Meeting the Grand Challenge of Protecting Astronauts Health: Electrostatic Active Space Radiation Shielding for Deep Space Missions

This report describes the research completed during 2011 for the NASA Innovative Advanced Concepts (NIAC) project. The research is motivated by the desire to safely send humans in deep space missions and to keep radiation exposures within permitted limits. To this end current material shielding, developed for low earth orbit missions, is not a viable option due to payload and cost penalties. The active radiation shielding is the path forward for such missions. To achieve active space radiation shielding innovative large lightweight gossamer space structures are used. The goal is to deflect enough positive ions without attracting negatively charged plasma and to investigate if a charged Gossamer structure can perform charge deflections without significant structural instabilities occurring. In this study different innovative configurations are explored to design an optimum active shielding. In addition, to establish technological feasibility experiments are performed with up to 10kV of membrane charging, and an electron flux source with up to 5keV of energy and 5mA of current. While these charge flux energy levels are much less than those encountered in space, the fundamental coupled interaction of charged Gossamer structures with the ambient charge flux can be experimentally investigated. Of interest are, will the EIMS remain inflated during the charge deflections, and are there visible charge flux interactions. Aluminum coated Mylar membrane prototype structures are created to test their inflation capability using electrostatic charging. To simulate the charge flux, a 5keV electron emitter is utilized. The remaining charge flux at the end of the test chamber is measured with a Faraday cup mounted on a movable boom. A range of experiments with this electron emitter and detector were performed within a 30x60cm vacuum chamber with vacuum environment capability of 10-7 Torr. Experiments are performed with the charge flux aimed at the electrostatically inflated membrane structure (EIMS) in both charged and uncharged configurations. The amount of charge shielding behind and around the EIMS was studied for different combinations of membrane structure voltages and electron energies. Both passive and active shielding were observed, with active shielding capable of deflecting nearly all incoming electrons. The pattern of charge distribution around the structure was studied as well as the stability of the structures in the charge flow. The charge deflection experiments illustrate that the EIMS remain inflated during charge deflection, but will experience small amplitude oscillations. Investigations were performed to determine a potential cause of the vibrations. It is postulated these vibrations are due to the charge flux causing local membrane charge distribution changes. As the membrane structure inflation pressure is changed, the shape responds, and causes the observed sustained vibration. Having identified this phenomenon is important when considering electrostatically inflated membrane structures (EIMS) in a space environment. Additionally, this project included a study of membrane material impacts, specifically the impact of membrane thickness. Extremely thin materials presented new challenges with vacuum preparation techniques and rapid charging. The thinner and lighter membrane materials were successfully inflated using electrostatic forces in a vacuum chamber. However, care must be taken when varying the potentials of such lighter structures as the currents can cause local heating and melting of the very thin membranes. Lastly, a preliminary analysis is performed to study rough order of magnitude power requirements for using EIMS for radiation shielding. The EIMS power requirement becomes increasingly more challenging as the spacecraft voltage is increased. As a result, the emphasis is on the deflection of charges away from the spacecraft rather than totally stopping them. This significantly alleviates the initial power requirements. With modest technological development(s) active shielding is emerging to be a viable option.

Radiation↗

Hall interchange instability as a seed for helical magneto-Rayleigh–Taylor instabilities in magnetized liner inertial fusion Z-Pinches scaled from Z-Machine parameters to a next generation pulsed power facility

Magnetized liner inertial fusion (MagLIF) is a magneto-inertial-fusion concept that is studied on the 20-MA, 100-ns rise time Z Pulsed Power Facility at Sandia National Laboratories. Given the relative success of the platform, there is a wide interest in studying the scaled performance of this concept at a next-generation pulsed-power facility that may produce peak currents upward of 60 MA. An important aspect that requires more research is the instability dynamics of the imploding MagLIF liner, specifically how instabilities are initially seeded. It has been shown in magnetized 1-MA thin-foil liner Z-pinch implosion simulations that a Hall interchange instability (HII) effect can provide an independent seeding mechanism for helical magneto-Rayleigh–Taylor instabilities. Here in this paper, we explore this instability at higher peak currents for MagLIF using 2D discontinuous Galerkin PERSEUS simulations, an extended magneto-hydrodynamics code, which includes Hall physics. Our simulations of scaled MagLIF loads show that the growth rate of the HII is invariant to the peak current, suggesting that studies at 20-MA are directly relevant to 60-MA class machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmological dynamics of a Dirac-Born-Infeld field

