Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

A study of the short- to long-phantom dose ratios for CT scanning without table translation

Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-beam Phased Array Antennas

Many of NASA's future missions require multiple accesses to work together as a single system. To accomplish these missions, multi-beam phased array antennas are required to communicate between satellites flying in fixed formation. In this paper, a comparison of different multi-beam systems will be given followed by detailed discussions of the lens array architecture and test results.

Lee, R. Q.↗

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of Multiple Volume Reflection of Ultrarelativistic Protons by a Sequence of Several Bent Silicon Crystals

The interactions of 400 GeV protons with different sequences of bent silicon crystals have been investigated at the H8 beam line of the CERN Super Proton Synchrotron. The multiple volume reflection of the proton beam has been studied in detail on a five-crystal reflector measuring an angular beam deflection {theta}=52.96{+-}0.14 {mu}rad. The efficiency was found larger than 80% for an angular acceptance at the reflector entrance of 70 {mu}rad, with a maximal efficiency value of {epsilon}=0.90{+-}0.01{+-}0.03.

43 PARTICLE ACCELERATORS↗

Large area direct-write focused ion-beam lithography with dual-beam microscope.

The authors have investigated the performance of focused ion-beam (FIB) direct-write lithography for large area (multiple write-field) patterning in an FEI Nova Nanolab 600 dual-beam microscope. Their system is configured with a 100 nm resolution X-Y stage and a RAITH ELPHY LITHOGRAPHY control interface, with its own integrated 16 bit DAC pattern generator and software. Key issues with regard to configuration, process parameters, and procedures have been addressed. Characterization of stitching errors, pattern repeatability, and drift were performed. Offset lithography (multiple exposures with offset write fields) and in-field registration marks were evaluated for correcting stitching errors, and a test microfluidic device covering an area of 1 x 1.4 mm{sup 2} was successfully fabricated. The authors found that by using a combination of offset lithography and in-field registration mark correction methods, the stitching errors can be kept well below 100 nm. They also found that due to higher beam deflection speed provided by the electrostatic scanning in FIB systems versus the wide-spread electron-beam systems with electromagnetic scanning, FIB lithography can be just as fast as electron-beam lithography for typical mill depths down to about 200-500 nm (material dependent). This opens the door for a large suite of applications for materials where pattern transfer is difficult or impossible by reactive methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-A-207-00: In Memoriam of Jacques Ovadia - Reinvigorating Scientific Excellence: Electron Beam Therapy - Past, Present and Future

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

WE-A-207-01: Memorial Lecturer

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

Multibeam field emission x-ray system with half-scan reconstruction algorithm

Purpose: In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. Methods: The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a corresponding detector segment, and a sample rotation stage. The collimator is placed between the source and the object to restrict the x-ray radiations through the target object only. In this design, all the x-ray beams are activated simultaneously to provide multiple projection views of the object. The detector is virtually segmented and synchronized with the x-ray exposure and the physiological signals when gating is involved. The transmitted x-ray intensity from each beam is collected by the corresponding segment on the detector. After each exposure, the object is rotated by a step angle until sufficient data set is collected. The half-scan reconstruction formula for MBFEX system is derived from the conventional filtered backprojection algorithm. To demonstrate the advantages of the system and method in reducing motion artifacts, the authors performed simulations with both standard and dynamic Shepp-Logan phantoms. Results: The numerical results indicate that the proposed multibeam system and the associated half-scan algorithm can effectively reduce the scanning time and improve the image quality for a time-varying object. Conclusions: The MBFEX technique offers an opportunity for the innovation of multisource imaging system.

