Search NASA⌕ Search

SEARCH · Search NASA

Results for “process analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Processing of electron microprobe data from the analysis of altered cementitious materials

The purpose of this paper is to present a method for processing electron microprobe data coming from the analysis of degraded cementitious materials. The application domain is that of cement matrices exposed to attack by aggressive media inducing the leaching of one or more chemical elements from the cement paste - typically attacked by neutral or acid aqueous environments. As raw data obtained from electron probe microanalysis (EPMA) come in the form of relative quantities of elements, the aim of the processing is to obtain the absolute variation of the specimen's chemical composition in the degraded zone and consequently to allow a better understanding of the degradation mechanisms by the aggressive environment under consideration. This method was designed for degraded specimens in which the porosity was not filled with resin before the EPMA. The method uses the titanium content of the cement matrix as a control, this element being stable during attack by neutral or acidic media. The method is described in detail using the example of the attack of cement pastes by a mix of several organic acids (notably acetic acid) at pH 4. The use of EPMA for sound and altered cement pastes is also validated. The application domain of the correction method is discussed.

36 MATERIALS SCIENCE↗

2009 DOE-EM LONG-TERM MONITORING TECHNICAL FORUM SUMMARY REPORT

The U. S. Department of Energy's (DOE) Office of Environmental Management (EM) has the responsibility for cleaning up 60 sites in 22 states that were associated with the legacy of the nation's nuclear weapons program and other research and development activities. These sites are unique and many of the technologies needed to successfully disposition the associated wastes have yet to be developed or would require significant re-engineering to be adapted for future EM cleanup efforts. In 2008, the DOE-EM Engineering and Technology Program (EM-22) released the Engineering and Technology Roadmap in response to Congressional direction and the need to focus on longer term activities required for the completion of the aforementioned cleanup program. One of the strategic initiatives included in the Roadmap was to enhance long term performance monitoring as defined by 'Develop and deploy cost effective long-term strategies and technologies to monitor closure sites (including soil, groundwater, and surface water) with multiple contaminants (organics, metals and radionuclides) to verify integrated long-term cleanup performance'. To support this long-term monitoring (LTM) strategic initiative, EM 22 and the Savannah River National Laboratory (SRNL) organized and held an interactive symposia, known as the 2009 DOE-EM Long-Term Monitoring Technical Forum, to define and prioritize LTM improvement strategies and products that could be realized within a 3 to 5 year investment time frame. This near-term focus on fundamental research would then be used as a foundation for development of applied programs to improve the closure and long-term performance of EM's legacy waste sites. The Technical Forum was held in Atlanta, GA on February 11-12, 2009, and attended by 57 professionals with a focus on identifying those areas of opportunity that would most effectively advance the transition of the current practices to a more effective strategy for the LTM paradigm. The meeting format encompassed three break-out sessions, which focused on needs and opportunities associated with the following LTM technical areas: (1) Performance Monitoring Tools, (2) Systems, and (3) Information Management. The specific objectives of the Technical Forum were to identify: (1) technical targets for reducing EM costs for life-cycle monitoring; (2) cost-effective approaches and tools to support the transition from active to passive remedies at EM waste sites; and (3) specific goals and objectives associated with the lifecycle monitoring initiatives outlined within the Roadmap. The first Breakout Session on LTM performance measurement tools focused on the integration and improvement of LTM performance measurement and monitoring tools that deal with parameters such as ecosystems, boundary conditions, geophysics, remote sensing, biomarkers, ecological indicators and other types of data used in LTM configurations. Although specific tools were discussed, it was recognized that the Breakout Session could not comprehensively discuss all monitoring technologies in the time provided. Attendees provided key references where other organizations have assessed monitoring tools. Three investment sectors were developed in this Breakout Session. The second Breakout Session was on LTM systems. The focus of this session was to identify new and inventive LTM systems addressing the framework for interactive parameters such as infrastructure, sensors, diagnostic features, field screening tools, state of the art characterization monitoring systems/concepts, and ecosystem approaches to site conditions and evolution. LTM systems consist of the combination of data acquisition and management efforts, data processing and analysis efforts and reporting tools. The objective of the LTM systems workgroup was to provide a vision and path towards novel and innovative LTM systems, which should be able to provide relevant, actionable information on system performance in a cost-effective manner. Two investment sectors were developed in this Breakout Session. The last Breakout Session of the Technical Forum was on LTM information management. The session focus was on the development and implementation of novel information management systems for LTM including techniques to address data issues such as: efficient management of large and diverse datasets; consistency and comparability in data management and incorporation of accurate historical information; data interpretation and information synthesis including statistical methods, modeling, and visualization; and linage of data to site management objectives and leveraging information to forge consensus among stakeholders. One investment sector was developed in this Breakout Session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

