Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Results of heating mode performance tests of a solar-assisted heat pump

The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

Jones, C. B.↗

Preparation of anti-adhesion surfaces on aluminium substrates of rubber plastic moulds using a coupling method of liquid plasma and electrochemical machining

Hard anti-adhesion surfaces, with low roughness and wear resistance, on aluminium substrates of rubber plastic moulds were fabricated via a new coupling method of liquid plasma and electrochemical machining. With the aid of liquid plasma thermal polishing and electrochemical anodic dissolution, micro/nano-scale binary structures were prepared as the base of the anti-adhesion surfaces. The anti-adhesion behaviours of the resulting aluminium surfaces were analysed by a surface roughness measuring instrument, a scanning electron microscope (SEM), a Fourier-transform infrared spectrophotometer (FTIR), an X-ray diffractometer (XRD), an optical contact angle meter, a digital Vickers micro-hardness (Hv) tester, and electronic universal testing. The results show that, after the liquid plasma and electrochemical machining, micro/nano-scale binary structures composed of micro-scale pits and nano-scale elongated boss structures were present on the sample surfaces. As a result, the anti-adhesion surfaces fabricated by the above coupling method have good anti-adhesion properties, better wear resistance and lower roughness.

36 MATERIALS SCIENCE↗

Building Extraction at Scale Using Convolutional Neural Network: Mapping of the United States

Establishing up-to-date large scale building maps is essential to understand the urban dynamics, such as estimating population, urban planning, and many other applications. Although many computer vision tasks have been successfully carried out with deep convolutional neural networks, there is a growing need to understand their large scale impact on building mapping with remote sensing imagery. In this paper, taking advantage of the scalability of convolutional neural networks (CNNs) and using only few areas with the abundance of building footprints, for the first time we conduct a comparative analysis of four state-of-the-art CNNs for extracting building footprints across the entire continental United States. The four CNN architectures namely: Branch-out CNN, fully convolutional network (FCN), conditional random field as recurrent neural network (CRFasRNN), and SegNet, support semantic pixelwise labeling and focus on capturing textural information at multiscale. We use 1-meter resolution aerial images from National Agriculture Imagery Program as the test-bed, and compare the extraction results across the four methods. In addition, we propose to combine signed-distance labels with SegNet, the preferred CNN architecture identified by our extensive evaluations, to advance building extraction results to instance level. We further demonstrate the usefulness of fusing additional near IR information into the building extraction framework. Large scale experimental evaluations are conducted and reported using metrics that include: Precision, recall rate, intersection over union, and the number of buildings extracted. With the improved CNN model and no requirement of further postprocessing, we have generated building maps for the United States with an average processing time less than one minute for an area of size &#x223C;<!-- ~ --> 56 km 2 . Finally, the quality of extracted buildings and processing time demonstrated that the proposed CNN based framework fits the need of building extraction at scale.

97 MATHEMATICS AND COMPUTING↗

Precision control system for engine fuel

System controls two or more pneumatically operated metering valves from common pneumatic source without interaction between valve controls. Unit affords independent metering of liquid from single source to two concurrent applications. Calibration and testing demonstrate complete absence of interaction between valves and corresponding flow rates.

Hawkins, D. E.↗

Surface atmospheric extremes (Launch and transportation areas)

The effects of extreme values of surface and low altitude atmospheric parameters on space vehicle design, tests, and operations are discussed. Atmospheric extremes from the surface to 150 meters for geographic locations of interest to NASA are given. Thermal parameters (temperature and solar radiation), humidity, pressure, and atmospheric electricity (lighting and static) are presented. Weather charts and tables are included.

Source record↗

Inlet total pressure loss due to acoustic wall treatment

The effect of diffuser wall acoustic treatment on inlet total pressure loss was experimentally determined. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14 percent the total pressure loss was 21 percent greater than that for an untreated inlet.

Miller, B. A.↗

Thermal performance of a modularized replaceable multilayer insulation system for a cryogenic stage

A rugged modularized MLI system for a 2.23-meter-diameter (87.6-in.-diam) liquid hydrogen tank was designed, fabricated, and tested under simulated near-earth and deep-space environments. The two blankets of the system were each composed of 17 double-aluminized Mylar radiation shields separated by silk net. The unit area weight of the installed system was 1.54 kg/sqm (0.32 lb/sq ft). The overall average heat transferred into the insulated tank was 22.7 and 0.98 watts (77.4 and 3.3 Btu/hr) during simulated near-earth and deep-space testing, respectively. The near-earth result was only 2.6 times that predicted for an undisturbed insulation system (i.e., no seams or penetrations). Tests indicate that this insulation concept could be useful for a cryogenic space tug or orbit transfer vehicle application.

Knoll, R. H.↗

Inlet total pressure loss due to acoustic wall treatment

Experimental determination of the effect of diffuser wall acoustic treatment on inlet total pressure loss. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14% the total pressure loss was 21% greater than that for an untreated inlet. The penalty resulting from treatment increased for average throat Mach numbers above approximately .7 where local regions of sonic or supersonic surface flow were encountered. Pressure loss over the treatment was not affected by the presence of noise.

Miller, B. A.↗

A method of calibrating wind velocity sensors with a modified gas flow calibrator

A procedure was described for calibrating air velocity sensors in the exhaust flow of a gas flow calibrator. The average velocity in the test section located at the calibrator exhaust was verified from the mass flow rate accurately measured by the calibrator's precision sonic nozzles. Air at elevated pressures flowed through a series of screens, diameter changes, and flow straighteners, resulting in a smooth flow through the open test section. The modified system generated air velocities of 2 to 90 meters per second with an uncertainty of about two percent for speeds below 15 meters per second and four percent for the higher speeds. Wind tunnel data correlated well with that taken in the flow calibrator.