60 APPLIED LIFE SCIENCES↗

Channeling through Bent Crystals

Bent crystals have demonstrated potential for use in beam collimation. A process called channeling is when accelerated particle beams are trapped by the nuclear potentials in the atomic planes within a crystal lattice. If the crystal is bent then the particles can follow the bending angle of the crystal. There are several different effects that are observed when particles travel through a bent crystal including dechanneling, volume capture, volume reflection and channeling. With a crystal placed at the edge of a particle beam, part of the fringe of the beam can be deflected away towards a detector or beam dump, thus helping collimate the beam. There is currently FORTRAN code by Igor Yazynin that has been used to model the passage of particles through a bent crystal. Using this code, the effects mentioned were explored for beam energy that would be seen at the Facility for Advanced Accelerator Experimental Tests (FACET) at a range of crystal orientations with respect to the incoming beam. After propagating 5 meters in vacuum space past the crystal the channeled particles were observed to separate from most of the beam with some noise due to dechanneled particles. Progressively smaller bending radii, with corresponding shorter crystal lengths, were compared and it was seen that multiple scattering decreases with the length of the crystal therefore allowing for cleaner detection of the channeled particles. The input beam was then modified and only a portion of the beam sent through the crystal. With the majority of the beam not affected by the crystal, most particles were not deflected and after propagation the channeled particles were seen to be deflected approximately 5mm. After a portion of the beam travels through the crystal, the entire beam was then sent through a quadrupole magnet, which increased the separation of the channeled particles from the remainder of the beam to a distance of around 20mm. A different code, which was developed at SLAC, was used to create an angular profile plot which was compared to what was produced by Yazynin's code for a beam with no multiple scattering. The results were comparable, with volume reflection and channeling effects observed and the range of crystal orientations at which volume reflection is seen was about 1 mrad in both simulations.

43 PARTICLE ACCELERATORS↗

Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform Dose

Purpose: To describe our experiences with patient-specific quality assurance (QA) for patients with prostate cancer receiving spot scanning proton therapy (SSPT) using single-field uniform dose (SFUD). Methods and Materials: The first group of 249 patients with prostate cancer treated with SSPT using SFUD was included in this work. The scanning-beam planning target volume and number of monitor units were recorded and checked for consistency. Patient-specific dosimetric measurements were performed, including the point dose for each plan, depth doses, and two-dimensional (2D) dose distribution in the planes perpendicular to the incident beam direction for each field at multiple depths. The {gamma}-index with 3% dose or 3-mm distance agreement criteria was used to evaluate the 2D dose distributions. Results: We observed a linear relationship between the number of monitor units and scanning-beam planning target volume. The difference between the measured and calculated point doses (mean {+-} SD) was 0.0% {+-} 0.7% (range, -2.9% to 1.8%). In general, the depth doses exhibited good agreement except at the distal end of the spread-out Bragg peak. The pass rate of {gamma}-index (mean {+-} SD) for 2D dose comparison was 96.2% {+-} 2.6% (range, 90-100%). Discrepancies between the measured and calculated dose distributions primarily resulted from the limitation of the model used by the treatment planning system. Conclusions: We have established a patient-specific QA program for prostate cancer patients receiving SSPT using SFUD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ion source with a double pulse laser system

To extend an ion beam pulse of a laser ion source, multiple laser shots could be used. To check the feasibility of this idea, we tested double laser irradiations on an iron target. When the interval of the two laser shots is longer than 10 {mu}s, the obtained ion current profile was expressed as a sum of two individual expanded laser plasmas. However, if the interval is too close, a current reduction was observed. This technique can be effectively applied to low charge state ion production.

43 PARTICLE ACCELERATORS↗

An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-361: Clinical Benefit of Automatic Beam Gating Mixed with Breath Hold in Radiation Therapy of Left Breast

Purpose: To investigate the clinical and dosimetric benefits of automatic gating of left breast mixed with breath-hold technique. Methods: Two Active Breathing Control systems, ABC2.0 and ABC3.0, were used during simulation and treatment delivery. The two systems are different such that ABC2.0 is a breath-hold system without beam control capability, while ABC3.0 has capability in both breath-hold and beam gating. At simulation, each patient was scanned twice: one with free breathing (FB) and one with breath hold through ABC. Treatment plan was generated on the CT with ABC. The same plan was also recalculated on the CT with FB. These two plans were compared to assess plan quality. For treatments with ABC2.0, beams with MU > 55 were manually split into multiple subfields. All subfields were identical and shared the total MU. For treatment with ABC3.0, beam splitting was unnecessary. Instead, treatment was delivered in gating mode mixed with breath-hold technique. Treatment delivery efficiency using the two systems was compared. Results: The prescribed dose was 50.4Gy at 1.8Gy/fraction. The maximum heart dose averaged over 10 patients was 46.0±2.5Gy and 24.5±12.2Gy for treatments with FB and with ABC respectively. The corresponding heart V10 was 13.2±3.6% and 1.0±1.6% respectively. The averaged MUs were 99.8±7.5 for LMT, 99.2±9.4 for LLT. For treatment with ABC2.0, normally the original beam was split into 2 subfields. The averaged total time to delivery all beams was 4.3±0.4min for treatments with ABC2.0 and 3.3±0.6min for treatments with ABC3.0 in gating mode. Conclusion: Treatment with ABC tremendously reduced heart dose. Compared to treatments with ABC2.0, gating with ABC3.0 reduced the total treatment time by 23%. Use of ABC3.0 improved the delivery efficiency, and eliminated the possibility of mistreatments. The latter may happen with ABC2.0 where beam is not terminated when breath signal falls outside of the treatment window.