We analyze the dynamics of a Dirac-Born-Infeld (DBI) field in a cosmological setup which includes a perfect fluid. Introducing convenient dynamical variables, we show that the evolution equations form an autonomous system when the potential and the brane tension of the DBI field are arbitrary power law or exponential functions of the DBI field. In particular we find scaling solutions can exist when powers of the field in the potential and warp factor satisfy specific relations. A new class of fixed-point solutions are obtained corresponding to points which initially appear singular in the evolution equations, but on closer inspection are actually well defined. In all cases, we perform a phase-space analysis and obtain the late-time attractor structure of the system. Of particular note when considering cosmological perturbations in DBI inflation is a fixed-point solution where the Lorentz factor is a finite large constant and the equation of state parameter of the DBI field is w=-1. Since in this case the speed of sound c{sub s} becomes constant, the solution can be thought to serve as a good background to perturb about.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainties in Local Intense Precipitation Flood Modeling

In the Task 1 report for the U.S. Nuclear Regulatory Commission (NRC) funded Local Intense Precipitation (LIP) Probabilistic Flood Hazard Assessment (PFHA) Pilot Study, the Pacific Northwest National Laboratory (PNNL) reviewed hydrologic and hydraulic modeling approaches for estimation of LIP flooding and their implementation in readily available simulation software packages (Prasad and Yuan 2020). NRC’s interest is in developing guidance for performing LIP PFHA at nuclear power plant (NPP) sites. This report describes the work done under Task 2 of the study that focused on describing uncertainties associated with LIP flood modeling. Two main types of uncertainties exist in LIP flood modeling: (1) aleatory uncertainties that arise from the inherent natural variability of the hydrometeorological system and (2) epistemic uncertainties that arise from the analysts’ incomplete knowledge of the hydrometeorological and site configuration. Principal sources for aleatory variability in LIP flood simulations at NPP sites include precipitation (i.e., magnitude, duration, and temporal distribution of LIP events), initial conditions (e.g., soil moisture content, stormwater drainage discharge, surface storage), boundary conditions (e.g., upstream discharge, downstream water surface elevations), and long-term temporal trends (e.g., climate change). This report describes approaches used for estimating the aleatory variability in precipitation including precipitation-frequency analysis, numerical weather prediction, and stochastic weather generation. Data sources that can be used to estimate aleatory variability in initial and boundary conditions are also described. Approaches to include effects of long-term trends like those from climate change into estimation of aleatory variability are summarized. Sources of epistemic uncertainty in LIP flood simulations at NPP sites include process representation (e.g., multiple approaches to represent runoff generation, stormwater drainage, and hydraulic routing), site configurations (e.g., site layout, flow features, status of temporary flood protection, blockage of drains), model resolution, and long-term temporal trends (e.g., known/planned site alterations, land-use changes at and in the vicinity of the site). The report describes alternative process representations (methods and models), particularly those implemented in the LIP flood simulation software packages reviewed in Task 1 report, and lists the associated model parameters. Approaches for estimating model parameters when surface and subsurface water exchanges occur are also described.

42 ENGINEERING↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interface capturing simulations of bubble population effects in PWR subchannels

As the computational power of high-performance computing (HPC) facilities grows, so too does the feasibility of using first principle based simulation to study turbulent two-phase flows within complex pressurized water reactor (PWR) geometries. Direct numerical simulation (DNS), integrated with an interface capturing method, allows for the collection of high-fidelity numerical data using advanced analysis techniques. The research presented here employs the massively parallel, finite-element based, unstructured mesh code, PHASTA, to simulate a set of two-phase bubbly flows through PWR subchannel geometries including auxiliary structures (spacer grids and mixing vanes). The main objective of the presented work is to analyze bubble dynamics and turbulence interactions at varying bubble concentrations to support the development of advanced two-phase flow closure models. Turbulent two-phase flows in PWR subchannels were simulated at hydraulic Reynolds numbers of 81,000 with bubble concentrations of 3%–15% by gas volume fraction (768–3928 resolved bubbles, respectively) and compared against a 1% void fraction case (262 bubbles) that had been previously simulated. The finite element mesh utilized for the study at higher bubble concentrations was composed of 1.55 billion elements, compared to the previous study which employed 1.11 billion elements, ensuring all turbulence scales and individual bubbles within the flow are fully resolved. For each case, the resolved initial bubble size was 0.65 mm in diameter (resolved with 25 grid points across the diameter). The simulations were analyzed to find flow features such as the mean velocity profile, bubble relative velocity and the effect of the bubbles on the turbulent conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

Pitot tube↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet↗

Exfoliation Propensity of Oxide Scale in Heat Exchangers Used for Supercritical CO2 Power Cycles