THE BOSS EMISSION-LINE LENS SURVEY (BELLS). I. A LARGE SPECTROSCOPICALLY SELECTED SAMPLE OF LENS GALAXIES AT REDSHIFT {approx}0.5

We present a catalog of 25 definite and 11 probable strong galaxy-galaxy gravitational lens systems with lens redshifts 0.4 {approx}< z {approx}< 0.7, discovered spectroscopically by the presence of higher-redshift emission lines within the Baryon Oscillation Spectroscopic Survey (BOSS) of luminous galaxies, and confirmed with high-resolution Hubble Space Telescope (HST) images of 44 candidates. Our survey extends the methodology of the Sloan Lens Advanced Camera for Surveys survey (SLACS) to higher redshift. We describe the details of the BOSS spectroscopic candidate detections, our HST ACS image processing and analysis methods, and our strong gravitational lens modeling procedure. We report BOSS spectroscopic parameters and ACS photometric parameters for all candidates, and mass-distribution parameters for the best-fit singular isothermal ellipsoid models of definite lenses. Our sample to date was selected using only the first six months of BOSS survey-quality spectroscopic data. The full five-year BOSS database should produce a sample of several hundred strong galaxy-galaxy lenses and in combination with SLACS lenses at lower redshift, strongly constrain the redshift evolution of the structure of elliptical, bulge-dominated galaxies as a function of luminosity, stellar mass, and rest-frame color, thereby providing a powerful test for competing theories of galaxy formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

Understanding the Differences in Molecular Conformation of Carbohydrate and Protein in Endosperm Tissues of Grains with Different Biodegradation Kinetics Using Advanced Synchrotron Technology

Conventional 'wet' chemical analyses rely heavily on the use of harsh chemicals and derivatization, thereby altering native seed structures leaving them unable to detect any original inherent structures within an intact tissue sample. A synchrotron is a giant particle accelerator that turns electrons into light (million times brighter than sunlight) which can be used to study the structure of materials at the molecular level. Synchrotron radiation-based Fourier transform IR microspectroscopy (SR-FTIRM) has been developed as a rapid, direct, non-destructive and bioanalytical technique. This technique, taking advantage of the brightness of synchrotron light and a small effective source size, is capable of exploring the molecular chemistry within the microstructures of a biological tissue without the destruction of inherent structures at ultraspatial resolutions within cellular dimensions. This is in contrast to traditional 'wet' chemical methods, which, during processing for analysis, often result in the destruction of the intrinsic structures of feeds. To date there has been very little application of this technique to the study of plant seed tissue in relation to nutrient utilization. The objective of this study was to use novel synchrotron radiation-based technology (SR-FTIRM) to identify the differences in the molecular chemistry and conformation of carbohydrate and protein in various plant seed endosperms within intact tissues at cellular and subcellular level from grains with different biodegradation kinetics. Barley grain (cv. Harrington) with a high rate (31.3%/h) and extent (78%), corn grain (cv. Pioneer) with a low rate (9.6%/h) and extent of (57%), and wheat grain (cv. AC Barrie) with an intermediate rate (23%/h) and extent (72%) of ruminal DM degradation were selected for evaluation. SR-FTIRM evaluations were performed at the National Synchrotron Light Source at the Brookhaven National Laboratory (Brookhaven, NY). These results suggest that SR-FTIRM plus the multivariate analyses can be used to identify spectral features associated with the molecular structure of endosperm from grains with different biodegradation kinetics, especially in relation to protein structure. The Novel synchrotron radiation-based bioanalytical technique provides a new approach for plant seed structural molecular studies at ultraspatial resolution and within intact tissue in relation to nutrient availability.

43 PARTICLE ACCELERATORS↗

Adsorptive denitrogenation of model aviation fuel using mesoporous silica in a packed bed adsorption system