60 APPLIED LIFE SCIENCES↗

ECOFUSION: AN ELECTRON-COOLED, CELLULAR APPROACH TO HARNESSING FUSION POWER

A cellular electron-cooled storage ring system for achieving particle-beam fusion-based-energy is described. The system uses multiple electron-cooled, overlapping storage rings to enable colliding-beam fusion. Particles are continuously fed into the storage rings, and the electron cooling systems continuously correct the ion beam trajectories, compensating for various scattering events that occur in the system. This allows for large currents to be built up in the ion storage rings. The rate of fusion reactions that occur in the overlap regions between the storage rings can be increased by focusing to enable power outputs of interest for fusion-based power reactors. The system can be built with technology readily available today.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach

Rotational RapidArc (RA) and static intensity-modulated radiosurgery (IMRS) have been used for brain radiosurgery. This study compares the 2 techniques from beam delivery parameters and dosimetry aspects for multiple brain metastases. Twelve patients with 2-12 brain lesions treated with IMRS were replanned using RA. For each patient, an optimal 2-arc RA plan from several trials was chosen for comparison with IMRS. Homogeneity, conformity, and gradient indexes have been calculated. The mean dose to normal brain and maximal dose to other critical organs were evaluated. It was found that monitor unit (MU) reduction by RA is more pronounced for cases with larger number of brain lesions. The MU-ratio of RA and IMRS is reduced from 104% to 39% when lesions increase from 2 to 12. The dose homogeneities are comparable in both techniques and the conformity and gradient indexes and critical organ doses are higher in RA. Treatment time is greatly reduced by RA in intracranial radiosurgery, because RA uses fewer MUs, fewer beams, and fewer couch angles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-372: Surface and Peripheral Dose in Compensator-Based FFF Beam IMRT

Purpose: Flattening filter free (FFF) beams produce higher dose rates. Combined with compensator IMRT techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or compensator-based IMRT. This ‘snap shot’ IMRT delivery is beneficial to patients for tumor motion management. Due to softer energy, surface doses in FFF beam treatment are usually higher than those from flattened beams. Because of less scattering due to no flattening filter, peripheral doses are usually lower in FFF beam treatment. However, in compensator-based IMRT using FFF beams, the compensator is in the beam pathway. Does it introduce beam hardening effects and scattering such that the surface dose is lower and peripheral dose is higher compared to FFF beam MLC-based IMRT? Methods: This study applied Monte Carlo techniques to investigate the surface and peripheral doses in compensator-based IMRT using FFF beams and compared it to the MLC-based IMRT using FFF beams and flattened beams. Besides various thicknesses of copper slabs to simulate various thicknesses of compensators, a simple cone-shaped compensator was simulated to mimic a clinical application. The dose distribution in water phantom by the cone-shaped compensator was then simulated by multiple MLC defined FFF and flattened beams with various openings. After normalized to Dmax, the surface and peripheral dose was compared between the FFF beam compensator-based IMRT and FFF/flattened beam MLC-based IMRT. Results: The surface dose at the central 0.5mm depth was close between the compensator and 6FFF MLC dose distributions, and about 8% (of Dmax) higher than the flattened 6MV MLC dose. At 8cm off axis at dmax, the peripheral dose between the 6FFF and flattened 6MV MLC demonstrated similar doses, while the compensator dose was about 1% higher. Conclusion: Compensator does not reduce the surface doses but slightly increases the peripheral doses due to scatter inside compensator.

60 APPLIED LIFE SCIENCES↗