Supercritical CO2 (sCO2) Brayton cycle systems offer the possibility of improved efficiency in future fossil energy power generation plants operating at temperatures of 650 C and above. As there are few data on the oxidation/corrosion behavior of structural alloys in sCO2 at these temperatures, modeling to predict the propensity for oxide exfoliation is not well developed, thus hindering materials selection for these novel cycles. The ultimate goal of this effort is to provide needed data on scale exfoliation behavior in sCO2 for confident alloy selection. To date, a model developed by ORNL and EPRI for the exfoliation of oxide scales formed on boiler tubes in high-temperature, high-pressure steam has proven useful for managing exfoliation in conventional steam plants. A major input provided by the model is the ability to predict the likelihood of scale failure and loss based on understanding of the evolution of the oxide morphologies and the conditions that result in susceptibility to exfoliation. This paper describes initial steps taken to extend the existing model for exfoliation of steam-side oxide scales to sCO2 conditions. The main differences between high-temperature, high-pressure steam and sCO2 that impact the model involve (i) significant geometrical differences in the heat exchangers, ranging from standard pressurized tubes seen typically in steam-producing boilers to designs for sCO2 that employ variously-curved thin walls to create shaped flow paths for extended heat transfer area and small channel cross-sections to promote thermal convection and support pressure loads; (ii) changed operating characteristics with sCO2 due to the differences in physical and thermal properties compared to steam; and (iii) possible modification of the scale morphologies, hence properties that influence exfoliation behavior, due to reaction with carbon species from sCO2. The numerical simulations conducted were based on an assumed sCO2 operating schedule and several generic heat exchanger channel shapes and cross-sectional areas. Implications for the evolution of stresses in the oxide scales formed on sCO2 heat exchangers, and ensuing critical oxide thicknesses for exfoliation, were derived and compared with expectations for an equivalent conventional tubular heat exchanger in a steam cycle (for a given alloy).

Sabau, Adrian S↗

Modified Lucas-Washburn theory for fluid filling in nanotubes

Ultrafast water transport in carbon nanotubes (CNTs) has drawn a great deal of attention in a number of applications, such as water desalination, power generation, and biomolecule detection. With the recent experimental advances in water filling of isolated CNTs, the Lucas-Washburn theory for capillary rise in tubes needs to be revisited for a better understanding of the physics and dynamics of water filling in CNTs. Here, the Lucas-Washburn theory is corrected for the hydrodynamic entrance effects as well as the variation of capillary pressure and hydrodynamic properties with the radius and length of CNTs. Due to the large slippage in CNTs, inclusion of the entrance effects is important particularly for the initial stages of filling where a L ∝ t scaling, as opposed to L 2 ∝ t , is observed in our molecular dynamics (MD) simulations. The corrected Lucas-Washburn theory is shown to predict the water filling dynamics in CNTs as observed in MD simulations. With the corrected theory, we achieve a better understanding of capillary rise and water filling dynamics in CNTs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Submersible Generator for Marine Hydrokinetics

A submersible generator was designed as a distinct and critical subassembly of marine hydrokinetics systems, specifically tidal and stream energy conversion. The generator is designed to work with both vertical and horizontal axis turbines. The final product is a high-pole-count, radial-flux, permanent magnet, rim mounted generator, initially rated at twenty kilowatts in a two-meter-per-second flow, and designed to leverage established and simple manufacturing processes. The generator was designed to work with a 3 meter by 7 meter Gorlov Helical Turbine or a marine hydrokinetic version of the FloDesign wind turbine. The team consisted of experienced motor/generator design engineers with cooperation from major US component suppliers (magnetics, coil winding and electrical steel laminations). Support for this effort was provided by Lucid Energy Technologies and FloDesign, Inc. The following tasks were completed: Identified the conditions and requirements for MHK generators. Defined a methodology for sizing and rating MHK systems. Selected an MHK generator topology and form factor. Completed electromechanical design of submersible generator capable of coupling to multiple turbine styles. Investigated MHK generator manufacturing requirements. Reviewed cost implications and financial viability. Completed final reporting and deliverables

13 HYDRO ENERGY↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

Modeling properties of chromospheric evaporation driven by thermal conduction fronts from reconnection shocks

Magnetic reconnection in the corona results in contracting flare loops, releasing energy into plasma heating and shocks. The hydrodynamic shocks produced in this manner drive thermal conduction fronts (TCFs) which transport energy into the chromosphere and drive upflows (evaporation) and downflows (condensation) in the cooler, denser footpoint plasma. Observations have revealed that certain properties of the transition point between evaporation and condensation (the 'flow reversal point' or FRP), such as temperature and velocity-temperature derivative at the FRP, vary between different flares. These properties may provide a diagnostic tool to determine parameters of the coronal energy release mechanism and the loop atmosphere. In this study, we develop a one-dimensional hydrodynamical flare loop model with a simplified three-region atmosphere (chromosphere/transition region/corona), with TCFs initiated by shocks introduced in the corona. We investigate the effect of two different flare loop parameters (post-shock temperature and transition region temperature ratio) on the FRP properties. We find that both of the evaporation characteristics have scaling-law relationships to the varied flare parameters, and we report the scaling exponents for our model. This provides a means of using spectroscopic observations of the chromosphere as quantitative diagnostics of flare energy release in the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Durability of Membrane Electrode Assemblies (MEAs) in PEM Fuel Cells Operated on Pure Hydrogen and Oxygen