This study aims to understand the effects of system process parameters such as flow rate, adsorbent particle size, and use of recycled adsorbent on denitrogenation performance of a model fuel using mesoporous silica gel. The goal is to reduce the nitrogen content of the model fuel from 1500 parts per million to single-digit ppm to meet ASTM specifications for drop-in fuels. This work was done with the intent of applying adsorptive denitrogenation to sustainable aviation fuel (SAF) product fractions produced via hydrothermal liquefaction (HTL). The adsorption performance of the silica is evaluated via packed column breakthrough data, with data generated from collecting from the column outlet and quantifying nitrogen content via gas chromatography. Select experiments use a significantly larger (2.5x column diameter and length) column to demonstrate linear scalability of the process. Thermogravimetric analysis data is collected to evaluate the effects of thermal calcination as a sorbent regeneration method. Effects of a more complex feed are also investigated using a known reference fuel with additional added nitrogen containing compounds. The results presented in this work successfully demonstrate up to 99.8 % removal of NCCs from a model fuel fraction at an original NCC concentration of approximately 1500 ppm to single-digit parts per million after treatment. We also examine calcination of sorbent materials to remove the adsorbed species to enable sorbent reuse and minimize waste generation and show that the calcined material can be reused up to 5 cycles with reduced adsorption capacity. Overall, this work indicates that adsorptive denitrogenation using silica gel is a viable solution to enable the integration of HTL-derived aviation fuels into existing fuel infrastructure.

Adsorption techniques↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Black carbon mixing state impacts on cloud microphysical properties: Effects of aerosol plume and environmental conditions

Black carbon (BC) is usually mixed with other aerosol species within individual aerosol particles. This mixture, along with the particles' size and morphology, determines the particles' optical and cloud condensation nuclei properties, and hence black carbon's climate impacts. In this study the particle-resolved aerosol model PartMC-MOSAIC was used to quantify the importance of black carbon mixing state for predicting cloud microphysical quantities. Based on a set of about 100 cloud parcel simulations a process level analysis framework was developed to attribute the response in cloud microphysical properties to changes in the underlying aerosol population ("plume effect") and the cloud parcel cooling rate ("parcel effect"). It shows that the response of cloud droplet number concentration to changes in BC emissions depends on the BC mixing state. When the aerosol population contains mainly aged BC particles an increase in BC emission results in increasing cloud droplet number concentrations ("additive effect"). In contrast, when the aerosol population contains mainly fresh BC particles they act as sinks for condensable gaseous species, resulting in a decrease in cloud droplet number concentration as BC emissions are increased ("competition effect"). Additionally, we quantified the error in cloud microphysical quantities when neglecting the information on BC mixing state, which is often done in aerosol models. Here, the errors ranged from -12% to +45% for the cloud droplet number fraction, from 0% to +1022% for the nucleation-scavenged black carbon (BC) mass fraction, from -12% to +4% for the effective radius, and from -30% to +60% for the relative dispersion.

54 ENVIRONMENTAL SCIENCES↗

Processing of Dilute Mg–Zn–Mn–Ca Alloy/Nb Multilayers by Accumulative Roll Bonding

Recent advancements in the severe plastic deformation process called accumulative roll bonding (ARB) can help to address the long-standing need for manufacturing lightweight, high-strength Mg sheet materials. However, the fabrication of Mg alloy-based laminates via ARB remains a challenge due to the intrinsically poor formability of Mg. Herein, it is shown that Mg-based composite laminates with refined layers can be fabricated via several room-temperature ARB cycles with appropriate intermediate annealing and alloy selection. The final laminates made here consist of equal volume fractions of a dilute Mg–Zn–Mn–Ca alloy phase and a pure Nb phase with fine 150 μm layer thicknesses. Deformation texture evolution in both phases within the composite is analyzed via neutron diffraction measurements taken at different stages in the process. The analysis suggests that the annealing step recrystallizes the Mg-alloy phase. It is also shown that for both phases, the stabilized deformation textures within the composite correspond to the classic stable textures of the individual constituents. Polycrystal texture modeling implies that {10–12} <-1011> extension twinning developed in the Mg alloy during rolling.

36 MATERIALS SCIENCE↗

Microstructural Passivation of Patterned Al 2 O 3 Back Contacts on CdS/CdTe Solar Cells

Abstract Patterned aluminum oxide (Al 2 O 3 ) back contact on cadmium telluride (CdTe) solar cells can effectively mitigate the loss of the majority carriers while retaining the passivation benefits for minority carriers. This study investigates the impact of the point‐contact geometry on cell performance, where the spacing of the microholes is systematically varied at a constant microhole diameter (≈16 µm). Microhole arrays are created on an evaporated Al 2 O 3 layer (≈30 nm) on CdTe using laser‐beam lithography and selective wet etching processes. Comparative analysis indicates a significant decrease in fill factor (FF) and short‐circuit current ( I SC ) when the contact fraction falls below 30%, likely due to the Al 2 O 3 barrier impeding majority carriers. Above this fraction, FF and I SC are comparable to those of baseline CdTe cells without Al 2 O 3 . Open‐circuit voltage ( V OC ) shows a gradual decrease as Al 2 O 3 coverage is reduced but exhibits a slight increase (<15 mV) when the contact fraction exceeds 30%. Cathodoluminescence (CL) characterization reveals that significantly improved radiative recombination occurs within the CdTe grain bulk with Al 2 O 3 , whereas this effect on grain boundaries is minimal. The findings imply complex local carrier dynamics in the patterned back‐contact region, closely tied to the microstructural properties of CdTe‐based solar cells.

