Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Results for the Third Quarter Calendar Year 2017 Tank 50 Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2017 (CY17) sample of Tank 50 salt solution are presented in tabulated form. The Third Quarter CY17 Tank 50 samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-62) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-63)] were obtained on July 17, 2017 and received at Savannah River National Laboratory (SRNL) on July 17, 2017. Prior to obtaining the samples from Tank 50, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cr Field Testing

This is a summary of CR Project Field Tests including: Borehole Dilution Tracer Tests (Point Estimates of Flow Velocity), Push-Pull Tracer Tests at R-42 and R-28 (Flow Velocity and Dual-Porosity), Long Term Pump Test Trends, Carbonate/Bicarbonate Injection in R-42 (Cr desorption?), Cross-Hole Tracer Test (CrPZ-2a, CrPZ-2b, R-28 Injections; CrEX-3 Pumping), and Long-Term Trends in Plume Periphery Monitoring Wells.

58 GEOSCIENCES↗

Nuclear Technology Research and Development (NTRD) Technical Monthly January FY18

A set of U 3 Si 5 crystal growths have been completed, varying crystal pull rate, rotation rate and crystal size to evaluate the effect of crystal growth parameters on the quality and uniformity of the resultant crystals in order to determine the best set of growth conditions to produce crystals suitable for use as reference materials. The reference crystals can then be used for a variety of experiments to produce a consistent data set to inform modeling and simulation. Characterization of these crystals is ongoing. (K. McClellan)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lessons Learned From Incentives Programs for Efficient Air Conditioners: A Review

One of the largest drivers of growing global energy demand is the increasing market penetration of air conditioners (ACs). Global sales of room ACs were up 9% in 2013 compared to 2012, and that growth is expected to accelerate in coming decades, particularly in large metropolitan areas with hot climates. This report focuses on financial incentive programs that aim to mitigate the energy consumption attributable to the growing stock of ACs. Financial incentives leverage private investments to pull higher-efficiency technologies into the market. Through detailed case studies of AC energy-efficiency incentive programs, we show the significance and diversity of these programs and describe and share lessons learned from their design and implementation. The report also describes how incentive programs can be designed to address other pressing concerns related to growing AC use, such as challenges to power supply reliability resulting from increased peak demand and the global warming potential (GWP) of AC refrigerants. For policy makers and program administrators interested in addressing AC energy efficiency through incentive schemes, the report provides examples of past and present programs and highlights challenges that need to be considered when making program design and implementation decisions. The report begins with an overview of AC markets, highlighting their growth and savings potential, recent achievements from minimum energy performance standards, and typical barriers to the penetration of more efficient AC models. Next, we examine six AC incentive programs in depth, based on evaluation reports and/or interviews with program administrators. Finally, we outline program design features that could a) increase penetration of energy-efficient ACs, b) increase utility and customer participation in demand response programs targeted at reducing peak-load impacts, and c) phase out the use of high-GWP refrigerants in ACs. We find that incentive programs are particularly effective when they target emerging technologies that have still a low penetration in the market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conversion of Plastic Work to Heat: A full-field study of thermomechanical coupling

This project targeted a full-field understanding of the conversion of plastic work into heat using advanced diagnostics (digital image correlation, DIC, combined with infrared, IR, imaging). This understanding will act as a catalyst for reformulating the prevalent simplistic model, which will ultimately transform Sandia's ability to design for and predict thermomechanical behavior, impacting national security applications including nuclear weapon assessments of accident scenarios. Tensile 304L stainless steel dogbones are pulled in tension at quasi-static rates until failure and full-field deformation and temperature data are captured, while accounting for thermal losses. The IR temperature fields are mapped onto the DIC coordinate system (Lagrangian formulation). The resultant fields are used to calculate the Taylor-Quinney coefficient, β, at two strain rates rates (0.002 s -1 and 0.08 s -1 ) and two temperatures (room temperature, RT, and 250°C).

