineated on the planning CT by a physicist and verified by a radiation oncologist. Using VelocityAI (Velocity Medical Solutions, Atlanta, GA), a rigid registration was firstly employed to match the bony structures between the first insertion and each of the following insertions, then a multi-pass B-spine DIR was carried out to further map the sub volume that encompasses rectum and bladder. The resultant deformation fields propagated contours, and dice similarity coefficient (DSC) was used to quantitatively evaluate the agreement between the propagated contours and the manually-delineated organs. For the 3rd insertion, we also evaluated if the segmentation performance could be improved by propagating the contours from the most recent insertion, i.e., the 2nd insertion. Results: On average, the contour propagation took about 1 minute. The average and standard deviation of DSC over all insertions and patients was 0.67±0.10 (range: 0.44–0.81) for rectum, and 0.78±0.07 (range: 0.63–0.87) for bladder. For the 3rd insertion, propagating contours from the 2nd insertion could improve the segmentation performance in terms of DSC from 0.63±0.10 to 0.72±0.08 for rectum, and from 0.77±0.07 to 0.79±0.06 for bladder. A Wilcoxon signed rank test indicated that the improvement was statistically significant for rectum (p = 0.004). Conclusion: The preliminary results demonstrate that deformable image registration could efficiently and accurately propagate rectum and bladder contours between CT images in different T&R brachytherapy fractions. We are incorporating the propagated contours into our learning-based method to further segment these organs.

60 APPLIED LIFE SCIENCES↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rechargeable Aluminum-Ion Batteries Based on an Open-Tunnel Framework

Rechargeable batteries based on an abundant metal such as aluminum with a three-electron transfer per atom are promising for large-scale electrochemical energy storage. Aluminum can be handled in air, thus offering superior safety, easy fabrication, and low cost. But, the development of Al-ion batteries has been challenging due to the difficulties in identifying suitable cathode materials. This study presents the use of a highly open framework Mo 2.5 + y VO 9 + z as a cathode for Al-ion batteries. The open-tunnel oxide allows a facile diffusion of the guest species and provides sufficient redox centers to help redistribute the charge within the local host lattice during the multivalent-ion insertion, thus leading to good rate capability with a specific capacity among the highest reported in the literature for Al-based batteries. Our study also presents the use of Mo 2.5 + y VO 9 + z as a model host to develop a novel ultrafast technique for chemical insertion of Al ions into host structures. The microwave-assisted method employing diethylene glycol and aluminum diacetate (Al(OH)(C 2 H 3 O 2 ) 2 ) can be performed in air in as little as 30 min, which is far superior to the traditional chemical insertion techniques involving moisture-sensitive organometallic reagents. The Al-inserted Al x Mo 2.5 + y VO 9 + z obtained by the microwave-assisted chemical insertion can be used in Al-based rechargeable batteries.

25 ENERGY STORAGE↗