Roy, Etee Kawna↗

Advances in interpretation of subsurface processes with time-lapse electrical imaging

Electrical geophysical methods, including electrical resistivity, time-domain induced polarization, and complex resistivity, have become commonly used to image the near subsurface. Here, we outline their utility for time-lapse imaging of hydrological, geochemical, and biogeochemical processes, focusing on new instrumentation, processing, and analysis techniques specific to monitoring. We review data collection procedures, parameters measured, and petrophysical relationships and then outline the state of the science with respect to inversion methodologies, including coupled inversion. We conclude by highlighting recent research focused on innovative applications of time-lapse imaging in hydrology, biology, ecology, and geochemistry, among other areas of interest.

COMPLEX CONDUCTIVITY↗

Density estimation via measure transport: Outlook for applications in the biological sciences

Abstract One among several advantages of measure transport methods is that they allow or a unified framework for processing and analysis of data distributed according to a wide class of probability measures. Within this context, we present results from computational studies aimed at assessing the potential of measure transport techniques, specifically, the use of triangular transport maps, as part of a workflow intended to support research in the biological sciences. Scenarios characterized by the availability of limited amount of sample data, which are common in domains such as radiation biology, are of particular interest. We find that when estimating a distribution density function given limited amount of sample data, adaptive transport maps are advantageous. In particular, statistics gathered from computing series of adaptive transport maps, trained on a series of randomly chosen subsets of the set of available data samples, leads to uncovering information hidden in the data. As a result, in the radiation biology application considered here, this approach provides a tool for generating hypotheses about gene relationships and their dynamics under radiation exposure.

gene expression data↗

Probing Quadrupolar Nuclei by Solid-State NMR Spectroscopy: Recent Advances

Solid-state nuclear magnetic resonance (NMR) of quadrupolar nuclei has recently undergone remarkable development of capabilities for obtaining structural and dynamic information at the molecular level. This review summarizes the key achievements attained during the last couple of decades in solid-state NMR of both integer spin and half-integer spin quadrupolar nuclei. We provide a concise description of the first- and second-order quadrupolar interactions, and their effect on the static and magic angle spinning (MAS) spectra. Methods are explained for efficient excitation of single- and multiple-quantum coherences, and acquisition of spectra under low- and high-resolution conditions. Most of all, we present a coherent, comparative description of the high-resolution methods for half-integer quadrupolar nuclei, including double rotation (DOR), dynamic angle spinning (DAS), multiple-quantum magic angle spinning (MQMAS), and satellite transition magic angle spinning (STMAS). Also highlighted are methods for processing and analysis of the spectra. Finally, we review methods for probing the heteronuclear and homonuclear correlations between the quadrupolar nuclei and their quadrupolar or spin-1/2 neighbors.

(DOR)↗

Differential cross-section measurements of the production of four charged leptons in association with two jets using the ATLAS detector

Differential cross-sections are measured for the production of four charged leptons in association with two jets. These measurements are sensitive to final states in which the jets are produced via the strong interaction as well as to the purely-electroweak vector boson scattering process. The analysis is performed using proton-proton collision data collected by ATLAS at $\sqrt{s}$ = 13 TeV and with an integrated luminosity of 140 fb –1 . The data are corrected for the effects of detector inefficiency and resolution and are compared to state-of-the-art Monte Carlo event generator predictions. The differential cross-sections are used to search for anomalous weak-boson self-interactions that are induced by dimension-six and dimension-eight operators in Standard Model effective field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for s channel single top quark production in pp collisions at $ \sqrt{s}=7 $ and 8 TeV

In this study, a search is presented for single top quark production in the s channel in proton-proton collisions with the CMS detector at the CERN LHC in decay modes of the top quark containing a muon or an electron in the final state. The signal is extracted through a maximum-likelihood fit to the distribution of a multivariate discriminant defined using boosted decision trees to separate the expected signal contribution from background processes. The analysis uses data collected at centre-of-mass energies of 7 and 8 TeV and corresponding to integrated luminosities of 5.1 and 19.7 fb –1 , respectively. The measured cross sections of 7.1 ± 8.1 pb (at 7 TeV) and 13.4 ± 7.3 pb (at 8 TeV) result in a best fit value of 2.0 ± 0.9 for the combined ratio of the measured and expected values. The signal significance is 2.5 standard deviations, and the upper limit on the rate relative to the standard model expectation is 4.7 at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