36 MATERIALS SCIENCE↗

Los Alamos National Laboratory Lessons Learned for Fiscal Year 2018: SAVY-4000 Lid Bar Stock Issue

During acceptance testing at Nuclear Filter Technologies (NFT) in May, 2018 of a batch of 150 SAVY-4000 containers (3 Qt), 89 containers were rejected due to failing and higher than normal helium leakage test results (see attachment NC#18-033). A total of 56 of those rejected failed the maximum allowed helium leakage rate criterion of 1.0E-05 std cc/sec specified in 55Y-002926 Rev. G, SAVY-4000 fabrication Specification. In addition, 33 containers were also rejected by the manufacturer with helium leakage rates measured between 1.0E-05 and 1.0E-06 std cc/sec (NFT NC# 18-033) because the containers were manufactured from the same lot of base material and the helium leakage rates were outside of the expected range. Upon discovery of the helium leakage test failures of the 3 Qt SAVY’s, NFT pulled the inventory of containers that failed the helium leakage tests and performed a detailed inspection of the lid assemblies. Small voids were discovered by visual inspection on opposing sides of the lids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracking the Sun: Installed Price Trends for Distributed Photovoltaic Systems in the United States - 2018 Edition

Berkeley Lab’s Tracking the Sun report series is dedicated to summarizing installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The present report, the 11th edition in the series, focuses on systems installed through year-end 2017, with preliminary trends for the first half of 2018. As in years past, the primary emphasis is on describing changes in installed prices over time and variation in pricing across projects based on location, project ownership, system design, and other attributes. New to this year, however, is an expanded discussion of other project characteristics in the large underlying data sample. Future editions will include more of such material, beyond the report’s traditional focus on installed pricing. The trends described in this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected and cleaned for more than 1.3 million individual PV systems, representing 81% of U.S. residential and non-residential PV systems installed through 2017. The analysis of installed pricing trends is based on a subset of roughly 770,000 systems with available installed price data. Key findings from this year’s report include the following: -Installed Prices Continued to Fall through 2017 and into 2018. National median installed prices in 2017 were $3.7 per watt (W) for residential systems (a $0.2/W or 6% decline from the prior year), $3.1/W for small non-residential systems (a $0.4/W or 11% decline), and $2.2/W (a $0.1/W or 5% decline) for large non-residential systems. Data for the first half of 2018 show an additional drop of $0.1/W for residential and small non-residential systems, and effectively no change for large non-residential systems. These recent trends are generally consistent with the pace of price declines since 2014, and mark a slowing from the years immediately preceding (2009-2013) when prices fell by roughly $1/W per year. -Installed Prices Vary Widely Across Individual Projects. Among residential systems installed in 2017, 20% were priced below $3.0/W (the 20th percentile value) while another 20% were above the 80th percentile at $4.5/W. Non-residential systems also exhibit wide spreads, albeit shifted downward, from $2.4/W to $4.1/W for small non-residential and from $1.8/W to $2.8/W for large non-residential projects. These pricing spreads have persisted over time and are both reflective of the heterogeneity in PV systems and markets, as well as suggestive of the potential for further price declines. -Pronounced Pricing Disparities Exist Across States. State-level median installed prices in 2017 ranged from $2.6/W to $4.5/W for residential systems, from $2.2/W to $4.0/W for small non-residential systems, and from $2.1/W to $2.4/W for large non-residential systems. Three of the largest state markets (California, Massachusetts, and New York) are relatively high-priced, pulling overall U.S. median prices upward. These cross-state pricing differences reflect both idiosyncratic features of particular states as well as more-fundamental differences related to market and policy conditions. -Installed Pricing Variation Also Reflects Differences in System Design, Installer, and Customer Characteristics (among other factors). Significant pricing differences were also observed across system sizes within each customer segment (with median prices ranging from $3.2/W to $4.5/W across residential systems of varying size, and from $2.1/W to $3.7/W across non-residential systems), between third-party owned (TPO) and host-owned residential systems ($3.3/W vs. $3.8/W), across residential installers ($2.1/W to $9.6/W for host-owned systems and $1.1/W to $5.1/W for TPO systems), between residential new construction and retrofit systems in California ($2.3/W vs. $3.9/W), between large non-residential systems at commercial sites and tax-exempt customer sites ($2.1/W vs. $2.6/W), and between systems with standard vs. premium efficiency modules ($3.6/W vs. $4.2/W among residential systems). A public version of the underlying dataset can be downloaded at https://emp.lbl.gov/tracking-the-sun.