Proton exchange membrane (PEM) fuel cells are energy sources that have the potential to replace alkaline fuel cells for space programs. Broad power ranges, high peak-to-nominal power capabilities, low maintenance costs, and the promise of increased life are the major advantages of PEM technology in comparison to alkaline technology. The probability of PEM fuel cells replacing alkaline fuel cells for space applications will increase if the promise of increased life is verified by achieving a minimum of 10,000 hours of operating life. Durability plays an important role in the process of evaluation and selection of MEAs for Teledyne s Phase I contract with the NASA Glenn Research Center entitled Proton Exchange Membrane Fuel cell (PEMFC) Power Plant Technology Development for 2nd Generation Reusable Launch Vehicles (RLVs). For this contract, MEAs that are typically used for H2/air operation were selected as potential candidates for H2/O2 PEM fuel cells because their catalysts have properties suitable for O2 operation. They were purchased from several well-established MEA manufacturers who are world leaders in the manufacturing of diverse products and have committed extensive resources in an attempt to develop and fully commercialize MEA technology. A total of twelve MEAs used in H2/air operation were initially identified from these manufacturers. Based on the manufacturers specifications, nine of these were selected for evaluation. Since 10,000 hours is almost equivalent to 14 months, it was not possible to perform continuous testing with each MEA selected during Phase I of the contract. Because of the lack of time, a screening test on each MEA was performed for 400 hours under accelerated test conditions. The major criterion for an MEA pass or fail of the screening test was the gas crossover rate. If the gas crossover rate was higher than the membrane intrinsic permeability after 400 hours of testing, it was considered that the MEA had failed the test. Three types of MEAs out of the nine total membranes failed the test. The evaluation results showed that fuel cell operating conditions (current, pressure, stoichiometric flow rates) were the parameters that influenced the durability of MEAs. In addition, the durability test results indicated that the type of membrane was also an important parameter for MEA durability. At accelerated test conditions, the MEAs with casted membranes failed during the 400 hour test. However, the MEAs prepared from the casted membrane with support as well as extruded membranes, both passed the 400h durability test at accelerated operating test conditions. As a result of the MEA accelerated durability tests, four MEAs were selected for further endurance testing. These tests are being carried out with four-cell stacks under nominal fuel cell operating conditions.

Stanic, Vesna↗

Thermal hydraulic model of the molten salt reactor experiment with the NEAMS system analysis module

System analysis codes have a long history of providing best-estimate and conservative safety analysis for both light water and advanced reactor technologies, including molten salt reactors. As interest continues to expand with advanced reactor concepts, system analysis codes will need revisions to accommodate the behavior of these technologies. Legacy system analysis codes will need to be updated to the latest numerical techniques to shorten execution time and increase the accuracy of results. One example of a modern system analysis code that already encompasses these characteristics is the System Analysis Module (SAM). One key objective of this paper was to review available information for system code modeling of the Molten Salt Reactor Experiment (MSRE) from sources in the open literature and collect the information from these open sources in one place for the first time. This supports the potential objective of developing an open specification for system code analysis for MSRE steady state and transients with and without reactor kinetics. Data from actual MSRE tests will serve as the basis for code-to-code comparison exercises, including the MSRE zero power physics tests, the fuel pump start-up and coast down tests, and the natural circulation transient. The objective is to produce a code-to-code benchmark with a standardized set of comparison problems, recognizing the limitations of the original data. To demonstrate an initial application of this objective and the usefulness of compiling this open data, two Molten Salt Reactor Experiment (MSRE)-related models were developed to evaluate SAM for liquid fueled molten salt reactors. One model was the SAM MSRE hydraulic mockup, which provided experimental data for pressure drop measurements. The second model was the complete MSRE primary loop. The MSRE primary loop model incorporated a fluoride salt fuel/coolant with heat transfer in both the core and heat exchanger. For both the hydraulic mockup and MSRE primary loop models, a holistic 1-D system description was built using open documentation, an open description that can be readily modified and applied for any system analysis code. SAM results for the pressure drop of the hydraulic mockup model were within 6% with measurements. Coolant temperatures for the primary loop model matched the expected axial change in temperature from historical calculations. Using alternative coolant properties obtained from the literature, corresponding to salts with different actinide contents, returned similar trends in core temperature profiles. A thermal hydraulic demonstration of a loss-of-flow transient showed the importance of coupling SAM thermal hydraulic analysis to neutronics. Here, this coupling is essential for simulating MSR transients with system analysis codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.