Stump, H. P.↗

Lagrangian drifter design for the determination of surface currents by remote sensing

In estuaries, the interaction of wind, tidal current, and mixing of fresh and saline water produces a variable depth profile of current, with foam lines and convergence zones between water types. Careful measurement of surface currents via Lagrangian drifters requires a drifter design appropriate to both the depth of current to be measured and the tide and wind conditions of interest. The use of remote sensing to track drifters contributes additional constraints on drifter design. Several designs of biodegradable drifters which emit uranine dye plumes, resolvable in aerial imagery to 1:60,000 scale, were tested for wind drag in field conditions against data from calibrated current meters. A 20 cm-vaned wooden drifter and a window shade drifter set to 1.5 m depth had negligible wind drag in winds to 8 m/sec. Prediction of oil slick trajectories using surface current data and a wind factor should be approached cautiously, as surface current data may be wind-contaminated, while the usual 3.5% wind factor is appropriate only for currents measured at depth.

Gordon, H. H.↗

Hoop/column antenna technology development summary

The Langley Research program for development of hoop/column antenna technology was redirected and includes the fabrication and test of models such as the 4 gore segment of a 50 meter antenna and the 15 meter diameter fully deployable antenna. Significant results were obtained in the point design that includes a quad aperture reflector system for multiple beam applications.

Campbell, T. G.↗

Application of laser anemometry to cryogenic wind tunnels

The installation and tests conducted with the laser Doppler and transit anemometer in the 0.3-Meter Transonic Cryogenic Tunnel are described. Using residual particulates in the flow field, a series of free stream velocity measurements were conducted which agreed to within 1-percent of predicted values for a range of Mach numbers, 0.2 to 0.85, and temperatures, 100 to 250 K. Measurements about a shock wave provided an estimate of scattering particulate size of 4 microns or less. The particle concentration is approximately 3 x 10 to the 5th to 1.6 x 10 to the 6th/cu m. Necessary isolation of the plenum wall windows from ambient air with slightly positive pressure of dry nitrogen gas to prevent condensation on the window surface was achieved. This was accomplished through the use of large enclosures fixed to the tunnel wall. A second method used an additional sheet of thin plate glass to create the dry gas pocket next to the plenum window. The installation of a laser anemometer in the National Transonic Facility is examined. The laser transit anemometer has been tentatively selected for the initial entry because of its compact laser-optics package.

Hunter, W. W., Jr.↗

The Large Area Pulsed Solar Simulator (LAPSS)

A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.

Mueller, R. L.↗

Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

radar↗

Development of a Coherent Doppler Lidar for Precision Maneuvering and Landing of Space Vehicles

A coherent Doppler lidar has been developed to address NASA’s need for a high-performance, compact, and cost-effective velocity and altitude sensor onboard its landing vehicles. Future robotic and manned missions to planetary bodies require precise ground-relative velocity vector and altitude data to execute complex descent maneuvers and safe, soft landing at a pre-designated site. This lidar sensor, referred to as a Navigation Doppler Lidar, meets the required performance of landing missions while complying with vehicle size, mass, and power constraints. Operating from over five kilometers altitude, the lidar obtains velocity and range precision measurements with 2 cm/sec and 2 meters, respectively, dominated by the vehicle motion. After a series of flight tests onboard helicopters and rocket-powered free-flyer vehicles, the Navigation Doppler Lidar is now being ruggedized for future missions to various destinations in the solar system.

Amzaherdian, Farzin↗

Validation of Simplified Load Equations through Loads Measurement and Modeling of a Small Horizontal-Axis Wind Turbine Tower; NREL (National Renewable Energy Laboratory)

As part of an ongoing effort to improve the modeling and prediction of small wind turbine dynamics, NREL tested a small horizontal axis wind turbine in the field at the National Wind Technology Center (NWTC). The test turbine was a 2.1-kW downwind machine mounted on an 18-meter multi-section fiberglass composite tower. The tower was instrumented and monitored for approximately 6 months. The collected data were analyzed to assess the turbine and tower loads and further validate the simplified loads equations from the International Electrotechnical Commission (IEC) 61400-2 design standards. Field-measured loads were also compared to the output of an aeroelastic model of the turbine. Ultimate loads at the tower base were assessed using both the simplified design equations and the aeroelastic model output. The simplified design equations in IEC 61400-2 do not accurately model fatigue loads. In this project, we compared fatigue loads as measured in the field, as predicted by the aeroelastic model, and as calculated using the simplified design equations.

17 WIND ENERGY↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DISTRIBUTION TRANSFORMER ASSET MONITORING ON THE GRID EDGE USING SMART SENSOR DATA

As new loads such as rooftop photovoltaics, electric vehicles and other distributed energy resources become commonplace on the distribution grid, the stress on already aging assets begins to escalate. This increased loading and changing dynamics can exacerbate failure rates. While traditional monitoring efforts focus on transmission and generation assets, utilities are now beginning to pay close attention to distribution assets in order to increase reliability indices and reduce cost from unexpected outages. This research develops low-cost and scalable methods to monitoring the health of a critical distribution grid asset: the service transformer. Existing methods in literature are either invasive and thus difficult to implement or require the device to be tested offline in an expensive lab setting. Data from the ubiquitous smart meter as well as a novel Bluetooth based transformer monitor are leveraged to automatically notify the utility of deteriorating or damaged transformers. Voltage, temperature, and vibration are some of the signals measured and analyzed by the proposed algorithms to predict transformer failures. Furthermore, these algorithms are designed to keep the implementation and processing costs low by taking advantage of edge computing where possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