14 SOLAR ENERGY↗

Smart Monitoring of Nuclear Facilities [Slides]

This project pulls inspiration from modern smart home technologies and commercial IoT sensing and applies it to the challenge of monitoring and verification of nuclear facilities. Building off the idea that the whole is greater than the sum of its parts, the goal is to develop methods for combining disparate data representative of typical IAEA data streams to improve detection of undeclared activities at safeguarded facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer Network Connection for the Advanced Test Reactor Critical (ATR-C) Facility

The proposed activity would install a computer network connection in the Advanced Test Reactor Critical (ATR-C) Facility by running conduit from the west side office area near the entry into ATR-C and pulling in four category 5E (Cat5E) cables. The proposed activity would include running the Cat5E cables and associated conduit approximately 70 ft through the corridor from the office area and through the block wall into the southwest corner of ATR-C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Peculiar Acoustics of Rocks

For centuries, humans have used rocks as building materials. From the Parthenon of ancient Greece to the more recent Strasbourg cathedral to the Texas State capital building rock endures. Although the mechanical and acoustical properties of rocks should be very well known, it turns out that quite the opposite is true. Rocks, in fact, exhibit some very peculiar behaviors. In addition to often being nonlinear, they exhibit hysteresis when pushed and pulled and have mechanical properties that slowly vary in time. All of these behaviors may also vary in their response, depending on the stimuli. Thus, although in some ways rocks can be treated as simple solids, in other ways they behave more like fluids. The real answer, however, is somewhere in between. Because of the complexity of the behavior of rocks, our quest is for measurements and for the simplest models that can capture all the important features of the peculiar behavior of a rock. Ultimately, such models can be used to predict and better understand what goes on beneath our feet.

58 GEOSCIENCES↗

Pushoff Trailer, 60m3, Tractor Propelled, Construction

Based on a single pushoff trailer manufactured by Fliegl, with a 60-cubic-meter capacity and pulled by a separate tractor. This unit process quantifies the amount of steel plate needed to construct a single trailer. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=7FAA1D25-DB70-4E68-89D7-496325873158

42 ENGINEERING↗

Coal Unit Train Assembly, 100 Railcars, Construction

Calculates the number of locomotives and railcars needed to haul coal from the coal mine to the power plant over the lifetime of the plant. Assumes one locomotive can pull 20 capacity-laden railcars with 100 railcars per unit train. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=0B4ACAAE-2731-48A8-AD94-393C4D0E946C

01 COAL, LIGNITE, AND PEAT↗

Tanker Unit Train Assembly, 100 Railcars, Construction

Calculates the number of locomotives and tanker railcars needed to carry fuel from a loading point to the plant/refinery over the lifetime of the plant. Assumes one locomotive can pull 20 capacity-laden railcars with 100 railcars per unit train. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=034785B4-D05A-482E-BD0A-C55301E0E3AA

42 ENGINEERING↗

Sierra/SD - Theory Manual

Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer_notes manual, the user's notes and of course the material in the open literature.

97 MATHEMATICS AND COMPUTING↗

Characterization Results of SRS Tank 26 Samples FTF-26-19-12 and -13

Savannah River Remediation (SRR) has requested that the Savannah River National Laboratory (SRNL) characterize several samples from the Savannah River Site (SRS) Tank Farm in preparation for Sludge Batch (SB) 10. This report documents the characterization of Tank 26 material received by SRNL in May of 2019. SRR pulled 2 x 200 mL samples (FTF-26-19-12 and FTF-26-19-13) with Tank 26 slurry pumps at 60 inches. Two samples were taken to ensure SRNL has adequate material for the requested analyses. Because both samples were taken at the same time and at the same tank level, SRNL combined the two Tank Farm samples into one sample prior to analyses. Results presented in this report include: weight percent solids, density, elemental composition of supernate and slurry, Cs-137 in supernate and slurry, and slurry total alpha and beta. The sample contained higher than expected total sulfur with a significant insoluble fraction, prompting SRR-E to request a washing study to predict how sulfur will be removed during Tank Farm washing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sierra/SD - Theory Manual

Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD, we refer the reader to Sierra/SD, Users Notes. Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer_notes manual, the user's notes and of course the material in the open literature.

97 MATHEMATICS AND COMPUTING↗

Initial Atmospheric Transport of Particles

A new version of the Initial Atmospheric Transport (IAT) model has been developed. This report fully characterizes the new model. IAT is designed to model heat release into the atmosphere that contains contaminated particles. The heat release forms a buoyant puff or plume. Buoyancy is quickly dissipated in 10's to 100's of seconds through drag and entrainment of ambient air. The final location of contaminant particles in the atmosphere after dissipation of abnormal heat is an important input to long term transportation codes such as the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) code. Ultimately the settling of contaminants after long term transport provides a basis for estimating health consequences. In comparison to the old version, the new model includes explicit simulation of particles, newly formulated equations of motion for a rising puff, and a new plume model. The plume model releases many instances of a single puff along a single trajectory in a way that balances energy released over a longer period than would be appropriate for a single puff. The puff model has additions for vorticity, turbulence, virtual mass, drag, and entrainment. The particle model leads to direct interfacing between IAT and the long-term transport code HYSPLIT. Previously, particle locations were given a pattern based on IAT's puff trajectory with no particle simulation. Now, particles are explicitly simulated, and 3-D spatial distributions of particles are output based on final positions. Ballistic particles are thrown outward at high velocity from explosive events and tend to hit the ground before the end of the simulation. Non-ballistic particles tend to get pulled into the rising puff s ring of vorticity with some escaping to ambient conditions as buoyant energy dissipates. A new model verification and validation effort was made for the new plume model. The Wallops Island Solid Rocket Propellant (SRP) fire plume was extracted to a 3-D transient dataset. After calibration, the model performs better than previous single puff attempts. Even so, error levels in the process used to estimate location and ambient weather conditions approach 30%. This leads to the conclusion that unplanned photogrammetry evaluations of the IAT model are useful but not sufficiently accurate to quantify model parameters. Like previous attempts, the vertical motion entrainment parameters come out much too high in comparison to values for other studies in the literature. It is suspected that a new model of shear entrainment would alleviate this problem. Unfortunately, IAT already has more calibration parameters than the data comparisons thus far can resolve with statistical certainty. This underscores the need to verify and validate the IAT model using detailed CFD studies that allow ideal statistical comparison with the IAT model for hundreds of cases. Even so, validation by comparison to carefully planned experiments (i.e. with acceptable error levels) is also necessary because the dynamics of entrainment are at a sub-grid level for CFD. Though better validation and verification are most important, many new enhancements are still envisioned for future IAT development. These include particle rain out due to condensation and agglomeration of water, direct connection to the North American Mesoscale (NAM) weather dataset, dynamic weather conditions, including ambient particle entrainment into the puff, and detrainment at the puff to ambient mixing interface. In general, including detailed aerosol dynamics is the greatest coming challenge which will require an entire new sub-model in IAT. This is very important if contaminant particles change in such a way that they increase or decrease in their potential harm to the environment.

54 ENVIRONMENTAL SCIENCES↗

Efficiency Enhancing Anti-Frost Coatings for Heat Exchangers

As part of the Cyclotron Road program, the participant worked to develop geometric inorganic metamaterial coatings with functional surface energies that approached theoretical minimum. Most coating technologies chemically modify surfaces by applying a fluoropolymer to cause water to bead and roll off the surface, but the metamaterial coatings studied under this project were designed to modify local surface tension of a droplet, such that it pulls down on it at the bottom like a spring and as the droplet grows, the magnitude of the surface tension force increases to overwhelm droplet adhesion forces, causing the droplet to be repelled. These attributes make this technology ideally suited for heat transfer applications. This project’s coating experiments on evaporator coils inside an air conditioning unit demonstrated significant increases in energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